Dehumidifier
D25D, D50D, D70D
Models
D25D Volts: 115/60Hz Capacity: 25 Pints Moisture Removal: 25 Pint/Day
D50D Volts: 115/60Hz Capacity: 50 Pints Moisture Removal: 50 Pint/Day
D70D
Volts: 115/60Hz Capacity: 70 Pints Moisture Removal: 70 Pint/Day
920-198-10 (3-10)
920-198-10
DESCRIPTIONOFCOMPONENTS
DEHUMIDIFIED
DRY AIR VENT
Figure 1
CONTROL PANEL
AIR FILTER
HANDLE
MOIST AIR
INTAKE
DRAIN PUMP OUTLET
(ONLY ON 50 AND 70 PINT MODELS)
CONTINUOUS
DRAINAGE OUTLET
DRAIN BUCKET
ROLL CASTERS
FRD001
FUNCTIONEXPLANATION
Figure 2
BUCKET FULL LAMP DEFROST LAMP
CURRENT TEMP / TIMER SET DISPLAY
LAMP LIGHTS WHEN LAMP LIGHTS WHEN UNIT IS
WHEN THE UNIT IS RUNNING THE CURRENT TEMP IS DISPLAYED.
WHEN THE TIMER BUTTON IS PRESSED THIS WINDOW DISPLAYS
THE TIMER SETTING THEN REVERTS BACK TO THE TEMPERATURE
AFTER 10 SECONDS.
DRAIN BUCKET IS
FULL AND NEEDS TO
BE EMPTIED.
DEFROSTING (SEE PAGE 5).
°C/°F SELECTOR
PRESS THE °C/°F
SWITCH BUTTONS
IT WILL SWITCH
TIMERS
CURRENT HUMIDITY DISPLAY
FAN SPEED
HIGH/LOW
WHEN THE UNIT IS ON PRESS THE DISPLAYS THE CURRENT
TIMER BUTTON TO DISPLAY THE
POWER OFF TIMER.
RELATIVE HUMIDITY (RH) IN
THE ROOM. WHEN THE
IS PRESSED THE HUMIDITY
SETTING IS DISPLAYED.
OR
POWER
ON/OFF
BETWEEN °C AND °F.
SELECT FROM 1-24 HOURS OF
RUNNING TIME UNTIL THE UNIT
SHUTS OFF AUTOMATICALLY.
WHEN THE UNIT IS OFF PRESS THE
TIMER BUTTON TO DISPLAY THE
POWER ON TIMER. SELECT FROM
1-24 HOURS UNTIL THE UNIT WILL
TURN ON AUTOMATICALLY.
SET HUMIDITY
ADJUST THE HUMIDITY % FROM
30% TO 90% RH BY PRESSING THE
BUTTONS. HUMIDITY IS
ADJUSTED IN 5% INCREMENTS.
OR
FRD002
3
920-198-10
OPERATIONINSTRUCTIONS
INSTALLATIONINSTRUCTIONS
Follow the steps below for unpacking and set up your unit.
WARNING
STEP 1.
STEP 2.
STEP 3.
Remove unit from carton and inspect.
Remove accessories from drain bucket.
Electrical Hazards
Install Roll Casters (D25D models only) per installation
instructions below.
STEP 4.
Set up unit in position with adequate clearance. Installation
of unit is complete.
Do not fold power cord as shown at left.
Roll Caster Installation (D25D Models only)
STEP 1.
STEP 2.
STEP 3.
Locate Roll Casters removed during STEP 2 above.
Lay unit on its side for ease of installation.
Insert Roll Casters in slots as shown (See Figure 3) until they
click into place.
Make sure the plug is placed fully and
firmly into the receptacle.
Figure 3
ROLL CASTER
Do not use multiple sockets as shown at
left.
Make sure the plug is clean.
FRD031
Set the unit upright. Roll Caster installation is complete.
Allow unit to sit upright 1 hour before operating.
STEP 4.
STEP 5.
After turning the unit off please take plug
out of the receptacle.
Allow 8 inches of space on all sides of the unit.
Figure 4
Do not have wet hands when connecting
the power plug.
8’’
Do not pull the power cord to avoid a
broken cord, which can lead to danger.
