Greenheck Fan Stud Sensor 474750 User Manual

Part #474750  
®
Digital Temperature Interlock  
Installation, Operation and Maintenance Manual  
Please read and save these instructions for future reference. Read carefully before attempting to assemble,  
install, operateormaintaintheproductdescribed. Protectyourselfandothersbyobservingallsafetyinformation.  
Failure to comply with instructions could result in personal injury and/or property damage!  
General Description  
Description  
The temperature interlock is designed to automatically  
start kitchen hood exhaust fans and keep them  
running while heat is being generated from the  
cooking appliances. Hood systems should always be  
manually started before equipment is turned on. If  
the fans are forgotten to be turned on, the interlock  
will turn the fans on once heat is detected. The  
interlock consists of a temperature controller, resistive  
temperature detector (RTD), junction box, Evergreen  
Product Specification  
Compression Seal threaded fitting, and is contained  
in a stand alone box or can be added to a pre-  
engineered fan control center.  
Digital Temperature Interlock  
International Mechanical Code (IMC) 2006 section  
507.2.1.1 Compliant Electrical Package  
Provide Greenheck temperature interlock electrical  
package as shown on plans and in accordance with  
the following specification:  
Purpose  
To meet IMC 2006 section 507.2.1.1, interlock  
between exhaust fans and cooking equipment. This  
system will utilize a temperature sensor in the exhaust  
duct collar or in capture area of hood to detect heat  
generated from cooking operations and automatically  
activate the exhaust fans if not already turned on.  
Field wiring may be required depending on location of  
components.  
The temperature interlock(s) consists of a temperature  
controller, resistive temperature detector (RTD),  
junction box, fire proof/leak proof threaded fitting  
(Evergreen Quik-Seal® and/or Evergreen Compression  
Seal), and shall be a self-contained unit or as part of  
another pre-engineered electrical control package.  
Product Application  
The temperature interlock is designed to be used  
with Type I and Type II hoods. It is not to be used in  
conjunction with exhaust fire dampers. Greenheck  
recommends using one interlock per hood system  
(activates all fans linked to system simultaneously).  
The temperature interlock package shall close a  
relay powering the fans when the sensor detects the  
temperature set point. The interlock shall hold the  
circuit closed upon fan switch being turned off until  
the temperature sensor detects a temperature below  
the set point plus hysteresis. Once the temperature is  
below the set point plus hysteresis, the fans shall shut  
down.  
Performance Goals  
Automatically energize the exhaust fans when cooking  
equipment generates heat. Basic controls will be  
provided with a temperature sensor and will consist  
of an 8 x 8 electrical box with controls and a labeled  
terminal strip to hook-up incoming power and fan  
starters. A temperature controller is used to keep the  
exhaust fans running when the temperature controller  
initially closes to prevent the fan from cycling on and  
off at startup and shut down. Fans will shut down  
automatically once the temperature has gone below  
the set point plus hysteresis. The hysteresis can be  
adjusted based on jobsite requirements.  
The temperature interlock package shall be  
constructed by Greenheck in accordance with  
International Mechanical Code. The manufacturer  
shall provide, upon request, the necessary data that  
confirms compliance with the code listed above.  
Due to continuous research, Greenheck reserves the  
right to change specifications without notice.  
Digital Temperature Interlock  
1
®
 
5. Place the resistive  
temperature  
Installation  
detector through  
the compression  
seal and tighten  
the compression  
fitting.  
Control Box Mounting  
Locate an area with enough space to mount the  
control box and fasten to the wall.  
Resistive Temperature  
Detector (RTD)  
PN 384439  
NOTE  
Octagon Extension  
PN 830125  
6. Install the cover  
for the octagon  
box.  
Control box may be factory mounted. If so, continue  
to the next section.  
Octagon Cover  
PN 380926  
Resistive Temperature Detector(s)  
(RTD) Mounting  
Duct Collar Mounting  
1. Locate the exhaust duct on top of the hood. A 3/4  
to 7/8-inch (19.0 to 22.2 mm) diameter hole must  
be cut into the duct 2 inches (50.8 mm) above the  
hood top. Center  
NOTE  
Resistive temperature detector(s) may be factory  
installed. If so, continue to the next section.  
the hole along  
0.75 to 0.875 inch  
(19.0 to 22.2 mm)  
2 inches  
(50.8 mm)  
the side of the  
duct. Make sure  
that the resistive  
temperature  
diameter hole  
1. Locate flat area(s) at the top interior of the hood in  
front of the filters, towards the front of the hood.  
