USE & CARE INSTRUCTIONS  
S
tart  
Ultrasonic Digital  
Humidifier  
Remanufactured  
English  
Spanish  
E - 1  
S - 1  
Model No. R3010  
30-Day Limited Warranty  
1.866.603.5900  
Date Purchased  
month ________  
year _________  
E-1  
 
WARNINGS  
This product should be used only in accordance with the specifications outlined in this manual.  
Usage other than what has been specified here may result in serious injury.  
Make sure the unit is unplugged.  
Disassembly, repair or remodeling by an unauthorized person may result in serious harm.  
Do not use if plug is damaged or loose.  
Keep this product out of the reach of children and away from pets.  
Be careful not to put water in the humidity spout.  
Before filling or cleaning the unit, make sure it is unplugged.  
Once the humidifier has been turned on, do not move it.  
Do not move when in operation.  
Do not remove the water tank from the unit while it is on.  
Do not handle the adapter plug with wet hands.  
Do not excessively bend, twist or pull the power cord.  
Avoid placing this product where the humidity is pointed directly at an electrical object.  
Do not directly inhale the humidity.  
Do not place this product on a sloped or unstable surface.  
When not in use, unplug the unit.  
Do not fill the water tank with hot or boiling water.  
Do not use this product in direct sunlight, or near a gas stove or heater.  
Do not use if the water tank becomes cracked or damaged.  
Do not keep this product running for an extended period of time.  
Do not clean the unit or water tank with detergents or chemicals of any kind.  
Do not use this product near any other electronic device.  
Do not cover the humidity opening at any time during use.  
Do not use this product near a sink.  
2. Open the tank lid, turning it to  
the left.  
1. Separate the tank from the body  
of the unit.  
3. Pour cool, clean water directly  
into the tank. Do not pour anything  
but water into the water tank.  
4. Close the tank lid, turning it to  
the right.  
Do not drink water from the water tank.  
Do not place this product on an absorbent surface.  
Do not pour anything but water into the water tank.  
Failure to comply with the warnings listed above may result in electric shock or serious injury.  
5. Attach the tank to the body of  
the unit.  
E-4  
E-5  
 
The programmable mode allows you to set the timer to turn the humidifier both on/off  
at a daily predetermined time. This mode also allows the clock to be programmed.  
1. Power Button  
Before turning on make sure there is water in the unit.  
Press the Power Button.  
FIRST TURN POWER BUTTON ON.  
Power  
Done  
set  
S tart  
S top  
Time  
r
2. Warm or Cool Mist Button  
Hour  
Select/Set  
Minute  
Press to select warm or cool mist. Water  
temperature is maintained at room temperature for cool  
setting and 80 degrees for warm.  
S p  
C
Program Start  
Cool/W arm  
1. Push Select/Set Button until "START" is blinking on display.  
2. While "START" is blinking, select the desired start time using Hour and  
Minute buttons (AM or PM as indicated).  
3. Spray Control Button  
3. Select Cool/Warm preference.  
4. Select Spray Control preference.  
When you press the Spray Control Button  
there are four options to choose from:  
Press once for WEAK  
Dim  
5. "START" indicator will remain lit once programmed.  
Press twice for MIDDLE  
Program Stop  
Press three times for STRONG  
Spray  
Control  
1. Push Select/Set Button until "STOP" is blinking on display.  
2. While "STOP" is blinking, select the desired end time using Hour and  
Minute buttons (AM or PM as indicated).  
Press four times for TURBO  
*You will notice the lights get higher as the spray increases.  
3. "STOP" indicator will remain lit once programmed.  
4. To cancel program, press and hold select/set button for two seconds  
(START and STOP buttons will not be lit).  
4A. Light Options - Display Button  
Press the Display Button to turn the display lights ON or OFF.  
Clock Set  
Display  
1. Clock must be set in order for timer to work properly.  
2. Push Select/Set Button until "TIME" is blinking on display.  
3. Select actual time using Hour and Minute Buttons (AM or PM as indicated).  
4B. Light Options - Night Light Feature  
Press the Lamp Button at the top of the unit to illuminate  
the night light feature.  
Lamp  
5. Water Refill Button  
When the Water Refill Button lights up it is time to refill  
the water tank.  
E-7  
E-6  
 
Always unplug the unit before servicing it in any way.  
PROBLEM  
SOLUTION  
The temperature of the water remaining in the unit after use may be HIGH.  
Do not submerse the unit in water, or allow water to enter anywhere on the unit  
except the designated water tank.  
Water vapor & humidity are  
not produced.  
Power Plug: Unplug and then try again.  
Power Failure: When the power is returned, try again.  
Tank Installation: Make sure the water tank is  
correctly attached. Make sure spring on tank  
cap moves freely when pushed.  
INSIDE THE BODY OF THE UNIT  
Pour excess water out of the unit, but do not allow it to enter the hole where the water  
vapor comes out. Wash out the unit with fresh water, using the cleaning brush and a  
soft cloth as needed.  
Air blows but water vapor is  
not produced.  
Excessive Water: Remove a certain amount of water  
from the tank.  
OUTER SURFACE OF THE UNIT  
Wipe the surface of the unit with a soft, damp cloth if needed.  
The desired humidity is lower than the current tem-  
perature: Increase the desired humidity.  
WATER TANK  
If water spots remain in the water tank, wipe the inside with a soft cloth.  
DO NOT use soap or detergents.  
Detergent residue in the tank: Wash the tank out and  
try again.  
AIR FILTER  
The surface of the ultrasonic metal disk may be dirty:  
Wipe it off with a dry, soft cloth. Clean with diluted  
vinegar.  
Gently wipe away debris from the filter with a soft cloth.  
This filter does NOT need to be replaced.  
Humidity level is low.  
The water in the unit is too cold: Replace with cool,  
but not cold water.  
ULTRASONIC DISK  
Remove spray spout (Fig. 1) and use the enclosed cleaning brush to regularly remove build up  
and deposits from this area (Fig. 2). Diluted vinegar will help to prevent this build up.  
Warm humidity is not produced.  
It may take 10-15 minutes before warm  
humidity is created. The mist may not feel  
warm to the touch.  
Check to see if base of unit feels warm to the touch.  
If so then warm mist is being produced.  
Fig. 2  
Fig. 1  
The humidity has a bad smell.  
Poor maintenance or dirty water: Clean the product  
thoroughly, and fill it with fresh water.  
White dust is forming on  
nearby furniture.  
Hard water will deposit a certain amount of  
dust. Dust in the air settles because of the  
added humidity in the room.  
Fully dry the inside and outside of the unit before storing it.  
DO NOT leave water in the unit.  
Store in a cool, dry place.  
*Use distilled water if this becomes a nuisance.  
E-9  
E-8  
 

Grizzly Drill H6362 User Manual
H2O Audio Carrying Case iFP 700 User Manual
HANNspree Flat Panel Television ST02 15A1 User Manual
Hasbro Games 08855 User Manual
Hearth and Home Technologies Stove CB1200 B User Manual
HP Hewlett Packard Network Card BL30p User Manual
HP Hewlett Packard Printer 1050C User Manual
Humax Flat Panel Television LGB 19DRT User Manual
IBM Laptop 600 600E 2645 User Manual
Ikelite Digital Camera 687145 User Manual