SD5TAC Series
Spectra Lite™
Dome Systems
Operation and
Programming Manual
C2422M (5/00)
In North America and Canada: Tel (800) 289-9100 • FAX (800) 289-9150
International Customers: Tel +1(559) 292-1981 • FAX +1(559) 348-1120
IMPORTANT SAFEGUARDS AND WARNINGS
Prior to installation and use of this product, the following WARNINGS should be observed.
1. Installation and servicing should only be done by qualified service personnel and
conform to all local codes.
2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P
enclosure, it is designed for indoor use only and it must not be installed where
exposed to rain and moisture.
3. Only use replacement parts recommended by Pelco.
4. After replacement/repair of this unit’s electrical components, conduct a resistance
measurement between line and exposed parts to verify the exposed parts have not
been connected to line circuitry.
5. The installation method and materials should be capable of supporting four times the
weight of the enclosure, pan/tilt, camera and lens combination.
The product and/or manual may bear the following marks:
This symbol indicates that dangerous voltage
constituting a risk of electric shock is present
within this unit.
CAUTION:
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
This symbol indicates that there are important
operating and maintenance instructions in the
literature accompanying this unit.
Please thoroughly familiarize yourself with the information in this manual prior to installation
and operation.
MEASURES DE SECURITE IMPORTANTES
Avant d’installer ou d’utiliser ce produit, les mesures de sécurité suivantes sont à prendre:
1. Toute installation et réparation devraient être entreprises par un technicien qualifié et
conformes au codes locaux.
2. A moins que cet equipement indique avoir un boitié agrée NEMA de type 3, 3R, 3S, 4,
4X, 6 ou 6P, il est uniquement conçu pour utilisation intérieure et ne peut donc pas
être en contact de pluie ou d’humidité.
3. Utiliser seulement les pièces de rechanges recommandées par Pelco.
4. Après toute installation ou réparation de la partie électrique de ce produit, une
résistance entre le courant et la partie exposée devrait être installée afin de vérifier
que la partie électrique n’aie pas été en contact d’un court circuit.
5. L’installation entreprise et le matériel utilisé devraient supporter quatre fois le poids du
boitié, de la tourelle, de la caméra, et de la lentille.
Ce produit et/ou le manuel pourrait inclurent les symbols suivants:
Ce symbol indique qu’un voltage
dangereux pouvant provoquer un chock
CAUTION:
électrique est présant dans cette unité.
RISQUE DE CHOQUE ÉLECTRIQUE.
NE PAS OUVRIR.
Ce symbol indique qu’il y a des mesures
d’installation et d’entretient importantes
inclus dans le manuel de cet équipement.
Nous vous prions de bien vous familiarisez avec la manuel avant d’entreprendre toute in-
stallation.
Pelco Manual C2422M (5/00)
3
OPERATION
POWER-UP DISPLAY
When the Spectra Lite™ dome is powered up, the selected protocol, revision number, and
other information is displayed on the monitor. For example, the screen might show the
following information:
The information displayed depends on the selected
protocol (C, D, or P) and the menu selection for power-
PELCO SPECTRA LITE
up mode. (Refer to the Power-Up Mode in the
CONFIGURE DONE
Programming section).
Protocol C
The information remains on the monitor until the dome
is moved.
HOW TO OPERATE YOUR SPECTRA LITE DOME
Operation
Pan and Tilt
Scanning
How to Control
Move joystick left/right and up/down.
Stop Scan
Preset 96
Preset 97
Preset 98
Preset 99
Random Scan
Frame Scan
Auto Scan
Zoom Far
To zoom far, do the following:
1. Press the Zoom Tele button or turn the joystick clockwise until you have the picture you want or you
reach the zoom limit.
2. Release the button or joystick.
Zoom Wide
Presets
Press the Zoom Wide button or turn the joystick counterclockwise.
Refer to the documentation supplied with the controller.
Auto Flip
Turn on or off in the programming menu. Refer to the Programming Guide in the Programming section.
For more information, refer to Operating Notes.
4
Pelco Manual C2422M (5/00)
OPERATING NOTES
PAN AND TILT FUNCTIONS
Controller Type
Fixed speed
Variable speed
Turbo Mode
Pan
Tilt
Speed determined by controller
0.5 to 80° per second, depending on joystick position
150° per second
Speed determined by controller
0.5 to 40° per second, depending on joystick position
200° per second
Preset Mode
250° per second
Does not affect the tilt speed
AUTO FLIP
When the camera tilts downward and goes just beyond the vertical position, the dome
rotates 180 degrees. When the dome rotates (flips), the camera starts moving upward as
long as you continue to hold the joystick in the down position. Once you let go of the joystick
after the dome rotates, joystick control returns to normal operation. The auto-flip feature is
useful for following a person who passes directly beneath the camera. Refer to Auto Flip in
the Programming section.
