HE225A,B and HE265A,B
Bypass Flow-Through
Humidifier
whole-house air quality system
PRODUCT DATA
FEATURES/BENEFITS
•
Antimicrobial coating on pad prevents the surface
growth and migration of bacteria, mold, fungus and
algae on the humidifier pad.
•
•
Bold new look with blue and white styling.
Proven technology used for high performance
humidification and enhanced comfort.
•
•
Preassembled for quicker installation.
Small footprint, light weight and reversible
components allow easy mounting on either warm air
supply or return air duct of any forced air furnace.
•
•
•
•
Interior components designed for quick maintenance
and service.
Includes easy-to-use humidity control that mounts on
the wall or duct for more flexible installation.
Continuous flushing reduces the frequency of
maintenance in a hard water installation.
AIRWATCH™ Indicator can be installed to remind
homeowner to change humidifier pad.
APPLICATION
•
Five-year warranty.
The Enviacaire Elite HE225A,B and HE265A,B Bypass Flow-
through Humidifiers use the warm air furnace blower to
provide humidification for the whole house.
® U.S. Registered Trademark
Copyright © 2000 Honeywell
•
All Rights Reserved
68-0244
HE225A,B AND HE265A,B BYPASS FLOW-THROUGH HUMIDIFIER
Standard:
Air Conditioning and Refrigeration Institute Tested:
Standard 610.
1
1
9-1/8 (232)
-7
/1
6 (29
0
)
Models:
HE225A TRADELINE® and HE265A TRADELINE®
Bypass Flow-through Humidifier package includes
humidifier pad, mounting template, self-piercing saddle
valve, 24 Vac transformer, H8908B Convertible
Humidity Control.
1
2 (3
05)
HE225B TRADELINE® and HE265B TRADELINE®
Bypass Flow-through Humidifier package includes
humidifier pad, mounting template, self-piercing saddle
valve, 24 Vac transformer, H1008AAutomatic Humidity
12-7/16
Control with HumidiCalc™ Software.
(316)
Accessories:
Current Sensor Relay, part no. 32001754-001.
C7089H Outdoor Temperature Sensor.
H8908B Convertible Humidity Control.
H1008A Automatic Humidity Control with HumidiCalc+™
Software (software calculates dewpoint to prevent
moisture condensation).
HC22E Antimicrobial Humidifier Pad (HE225A,B only).
HC26E Antimicrobial Humidifier Pad (HE265 A,B only).
HumidiCalc+™ Humidifier Sizing Software (software
13-9/16
(345)
6 (152)
DIAMETER
M14818
calculates required humidifier capacity for application).
PC8900 Control.
S688 Sail Switch.
Fig. 1. Dimensions of HE225A,B in in. (mm).
INSTALLATION
9-1/4 (235)
12 (305)
WARNING
Hazardous Voltage.
13-9/16 (345)
Can cause personal injury or equipment damage.
Do not cut or drill into any air conditioning line or
electrical accessory.
CAUTION
15-5/16
(390)
Freezing Water, Flooding or
Static Pressure Hazard.
Can cause water damage to home or permanent
equipment damage.
•
•
The humidifier must be located where the ambient
temperature is above 32°F and below 160°F (0°C
and 71°C).
Be sure supply plenum static pressure is no
greater than 0.3 in. w.c. and water pressure is no
greater than 125 psi.
16-3/4
(425)
6 (152)
DIAMETER
IMPORTANT
To assure optimal product performance, be sure the
M14819
template is level before marking location.
Fig. 2. Dimensions of HE265A,B in in. (mm).
1. Determine the best location for the humidifier and draw
a level line on the plenum. See Fig. 3.
Approvals:
Underwriters Laboratories Inc. Listing: 56 BL.
Canadian Underwriters Laboratories Inc. Listing: 56 BL.
68-0244
3
HE225A,B AND HE265A,B BYPASS FLOW-THROUGH HUMIDIFIER
11. Reinstall the humidifier pad assembly in the humidifier
housing.
NOTE: Be sure the water feed tube is not pinched or
kinked.