8’’
8’’
8’’
FRD032
4
920-198-10
Start Operation
When Bucket Full Lamp Is On
STEP 1.
Place the unit in an upright position on a flat, steady, stable and
When the drain bucket is full, the Bucket Full lamp will illuminate and the
unit will stop operating. The drain bucket should be carefully removed from
the unit by sliding it outwards (See Figure 6) and should be emptied. Then
place the empty drain bucket back to its proper position, (See Figure 7)
the unit will start operating and run normally.
heat resistant surface. Make sure there is nothing flammable
or heat sensitive within 39 inches. Operating the product in
any other position could cause a hazard.
Figure 6
WARNING
Electrical Shock Hazard
Make sure your electrical receptacle has the
same configuration as your dehumidifier’s
plug. If different, consult a Licensed Electrician.
Do not use plug adapters.
Do not use an extension cord.
Do not remove ground prong.
Always plug into a grounded 3 prong oulet.
Failure to follow these instructions can result in
death, fire, or electrical shock.
PLEASE USE BOTH HANDS
TO CAREFULLY EMPTY THE
DRAIN BUCKET.
FRD005
STEP 2.
STEP 3.
Insert the plug into a suitable wall
socket. The dehumidifier is suitable
for operation on an electricity supply
having the same voltage as that
shown on its rating label.
Defrost
When the unit is operated in low temperatures (less than 54 °F
the surface of the evaporator will accumulate a layer of frost which will
reduce the efficiency of the dehumidifier. When this happens the unit will go
into periodic defrost mode automatically. The Defrost Lamp will illuminate
on control panel, this is quite normal (See Figure 7).
Make sure the Drain Bucket is correctly placed in the proper
position (See Figure 5). (After switching the unit 'ON" for the
first time, if the Bucket Full lamp illuminates, just pull out
the drain bucket; check to ensure that the float lever is able
to move freely, then return the drain bucket to the correct
position).
The dehumidifier will operate in temperatures down to 41 °F. The time it
takes to defrost may vary. If the unit freezes up it should be turned off at the
power supply for a few hours and then re-started. If the room temperature
remains below 41 °F the unit should be switched off. It is not recommended
to use the dehumidifier in temperatures below 41 °F.
Figure 5
Figure 7
DEFROST LAMP
BUCKET FULL LAMP
DRAIN BUCKET
DRAIN BUCKET
FRD004
FRD006
5
920-198-10
Do not use insect, oil or paint spray around the unit (See Figure 11), it might
cause damage to the plastic parts or start a fire.
OPERATINGDO'SANDDON'TS
Do not place anything on top of the unit or control panel (See Figure 8).
Figure 11
Figure 8
FRD014
Do not place the unit on an uneven surface (See Figure 12), to avoid
shaking, noise and leakage of water.
FRD007
Figure 12
Do not place anything over the inlet or outlet points (See Figure 9).
Figure 9
FRD015
Do always keep the unit 8 in. away from the wall (See Figure 13) to dissipate
the heat properly.
Figure 13
FRD008
Do not wet the unit or the control panel (See Figure 10).
8.00 IN.
Figure 10
FRD010
FRD016
6
920-198-10
Do not put any foreign objects into the unit, it is dangerous and will result
in damage to the unit (See Figure 14).
When moving or putting unit in storage, do not place the unit on its side or
upside down and avoid violent shaking (See Figure 16).
Figure 16
Figure 14
FRD020
Do ask professional service technicians to service the unit as required
(See Figure 17).
Figure 17
FRD017
Do close all open windows to reach the maximum possible efficiency of
dehumidifier removing moisture (See Figure 15).
Figure 15
FRD012
FRD018
7
920-198-10
Insert the drain hose through the hole of the drain cover. Then connect the
drain hose to the drain port (See Figure 20).
CONTINUOUSDRAINAGE
To save having to periodically empty the drain bucket, this unit can be
configured for continuous drainage. You can use the supplied drain hose
to connect to the continuous drainage connector (See Figure 18).
Figure 20
BACK OF UNIT
Figure 18
BACK OF UNIT
DRAIN HOSE
DRAIN HOSE
DRAIN COVER
FRD023
DRAIN COVER
Tighten the drain cover in clockwise direction onto the rear of the unit
(See Figure 21).