SCAN SPEED
Scan speed is adjustable from 1 to 40 degrees per second through the programming menu.
PRESET FUNCTIONS
The Spectra Lite dome can go to 32 presets. The presets are numbered 1-32. Refer to the
documentation for your control system for programming presets.
NOTE: For American
Dynamics controllers with
only 32 presets, set switch
SW1-7 on the dome drive in
the ON position. When
SW1-7 is ON, preset
When a preset operation is performed, the amount of error in moving to the pan and tilt
position is 1/2 degree. If you command the dome to go to an undefined preset, erratic
operation may result.
Presets 33 and 34 are fixed commands, meaning that you cannot program them. Preset 33
is the “flip” command, which will pan the dome drive 180 degrees. Preset 34 is the “pan zero”
command, which will direct the dome drive to the factory-determined zero reference point.
99 becomes 32
98 becomes 31
97 becomes 30
96 becomes 29
95 becomes 28
93 becomes 26
92 becomes 25
91 becomes 24
90 becomes 23
RANDOM, FRAME, AND AUTO SCANNING
Call preset 97 (30) to start random scanning. Call preset 98 (31) to activate frame scanning
(three seconds of scanning followed by a three-second pause). Call preset 99 (32) to start auto
(continuous) scanning. Scan limit stops are controlled by software. Refer to the Limit Stops
section to program the scan limit stops. When the dome reaches a scan limit stop, it reverses
direction. Call preset 96 (29) to stop a scan. Any pan/tilt or lens command also will stop a scan.
If the limit stops are turned
off (refer to the Limit Stops
section), presets 23-26 can
be used as regular presets.
PARK
If the dome does not receive any commands for a specified period of time (refer to Park
Time Minutes in the Programming section), the dome will go to preset 1 and park. If the
time specified is zero, or if preset 1 has not been programmed, the dome will not park.
The default is zero minutes.
AUTO IRIS
If auto iris is in the auto mode, it remains that way until you manually open or close the iris.
The dome will return to auto iris when it is panned or tilted more than 15 degrees. If there is
not enough light for a good picture when the iris is wide open, you can increase the gain of
the camera to improve the picture.
To increase the gain:
1. Hold down the Iris Open button until the iris is wide open.
2. Release the button.
3. Within one second, hold down the button again. This starts increasing the camera
gain. Hold down the button until a desirable picture is obtained or the maximum gain is
reached.
Pelco Manual C2422M (5/00)
5
PROGRAMMING
Programming Guide - Spectra Lite
1. Access main menu (preset 95).
2. Make main menu selections.
Joystick: Move up or down to position cursor or
to toggle between selections.
Iris Open: Enter
Gain/AGC Menu
Iris Close: Cancel
AGC mode
Gain
Exit
Auto
10
Camera Menu
Backlight comp
Reset camera
<Gain/AGC>
<Auto-iris>
<Next>
Off
Auto-Iris Menu
Exit
Auto-iris mode
Auto-iris level
Exit
Auto
180
Sharpness Menu
Line Sync Menu
MAIN MENU
Sharpness
Exit
5
Line sync
Line sync phase
On
0
Next Menu
<Camera>
<Line Sync>
<Power Up>
<Other>
Exit
Shutter speed
Auto focus mode Auto
<Sharpness>
<White balance>
Prev (back to prev. menu)
Exit
Auto
EXIT
White Balance Menu
Power-Up Menu
Auto white bal
White bal hue
Exit
Auto
26
Power Up
Exit
Default
PRESETS
The following presets are
reserved for special functions.
Preset
1
Function
Park
Other Menu
33
34
Flip command
Pan zero
command
Auto flip
Limit stops
Park time minutes
Scan speed deg/s 25
Exit
On
On
0
90-91
92-93
95
Manual limit stops
Scan limit stops
Select camera
programming
menu
96
97
98
99
Stop a scan
Random scanning
Frame scanning
Start auto
For detailed instructions, refer to the following sections.
Menu items are listed alphabetically.
scanning
6
Pelco Manual C2422M (5/00)
ACCESSING MAIN MENU (PRESET 95)
You can call up the main menu on your monitor by programming (setting or creating) preset
95 (28 if in 32-preset mode).
NOTE: For American
Dynamics controllers with
only 32 presets, set switch
SW1-7 on the dome drive in
the ON position. When
SW1-7 is ON, preset
Programming preset 95 for Pelco’s controllers varies according to the type of controller you
are using. Instructions for programming preset 95 are given below for various Pelco
controllers.
CM6700
99 becomes 32
98 becomes 31
97 becomes 30
96 becomes 29
95 becomes 28
93 becomes 26
92 becomes 25
91 becomes 24
90 becomes 23
1. Enter the number of the Spectra II or Spectra Lite camera and press the CAM key.
2. Enter 95 and hold the PRESET key for two seconds.
3. In the Edit Preset menu, arrow to SET and press the ACK key. The main menu appears.
KBD200/KBD300/KBD300V (Direct Mode Only)
1. Enter 95.
2. Hold the PRESET key (approximately 5 seconds) until the main menu appears on the
screen.