HORIZONTA
12. Hinge the cover in place and secure with the
thumbscrew located at the bottom of the cover.
WATER
FEED NOZZLE
HIGHBOY
DOWN
FLO
HUMIDIFIER
PAD ASSEMBLY
LOWBOY
FRAME
M12248C
COVER
SIDEWALL
Fig. 3. Typical humidifier installation locations.
IMPORTANT
Mount the humidifier at least 3 in. (76 mm) above
the furnace jacket to allow adequate space for the
solenoid valve and drain line. Check that there is
adequate space above the humidifier to remove and
install the humidifier cover.
2. Tape the template in position and trace around the
template.
3. Remove the template and carefully cut the rectangular
HUMIDIFIER
HOUSING
opening.
WATER
BY-PASS SIDEWALL
FEED TUBE
M14672
4. Disassemble the humidifier; remove the cover and take
out the humidifier pad assembly. See Fig. 4.
Fig. 4. Humidifier components.
NOTE: Sidewalls are interchangeable for either left or
right by-pass installation. To change direction,
remove the screws holding each sidewall,
switch sidewall locations and reinstall the
screws.
WIRING THE HUMIDIFIER
CAUTION
5. Position the humidifier housing in the opening (be sure
it is level), so the locking tabs are in place on the lower
sheet metal edge of the opening.
6. Secure the humidifier housing to the opening at the top
and bottom using sheet metal screws.
7. Locate the other plenum and cut an opening for a 6 in.
(152 mm) collar.
8. Install the 6 in. (152 mm) collar.
Hazardous Voltage.
Can cause personal injury or equipment damage.
•
Disconnect the power supply before installing or
servicing.
•
On multispeed blower applications, do not wire the
high voltage side of the transformer to the same
power source that services the furnace blower.
Premature transformer burnout may occur.
NOTE: Be sure to install a duct damper for summer
shutoff on systems with air conditioning.
All wiring must comply with applicable local codes,
ordinances and regulations.
9. Install a 6 in. (152 mm) diameter duct from the collar to
1. Mount the transformer in a convenient location.
2. Connect wires to the 120V side of the transformer.
3. Wire the humidifier solenoid valve, current sensing
relay, or sail switch, humidity control and transformer.
Refer to the humidity control installation instructions for
mounting and wiring information.
the humidifier.
NOTE: Some installations require a 90° elbow
attachment to the collar.
10. Seal the duct connections with duct tape.
NOTE: Select models of fan centers include humidifier taps
so the current sensing relay or sail switch is not
needed.
NOTE: To avoid sagging and stress on the humidifier,
add support when ducting is longer than
4 ft (120 cm).
68-0244
4
HE225A,B AND HE265A,B BYPASS FLOW-THROUGH HUMIDIFIER
PLUMBING THE SADDLE VALVE
OPERATING THE HUMIDIFIER
DITY
ING
SETT
15%
20%
25%
30%
35%
40%
HUMI
OOR
OUTD
ERAT
URE
TEMP
-30 °C
-25 °C
-20 °C
-10 °C
-5 °C
-20 °F
-10 °F
0
+10
+
Over
2
0
°F
°F
Hot or cold water, either hard or softened, can be used in the
humidifier.
The HE225A and HE265A
Humidifiers are controlled by
the Convertible Humidity
20 °F
l
ontro
idity C
Hum
Régula
°C
Over
0
°F
idité
'hum
teur d
1. Use the self-piercing saddle valve (included) to tap into
Control that is installed either
on an interior wall in the living
area or on the return air duct.
Choose the humidity control
setting using the combination
relative humidity/outdoor
the water supply line at an appropriate location.
IMPORTANT
•
The saddle valve is not designed to regulate water
flow. The valve is either open or closed.
To prevent debris from clogging the solenoid inline
filter, be sure to install the saddle valve handle
pointing toward the ceiling.
•
M14694
temperature setting scale on the
humidity control dial. Match the
H8908A
dial setting to the outdoor temperature for optimizing the
NOTE: Lightly clean the copper tubing ends with fine
sandpaper before making any connections.
humidity level while reducing the moisture condensation on
inside windows. Table 5 can also be used to adjust the
humidity control to the recommended setting.
