GME8 SEriES
Multi-Position, Dual$aver
Multi-sPeeD Gas Furnace
80% AFUE
HeatinG inPut: 70,000–115,000 Btu/H
Standard Features
• Dual-diameter tubular heat exchanger
• Two-stage gas valve that allows installer to
turn on two-stage operation with the flip
of a dipswitch
• Energy-efficient circulator motor (EEM)
• 115V Silicon Nitride igniter designed for long igniter life
• Furnace control board with self-diagnostics, color-cod-
ed low-voltage terminals, and provisions for electronic
air cleaner and 24-volt humidifiers
• Control board stores the last five diagnostic codes in
memory; simple push-button activation outputs the
fault history to a flashing red LED
• Low constant fan allows homeowner to activate the
low heat speed to efficiently circulate air throughout
the home.
• Self-adjusting feature automatically adjusts furnace to
high- or low-stage operation based on outside tem-
perature without an outdoor temperature sensor
•
All models comply with California NOx emissions standards
Cabinet Features
• Fully insulated, heavy-gauge steel cabinet with durable
baked-enamel finish
™
• Foil-faced insulation lines the heat exchanger
• Designed for multi-position installation: upflow,
horizontal left or right
•
Removable bottom for side- or bottom-return applications
• Convenient left or right connection for gas/
electric service
Contents
Nomenclature ................................................................................................... 2
Product Specifications ................................................................................. 3
Dimensions ......................................................................................................... 4
Airflow Data ....................................................................................................... 5
Wiring Diagrams .............................................................................................. 6
Accessories ......................................................................................................... 8
• Top gas connection on most models
• Coil and furnace fit flush for most installations
*
Exchanger Limited Warranty (good for as long as you own your home), 10-Year Unit Replacement Limited Warranty and
10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is
not required in California or Québec.
SS-GME8
11/10
Supersedes 3/10
ProDuct sPeciFications
sPeciFications
GME8
0703BXC*
GME8
0905CXC*
GME8
1155CXC*
Performance Data
Input¹
70,000
56,000
48,000
80
90,000
72,000
64,000
80
115,000
92,000
80,000
80
Output¹
LP Output¹
AFUE²
Tons AC @ 0.5” ESP
Temperature Rise Range (°F)
Circulator Blower
Size (D x W)
3
5
5
20 - 50
35 - 65
35 - 65
10 X 8
1/2
4
10 X 10
10 X 10
HP
1
4
1
4
Speed
Vent Diameter³
No. of Burners
Disposable Filter (in²)
Electrical Data
Min. Circuit Ampacity⁴
Max. Overcurrent Protecꢀon⁵
Ship Weight (lbs)
4
4
4
3
4
5
290
480
480
8.2
15
14.8
15
14.8
15
130
163
167
¹
Natural Gas BTU/h: for alꢀtudes above 2,000’, reduce input raꢀng 4% for each 1,000’ above sea level. Low-fire rate is
75% of high-fire rate.
²
³
DOE AFUE based upon Isolated Combusꢀon System (ICS).
Vent diameter may vary depending upon vent length. Refer to the latest ediꢀons of the Naꢀonal Fuel Gas Code NFPA
54/ANSI Z223.1 (in the USA) and the Canada Naꢀonal Standard of Canada, CAN/CSA B149.1 and CAN/CSA B142.2 (in
Canada).
4
5
Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in ac-
cordance with Naꢀonal Electrical Codes. Extensive wire runs will require larger wire sizes.
Refers to maximum recommended fuse or circuit breaker size; may use fuses or HACR-type circuit breakers of the same
size as noted.
Notes
•
All furnaces are manufactured for use on 115 VAC, 60 Hz, single phase electrical supply.
•
•
Gas Service Connecꢀon ½” FPT
Important: It is required to size overcurrent protecꢀon device and wires properly and make electrical connecꢀons in ac-
cordance with the Naꢀonal Electrical Code and/or all exisꢀng local codes.
SS-GME8
3
ProDuct sPeciFications
DiMensions
Alt. Gas Inlet
Alt. Gas Inlet
Alt. High Voltage
Alt. LowVoltage
High Voltage Inlet
Low Voltage
Model
GME80703BXA
GME80905CXA
GME81155CXA
A
B
17½”
21”
16”
19½”
19½”
21”
MiniMuM clearances to coMBustiBle Materials
Vent
Sides
Rear
Front
Bottom
Top
SW
B
1
0
3
C
6
1
1
C = If placed on combusꢀble ꢁoor, the ꢁoor MUST be wood ONLY.
Notes:
•
•
•
•
For servicing or cleaning, a 24” front clearance is recommended.
Unit connecꢀons (electrical, ꢁue, and drain) may necessitate greater clearances than the minimum clearances listed above.
In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.