FRD021
Unscrew and remove the drain cover at the rear of the unit (See Figure 19).
Figure 21
Remove the soft rubber stopper. Put it into the drain bucket for safe keeping
(See Figure 19).
BACK OF UNIT
Figure 19
BACK OF UNIT
DRAIN COVER
DRAIN HOSE
SOFT RUBBER STOPPER
DRAIN COVER
FRD024
Place the bucket in its original location (See Figure 22).
Figure 22
FRD022
PUSH THE DRAIN BUCKET
BACK INTO THE UNIT IN THE
DIRECTION THE ARROW IS
POINTING.
DRAIN
BUCKET
DRAIN HOSE
FRD025
8
920-198-10
Drain Hose Routings
Continuous Draining using the Pump
(D50D/D70D models only)
Installation:
When using the function of continuous drainage, the drain hose must be
placed horizontally below the drainage hole (See Figure 23).
You must avoid uneven ground and folding the hose (See Figure 23).
STEP 1.
STEP 2.
STEP 3.
Connect the attached continuous drainage adaptor (1) to the
drain hole on the rear panel (2).
Figure 23
Connect the supplied water hose to the plug that fits into the
drain hole.
Lead the other end to a suitable location for drainage, like a
drain or sink and insert the plug into the water drain.
The maximum distance and the rise may be 15 ft from the unit. Exceeding
this distance may damage the unit or cause leaks. When the unit’s drain
bucket capacity reaches a certain water level, it will drain automatically
(See Figure 24).
Dismantle:
Press the drain hole (3) on the unit rear panel. The automatic drainage
adaptor will pull out (See Figure 24).
Figure 24
3
1
2
SUPPLIED
WATER
HOSE
PLUG
FRD027
NOTICE
In the automatic mode, the condensed moisture
is always removed through the air exhaust hose.
Removing the rubber plug from the water drain
will allow the water to drain out at this point. The
water drain can not be used.
FRD026
9
920-198-10
Cleaning Steps
MAINTENANCE
STEP 1.
Pull the air filter out gently (See Figure 25).
WARNING
Figure 25
Electrical Shock Hazard
AIR FILTER
Make sure your electrical receptacle has the
same configuration as your dehumidifier’s
plug. If different, consult a Licensed Electrician.
Do not use plug adapters.
Do not use an extension cord.
Do not remove ground prong.
Always plug into a grounded 3 prong oulet.
Failure to follow these instructions can result in
death, fire, or electrical shock.
For safety reasons, make sure the unit is
unplugged before servicing or cleaning.
FRD029
STEP 2.
Clean the air filter with a vacuum cleaner or wash it with clean
water and dry with a dry cloth (See Figure 26).
Cleaning the shell
Figure 26
STEP 1.
STEP 2.
Wipe the shell with a clean, soft cloth.
If the unit is very dirty, use mild detergent then wipe off the
detergent with half dried cloth.
WARNING
Water Hazard
Do not wash the unit with a hose
or immerse it in water. This may
cause leakage of electricity or a
shock hazard.
FRD030
Cleaning the air filter
STEP 3.
Put the clean air filter back in place and continue to operate
the dehumidifier.
The purpose of the air filter is to filter dust and other materials from the
air. If the filter is blocked by dust the electricity usage will be greater than
normal. For optimal moisture removal and efficiency, clean the filter every
two weeks.
10
920-198-10
INCASEOFEMERGENCY
If a problem occurs, unplug the unit and contact a qualified servicing center
immediately. Do not disassemble the unit yourself.
NOTICE
If the power cord on this unit is damaged it must
be replaced by the manufacturer, its service agent
or qualified service technician in order to avoid a
hazard.
NOTICE
This appliance is not intended for use by childern
or other persons without assistance or supervision
if their physical, sensory or mental capabilities
prevent them from using it safely. Children should
be supervised to ensure that they do not play with
the appliance.
11
920-198-10
Friedrich Air Conditioning Company
P.O. Box 1540
San Antonio, TX 78295
210.357.4400
DEHUMIDIFIERS
LIMITED WARRANTY
FIRSTYEAR
ANY PART: If any part supplied by FRIEDRICH fails because of a defect in workmanship or material within twelve months from
date of original purchase, FRIEDRICH will repair the product at no charge, provided the product is transported to a Friedrich
Authorized Service Center for repair. ALL transportation charges are the sole responsibility of the owner. This remedy is expressly
agreed to be the exclusive remedy within twelve months from the date of the original purchase.