CM8500
If the limit stops are turned
off (refer to the Limit Stops
section), presets 23-26 can
be used as regular presets.
1. Enter the number of the Spectra II or Spectra Lite camera and press the CAM key.
2. Highlight PRESET in the Camera menu and hold down the joystick button until the Set
Presets prompt appears.
3. Enter 95 and press the PRESET key. The text editor appears. Select ENTER and the
main menu appears.
CM9500
1. Enter the number of the Spectra II or Spectra Lite camera and press the CAM key.
The Main menu appears.
2. Highlight SETUP in the Main menu and press the SELECT key.
3. Highlight CAM in the Setup menu and press the SELECT key.
4. Highlight PRESET in the Camera menu and press the SELECT key.
5. Enter 95 and press the F1 key. The main menu appears.
CM9750
1. Turn the KEY SWITCH to the ON position.
2. Press the PROG key. PROGRAM appears on the LCD display.
3. Press the PRES key. The PRESET prompt appears.
4. Enter 95 and press the ENTER key. The main menu appears.
5. Turn the KEY SWITCH to the OFF position.
CM9760
1. Press the ESCAPE key to open the Main menu. Select DEF. The Define Menu appears.
2. Enter your four-digit PIN if this is your first time entering this mode.
3. Enter 95 and select PRST. The main menu appears on the monitor.
4. Select the Quit icon to return to the default menu.
KBD4000/KBD4002/KBD4000V
1. Press the SPOT MONITOR key.
2. Enter 95, then hold the PRESET key (approximately five seconds) until the main menu
appears on the screen.
MPT9500
Standard Coaxitron Mode
1. Enter 95 and press the PRESET SET key.
2. Position the asterisk in the YES row and press the F1 key. The main menu appears.
Extended Coaxitron or RS-485 Mode
1. Enter 95 and press the PRESET SET key.
2. Press the F2 key. The main menu appears.
Pelco Manual C2422M (5/00)
7
AUTO FLIP
Main Menu
Other Menu
<Camera>
Auto flip
Limit stops
Park time minutes
Scan speed deg/s 25
Exit
On
On
0
<Line Sync>
<Power Up>
<Other>
EXIT
There are two auto flip modes:
On - Auto flip mode is enabled.
Off - Auto flip mode is disabled.
To change the auto flip mode:
1. Program preset 95 (28). The main menu appears.
2. Position the cursor (>) beside Other.
3. Press the Iris Open button to enter the Other menu.
4. Position the cursor (>) beside Auto Flip.
5. Press the Iris Open button. The cursor moves to the right, beside the word On or Off.
6. Move the joystick up or down to toggle between On and Off.
7. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL - Press the Iris Close button if you do not want to change the setting.
AUTO FOCUS MODE
Main Menu
Camera Menu
Next Menu
<Camera>
<Line Sync>
<Power Up>
<Other>
Backlight comp
Reset camera
<Gain/AGC>
<Auto-iris>
<Next>
Off
Shutter speed
Auto focus mode Auto
<Sharpness>
<White balance>
Prev (back to prev. menu)
Exit
Auto
EXIT
Exit
There are two auto focus modes:
Auto - If auto focus is in the auto mode, pressing the Focus Far or Focus Near button
will place the focus in the manual mode. The dome will return to auto focus if
you pan or tilt the unit or do a zoom function.
Off - If the mode is set to off, the dome will operate in the manual mode with one
exception. If you issue a command to go to a preset, auto focus will turn on and
remain on until you press the Focus Far or Focus Near button.
To change the mode:
1. Program preset 95 (28). The main menu appears.
2. Position the cursor (>) beside Camera.
3. Press the Iris Open button to enter the Camera menu.
4. Position the cursor (>) beside Next.
5. Press the Iris Open button to go to the Next menu.
6. Position the cursor (>) beside Auto Focus Mode.
7. Press the Iris Open button. The cursor moves to the right, beside the word Auto or Off.
8. Move the joystick up or down to toggle between Auto and Off.
9. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL - Press the Iris Close button if you do not want to change the setting.
NOTE: Auto focus is auto-
matically turned off when
the shutter time is longer
than 1/8 of a second.