Hood Exhaust Collar  
Front Side  
detector will not  
interfere with any  
19.525 inches  
3 inch air space  
fire system nozzles, or other items installed in the  
exhaust duct. If an exhaust fire damper is present  
the hood exhaust collar, it must be removed prior  
to temperature sensor installation.  
2 inch typical  
Exhaust Area  
Sensor Install  
(cutout area)  
2. Place the J-box plate inside of the octagon  
extension ring and place over the hole in the  
exhaust collar.  
Supply Area  
(optional)  
P.O.BOX 410 SCHOFIELD  
3. Disassemble the compression seal and place  
TITLE  
1/4-inch Compression Seal  
PN 463570  
through  
INSTR, ADJ  
Top View of Exhaust Hood  
hole in duct  
collar and  
Octagon Extension  
PN 830125  
Quik Seal  
Gasket  
2. Cut a 3/4 to 7/8-inch diameter hole in the flat  
spot of the capture  
J-box plate  
as shown.  
J-Box Plate  
PN 732396  
tank. Make sure the  
0.75 to 0.875 inch  
(19.0 to 22.2 mm)  
diameter hole  
Tighten the  
resistive temperature  
detector(s) will not  
interfere with fire  
system nozzles and is  
not within 12 inches of  
light fixtures.  
Lock Washer  
nut inside  
the octagon  
extension  
ring.  
Nut  
Hood Surface  
4. Place the resistive temperature detector  
through the  
compression  
seal and  
tighten the  
compression  
3. Place the J-box plate inside of the octagon  
extension ring and place over the hole.  
4. Disassemble the compression seal and place  
through hole and J-box plate as shown. Tighten the  
nut inside the octagon extension ring.  
Octagon Cover  
PN 380926  
fitting.  
Compression Seal  
PN 463570  
5. Install the  
Resistive Thermostat  
Detector (RTD)  
PN 384439  
Octagon Extension  
PN 830125  
Gasket  
cover for the  
octagon box.  
J-Box Plate  
PN 732396  
NOTE  
Lock Washer  
Nut  
All field installation and wiring of electrical  
equipment must be done to meet NEC and local  
codes.  
Digital Temperature Interlock  
3
®
 
Electrical Connections  
Calibration  
Electrical Connections  
The temperature controller is preset by the factory  
to turn the fans on at 95°F. This is controlled by  
the set point on the temperature controller. The  
temperature set point may have to be adjusted slightly  
depending on both ambient and cooking conditions.  
The adjustment is made through the buttons on  
the temperature controller. To adjust, follow these  
instructions:  
1. Run two 18 awg thermostat wire from each  
temperature sensor to the appropriate electrical  
circuit connections. (See Step 3 for connection  
options).  
2. In junction box, connect leads on RTD to the  
18 awg conductors using appropriate size  
wire nuts.  
• Wires are interchangeable with one another.  
3. Choose the final connection based on:  
Terminals T3, T4, T5, T6, T7, T8 (if applicable) in  
fan control center (KFCC).  
1. Press the SET button to see the set point.  
2. Press the UP/DOWN arrow button to change the  
set point.  
Terminals 9, 10, 11, 12, 13, 14, 15, 16, 17, 18 (if  
applicable) in control box on top of hood/utility  
cabinet.  
3. Press the SET button to view the current  
temperature.  
4. Check system operation before making additional  
adjustments.  
CAUTION  
Do not connect temperature sensor in series  
with fan power. This will result in damage to the  
temperature sensor and will require replacement.  
Breaker Panel to Control Box or Fan Control  
Center  
1. Connect a Single Pole Single Throw (SPST) switch  
to one of the following based on application:  
Terminals 3 & 4 in the control box.  
Terminals S1 & S1H in the fan control center.  
Circuit Connections  
1. Standard Interlock Control  
120V, 10 or 15 amp circuit to terminals 1 & 2  
Control voltage for fan starter activation  
– 120V, 24V or other control circuit  
(drawing on page 5)  
Control circuit power to terminal 7  
Terminal 8 to fan starter coils  
Terminals 7 & 8 to fan starter coils  
2. Fan Control Center Integration (KFCC)  
Power to H1 & N1 in fan control center  
No additional control circuits are required fan  
starters are factory wired  
Digital Temperature Interlock  
4
®
 
Control Circuit Diagram (Standard Control)  
CONTROL INPUT: 120VAC, 15AMPS FROM BREAKER  
L1  
N
2
G
UNDER SUBJECT 891  
FILE #E200616  
UL LISTED  
LABEL DESCRIPTION  
FACTORY WIRING  
FIELD WIRING  
T1  
EF  
SF  
ST  
OL  
G
Exhaust Fan  
Supply Fan  
Starter  
1
ALL WIRING 90°C 14 GA.  