Refer to the appropriate USA and Canadian codes:
◊
◊
In the USA: the Naꢀonal Fuel Gas Code NFPA 54 / ANSI Z223.1
In Canada: the Canada Naꢀonal Standard of Canada, CAN/CSA B149.1 and CAN/CSA B142.2
4
SS-GME8
ProDuct sPeciFications
airFlow Data
(CFM & Temperature Rise vs. External Static Pressure)
External Static Pressure, (Inches Water Column)
Motor
Speed
Tons
AC¹
Model
0.1
0.2
0.3
0.4
0.5
0.6
CFM
556
756
964
0.7
CFM
509
712
918
0.8
CFM
460
659
877
CFM
875
Rise
59
50
43
38
33
53
49
42
38
31
58
52
49
46
37
CFM
793
Rise
65
54
45
39
34
56
51
44
39
31
60
53
49
47
37
CFM
736
Rise
70
57
47
41
36
58
53
45
40
32
63
55
50
48
38
CFM
674
Rise
77
60
49
42
37
61
55
47
41
32
65
57
51
49
40
CFM
592
Rise
88
64
51
44
38
64
57
48
42
33
68
59
53
50
42
T1
T2
T3
T4
T5
T1
T2
T3
T4
T5
T1
T2
T3
T4
T5
1½
2
1,032
1,217
1,365
1,549
1,268
1,362
1,576
1,755
2,183
1,466
1,642
1,750
1,870
2,297
965
914
861
810
GME8
0703BXC*
2½
3
1,153
1,313
1,505
1,198
1,305
1,519
1,711
2,128
1,415
1,596
1,750
1,805
2,297
1,098
1,268
1,460
1,151
1,261
1,473
1,657
2,094
1,357
1,552
1,707
1,782
2,224
1,051
1,221
1,420
1,092
1,212
1,426
1,627
2,060
1,306
1,499
1,667
1,737
2,106
1,009
1,172
1,378
1,041
1,170
1,398
1,579
2,014
1,248
1,449
1,610
1,701
2,014
1,129 1,086 1,054
1,350 1,305 1,268
3½
2½
3
988
932
883
1,121 1,074 1,021
1,341 1,290 1,252
1,548 1,502 1,463
1,992 1,944 1,847
1,202 1,144 1,088
1,388 1,352 1,306
1,574 1,531 1,486
1,656 1,606 1,571
1,896 1,813 1,669
GME8
0905CXC*
3½
4
5
3
3½
4
GME8
1155CXC*
4
5
¹
@ 0.5” ESP
Notes
•
CFM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer. If the furnace requires two return filters,
this chart assumes both filters are installed.
•
•
•
•
•
All furnaces ship as high-speed cooling and medium-speed heaꢀng. Installer must adjust blower cooling and heaꢀng speed as needed.
For most jobs, about 375 - 400 CFM per ton when cooling is desirable.
INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE.
This chart is for informaꢀon only. For saꢀsfactory operaꢀon, external staꢀc pressure should not exceed value shown on the raꢀng plate.
The above chart is for U.S. furnaces installed at 0-2000 feet. At higher alꢀtudes, a properly derated unit will have approximately the same
temperature rise at a parꢀcular CFM, while ESP at the CFM will be lower.
•
•
Factory Motor Speed Seꢂng: T1 = 1st Stage Ht, T2 = 2nd Stage Ht, T5 = Cooling
Tempertaure rise data is based on 2nd-stage heat. First-stage heat is 75% of rise indicated above.
SS-GME8
5
ProDuct sPeciFications
wirinG DiaGraM witH wHite-roDGers valve
INTEGRATED
CONTROL MODULE
HUMIDIFIER
XFMR (6)
WARNING:DISCONNECT POWER BEFORE
SERVICING.WIRING TO UNIT MUST BE
PROPERLY POLARIZED AND GROUNDED.
GND
GND (8)
MVC (9)
24 VAC
HUMIDIFIER
C2
GAS
HI VALVE
MVH (12)
MVL (2)
M1
C
ID BLOWER
PRESSURE
SWITCH
AUXILIARY
LIMIT CONTROLS
C
G
R
W
Y
G
Y
NO
PS (10)
PSO (4)
C
AUTO
1 STG
5 MIN
2 STG MODE
100 SEC
150 SEC
TO
MICRO HLI (7)
10 11 12
WH
BL
W
7
4
1
8
5
2
9
6
3
HLO (1)
AUTO RESET
PRIMARY
LIMIT
FUSE
R
RO2 (11)
RO1 (5)
SEE NOTE 6
BR
CONTROL
AUXILIARY
LIMITS
INTEGRATED
CONTROL MODULE
MANUAL RESET ROLLOUT
LIMIT CONTROL(S)
(SINGLE CONTROL ON SOME MODELS)
XFMR (3)
FS
24 VAC
40 VA
BR
BL
TRANSFORMER
XFMR-N
RD
XFMR-H
115 VAC
FLAME SENSOR
2
1
FP
HOT SURFACE
IGNITER
XFMR-H
LINE-H
EAC-H
IGN
IND
IGN-N
PARK
ID
BLWR
BK
IND-N
BK
24V
COOL-H
CIRCULATOR
BLWR
115V
CIR-N
XFMR
WH
ELECTRONIC
AIR CLEANER
BK
15 PIN PLUG
ON SOME MODELS
EAC-H
LINE-H
GR
EAC-N
BLOWER COMPARTMENT
LINE-N
JUNCTION BOX
BURNER COMPARTMENT
DOOR
SWITCH
24 VAC
HUMIDIFIER
DOOR SWITCH
SWITCH LOCATED IN BLOWER
COMPARTMENT ON SOME MODELS
NO
C
WARNING:
RD
RD
DISCONNECT POWER
BEFORE SERVICING.