8
Pelco Manual C2422M (5/00)
AUTO IRIS
Main Menu
Camera Menu
Auto-Iris Menu
Backlight comp
Reset camera
<Gain/AGC>
<Auto-iris>
<Next>
Off
<Camera>
Auto-iris mode Auto
<Line Sync>
<Power Up>
<Other>
Auto-iris level
Exit
180
EXIT
Exit
The following are the settings for auto iris:
Mode
Level
To change the settings for auto iris:
1. Program preset 95 (28). The main menu appears.
2. Position the cursor (>) beside Camera.
3. Press the Iris Open button to enter the Camera menu.
4. Position the cursor (>) beside Auto-Iris.
5. Press the Iris Open button. The Auto Iris menu appears.
6. Position the cursor (>) and select one of the following settings:
MODE - The cursor moves to one of two choices:
Auto - The iris is automatically adjusted to produce a constant video output as deter-
mined by the Level setting.
Off - Auto iris is disabled, and control is always manual.
Move the joystick up or down to toggle between Auto and Off. Press the Iris Open
button to select the choice, or press the Iris Close button if you do not want to change
the setting.
LEVEL - The cursor moves to a numeric value, which the dome uses to try to
maintain a certain light level. Changing the value of the Level setting will change the
video level to which the auto iris adjusts. This setting should be adjusted if the video
level in the auto iris mode is too bright or too dark. Move the joystick up or down to a
value. Press the Iris Open button to select the value, or press the Iris Close button if
you do not want to change the setting.
Pelco Manual C2422M (5/00)
9
BACKLIGHT COMPENSATION
Main Menu
Camera Menu
Backlight comp
Reset camera
<Gain/AGC>
<Auto-iris>
<Next>
Off
<Camera>
<Line Sync>
<Power Up>
<Other>
EXIT
Exit
There are two backlight compensation modes:
On - The dome uses the center 10 percent of the picture to adjust the iris. If there is a
bright light source outside of this area, it will wash out to white. The camera will
adjust the iris so that the object in the sensitive area is properly exposed.
Off - Backlight compensation is not activated.
To change the backlight compensation mode:
1. Program preset 95 (28). The main menu appears.
2. Position the cursor (>) beside Camera.
NON-SENSITIVE AREA
3. Press the Iris Open button to enter the Camera menu.
SENSITIVE
AREA
4. Position the cursor (>) beside Backlight Comp.
5. Press the Iris Open button. The cursor moves to the
right, beside the word On or Off.
6. Move the joystick up or down to toggle between On
and Off.
7. SELECT - Press the Iris Open button on your key-
board to select your choice.
CANCEL - Press the Iris Close button if you do not want to change the setting.
GAIN/AGC
Main Menu
Camera Menu
Gain/AGC Menu
Backlight comp
Reset camera
<Gain/AGC>
<Auto-iris>
<Next>
Off
<Camera>
AGC mode
Gain
Exit
Auto
10
<Line Sync>
<Power Up>
<Other>
EXIT
Exit
Gain - The amount of amplification the camera places on its video information in order to
obtain a full 1-volt peak-to-peak video signal out.
AGC - Automatic Gain Control.
AGC MODE
There are two AGC settings :
Auto Mode - Automatically adjusts the gain.
Off Mode - In the off mode the AGC is off.
To change the AGC mode:
1. Program preset 95 (28). The main menu appears.
2. Position the cursor (>) beside Camera.
3. Press the Iris Open button to enter the Camera menu.
4. Position the cursor (>) beside Gain/AGC.
5. Press the Iris Open button to enter the Gain/AGC menu.
6. Position the cursor (>) beside AGC mode.
7. Press the Iris Open button. The cursor moves to the right, beside the word Auto or Off.
8. Move the joystick up or down to choose between Auto or Off.
9. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL - Press the Iris Close button if you do not want to change the setting.
10
Pelco Manual C2422M (5/00)
GAIN
The gain adjusts the signal level of the video output. Increasing the gain in low light
conditions will increase the level of noise in the picture.
To change the gain:
1. Program preset 95 (28). The main menu appears.
2. Position the cursor (>) beside Camera.
3. Press the Iris Open button to enter the Camera menu.
4. Position the cursor (>) beside Gain/AGC.
5. Press the Iris Open button to enter the Gain/AGC menu.
6. Position the cursor (>) beside Gain.
7. Press the Iris Open button. The cursor moves to the right, beside the current gain
setting (a numeric value).
8. Move the joystick up or down to change the gain. As you change the gain, the picture
on your monitor gets brighter or darker.
9. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL - Press the Iris Close button if you do not want to change the setting.
LIMIT STOPS
Main Menu
Other Menu
<Camera>
Auto flip
Limit stops
Park time minutes
Scan speed deg/s 25
Exit
On
On
0
<Line Sync>
<Power Up>
<Other>
EXIT
There are two types of limit stops:
Manual limit stops - A manual (joystick) pan operation stops when a limit stop is reached.
Scan limit stops - The dome reverses direction during random, frame, or auto
scanning when a limit stop is reached.