UNLESS SPECIFIED  
Overload  
Ground  
YW  
12 YW  
10  
5
6
C1  
WIRE COLOR  
S1  
FS  
Switch  
Fire Switch  
WT  
BK  
BK - black  
BL - blue  
4
2
5
1
STB Shunt Trip Breaker  
N
Neutral  
T1-T6 RTD Temperature Sensor  
FS Fire System Microswitch  
C1-C6 Controller, Dwyer 40-T  
BR - brown  
OR  
OR  
OR - orange  
PR - purple  
RD - red  
YW - yellow  
WT - white  
C
NO  
S1  
FIELD MOUNTED SWITCH  
FIELD WIRING TO SWITCH REQUIRED  
RD  
RD  
3
4
8
FIELD WIRING: use minimum 60° Copper Wire  
ST  
7
TYP. EXHAUST  
ST  
FIELD WIRE  
FIRE SYSTEM  
TYP. EXHAUST  
MICROSWITCH  
C
FS  
NO  
NC  
ST  
TYP. SUPPLY  
CONTROL INPUT: 24/120 VAC, 15AMPS FROM BREAKER  
WIRING FOR ADDITIONAL SENSORS (OPTIONAL)  
T2  
T3  
YW  
YW  
YW 10  
11  
YW 12  
10  
12  
10  
12  
9
C2  
C3  
WT  
BK  
WT  
BK  
4
2
5
1
4
2
5
1
1
2
1
2
OR  
OR  
OR  
OR  
C
NO  
C
NO  
S1  
T4  
S1  
T5  
3
4
3
4
YW  
YW 14  
15 YW  
YW 16  
10  
12  
10  
12  
13  
C4  
C5  
WT  
BK  
WT  
BK  
4
2
5
1
4
2
5
1
1
2
1
2
OR  
OR  
OR  
OR  
C
NO  
C
NO  
S1  
T6  
S1  
3
4
3
4
17 YW  
YW 18  
10  
12  
C6  
WT  
BK  
4
2
5
1
1
2
OR  
OR  
C
NO  
S1  
3
4
Digital Temperature Interlock  
5
®
 
Control Circuit Diagram (Fan Control Center)  
CONTROL INPUT: 120VAC, 15AMPS FROM BREAKER  
L1  
N
CONTROL PANEL  
Lights Switch  
Fan Switch  
T1  
H1  
N1  
G
Panel Mark:  
KFCC  
12 inches  
YW  
YW  
Hood Mark(s):  
Motor Fan Mark  
HD-1  
10  
12  
T1  
T2  
TC1  
FLA  
HP Volt PH  
Wire Breaker  
RD  
RD  
WH  
4
2
5
1
F1 EF-1  
F2 MAU-1  
1.5 460  
1.0 460  
3
3
3.0 14ga 15amp  
2.8 14ga 15amp  
OR  
OR  
C
NO  
S1  
18 inches  
LT1  
A2  
OR  
WH  
WH  
R
S1H  
S1  
S1N  
OL1  
OR  
ST 1  
96  
95  
A1  
#1 Qty. Fan Switches (0-3)  
#1 Qty. Light Switches (0-3)  
#0 Qty. Temp. Switches (0-1)  
Exhaust in Fire  
MUA Interface  
Lights Out in Fire  
Fire Relay (#1)  
Extra Fire Relay (#2)  
Extra Fire Relay (#3)  
DPDT Relay w/SF  
DPDT Relay w/EF  
Oꢁ Delay Relay  
SF Failure Light  
EF Failure Light  
Fan Failure Light (Appl.)  
Damper  
2
M
L
1
-9  
F
One Switch for L & F  
One Breaker Con. L & F  
Heat Switch  
I
H
T
6 inches  
Tempering SW  
C
Y
X
P
V
A
R
G
B
S
Cool Switch  
AD Switch  
Remote Switches  
Pushbutton Switches  
Evap Cooler Switch  
Audible ALarm  
Gas Reset  
Power for Gas Solenoid  
Power for Shunt Trip  
E
O
J
K
N
D
U
OL 1  
OL 2  
ST 1  
T1  
L1  
L2  
L3  
T1  
T2  
T3  
L1  
L2  
L3  
INPUT POWER  
3 WIRE  
3 PHASE  
Q
Gas Oꢁ w/Fans  
EXH  
FAN  
G
G
T2  
T3  
Aux. Supply Contact  
Tie in WWCP  
1
2
W
FROM BREAKER  
ST 2  
Spare Fire Switch Contact  
(dry contacts for building alarm)  
L1  
L2  
L3  
T1  
T2  
T3  
T1  
T2  
T3  
L1  
L2  
L3  
INPUT POWER  
3 WIRE  
3 PHASE  
SUP  
FAN  
Ansul(Amerex)  
RD(RD)  
BR(BK)  
RD(RD)  
C2  
FROM BREAKER  
BR(BK)  
NC2  
NC  
NO  
FS2  
C
BK(YW)  
BK(YW)  
NO2  
Spare Relay Contacts  
(can be used for shunt trip, alarms, etc.)  