2. Use 1/4 in. O.D. copper tubing and connect the saddle
valve to the inlet side of the solenoid valve.
NOTE: As the outside temperature drops, the
recommended setting is lowered to accommodate
the effects of dewpoint. These settings should
reduce the accumulation of moisture and ice on the
windows and in other areas of the house.
CAUTION
Hazardous Voltage.
Can cause personal injury or equipment damage.
Do not use any line connected to an air conditioner.
Some indoor activities such as cooking, showering and
clothes drying can cause excessive levels of humidity and
start the accumulation of moisture on the windows.
a. Place the brass compression nut over the copper
tubing.
NOTE: If this condition persists for more than a few hours,
set the humidity control to the lowest setting to turn
off the humidifier. If the condition does not improve,
ventilate your home to remove the moisture.
NOTE: Do not over tighten the compression nut.
Moderate tightness prevents leaking.
b. Slide the brass ferrule over the tubing.
c. Insert the tubing into the solenoid valve fitting and
support the valve while tightening the
compression nut.
The Enviracaire Elite HE225B
and HE265B Humidifiers are
controlled by the Honeywell
H1008A Automatic Humidity
Control with HumidiCalc+
3. Connect a 1/2 in. (13 mm) drain tube to the humidifier
drain fitting and run to a suitable drain.
Software. The automatic
humidity control is mounted in
the return air duct where it can be
exposed to the air stream of the
return air. The HumidiCalc+ Software
NOTE: Slope the drain tube downward for correct
drainage.
M12817
H1008A
inside the automatic humidity control
CHECKING THE INSTALLATION
is designed to automatically adjust the humidity level based
on indoor temperature and humidity, inferred or measured
outdoor temperature, and the setting of the frost factor dial.
The frost factor allows for variations in furnace size, window
insulation and average daily climate temperature.
Use the following procedure to check out the humidifier
installation:
1. Open the saddle valve.
2. Set the thermostat setpoint to 10°F (6°C) above the
room temperature.
The Automatic Humidity Control with HumidiCalc+ Software
requires an initial adjustment period. Set the frost factor dial
on 5 and use Table 6 to adjust the frost factor—only one
setting at a time—increasing the dial setting for more
humidity, or reducing the setting if moisture develops on
inside windows. For more precise humidity adjustment, set
the frost factor between dial settings. Allow two days for the
humidity level to subside before making further adjustments.
Once the proper setting has been found, no further
adjustment is needed. HumidiCalc+ Software takes over
and makes any future adjustments caused by varying outdoor
temperatures, thus reducing moisture build-up on windows
while maintaining the optimal humidity level.
NOTE: The furnace blower must be on for the
humidifier to operate.
3. Set the Convertible Humidity Control to a high setting,
or place the H1008A Automatic Humidity Control in the
Test position.
4. Observe the water running out of the drain line to be
sure the humidifier is working.
5. Check for leaks.
6. Reset the thermostat and Convertible Humidity Control
to a comfortable setting, or the Automatic Humidity
Control to the desired frost factor setting, for automatic
operation.
68-0244
5
HE225A,B AND HE265A,B BYPASS FLOW-THROUGH HUMIDIFIER
Table 5. Recommended Convertible Humidity Control Settings.
At Outside Temperature
-20°F (-29°C)
Recommended Setting
At Outside Temperature
+10°F (-12°C)
Recommended Setting
15
20
25
30
35
40
-10°F (-23°C)
+20°F (-7°C)
0°F (-18°C)
Above 20°F (-7°C)
Table 6. Recommended Frost Factor Settings.
Recommended Adjustment
Humidity Level
Insufficient humidity
Increase the frost factor dial by one setting.
Decrease the frost factor dial by one setting.
Condensation on windows
Every 1 to 3 Months
OPERATION
(Depending on Water Quality)
The HE225A,B and HE265A,B Humidifiers use the principle
that vapor (evaporated water) is created when warm air blows
over a water soaked area. As the vapor circulates, the relative
humidity rises.