Limit stops are controlled by software. To set limit stops:
1. Turn on the limit stop mode.
2. Program the limit stops.
TURNING LIMIT STOPS ON OR OFF
To change the limit stop mode:
1. Program preset 95 (28). The main menu appears.
2. Position the cursor (>) beside Other.
3. Press the Iris Open button to enter the Other menu.
4. Position the cursor (>) beside Limit Stops.
5. Press the Iris Open button. The cursor moves to the right, beside the word On or Off.
6. Move the joystick up or down to toggle between On and Off.
7. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL - Press the Iris Close button if you do not want to change the setting.
PROGRAMMING LIMIT STOPS
Manual Limit Stops
Refer to the documentation for your control system for programming presets, and then do
the following:
1. Make sure limit stops are turned ON, and then exit the menu.
2. Push the joystick left until you reach the limit you want the camera to go to on the left.
3. Program preset 90 (23).
NOTE: Programming
preset 90 (23) disables the
manual limit stops until
preset 91 (24) is set.
4. Push the joystick right to the limit you want the camera to go to on the right.
5. Program preset 91 (24).
Setting presets 90 (23) and 91 (24) to the same point disables manual limit stops.
Pelco Manual C2422M (5/00)
11
Scan Limit Stops
Refer to the documentation for your control system for programming presets, and then do
the following:
1. Make sure limit stops are turned ON, and then exit the menu.
2. Push the joystick left until you reach the limit you want the camera to go to on the left.
3. Program preset 92 (25).
4. Push the joystick right to the limit you want the camera to go to on the right.
5. Program preset 93 (26).
NOTE: On power-up, the
auto scan tilt angle will be
whatever angle the camera
was at when the right scan
limit was set.
Setting presets 92 (25) and 93 (26) to the same point disables scan limit stops.
LINE SYNCHRONIZATION
Main Menu
Line Sync Menu
<Camera>
<Line Sync>
<Power Up>
<Other>
Line sync
Line sync phase
Exit
On
0
EXIT
If cameras are out of phase with each other, they may produce what appears to be vertical roll
when switching between cameras.
There are two settings for line synchronization:
On - Adjust the synchronization of the power line voltage so that it is in phase with other
cameras.
Off - The dome synchronizes to an internal clock.
To change the line synchronization settings:
1. Program preset 95 (28). The main menu appears.
2. Position the cursor (>) beside Line Sync.
3. Press the Iris Open button. The Line Sync menu appears.
4. Position the cursor (>) beside one of the choices. Press the Iris Open button.
LINE SYNC - The cursor moves to one of two choices: ON or OFF. Move the joystick up or
down to toggle between them. Press the Iris Open button to select the choice. If you changed to
OFF, the camera may reset itself as it adjusts to the new synchronization. If the camera resets,
it will only affect the line synchronization. It will not change any other camera parameters, such
as auto focus or auto iris. Press the Iris Close button if you do not want to change the setting.
LINE SYNC PHASE - The cursor moves to a numeric value. Move the joystick up or down
to change the value. Press the Iris Open button to select the choice. The value represents the
phase angle in tenths of a degree between 0 degrees and 350 degrees. For example, 900 is
90 degrees, 1200 is 120 degrees, and 2400 is 240 degrees. Press the Iris Open button on
your keyboard to select your choice. The Line Sync setting will change to ON. The camera
may reset or the picture on your monitor may wiggle when you change the phase angle. If the
camera resets, it will only affect the line synchronization. It will not change any other camera
parameters, such as auto focus or auto iris. Press the Iris Close button if you do not want to
change the setting.
12
Pelco Manual C2422M (5/00)
PARK TIME MINUTES
Main Menu
Other Menu
<Camera>
Auto flip
Limit stops
Park time minutes
Scan speed deg/s 25
Exit
On
On
0
<Line Sync>
<Power Up>
<Other>
EXIT
This feature causes the dome to park at preset 1 after a programmed number of minutes of
control inactivity. The time can be set from 1 minute to 720 minutes (12 hours), or it can be set
to zero, which disables this feature.
To change the park time:
1. Program preset 95 (28). The main menu appears.
2. Position the cursor (>) beside Other.
3. Press the Iris Open button to enter the Other menu.
4. Position the cursor (>) beside Park Time Minutes.
5. Press the Iris Open button. The cursor moves to the right, beside the current park time.
6. Move the joystick up or down to change the park time.
7. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL - Press the Iris Close button if you do not want to change the setting.
NOTE: Preset 1 must be
programmed for the dome to
park.
POWER-UP MODE
Main Menu
Power-Up Menu
<Camera>
<Line Sync>
<Power Up>
<Other>
Power Up
Exit
Default
EXIT
This feature lets the dome resume a desired condition following power-up. The menu
includes the following choices.
Default -
On power-up, the dome goes through a configuration cycle and stops at
zero reference, showing “Configuration Done,” address, and mode
settings on the screen.
Park -
The dome moves to preset 1 when the power-up sequence finishes.
The only text on the screen is the preset label (if any is programmed).