(activated by FS1)  
OR  
R1  
1
R1  
1
RD  
RD  
BR  
BK  
C3  
RD  
YW  
3
C4  
4
BR  
BK  
A
B
NO3  
NC3  
NO4  
NC4  
A
B
4
3
5
6
R2  
R2  
OL2  
96 95  
1
8
YW  
WH  
ST 2  
A1  
A2  
open w/power at H1/N1 & ꢀre sys. armed  
closed on ꢀre or no power  
A
closed w/power at H1/N1 & ꢀre sys. armed  
open on ꢀre or no power  
B
TORQUE:  
FIELD WIRING:  
TERMINAL STRIPS = 18 IN/LB.  
GROUNDING BAR = 20 IN/LB.  
use minimum  
60° Copper Wire  
D3  
D1  
D2  
LABEL DESCRIPTION  
FACTORY WIRING  
HOOD WIRING  
FIELD WIRING  
EF  
SF  
ST  
OL  
C
Exhaust Fan  
Supply Fan  
Starter  
ALL WIRING 90°C 14 GA.  
UNLESS SPECIFIED  
OverLoad  
Contactor  
Ground  
G
WIRE COLOR  
S
Switch  
BK - black  
BL - blue  
LT  
FS  
R
Light  
Fire Switch  
Relay  
FS1  
BR - brown  
OR - orange  
PR - purple  
RD - red  
RD  
RD(RD)  
BR(BK)  
BR  
WH  
C1  
NC1  
NO1  
R1  
AF  
SV  
Air Flow Switch  
Gas Solenoid  
NC  
NO  
2
7
C
R2  
2
7
STB Shunt Trip Breaker  
BK(YW)  
YW - yellow  
WT - white  
D
Damper  
Push Button  
PB  
EC  
TC  
Evap Cooler  
Temperature Controller  
NOTES:  
Drawing shown de-energized at L1 (term.#H1),  
with ꢀre system armed (non-ꢀre mode).  
(in normal operation, R1 & R2 are energized)  
If wall mounted prewire, or ꢀeld installed ꢀre  
system, the ꢀre system microswitches must  
be ꢀeld wired.  
UNDER SUBJECT 891  
FILE #E200616  
UL LISTED  
Wiring Diagram #  
KFCC-TEMP-INTERLOCK  
Digital Temperature Interlock  
6
®
 
Testing  
Troubleshooting  
1. Turn fan switch on, then off to ensure proper fan  
operation before cooking equipment is started.  
Once this is verified, testing can proceed.  
Fans do not turn on automatically upon cooking  
equipment activation.  
• Check wiring to control panel or relay box  
• Multiple sensors must be wired separately  
Temperature set point too high, decrease set  
2. Heat up cooking equipment with fans off. Once  
the duct temperature reaches the set point of the  
temperature controller the fans will start within  
5 minutes. If the fans take more than 5 minutes  
to start, decrease the temperature set point  
by adjusting the set point on the temperature  
controller (see Calibration).  
point  
• No power to fans, check breakers/starters/relays  
Fans do not shut off.  
• Switch must be in the off position  
• Cooking equipment hot, wait for it to cool  
Temperature set point too low, increase set point  
3. If an adjustment was made in Step 2, repeat now.  
4. After verification of fan start-up, shut down  
cooking equipment. The fan switch should still be  
in the off position. Once cooking equipment has  
cooled below the set point plus hysteresis, the  
fans will shut down.  
• Ensure wires connected to appropriate control  
circuit  
Fans cycle off to on when turned off.  
• Cooking equipment not cooled enough, retry in  
5 minutes  
Fans do not turn on quick enough.  
• Decrease temperature set point  
NOTE  
During testing, if fans do not start automatically in  
the first 10 minutes of cooking equipment activation,  
manually start fans to avoid accidental fire system  
dump due to heat build-up.  
