Garland Cooktop GI MO DU 10000 650 User Manual

Item: ______________________________  
Quantity: __________________________  
Project: ____________________________  
Approval: __________________________  
Date: ______________________________  
Induction Green Heat  
Garland Induction Built-in Unit RTCSmp Module-Line “Two Cooking Zones”  
Models:  
GI-MO/DU 7000-650  
GI-MO/DU 7000-720  
GI-MO/DU 10000-720  
GI-MO/DU 10000-650  
Garland Modular Induction built-in concept  
with two cooking zones consisting of:  
Induction generator, coil carrier sheet with  
coils and sensors, Ceran glass, control unit,  
as well as operation and cable kit.  
Equipped with the latest RTCSmp (Realtime  
Temperature Control System) technology.  
Standard Features  
Induction generator:  
Coil Carrier Sheet:  
Compact design with induction coils and sensors. Engineered  
specifically for modular kitchen designs.  
A powerful generator that is fully integrated in an enclosed  
housing and equipped with an integrated fan.  
Round Coil: One pan is used for each heat-zone. Round coils  
have higher power density and energy efficiency.  
All connections such as the mains cable, operation, CAN  
cable and sensor cable can be connected externally  
through plug connections.  
Safety above all:  
The generator is equipped with an air ducting system,  
through which the heated air is exhausted. Using this  
design, the risk of a thermal short-circuit is reduced.  
RTCSmp electronic temperature control that monitors the  
state of the induction coils, ceramnic glass, heat sink and  
electronics.  
Control unit:  
RTCSmp monitors the energy supply.  
The control unit is the information and diagnostic hub for  
the whole induction unit. It is connected with the generator  
via RJ45 cable. Compact design and easy to install using  
special installation tabs/brackets.  
Using a special control, interference noises are prevented  
when operating multiple cooking zones.  
Limiting the energy supply at peak load.  
Automatic monitoring when not cooking, also when using  
pans with a sandwich base.  
Operation unit:  
The power switch regulates the temperature in power levels  
1 to 12. Simple to operate; adjust the temperature setting  
simply by turning the knob.  
IR interface with diagnostic system.  
Optional Features  
Mounting Frame:  
Cable kit: 4m (SKU# 95000241) or 6 m (SKU# 95000242).  
Installation/mounting frame is included with unit.  
CE models comply with the latest European Norms:  
EN 60335-1, EN 60335-2-36, EN 62233 (EMC/EMV)  
North American models:  
ETL listed in compliance with  
UL 197, CSA C22.2 No.109, NSF-4  
Complies with FCC part 18, ICES-001  
Garland Commercial Ranges Ltd.  
1177 Kamato Road,  
General Inquiries 1-905-624-0260  
USA Sales, Parts and Service 1-800-424-2411  
Canadian Sales 1-888-442-7526  
Mississauga, Ontario  
L4W 1X4 CANADA  
Canada or USA Parts/Service 1-800-427-6668  
 
Mounting Frame 375 x 650 mm  
Mounting Frame 360 x 720 mm  
Garland Commercial Ranges Ltd.  
1177 Kamato Road,  
General Inquiries 1-905-624-0260  
USA Sales, Parts and Service 1-800-424-2411  
Canadian Sales 1-888-442-7526  
Mississauga, Ontario  
L4W 1X4 CANADA  
Canada or USA Parts/Service 1-800-427-6668  
 
Mounting  
Frame  
Inch (mm)  
Number  
of Round  
Coils  
Power per  
Cooking  
Zone  
Number of  
Cooking  
Zones  
Ceran Glass  
Inch (mm)  
Size of Coils  
Inch (mm)  
Total  
Rating  
Model  
010.63  
(0270)  
14.76x25.60x0.24  
(375 x 650 x 6 )  
14.76x25.60  
(375 x 650)  
GI-MO/DU 7000-650  
GI-MO/DU 10000-650  
GI-MO/DU 7000-720  
GI-MO/DU 10000-720  
2
2
2
2
3.5 kW  
5.0 kW  
3.5 kW  
5.0 kW  
2
2
2
2
7.0 kW  
10.0 kW  
7.0 kW  
010.63  
(0270)  
14.76x25.60x0.24  
(375 x 650 x 6 )  
14.76x25.60  
(375 x 650)  
010.63  
(0270)  
14.17x28.35x0.24  
(360 x 720 x 6 )  
14.17x28.35  
(360 x 720)  
010.63  
(0270)  
14.17x28.35x0.24  
(360 x 720 x 6 )  
14.17x28.35  
(360 x 720)  
10.0 kW  
Electrical Loading  
Model  
Watts  
208/60/3  
400/50/3  
440/50/3  
GI-MO/DU 7000  
7000  
22 amp  
30 amp  
11 amp  
10 amp  
GI-MO/DU 10000  
10000  
16 amp  
15 amp  
Technical Data  
Generator housing: 23.62x14.17x2.58” (600 x 360 x 65.5 mm)  
Network impedance (Zmax): 0.25 Ω  
Air flow fan: 4238 ft3/h (120 m3/h maximum)  
Cut out for air supply: 10.08 sq. in (6500 mm2, min)  
Cable Kit: 8.2 ft (2.5 m)  
Garland/ U.S. Range products are not approved or  
authorized for home or residential use, but are intended  
for commercial applications only. Garland/ U.S. Range  
will not provide service, warranty, maintenance or  
support of any kind other than in commercial applications.  
Form# GI-MO/DU 7000/10000-650/720 (04/29/14)  
Garland Commercial Ranges Ltd.  
1177 Kamato Road,  
General Inquiries 1-905-624-0260  
USA Sales, Parts and Service 1-800-424-2411  
Mississauga, Ontario  
Canadian Sales 1-888-442-7526  
Canada or USA Parts/Service 1-800-427-6668  
L4W 1X4 CANADA  
 

Cub Cadet Lawn Mower LTX 1040 User Manual
Cuisinart Coffeemaker DGB 625 User Manual
Dell Server 2450 User Manual
DMP Electronics Smoke Alarm XR2500F User Manual
Ducane Gas Grill 2020805 User Manual
Dynaudio Speaker BM 10S User Manual
Elation Professional Landscape Lighting LED 36 User Manual
Elation Professional Log Splitter RDMS6 User Manual
Fortinet Network Router ORTIWIFI 60A AM User Manual
Fostex Car Speaker FW187 User Manual