Greenheck Fan Ventilation Hood 468502 User Manual

Part number 468502  
Duct to Sleeve Connection  
INSTALLATION INSTRUCTION SUPPLEMENT  
Refer to:  
‘Installation Instructions for FD, DFD, SSFD, & KFD Series”  
(Part number 452763)  
“UL CLASSIFIED  
(see complete marking on product)”  
“UL CLASSIFIED to Canadian safety standards  
(see complete marking on product)”  
Standards UL 555 & 555S  
or  
“Installation Instructions for FSD-XXX, DFD-XXX, SSFSD-XXX &  
CFSD-XXX Series Fire & Combination Fire Smoke Dampers’  
(Part number 461336)  
or  
Classifications Filed at UL under Listing #R13317  
“Installation Instructions for FD & DFD 150X Series Curtain Fire  
Dampers’ (Part number 453946)  
or  
“Installation Instructions for OFSD, ODFD, OFD, AND OSSFD  
Series Dampers’ (Part number 461337)  
or  
‘Installation Instructions for FSD-3XXXV Series Dampers’  
(Part number 461666) for additional details  
These instructions describe an alternate breakaway connection between a fire damper or combination fire  
smoke damper sleeve and an adjoining piece of ductwork. This alternate connection is covered under the UL  
certification of the damper. These instructions apply to a connection between a manufactured flange system  
by Ductmate, Ward, or Nexus and a TDC or TDF flange system.  
1. Install the manufactured flange system onto the damper sleeve per the manufacturer’s instructions.  
2. To seal the two flange systems together Neoprene or Butyl gasket may be applied to the mating surfaces.  
3. Align the two flange systems together. An optional 3/8 in. (9mm) bolt may be used in the corners to help  
with the alignment. These bolts do not have to be removed.  
4. Install the metal cleat (see Figure 1) or #10 tek screw (see Figure 2), approximately equally spaced, per the  
schedule described below:  
• Width or height less than 24 in. (610mm); use one cleat or screw per side  
• Width or height 24 in. (610mm) to less than 36 in. (914mm); use 2 cleats or screws per side  
• Width or height 36 in. (914mm) to less than 54 in. (1372mm); use 3 cleats or screws per side  
• Width or height 54 in. (1372mm) to less than 72 in. (1829mm); use 4 cleats or screws per side  
• Width or height 72 in. (1829mm) or greater; use 5 cleats or screws per side.  
#10 x 3/4”  
TEK Screw  
Metal cleat  
Spot weld or Tek screw per  
manufacturer instructions  
Spot weld or Tek screw per  
manufacturer instructions  
TDC or TDF  
Connection  
TDC or TDF  
Connection  
Butyl Gasket  
Damper Sleeve  
Butyl Gasket  
Damper Sleeve  
Figure 1  
Figure 2  
Copyright © 2007 Greenheck Fan Corporation  
468502 Breakaway connection Rev. 3 December 2007  
 

Graco Blood Pressure Monitor 3A1331C User Manual
Hans Grohe Plumbing Product 06699XX0 User Manual
Harman Kardon Home Theater System HKTS20 User Manual
Harman Stove Company Stove P68 User Manual
Honeywell Barcode Reader 1200g User Manual
Honeywell DVR HRTL One User Manual
HP Hewlett Packard Personal Computer VS825UT User Manual
HP Hewlett Packard Projector 760c User Manual
Husqvarna Trimmer 322R User Manual
IBM Home Theater Server SB84 0449 00 User Manual