Extron electronic TV Mount WMK 100 User Manual

WMK 100 Installation Notes  
The Extron WMK 100 Wall Mounting Kit is used for hanging PoleVault® System A/V products on a wall near  
a flat screen display or short throw projector.  
The WMK 100 has a 13" x 13" x 2.5" deep enclosure to mount the  
PoleVault switcher and the power supply, with room for cable  
management. It also has knockouts on all four sides which allow  
external raceways to be used where necessary for cabling.  
(4) 1/4-20 x 2"  
Pan Head Bolts  
Maximum load for the WMK 100 is 15 lbs (7 kg).  
C
#40-375-01  
The key components (base plate and cover) of the WMK 100 are  
shown in figure 1.  
(4) 1/4" Kap Toggle Assemblies  
#40-374-01  
Included in the kit are:  
(4) 1/4" x 1 3/4" Masonry Screws  
#40-373-01  
(4) ¼-20 x 2" pan head bolts, (4) ¼" Kap toggle assemblies,  
(4) ¼ x 1¾" masonry screws, (4) #14 x 1¾" self tapping metal/wood  
screws, (4) 6-32 x ¼" button head hex screws.  
Not shown but included are (3) 4-40 x ¼" screws, (2) hook-and-loop  
straps.  
(4) #14 x 1 3/4" Self-tapping  
Metal/Wood Screws  
#40-372-01  
(4) 6/32" x 1/4" Button Head  
Hex Screws  
#40-363-17LF  
Figure 1 — WMK 100 parts  
Installation  
Refer to local building standards and codes to verify that the installation will meet the regulatory  
requirements. Observe all local and national building and safety codes, UL requirements, and ADA  
accessibility guidelines.  
N
Before installation identify the type of wall (masonry or non-masonry) and the location where the WMK 100 will be  
installed. This determines the installation approach and the type of fasteners needed to secure the plate to the wall.  
1. Mount the base plate  
WMK 100  
Base Plate Holes  
Mounting Cutout for  
Marker for  
Level Pilot Hole  
Follow the steps within 1A or 1B below, as applicable.  
Signal Cable  
Access  
The base plate can be installed over an existing electrical  
outlet. The opening fits standard sized 2.75" x 4.5" wall  
plates. See figure 2 (inset).  
N
1A. To mount the WMK 100 onto masonry walls:  
i. Hold the base against the wall, level it, and mark the  
positions of four slotted mounting holes (indicated by  
+ marks in figure 2). Set the plate aside.  
Use the top slot position at each mounting hole. Do not use  
both top and left slots as this will make it difficult to slide the  
plate down (see step iv).  
N
ii. Using a masonry drill bit, drill 1.75" (4.4 cm) deep pilot holes  
at the marked locations.  
iii. Screw in masonry screws until a gap of 1/8" to 3/8"  
Cutout for  
(3 to 9 mm) remains between the wall and the screw heads.  
Electrical  
Outlet  
iv. Align the base plate's slotted mounting holes over  
the installed screws, then slide the plate down so  
the screws fit into the slots.  
+
+
The plate can be aligned over an existing electrical outlet.  
v. At this time, lightly tighten all the screws to secure the plate  
Figure 2 — Masonry wall mounting  
to the wall and verify level and position.  
Do not over tighten, as the plate needs to be removed to attach the  
switcher and power supply before cabling.  
N
68-1738-01  
Rev A  
Proceed to Step 2.  
06 09  
1
 
3. Run cables  
700  
Run signal cables from the proposed PoleVault input wall plates,  
control device location, and the speakers to the WMK 100 location.  
Cables can be routed behind the walls, or through a surface raceway  
(e.g., Wiremold 700 or 2400 series) directly to the WMK 100.  
2400  
Raceway Option  
3A. If running cable behind the walls:  
i. Run all the cables from the various locations to the WMK and  
through the access hole.  
3B. If using a surface raceway:  
i. Attach the WMK cover to the base plate, then identify and  
mark the most suitable raceway entrance to the WMK 100.  
ii. Run the raceway from the signal source, speaker, and display  
locations to the marked raceway entrance at the WMK.  
iii Remove the WMK cover, and remove the desired knockout.  
iv. Attach the raceway to the wall and run cables from the sources  
Signal Cable Access  
Cutout Option  
and outputs through the raceway to the WMK.  
Figure 6 — Cabling run options  
4. Cable the switcher  
a. Connect the cables from the PoleVault transmitters, control device  
(MediaLink® Controller), speakers, and optional accessories (VoiceLift, Page Sensor Kit) to the rear ports of the  
switcher (see below). Refer to the PVS 305SA Setup Guide for additional details.  
If using a device other than a PVS 305SA (e.g., PVS 204SA Plus), refer to that device's user manual for details.  
N
b. Run VGA and composite video cables from the switcher to the output display device through the wall or  
where fitted, the raceway.  
c. Connect the power supply to the switcher and plug it in to the electrical outlet.  
If the electrical outlet is outside the WMK, pass the IEC power cable out through one of the raceway knockouts.  
N
Audio output  
to speakers  
Line out output  
(audio)  
PVS Terminal  
(left and right)  
Wire Color  
RGB signal input  
(2 CAT 5 cables, A and B  
with RJ-45 connectors)  
Red  
Black  
Positive (+)  
Negative (-)  
AUDIO  
IN  
OUT  
COMPUTER IN  
MONITOR OUT  
RGB #1B  
S
G
a
IR OUT  
RGB #1A  
f
g
N15779  
AMPLIFIED AUDIO OUT  
DO NOT  
GROUND  
OR SHORT  
SPEAKER  
OUTPUTS  
LINE OUT  
1A B  
2A RGB  
3A RGB  
4A RGB  
17TT  
US AUDIO/VIDEO  
APPARATUS  
PVT RGB D Plus  
®
2/4/8  
Ohms  
LISTED  
I
VOICELIFT  
RECEIVER  
N
P
U
T
S
OUTPUTS  
POWER  
L
R
R
CLASS 2 WIRING  
L
R
Power  
Connector  
VIDEO  
RGB  
L
10V  
50mA  
CONTROL  
Tx Rx IR 12V  
k
External  
Power Supply  
3B RGB  
4B RGB  
4B RGB  
4/VVIIDDEO  
1B RGB  
2B RGB  
PAGING  
SENSOR  
AUX AUDIO  
INPUT 5  
RS-232 MLC/IR  
12V  
5A MAX  
3/VVIDIDEEO  
O
VOL/MUTE  
(12 VDC, 5 A max.)  
b
d
e
i
c j  
h
RS-232 Control  
Composite video input  
(CAT 5 cable with  
RJ-45 connector)  
VGA  
Connector  
Paging  
Sensor  
RCA  
Connector  
Aux Audio  
Input 5  
V
VoiceLift  
Receiver  
RGB output  
to display  
+12 VDC  
Ground (  
)
)
Ground (  
Composite  
video output  
to display  
B
A
Receive (Rx)  
Transmit (Tx)  
VIDEO IN  
AUDIO IN  
L
R
DISPLAY  
ON  
OFF  
MLC  
Wire Colors PVS Switcher  
S
G
VCR  
DVD  
1
2
IR OUT  
A (Rx)  
B (Tx)  
Ground Drain Wire  
Ground Black  
12V In  
White  
Violet  
A (Tx)  
B (Rx)  
D (Ground)  
D (Ground)  
E +12 V  
VOLUME  
PC  
3
4
CONFIG  
PVT CV D  
Red  
MLC 104 IP PLUS  
Cabling the switcher  
3
 