Maintenance  
Daily  
Clean the temperature sensor with cloth and  
degreaser. Keep clean for best performance.  
Operation  
Weekly  
1. Turn fans on and off using the fan switch. It is  
normal for the fans to remain running after the  
switch is turned off. The exhaust duct temperature  
controller will open after heat is no longer present  
under the hood and the temperature is below the  
set point plus hysteresis, the fans shall shut down.  
Dependant on grease production and grease filter  
type, clean temperature sensor.  
Seasonal  
May have to change temperature setting on the  
temperature controller if ambient kitchen temperatures  
fluctuate between summer and winter seasons.  
2. In the event that the cooking equipment is started  
without turning the fans on manually, the fans will  
turn on automatically and remain running with  
the presence of heat under the hood. Once the  
temperature is below the set point plus hysteresis,  
the fans shall shut down.  
Whom to call  
Contact your local Greenheck representative.  
What to have ready for the call  
Sales order, serial number and description of product.  
Sales Order Number _______________________  
Serial Number _____________________________  
Digital Temperature Interlock  
7
®
 
Frequently Asked Questions  
Replacement Parts  
What temperature is the temperature controller set  
to from the factory?  
Part  
Quantity  
Description  
Number  
95º Fahrenheit.  
Temperature Sensor (RTD)  
MAMAC TE-700-0-1-A  
Will the temperature interlock automatically start/  
stop the fans?  
1
1
1
1
3
2
1
384439  
384440  
830125  
380926  
382859  
382858  
463570  
Temperature Controller  
Dwyer 40T-10  
When connected properly to fan starters the  
temperature interlock will automatically control  
the fans without input from the user. However, the  
intended use of the temperature interlock is as back-  
up to manual control.  
Ext, Octagon (drilled)  
SC55151-1/2 (380928)  
Cover, Octagon Box  
SC#54-C-1RACO 722  
May I connect the power going to my fan directly  
through the control box?  
Terminal Block, 3 pole,  
DIN-RAIL MT, BUS NDN3-WH  
No, the control box should only use control voltage  
only (24-120V), and a separate 120V power source  
is required to run the temperature interlock controls.  
Greenheck recommends the use of starters sized for  
each fan.  
Jumper, DIN-RAIL Terminal  
Block #JNDN3  
Evergreen Compression Seal,  
1/4-inch, #302  
Can I use one control box for multiple hood systems?  
This can be done, however, it is not recommended.  
Any one of the temperature controllers would turn on  
all hoods running on that control box. It is better to  
have one hood/fan per control box, plus a significant  
energy savings can be obtained if one or more of the  
hoods is not in operation.  
Codes and Standards Compliance  
UL 710  
• National Fire Protection Association (NFPA 96)  
• International Mechanical Code (IMC) 2006  
Section 507.2.1.1  
Can I still turn my fan on and off?  
Yes, the temperature interlock is designed to be  
operated with a typical on/off switch. The fan may  
not turn off directly after turning the fan switch off, it  
will sense when the cooking operations have cooled  
and then turn off.  
Warranty  
Greenheck warrants this equipment to be free from defects in material and workmanship for a period of one year from  
the shipment date. Any units or parts which prove defective during the warranty period will be replaced at our option  
when returned to our factory, transportation prepaid. Motors are warranted by the motor manufacturer for a period of  
one year. Should motors furnished by Greenheck prove defective during this period, they should be returned to the  
nearest authorized motor service station. Greenheck will not be responsible for any removal or installation costs.  
As a result of our commitment to continuous improvement, Greenheck reserves the right to change specifications  
without notice.  
AMCA Publication 410-96, Safety Practices for Users and Installers of Industrial and Commercial Fans, provides additional  
®
Phone: (715) 359-6171 • Fax: (715) 355-2399 • E-mail: [email protected]Web site: www.greenheck.com  
474750 • Digital Temperature Interlock, Rev. 2, May 2012  
Copyright 2012 © Greenheck Fan Corporation  
8
 

Haier Flat Panel Television L15D2 A0 User Manual
Heat Glo LifeStyle Indoor Fireplace PIER 40 User Manual
Heat Glo LifeStyle Indoor Fireplace XLR N CE User Manual
Honeywell Car Video System HMLCD15 User Manual
Hotpoint Dishwasher LTB 4B019 User Manual
Hotpoint Washer Dryer AQGL129PI User Manual
Hotpoint Washer HY6F3551 User Manual
HP Hewlett Packard Computer Drive Q153090901 User Manual
Hsu Research Speaker VTF 2 User Manual
IBM Computer Monitor 21L4364 User Manual