Use the following procedure to clean the humidifier:
1. Disconnect the power and turn off the humidifier water
supply.
2. Remove the humidifier cover. See Fig. 5.
The humidity control monitors the relative humidity and
activates the humidifier accordingly. The humidifier has a
water supply that disburses water over an antimicrobial
humidifier pad. The warm dry air from the furnace passes
over the humidifier pad and collects moisture and them
circulates it through the house.
WATER
FEED NOZZLE
Humidified air feels warmer and more comfortable so the
homeowner may be able to lower the thermostat heating
setpoint and save money on heating fuel bills. The end result
is that the humidifier gives the homeowner a comfortable
environment that is also energy efficient.
HUMIDIFIER
PAD ASSEMBLY
FRAME
COVER
SIDEWALL
MAINTENANCE
A regular maintenance program prolongs the life of the
humidifier and provides a more comfortable environment.
Either hard or soft water can be used in the humidifier.
Frequency of cleaning depends on the condition of the water.
CAUTION
Voltage Hazard.
Can cause electrical shock and equipment
damage.
HUMIDIFIER
HOUSING
Disconnect power supply before installing or
servicing.
WATER
FEED TUBE
BY-PASS SIDEWALL
M14672
Fig. 5. Location of humidifier parts.
IMPORTANT
Never oil any part of the humidifier.
3. Remove the humidifier pad assembly from the
humidifier by grasping the tray and pulling it toward
you.
4. Pull one side of the humidifier pad assembly frame
toward you and remove the tray from the frame.
5. Gently pinch the water nozzle catches inward until the
water nozzle can be lifted off the tray.
6. Slide the antimicrobial humidifier pad out of the frame.
7. Carefully scrape any mineral deposits from the tray and
frame. Be sure the frame drain hole has nothing
blocking it.
68-0244
6
HE225A,B AND HE265A,B BYPASS FLOW-THROUGH HUMIDIFIER
8. Check the humidifier pad and if excessive mineral
IMPORTANT
Be sure the humidifier power is off.
deposits are present, replace with a new antimicrobial
pad.
9. Disconnect the tube from the drain fitting on the bottom
of the humidifier housing.
10. Clean the drain fitting, if necessary.
11. Bend the drain tube to loosen any mineral deposits.
12. Flush the drain tube with pressurized water (a running
tap) to clean the tube.
Beginning of Humidification Season
Refer to the Checkout Procedure section to complete the
humidifier startup.
Vacation
13. Reattach the drain tube to the drain fitting.
14. Slide the humidifier pad back into the frame.
When leaving on vacation, turn off the humidifier water supply
and the humidity control. When returning from vacation, turn
on the humidifier water supply and reset the humidity control
to restart the humidifier.
IMPORTANT
To maintain the antimicrobial properties of the
humidifier, use only a Honeywell HC22E or HC26E
Antimicrobial Pad. See Table 8 List of Replacement
Parts for appropriate pad. Be sure the marked side
of the antimicrobial humidifier pad is facing up for
proper performance.
CHECKOUT PROCEDURE
After winter startup or servicing, use the following procedure
to check the humidifier operation:
15. Snap the water nozzle back on the tray.
16. Reattach the tray to the frame.
17. Place the humidifier pad assembly in the humidifier
housing and press until the assembly is completely
seated. Be careful not to pinch or kink the water feed
tube.
1. Turn on the humidifier power and water supply.
2. Turn the Convertible Humidity Control to the highest
setting, or place the H1008A Automatic Humidity
Control in the Test position and set the thermostat to
10°F (6°C) above the room temperature.
3. Observe that water is flowing out of the drain hose.
18. Replace the humidifier cover.
19. Verify the humidifier operation by following the steps in
the Checkout Procedure section.
NOTE: The furnace blower must be on for the
humidifier to operate.
4. Reset the thermostat and Convertible Humidity Control
to a comfortable setting, or the H1008AAutomatic
Humidity Control to the desired frost factor setting, for
automatic operation.
End of Humidification Season
At the end of the heating season, follow steps 1 through 18
from the Every 1 To 3 Months section to clean the humidifier
and shut if off.
