GE Monogram Refrigerator ZISS480NXSS User Manual

ZISS480NXSS  
GE Monogram® 48" Built-In Stainless Steel Side-by-Side Refrigerator  
with Automatic Icemaker and Water Filter  
The Installation Space  
Dimensions and Installation Information (in inches)  
47"  
35-1/2" for 36" models  
41-1/2" for 42" models  
47-1/2" for 48" models  
36" Models 12"  
42" Models 18"  
48" Models 20"  
* Shipping height.  
The refrigerator  
Case Width  
25-3/4"  
can be adjusted to  
fit into a cutout that  
is 83-1/2" min. to  
84-1/2” max. height.  
Note that the top  
case trim at the  
*Finished Width  
*84" From  
Floor to  
Top Frame  
*83-1/2"  
at  
Rear  
6"  
Electrical  
Area  
84-1/2" max  
83-1/2" min  
Finished  
front is 1/2" higher  
and will overlap  
upper cabinetry or  
soffit. Use leveling  
legs and wheels  
for a maximum 1"  
height adjustment.  
5"  
75" From Floor  
to Bottom  
of Electrical  
Area  
Opening  
24"  
48"  
27-3/4"  
Frame to Frame  
including  
handle  
5"  
5"  
Water Supply  
3-1/2"  
Product Clearances  
3-1/2"  
Water and electrical locations  
The opening must be prepared with the electrical and water  
supply located as shown.  
These refrigerators are equipped with a 2 position door stop.  
The factory set 130° door swing can be adjusted to 90° if  
clearance to adjacent cabinets or walls is restricted.  
130° Door Swing  
90° Door Swing  
The cutout depth must be 24".  
15"  
20"  
The refrigerator will project forward, slightly beyond  
adjacent cabinetry, depending on your installation.  
23-7/8"  
Behind  
Frame  
The cutout depth beneath a soffit:  
When installed beneath a soffit, the soffit cannot exceed the  
24" installation depth shown. The top case trim overlaps the  
bottom of the soffit.  
28-5/8"  
Frameless cabinets:  
The case trim overlaps cabinets at the top and sides.  
Therefore, frameless cabinets may require filler strips to  
prevent interference with cabinet door swing. The opening  
must allow for filler strips.  
4" Min.  
to Wall  
Allow minimum clearances for freezer door and fresh food  
door for a full 130° door swing and to allow for pan removal.  
4" minimum clearance is required when door swing is  
adjusted to 90°. If the 90° door stop position is used, pan  
access is maintained, but pan removal is restricted.  
Additional Specifications  
• A 115 volt 60Hz., 15 or 20 amp power supply is required.  
An individual properly grounded branch circuit or circuit  
breaker is recommended. Install a properly grounded 3-  
prong electrical receptacle recessed into the back wall.  
Electrical must be located on rear wall as shown.  
Installation Information: Before installing, consult  
installation instructions packed with product, or online  
at Monogram.com, for current dimensional data.  
Note: GFI (ground fault interrupter) is not recommended.  
• Water line can enter the opening through the floor or back  
wall. The water line should be 1/4" O.D. copper tubing or  
GE SmartConnectkit between the cold water line and  
water connection location, long enough to extend to the  
front of the refrigerator. Installation of an easily accessible  
shut off valve in the water line is recommended.  
For answers to your Monogram,® GE Profileor  
GE® appliance questions, visit our website at  
ge.com or call GE Answer Center® service,  
800.626.2000.  
Listed by  
Underwriters  
Laboratories  
Specification Revised 11/08  
110192  
 

Echo Chipper CH45342 77412 User Manual
ELAN Home Systems Satellite Radio DT22 User Manual
Fisher Price Baby Toy C6508 User Manual
Frigidaire Cooktop FGGF3041K F User Manual
Frigidaire Microwave Oven FGMV174K User Manual
Fujitsu Switch FS 102AT User Manual
Fusion Radio Antenna 21 User Manual
Gardena Outdoor Timer T14 User Manual
GE Cooktop GLD6500LWW CC BB User Manual
Generac Portable Generator 1019 3 User Manual