GE Appliances
AZ38H09D – GE Zoneline® Deluxe Series Heat Pump Unit
Wall Case Dimensions
Maximum Cord Extension (in inches)
Electrical Wiring
All wiring, including installation of receptacle, must be made in
accordance with local electrical codes and regulations.
A
Note: Aluminum wiring may pose special problems – consult
a qualified electrician.
Grille Options
Stamped Aluminum Grille – RAG60
Exterior Architectural Louvers Durable Polycarbonate:
C
RAG61 or RAG64 (Beige)
RAG63 or RAG66 (Bittersweet)
21
58
RAG62 or RAG65 (Maple) RAG67 (Extruded Aluminum)
Retrofit Kits:
B
RAK901L – Wall Case Insulation for use with heat pumps.
RAK40 – Deflector Kit to adapt chassis for use with existing
exterior architectural louvered grilles.
RAB71 Wall Sleeve
Wall Opening Dimensions
Heavy-gauge galvanized steel, with insulation.
A – 42", B – 13-3/4", C – 16"
Add 1/4" to A and C dimensions for all cut-out size.
RAB71 16-1/4" Min. H x 42-1/4" Min. W
Ducted Applications
2800 and 3800 series can be used with ductwork to heat or
cool more than one room. RAK6052 Duct Adaptor is applied
to top of case over air discharge/RAK601 Duct Extension is
applied to right or left of adaptor. Locally fabricated ductwork
may be added to extend to maximum recommended distance
of 15 feet.
RAB71 available in 16", 24", 28" and 31" depths
RAB77 16-1/2" Min. H x 42-3/8" Min. W
RAB77 Wall Sleeve
Molded SMC fiberglass-reinforced polyester compound.
A – 42-1/8", B– 13-7/8", C – 16-1/4
230/208 Volt Line Cord Connected Units
Min. Circuit
Protection
(Amps)
Line Cord
Kit
Electric Heat
(Btuh)
Electric
Heater Watts Heat Amps
2,550/2,090
3,450/2,820
5,000/4,090
Electric
Electrical Connection
230/208 volt units may be plugged into a receptacle. 265 volt
units are provided with a junction box and require direct
connection. (NEC Requires 265V Direct Connection) See
Architects and Engineers Design Data Manual for electrical
connection information including use of sub-base for direct
connected units. Installation must comply with local electrical
codes and regulations.
RAK3153
8,600/7,100
11,700/9,600
17,000/13,900
11.6/10.6
15.5/14.1
22.3/20.3
15
20
30
RAK3203
RAK3303
230/208 Volt Sub-Base Connected Units
Min. Circuit
Protection
(Amps)
Electric Heat
(Btuh)
Electric
Heater Watts Heat Amps
Electric
Power Connection kits required on all Zoneline chassis.
Sub-Base
RAK204D15P
RAK204D20P
RAK204D30P
8,600/7,100
11,700/9,600
17,000/13,900
2,550/2,090
3,450/2,820
5,000/4,090
11.6/10.6
15.5/14.1
22.3/20.3
15
20
30
For answers to your Monogram,® GE Profile™ or
GE® appliance questions, visit our website at
ge.com or call GE Answer Center® service,
800.626.2000.
Specification Revised 3/06
390519
|