TROUBLESHOOTING
Refer to Table 7 for troubleshooting procedures.
Table 7. Troubleshooting Procedures.
Problem
What To Look For
What To Do
Low humidity
Furnace blower not operating
•
•
•
•
•
Reset circuit breaker or check for blown fuse.
Check that the furnace power is on.
Check all external wiring connections.
Check the humidity control setting.
Call a professional heating contractor.
Rapid air changes. Drafts (cold air
is dry and is an added load to the
humidifier).
•
•
•
•
Keep doors and windows closed.
Close fireplace damper when not in use.
Keep exhaust fan running time to a minimum.
Seal around doors and windows.
High humidity
Condensation on walls.
•
Turn humidity control and water off until condensation is
completely evaporated.
Heavy condensation on windows.
•
Turn humidity control down low enough to eliminate
condensation caused by moisture from bathing, mopping,
cooking, etc. If moisture persists, more ventilation is needed.
68-0244
7
HE225A,B AND HE265A,B BYPASS FLOW-THROUGH HUMIDIFIER
REPLACEMENT PARTS
Refer to Fig. 6 and Table 8 when ordering replacement parts.
10
4
9
8
3
4
0
0
2
0
5
0
10
11
12
3
OFF
5
6
6
0
ON
13
7
8
1
8
2
M14820
Fig. 6. Exploded view of humidifier parts.
68-0244
8
HE225A,B AND HE265A,B BYPASS FLOW-THROUGH HUMIDIFIER
Table 8. List Of Replacement Parts For HE220A,B, HE260A,B Humidifiers.
Exploded
View Number
Description
HE225 Part Number
32001612-002
32001613-002
32001611-003
32001619-001
HC22E1003
HE265 Part Number
32001626-002
32001627-002
32001611-004
32001630-001
HC26E1004
1
2
3
4
5
6
7
8
Side wall
Bypass side wall
Cover Assembly
PerfectFlo™ water distribution tray
Antimicrobial humidifier pad
Frame
32001621-001
32001615-001
32001639-002
32001632-001
32001615-001
32001639-002
Drain fitting
Solenoid valve assembly
(includes water feed tube and nozzle)
9
Saddle valve assembly
Transformer (10 VA)
32001616-001
32001652-001
H8908B1002
H1008A1008
32001616-001
32001652-001
H8908B1002
H1008A1008
10
11
12
Convertible Humidity Control
Automatic Humidity control with
HumidiCalc™+ Software
13
—
Base insert assembly, includes no. 8 above
32001625-003
32001752-001
32001625-004
32001752-001
Hardware Kit for Solenoid Assembly (same as Solenoid
valve assembly without the solenoid valve)
—
Current Sensing Relay
32001754-001
32001754-001
68-0244
9
68-0244
10
68-0244
11
IMPROVE YOUR INDOOR AIR WITH A COMPLETE
whole-house air quality system
ULTRAVIOLET AIR TREATMENT SYSTEM
• ZAP airborne germs.
• Kill most germs before they recycle
through your home.
• Prevent mold spores from growing on your
system cooling coils.
F300E ELECTRONIC AIR CLEANER
• TRAP airborne particles.
• Up to 99% efficient at capturing
airborne particles.
• Effectively REDUCES fungi, bacteria,
mold antigen, cat antigen and ragweed
pollen antigen that pass through system.
ENVIRACAIRE ELITE HUMIDIFIERS
• Moisturize parched air.
• Help maintain proper humidity to minimize
adverse health effects.
• Features special antimicrobial agent to prevent
surface growth and migration of bacteria, mold,
fungus and algae on the humidifier pad.
Honeywell offers one of the broadest families of home solutions in the
industry - ranging from thermostats, zoning, ventilation, air cleaning,
humidification to internet-enabled home control and wireless
... only from Honeywell.
M14757
Home and Building Control
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422
Home and Building Control
Honeywell Limited-Honeywell Limitée
35 Dynamic Drive
Scarborough, Ontario
M1V 4Z9
Printed in U.S.A. on recycled
paper containing at least 10%
68-0244 G.H. 11-00
post-consumer paper fibers.
|