Scan Auto - The dome initiates scan mode when the power-up sequence finishes.
Again, there is no text.
Scan Frame - The dome initiates a frame scan when the power-up sequence finishes.
Scan Rand - The dome initiates a random scan when the power-up sequence finishes.
The default setting is Default.
To select the power-up mode:
1. Program preset 95 (28). The main menu appears.
2. Position the cursor (>) beside Power Up Mode.
3. Press the Iris Open button to enter the Power Up Mode menu.
4. Press the Iris Open button to move the cursor to the right.
5. Move the joystick up or down to cycle through the selections. Stop on the item you
want to select.
6. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL - Press the Iris Close button if you do not want to change the setting.
Pelco Manual C2422M (5/00)
13
RESET CAMERA
Main Menu
Camera Menu
Backlight comp
Reset camera
<Gain/AGC>
<Auto-iris>
<Next>
Off
<Camera>
<Line Sync>
<Power Up>
<Other>
EXIT
Exit
Resetting the camera returns the settings to their defaults.
Default Settings
Backlight comp
Gain/AGC
AGC mode
Gain
Off
Auto
10
Auto-iris
Mode
Level
Shutter speed
Auto focus mode
Sharpness
Auto
180
Auto
Auto
5
White balance
Auto white bal
White bal hue
Auto
26
When the camera is reset, the following settings are not changed: park time, auto flip
disable, and limit stops.
Turning off power to the Spectra Lite dome does not reset the camera. Camera settings are
retained in memory. When the power is turned back on, the settings will be the same as
they were when the power was turned off.
To reset the camera:
1. Program preset 95 (28). The main menu appears.
2. Position the cursor (>) beside Camera.
3. Press the Iris Open button to enter the Camera menu.
4. Position the cursor (>) beside Reset Camera.
5. Press the Iris Open button to reset the camera.
14
Pelco Manual C2422M (5/00)
SCAN SPEED
Main Menu
Other Menu
<Camera>
Auto flip
Limit stops
Park time minutes
Scan speed deg/s 25
Exit
On
On
0
<Line Sync>
<Power Up>
<Other>
EXIT
The scan speed is adjustable from 1-40 degrees per second. This occurs in three scan
modes: auto, random, and frame scan.
To change the scan speed:
1. Program preset 95 (28). The main menu appears.
2. Position the cursor (>) beside Other.
3. Press the Iris Open button to enter the Other menu.
4. Position the cursor (>) beside Scan Speed deg/s.
5. Press the Iris Open button. The cursor moves to the right, beside the number of degrees.
6. Move the joystick up or down to toggle through the number of degrees (1-40) until you
reach the number you want. (If set on a low number, the scan will appear to barely
move but is still functioning.)
7. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL - Press the Iris Close button if you do not want to change the setting.
SHARPNESS
Main Menu
Camera Menu
Next Menu
Sharpness Menu
Shutter speed
Auto focus mode
<Sharpness>
<White balance>
Prev (back to prev. menu)
Exit
Auto
Auto
Backlight comp
Off
<Camera>
<Line Sync>
<Power Up>
<Other>
Reset camera
<Gain/AGC>
<Auto-iris>
<Next>
Sharpness
Exit
5
EXIT
Exit
Do the following to manually adjust the sharpness of the picture:
1. Program preset 95 (28). The main menu appears.
2. Position the cursor (>) beside Camera.
3. Press the Iris Open button to enter the Camera menu.
4. Position the cursor (>) beside Next.
5. Press the Iris Open button to go to the Next menu.
6. Position the cursor (>) beside Sharpness.
7. Press the Iris Open button to enter the Sharpness menu.
8. Press the Iris Open button. The cursor moves to the right, beside the sharpness value.
9. Move the joystick up or down to toggle through the available sharpness values. As the
numeric value changes, the sharpness of the picture on the monitor changes.
10. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL - Press the Iris Close button if you do not want to change the setting.
Pelco Manual C2422M (5/00)
15
SHUTTER SPEED
Main Menu
Camera Menu
Next Menu
Backlight comp
Reset camera
<Gain/AGC>
<Auto-iris>
<Next>
Off
Shutter speed
Auto focus mode Auto
<Sharpness>
<White balance>
Prev (back to prev. menu)
Exit
Auto
<Camera>
<Line Sync>
<Power Up>
<Other>
EXIT
Exit
There are several shutter speed settings:
Auto
1/125
1/500
1/1000
1/2000
1/4000
1/10,000
In the Auto setting the camera controls the shutter speed automatically. Increasing the
shutter speed lowers the light sensitivity, but rapidly moving objects will be less blurred as
the speed is increased.
