ZICS360NX
GE Monogram® 36” Built-In Bottom Freezer Refrigerator
Dimensions and Installation Information (in inches)
The Installation Space
Door Swing Clearances
The installation must allow for clearances to adjacent walls or
cabinets. These refrigerators are equipped with a 2-position
door stop. The factory-set 130° door swing can be adjusted to
90° if clearance to adjacent cabinets or walls is restricted.
The finished cutout width must be 35-1/2".
35-1/2"
Finished Width
Wall View
2-5/16"
25"
6"
Min. to
23-7/8"
Behind
Frame
Wall
10"
Electrical
90° Door Swing
130° Door Swing
Area
75" From
Floor to Bottom
of Electrical
Area
84-1/2" max
83-1/2" min
Finished
24" Cutout Depth
Cold Water
Opening
5"
5"
Supply
Note: Icemaker
water connectio
is at the front.
36-3/4"
3 1/2"
3 1/2"
90°
130°
The cutout depth must be 24"
The refrigerator will project forward, slightly beyond adjacent
cabinetry, depending on your installation.
4" Min. to Wall
5" Min. for Professional Models
The cutout depth beneath a soffit:When installed beneath
a soffit, the soffit cannot exceed the 24" installation depth
shown. The top case trim overlaps the bottom of the soffit.
Allow 25" minimum clearances for a full 130° door swing. Allow
15" for pan removal.
• 4" minimum clearance is required when the door swing is
adjusted to 90°. If the 90° door stop position is used, pan
access is maintained, but pan removal is restricted.
Electrical: A 115V, 60Hz., 15 or 20 amp power supply is
required. An individual properly grounded branch circuit or
circuit breaker is recommended. Install a properly grounded
3-prong electrical receptacle recessed into the back wall.
Electrical must be located on rear wall as shown.
• See door swing illustrations to determine interaction with
adjacent cabinets or countertops.
ZUG2, ZUGSS2 Unified Grille Panel Kit
Note: GFI (ground fault interrupter) is not recommended.
• If you are installing two refrigerators side by side, the
installation space must be 71-1/2" wide.
Water Line: All models are equipped with an automatic
icemaker. The water line can enter the opening through the
floor or back wall. Route GE SmartConnect™ Kit or 1/4" O.D.
copper tubing between the cold water line and the water
connection location at the front of the refrigerator. The
installation of an easily accessible shut-off valve in the water
Note: Additional cutout width may be required when side panels
are used. Add side panel thickness to the finished cutout to
calculate rough-in width.
• The water and electrical locations for each product must be
located as shown.
line is required.
• A separate 115V, 60Hz., 15 or 20 amp power supply is
recommended for each product.
*Shipping Height. The
refrigerator can be adjusted
Product Dimensions
35"
Case Width
Case Depth:
25-3/8" Framed Models
25-3/4" Stainless Steel Models
to fit into a cutout that is
83-1/2" min. to 84-1/2" max.
height.
The top case trim at the front
is 1/2" higher and will overlap
upper cabinetry or soffit.
Use leveling legs and wheels
for a maximum 1" height
adjustment.
71-1/2" Finished Width
2-5/16"
Wall View
Electrical
24-3/16"
6"
*84" From
Floor to
Top Frame
*83-1/2"
at
Rear
10"
10"
84-1/2" max
83-1/2" min
Finished
24" Cutout
Depth
75" From
Floor to Bottom
of Electrical
Area
36"
Frame to Frame Width
Opening
Depth Including Handles:
5"
5"
Water Supply
26"
Water Supply
26"
26-7/8" Framed Models
27-3/4" Stainless Steel Models
28-11/16" Professional Models
For answers to your Monogram,® GE Profile™ or
GE® appliance questions, visit our website at
ge.com or call GE Answer Center® service,
800.626.2000.
3-1/2"
3-1/2"
Listed by
Underwriters
Laboratories
Specification Created 6/08
110114
|