Franke Consumer Products Paper Shredder FFPD100 User Manual

FFPD100 SERIES  
Swivelling spout faucet with spray head  
Installation guide  
 
Faucet installation  
Please remove all components from package and inspect prior to  
installation (see itemized table and picture).  
NOTE:  
Call us immediately if you see inconsistencies. (1-800-626-5771)  
or visit  
TABLE OF CONTENTS  
1
2
3
4
5
6
Faucet  
Wall fastening set  
Wall flange (over the sink)  
Wall flange (under the sink)  
Fastening set (rubber washer, triangular flange, metal washer, nut)  
Non-return valves  
1
5
6
3
4
2
3
 
2. Remove all mounting hardware from protecting plastic bag.  
3. Place the large O-ring over the faucet shank and place the faucet into the desired  
location.  
NOTE:  
the rubber O-ring should be sitting on top of the countertop and between the faucet  
body. DO NOT use putty or other sealant at this location  
4. Install the mounting hardware (G R0338031) to the threaded shank in the following  
sequence:  
1 - round flat fiber washer  
2 - triangular shaped plastic support  
1
2
3 - flat metal washer  
4 - thread brass nut  
4
3
21 mm [13/16”] key  
5. Assure that the handle and spout are properly aligned in forward position  
6. Tighten the brass nut (4) with the provided wrench or use other professional tools.  
7. Connect the supply flexible hoses to the supply net, interposing between-them the  
non-return valve with the gaskets as indicated in the figure.  
NOTE:  
solid surface installation: The sub-countertop mounting surface  
needs to be flat and free of debris; otherwise the faucet will not  
sit properly.  
Tile installation: Avoid installations near or on top of grout lines.  
The faucet will not sit secure when sitting on such.  
4
 
7. The body can be fixed both onto the wall and on surface: .  
1. Screw the fixing rail onto the single lever body.  
2. Insert it completely in the given plate.  
3. Place the single lever body into the sink hole made at a certain distance from  
the wall.  
4. Place the plate properly where it has to be fixed, making sure the drilling  
points on the wall are well marked corresponding to the two holes with a 28  
mm [1-1/8”] interaxe.  
5. Place the dowels in the holes.  
6. Fix the plate onto the wall with the given screws.  
7. give stability to the position of the single lever by acting on the fixing rail  
and block the movement with the given nut.  
over the sink  
under the sink  
A
B
8. Flush out debris from water lines and faucet.  
1. Pull spray hose out of the faucet spout and point the open end towards the  
sink drain.  
2. Open faucet handle - cold side first - by turning handle to the right and mov-  
ing it upward.  
3. Let the faucet run on cold for 15 to 30 seconds.  
4. Open faucet handle - hot side second - by turning handle to the left and mov-  
ing it upward.  
5. Let the faucet run on cold for 15 to 30 seconds.  
6. Turn faucet off.  
7. Test for leaks under the cabinet.  
5
 
Standard maintenance and trouble shooting  
Cleaning of the spray head  
Any deposits which may accumulate on the nozzle can be removed by simply running  
a finger over the rubber extrusions and then running the water for a few seconds. In  
extreme cases this step may have to be repeated.  
Replacing the Cartridge  
1. Shut off the water supply to the faucet.  
2. Open the faucet briefly to relief any pressure inside the faucet.  
3. Move the faucet handle to the “OFF” position.  
4. Use a the provided allen key to loosen the set screw which is accessible from the back  
of the handle.  
5. Lift the handle from the cartridge.  
2.5 mm [1/8”] key  
6. Find the small notch at the base of the chrome ring cap and carefully pry up against  
this to remove the cap.  
28 mm [1-1/8”] key  
7. Remove the brass retaining ring.  
8. Lift out the cartridge.  
9. Ensure that the seats and O-rings are in good condition.  
10. Remove potential mineral deposits from inside the faucet body.  
11. Install the new cartridge so that the central pivots fit into the corresponding seats.  
12. Re-assemble faucet in reverse order.  
13. Test for leakage.  
6
 