WMK 100 Installation Notes, cont'd  
5. Final installation.  
a. After completion of cabling, place the cover over the installed plate,  
and secure at each corner with the provided 6-32 button head screws.  
Ensure any cables exiting the box (e.g., to display device and  
external electrical outlet) pass through a raceway knockout.  
N
R
G
b. Switch on the display device, control device, signal sources and  
A
GNI  
A
P
E
ENSVITY  
SIWTCHE  
T
U
K
SIGNAL  
PV305S  
A
V
NORMAL  
PAE  
T
PLOE  
CELIF  
O
V
MCI  
IOVELADJUS  
U
A
K
SIGNAL  
NROMAL  
PAE  
adjust and configure the system as needed.  
IPNUT  
UDIO  
XA  
5
U
A
4
3
2
For full configuration and setup details, refer to the PoleVault System  
Installation Manual, the MLC 104 Plus Series Reference Manual, and the  
PVS 305SA User's Manual, all available online at www.extron.com.  
PUSLECTION  
1
CNOFIG  
General Specifications  
Mounting  
Wall mount......................... Yes, with included hardware  
Maximum load capacity............... 15 lbs (6.8 kg)  
Material........................................... Steel  
Dimensions  
Figure 7— Attach WMK 100 cover  
Base plate............................ 12.8" H x 12.8" W x 0.5" D (32.5 cm H x 32.5 cm W x 1.3 cm D)  
Cover................................... 13.0" H x 13.0" W x 2.5" D (33.0 cm H x 33.0 cm W x 6.4 cm D)  
Product weight .............................. 4 lbs (1.8 kg)  
Shipping weight ............................ 6 lbs (3 kg)  
Vibration......................................... ISTA 1A in carton (International Safe Transit Association)  
Regulatory compliance  
Safety................................... c-UL, UL  
Warranty......................................... 3 years parts and labor  
Specifications are subject to change without notice.  
N
Both Sides  
2.5"  
(6.35 cm)  
Top View  
Both Sides  
13"  
12.83"  
(33.02 cm)  
(32.59 cm)  
Side View  
Side View  
Both  
13"  
(33.02 cm)  
Sides  
12.83"  
(32.59 cm)  
Base  
Extron USA - West Extron USA - East Extron Europe  
Extron Asia  
Extron Japan  
Extron China  
Extron Middle East  
Headquarters  
+800.633.9876  
+800.3987.6673  
+800.7339.8766  
+81.3.3511.7655  
+400.883.1568  
+971.4.2991800  
Inside USA / Canada Only  
Inside Europe Only  
Inside Asia Only  
Inside China Only  
Inside USA / Canada Only  
+1.919.863.1794  
+1.919.863.1797 FAX  
+31.33.453.4040  
+31.33.453.4050 FAX  
+65.6383.4400  
+65.6383.4664 FAX  
+86.21.3760.1568  
+86.21.3760.1566 FAX  
+1.714.491.1500  
+1.714.491.1517 FAX  
2009 Extron Electronics. All rights reserved.  
©
4
 

Dyson Vacuum Cleaner DC24 User Manual
Eagle Electronics Fish Finder 320 User Manual
Eureka Vacuum Cleaner 400 409 User Manual
Extron electronic Network Card AC AAP User Manual
Extron electronic Stereo Amplifier DA AV EQ User Manual
Fender Speaker SPL 1225 User Manual
Ford Automobile 2005 Ford GT User Manual
Ford Automobile Parts M 6007 B50 User Manual
Frigidaire Washer fwx233re User Manual
Generac Portable Generator 00941 3 User Manual