SECOND THROUGH FIFTH YEAR
SEALED REFRIGERANT SYSTEM: If the Sealed Refrigeration System (defined for this purpose as the compressor, condenser
coil, dehumidifying coil, capillary, filter drier, and all interconnecting tubing) supplied by FRIEDRICH in your dehumidifier fails
because of a defect in workmanship or material within sixty months from date of purchase, FRIEDRICH will pay a labor allowance
and parts necessary to repair the Sealed Refrigeration System; PROVIDED FRIEDRICH will not pay the cost of diagnosis of the
problem, removal, freight charges, and transportation of the dehumidifier to and from the Service Agency, and the reinstallation
charges associated with repair of the Sealed Refrigeration System. All such cost will be the sole responsibility of the owner. This
remedy is expressly agreed to be the exclusive remedy within sixty months from the date of the original purchase.
APPLICABILITY AND LIMITATIONS: This warranty is applicable only to units retained within the Fifty States of the U.S.A.,
District of Columbia, and Canada. This warranty is not applicable to:
1. Air filters or fuses.
2. Products on which the model and serial numbers have been removed.
3. Products which have defects or damage which results from improper installation, wiring, electrical current
characteristics, or maintenance; or caused by accident, misuse or abuse, fire, flood, alterations and/or misapplication
of the product and/or units installed in a corrosive atmosphere, default or delay in performance caused by war,
government restrictions or restraints, strikes, material shortages beyond the control of FRIEDRICH, or acts of God.
OBTAINING WARRANTY PERFORMANCE: Service will be provided by the FRIEDRICH Authorized Dealer or Service
Organization in your area. They are listed in the Yellow Pages. If assistance is required in obtaining warranty performance, write
to: Room Air Conditioner Service Manager, Friedrich Air Conditioning Co., P.O. Box 1540, San Antonio, TX 78295-1540.
LIMITATIONS: THIS WARRANTY IS GIVEN IN LIEU OF ALL OTHER WARRANTIES. Anything in the warranty
notwithstanding, ANY IMPLIED WARRANTIES OF FITNESS FOR PARTICULAR PURPOSE AND/OR MERCHANTABILITY
SHALL BE LIMITED TO THE DURATION OF THIS EXPRESS WARRANTY. MANUFACTURER EXPRESSLY DISCLAIMS AND
EXCLUDES ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGE FOR BREACH OF ANY EXPRESSED OR
IMPLIED WARRANTY.
NOTE: Some states do not allow limitations on how long an implied warranty lasts, or do not allow the
limitation or exclusion of consequential or incidental damages, so the foregoing exclusions and limitations
may not apply to you.
OTHER: This warranty gives you specific legal rights, and you may also have other rights which vary from
state to state.
PROOF OF PURCHASE: Owner must provide proof of purchase in order to receive any warranty related services.
All service calls for explaining the operation of this product will be the sole responsibility of the consumer.
All warranty service must be provided by an Authorized FRIEDRICH Service Agency, unless authorized
by FRIEDRICH prior to repairs being made.
(2-10)
12
920-198-10
Friedrich Air Conditioning Co.
Post Office Box 1540 • San Antonio, Texas 78295-1540
4200 N. Pan Am Expressway • San Antonio, Texas 78218-5212
(210) 357-4400 • FAX (210) 357-4480
Printed in the U.S.A.
13
|
Earthquake Sound Speaker HoLeeS 12 User Manual
Faber Ventilation Hood 630006369 User Manual
Fagor America Electric Pressure Cooker uCOOK PRESSURE COOKER SET User Manual
Ferris Industries Lawn Mower 1000ZKAV21 48 User Manual
Fiat Automobile 11 User Manual
Fisher Price Child Tracker K7376 User Manual
FujiFilm Digital Camera S2 Pro User Manual
Fujitsu Network Card FMW43SA1 User Manual
Gamber Johnson Laptop Docking Station GD8000 User Manual
GE Water Dispenser GNSV70FBL User Manual