Replacing the Headvalve  
1. Shut off the water supply to the faucet.  
2. Open the faucet briefly to relief any pressure inside the faucet.  
3. Move the faucet knob to the “OFF” position.  
4. Use a the provided allen key to loosen the set screw which is accessible from the back  
of the handle.  
5. Lift the handle from the headvalve.  
6. Unscrew then the headvalve using a 17 mm wrench and replace it.  
7. Reinstall all the details, proceeding in opposite order.  
2 mm [1/16”] key  
17 mm [11/16”] key  
General maintenance  
Clean aerator periodically.  
Do not use harsh detergents, solvents, chemical agents, metallic sponges, etc. that could  
harm the surface.  
Clean only with a soft sponge and soapy water,  
Clean and then dry properly the faucet in case of very hard or calcareous water, whose  
deposits cold damage the surface.  
7
 
Limited lifetime warranty  
Franke Consumer Products, Inc., Kitchen Systems Division extends the following warranty to the origi-  
nal purchaser of its faucets effective January 1, 2003.  
All faucets installed in a private residence will carry a limited lifetime warranty on all mechanical  
parts to be free of manufacturing defects in material and workmanship under normal usage. All chrome  
finishes carry a limited lifetime warranty; all other finishes are warranted for five (5) years form the  
original date of purchase.  
Marine and Outdoor Installation: Franke Consumer Products, Inc. faucets are NOT warranted for  
Marine and Outdoor installations.  
This warranty applies only to the original owner, providing the product has been installed in accordance  
with our installation instructions, used as recommended and in a normal residential application. In the  
event of a warranty claim, the owner will be required to provide proof of purchase - save sales  
receipt. This warranty covers all components which make the product operational. Franke, at its op-  
tion, may repair or replace the product or components necessary to restore the product to good working  
condition. Franke reserves the right to inspect the installation prior to the actual replacement of the  
product or component part.  
This warranty does not cover misuse or abuse, accidental damages, scuffs or scratches, improper installa-  
tion, abnormal usage, negligence or damage caused by improper maintenance or cleaning. Normal wear  
of parts is excluded from the warranty. Damage caused by impurities or acts beyond our control are not  
covered. Any product or part which has been repaired or altered in any manner outside of Franke’s fac-  
tory, unless previously authorized in writing by Franke, will void warranty. Any replacement excludes  
transportation and any labor re-installation costs. This warranty does not allow recovery of incidental  
or consequential damages such as loss of use, delay, property damage or other consequential damage,  
and Franke accepts no liability for such damages.  
The Franke warranty is limited to the above conditions and to the warranty period specified herein and is  
exclusive. Franke DISCLAIMS all other warranties, expressed or implied, including IMPLIED WAR-  
RANTIES OF MERCHANTABILITY AND/OR FITNESS FOR AS PARTICULAR PURPOSE. This  
warranty gives you specific legal rights that may vary from state to state.  
Further information  
For any further information about our products, about the installation  
of them or about the guarantee, please dial the number of the  
customer service:  
Phone number +1-215-822-6590  
Or: 1-800-626-5771  
Fax number + 1-215-822-5873  
Franke Consumer Products Inc. - Kitchen Systems Division  
3050 Campus Drive, Suite 500 Hatfield, PA 19440  
8
 

EAW Speaker UB22z User Manual
Eiki Projector LC SE10 User Manual
Extron electronic Switch DA6 YUV A User Manual
Fellowes Laminator L80 95 User Manual
Fisher Paykel Garbage Disposal GD50S1 User Manual
Fisher Price Battery Charger H7455 User Manual
Frigidaire Cooktop FGEC3665K User Manual
Furuno Radar Detector FRS 1000A User Manual
GE Cordless Telephone 16223870 User Manual
GE Telephone 16017970 User Manual