To change the electronic shutter speed settings:
1. Program preset 95 (28). The main menu appears.
2. Position the cursor (>) beside Camera.
3. Press the Iris Open button to enter the Camera menu.
4. Position the cursor (>) beside Next.
5. Press the Iris Open button to go to the Next menu.
6. Position the cursor (>) beside Shutter Speed.
7. Press the Iris Open button.
8. The cursor moves to the right, beside the current shutter speed.
9. Move the joystick up or down to choose the shutter speed.
10. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL - Press the Iris Close button if you do not want to change the setting.
16
Pelco Manual C2422M (5/00)
WHITE BALANCE
Main Menu
Camera Menu
Next Menu
White Balance Menu
Backlight comp
Off
Shutter speed
Auto focus mode
<Sharpness>
<White balance>
Prev (back to prev. menu)
Exit
Auto
Auto
<Camera>
<Line Sync>
<Power Up>
<Other>
Reset camera
<Gain/AGC>
<Auto-iris>
<Next>
Auto white bal
White bal hue
Exit
Auto
26
EXIT
Exit
The settings for white balance are as follows:
Auto
White balance hue
To change the white balance settings:
1. Program preset 95 (28). The main menu appears.
2. Position the cursor (>) beside Camera.
3. Press the Iris Open button to enter the Camera menu.
4. Position the cursor (>) beside Next.
5. Press the Iris Open button to go to the Next menu.
6. Position the cursor (>) beside White Balance.
7. Press the Iris Open button. The White Balance menu appears.
8. Position the cursor (>) beside one of the following choices and press the Iris Open button.
AUTO WHITE BALANCE - The cursor moves to one of two choices: Auto or Off.
Move the joystick up or down to toggle between them. Press the Iris Open button to
select the choice, or press the Iris Close button if you do not want to change the setting.
WHITE BALANCE HUE - Adjust the color by moving the joystick up or down to a
value between 1 (blue end of the spectrum) and 99 (red end). Hold the joystick up or
down to fast forward or fast reverse through the values. As you change the value, you
can see the color change on your monitor. Press the Iris Open button to select the
value, or press the Iris Close button if you do not want to change the setting. If Auto
White Balance is on, it changes to off when you select a new value.
Pelco Manual C2422M (5/00)
17
MAINTENANCE
DOME CLEANING
Clean the acrylic dome as necessary to maintain a clear picture. Be careful not to scratch the
surfaces of the dome.
Exterior Surface - Clean the dome’s exterior surface with a nonabrasive cleaning cloth and
cleaning agent that is safe for acrylic. Either liquid or spray cleaner/wax suitable for fine
furniture is acceptable.
Interior Surface (Except Chrome or Gold) - Clean the same as the exterior surface.
Interior Surface (Chrome or Gold) - The inside surface of a chrome or gold dome is easily
scratched. Use the following precautions to maintain the dome’s surface.
1. Always handle the dome from the outside of its circular flange.
2. Never touch the coated inside surface. The acid in your fingerprints will eventually etch
the coating if the fingerprints are not carefully removed according to the recommended
cleaning procedure in item 5.
3. If dust or other contaminants accumulate on the dome’s interior, remove the debris with
compressed air. Compressed air cans are available from photographic equipment or
electronic supply dealers.
4. If heavy residue accumulates and cannot be removed with air pressure, rinse with water
and immediately dry with air pressure so that water spots will not remain. Avoid wiping
the coated surface with direct hand pressure - it will easily abrade unless extreme care
is taken. Once scratched, the dome cannot be recoated.
5. If internal wiping is necessary, avoid hand rubbing. Instead, make a wick as follows:
Use a very soft paper towel. Roll a section into a tightly wound tube. Tear the tube in
half, and wet the fuzzy end of the wick with a solution of isopropyl alcohol diluted with
water. Hold the dome with its opening facing downward and wipe the interior of the
dome with the wet end of the wick. Use a circular motion, starting from the outside and
spiraling into the center. Use a new wick for each two passes over the dome.
SERVICE MANUAL
If you need to service your unit, obtain a service manual in one of the following ways:
•
•
Contact Pelco’s Literature Department and request service manual C1455SM-B.
18
Pelco Manual C2422M (5/00)
SPECIFICATIONS
MECHANICAL
Pan Movement:
360° continuous pan rotation
Vertical Tilt:
Unobstructed +2° to -92°
Manual Pan/Tilt Speeds*
Pan:
Tilt:
0.5°-80°/sec manual operation, 150°/sec turbo
0.5°-40°/sec
Preset Speeds
Pan:
250°/sec
Tilt:
200°/sec
* For variable-speed operation an appropriate controller is required. With fixed-speed
controllers, pan/tilt speed is 24°/sec. The CM6700 controller with the KBD200 keyboard
has programmable fixed speeds.