WIRING TO UNIT
MUST BE
PROPERLY
POLARIZED
DISCONNECT
PRESSURE
SWITCH
YL
YL
PRIMARY LIMIT
YL
RD
YL
WH
BK
AND GROUNDED.
L
GND
N
BR
TO 115VAC/ 1
OVERCURRENT PROTECTION DEVICE
Ø /60 HZ POWER SUPPLY WITH
BL
WH
BK
PM
1
C
2
HI
3
JUNCTION
BOX
HOT
SURFACE
IGNITER
2 STAGE
GAS VALVE
LINE-N
GND
LINE H
PU
INDUCED DRAFT
BLOWER
TO 115 VAC/ 1/60HZ
POWER SUPPLY WITH
OVERCURRENT PROTECTION
DEVICE
PU
PU
FLAME
SENSOR
ROLLOUT LIMITS
(SINGLE CONTROL ON SOME MODELS)
0
STEADY ON = NORMAL OPERATION
LOW VOLTAGE (24V)
LOW VOLTAGE FIELD
HI VOLTAGE (115V)
HI VOLTAGE FIELD
JUNCTION
EQUIPMENT GND
FIELD GND
OFF
= CONTROL FAILURE
1
2
3
4
5
6
7
8
C
1 FLASH
=
SYSTEM LOCKOUT (RETRIES/RECYCLES EXCEEDED)
2 FLASHES = PRESSURE SWITCH STUCK CLOSED
3 FLASHES = PRESSURE SWITCH STUCK OPEN
4 FLASHES = OPEN HIGH LIMIT
FIELD SPLICE
SWITCH (TEMP.)
IGNITER
5 FLASHES = FLAME SENSE WITHOUT GAS VALVE
TERMINAL
6 FLASHES =
OPEN ROLLOUT OR OPEN FUSE
SWITCH (PRESS.)
INTERNAL TO
INTEGRATED CONTROL
7 FLASHES = LOW FLAME SIGNAL
OVERCURRENT
PROT. DEVICE
8 FLASHES = CHECK IGNITER OR IMPROPER GROUND
RAPID FLASHES = REVERSED 115 VAC POLARITY/VERIFY GND
PLUG CONNECTION
NOTES:
1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.
2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.
PK PINK
COLOR CODES:
YL YELLOW
OR ORANGE
PU PURPLE
GR GREEN
BR BROWN
WH WHITE
BL BLUE
GY GRAY
RD RED
3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED, IT MUST BE REPLACED WITH
WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105 °C. USE COPPER CONDUCTORS ONLY.
4. BLOWER SPEEDS SHOULD BE ADJUSTED BY INSTALLER TO MATCH THE INSTALLATION REQUIREMENTS SO AS TO
PROVIDE THE CORRECT HEATING TEMPERATURE RISE AND THE CORRECT COOLING CFM. (SEE SPEC SHEET FOR AIR
FLOW CHART)
5. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES.
6. TO RECALL THE LAST 5 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS
WHILE IN STANDBY(NO THERMOSTAT INPUTS).
BK BLACK
0140F00643 REV. A
SS-GME8
7
ProDuct sPeciFications
Dual$aver conFiGuration oPeration
&
Dual$aver™
This furnace is capable of the following heating modes:
•
•
Single Stage (Factory Setting)
Modified Two-Stage
»
»
Fixed 5-Min Low Stage
Auto Time (1-12 Min) Low Stage
Start
Call for Heat
Safety Circuit Check
Start Furnace
in Low Stage
Low-Heat Blower
Delay Time (5 Min)
or Delay Time (1-12 Min)
Gas Valve Switch
to 2nd Stage
Blower Switch to
Hi Heat Operaꢀon
T-Stat Saꢀsfied
accessories
GME8
0703BX
GME8
0905CX
GME8
155CX
Model
Description
LPM-05
LPM-06
LP Conversion Kit (Springs & Orifice)¹
LP Conversion Kit (Springs & Orifice)²
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
FSRKG-14/17/21/24 Noise Reducꢀon Kits
MVK-01³
HA02
Masonry Vent Kit
High-Alꢀtude Natural Gas Kit
Fossil Fuel Kit
AFE18-60A
¹
²
³
White-Rodgers valves only
Honeywell or White-Rodgers valves
Upꢁow applicaꢀons only
Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without
notice or without incurring obligations. © 2010 • Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA.
8