CAMERA
Signal Format:
NTSC (model DD5TAC)
PAL (model DD5TAC-X)
2:1 interlace
Scanning System:
Image Sensor:
Effective Pixels
NTSC:
1/4-inch interline transfer CCD
510 (H) x 492 (V)
500 (H) x 582 (V)
PAL:
Horizontal Resolution
NTSC:
PAL:
380 TV lines
370 TV lines
Lens
Minimum f-stop:
Focal Length:
Zoom Ratio:
Digital Slow Shutter:
Horizontal
F1.6
3.9 mm to 63 mm optical
16 optical zoom
Auto/manual speed selection
Angle of View:
MTBF:
Focus:
44° (at 3.9 mm wide zoom), 3° (at 63 mm telephoto zoom)
>1 million cycles at room temperature (zoom, focus, irs)
Automatic and manual override
Sensitivity:
Sync System:
White Balance:
Shutter Speed
NTSC:
1 lux at f1.6 at signal level of 40 IRE, gain high (AGC on)
AC line lock, phase adjustable via remote control*
Automatic with manual override*
Automatic (electronic iris)/manual
1/60-1/10,000*
PAL:
1/50-1/10,000*
Iris Control:
Gain Control:
Video Output
NTSC:
Automatic with manual override*
Automatic with manual override*
.714V ± .07V (100 IRE ± 10 IRE)
PAL:
.7V ± .07V
Signal to Noise Ratio:
>46 dB
* Manual control of camera setup functions can be done with CM6700, CM8500, CM9500,
CM9760 and MPT9500 controllers, but not with CM7500, MPT9000 or KBD9000 controllers.
(Design and product specifications subject to change without notice.)
Pelco Manual C2422M (5/00)
19
PRODUCT WARRANTY AND RETURN INFORMATION
WARRANTY
Pelco will repair or replace, without charge, any merchandise proved defective in material or
workmanship for a period of one year after the date of shipment.
If
a
warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or
(559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following
information:
1. Model and serial number
Exceptions to this warranty are as noted below:
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number
3. Details of the defect or problem
•
•
•
Five years on FT/FR8000 Series fiber optic products.
Three years on Genex® Series products (multiplexers, server, and keyboard).
If there is a dispute regarding the warranty of a product which does not fall under the
warranty conditions stated above, please include a written explanation with the product
when returned.
Three years on Camclosure® and fixed camera models, except the CC3701H-2,
CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and MC3651H-2X camera models,
which have a five-year warranty.
Method of return shipment shall be the same or equal to the method by which the item was
received by Pelco.
•
•
Two years on standard motorized or fixed focal length lenses.
Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series
fixed dome products.
RETURNS
In order to expedite parts returned to the factory for repair or credit, please call the factory at
(800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned
for credit, and RA number if returned for repair).
•
Two years on Spectra®, Esprit®, ExSite™, and PS20 scanners, including when used in
continuous motion applications.
•
•
Two years on Esprit® and WW5700 Series window wiper (excluding wiper blades).
All merchandise returned for credit may be subject to a 20% restocking and refurbishing
charge.
Eighteen months on DX Series digital video recorders, NVR300 Series network video
recorders, and Endura™ Series distributed network-based video products.
Goods returned for repair or credit should be clearly identified with the assigned CA or RA
number and freight should be prepaid. Ship to the appropriate address below.
•
•
One year (except video heads) on video cassette recorders (VCRs). Video heads will be
covered for a period of six months.
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:
Six months on all pan and tilts, scanners or preset lenses used in continuous motion
applications (that is, preset scan, tour and auto scan modes).
Service Department
Pelco
3500 Pelco Way
Clovis, CA 93612-5699
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco
shipment. All goods requiring warranty repair shall be sent freight prepaid to Pelco, Clovis,
California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident
are not covered under this warranty.
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are
instructed to return goods to the USA, you may do one of the following:
If the goods are to be sent by a COURIER SERVICE, send the goods to:
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from
the specific use or application made of the Products. Pelco’s liability for any claim, whether
based on breach of contract, negligence, infringement of any rights of any party or product
liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for
such Products. In no event will Pelco be liable for any special, incidental or consequential
damages (including loss of use, loss of profit and claims of third parties) however caused,
whether by the negligence of Pelco or otherwise.
Pelco
3500 Pelco Way
Clovis, CA 93612-5699 USA
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:
Pelco c/o Expeditors
473 Eccles Avenue
The above warranty provides the Dealer with specific legal rights. The Dealer may also have
additional rights, which are subject to variation from state to state.
South San Francisco, CA 94080 USA
Phone: 650-737-1700
Fax: 650-737-0933
REVISION HISTORY
Manual # Date
C2422M 5/00
Comments
Original version.
Pelco, the Pelco logo, Camclosure, Esprit, Genex, Legacy, and Spectra are registered trademarks of Pelco.
Endura and ExSite are trademarks of Pelco.
© Copyright 2000, Pelco.
All rights reserved. U.S. Patent No. 5,931,432.
20
Pelco Manual C2422M (5/00)
|