Quick Reference
C ATALYST 8 5 1 0 AN D
LIG H T ST R EAM 1 0 1 0
H AR D WAR E IN FO R M AT IO N
Ports and Cabling
P ORT ADAP TER/
INTERFACE MODULE
P ORTS
CABLE
CONNECTORS
10 /10 0 Ba s e T, T1 /E1 ,
CES , CE1 Fra m e Re lay
RJ -4 5 , RJ -4 8 c
10 0 Ba s e FX
MT-RJ fib e r
15 5 Mb p s , 6 2 2 Mb p s
CABLE
CONNECTORS
ROUTE P ROCES S OR
P ORTS
S C-t yp e fib e r
Ma n a g e m e n t p o rt
RJ -4 5
Gig a b it Et h e rn e t
BNC
E1 , CES , DS 3 /E3 , CDS 3
Co n s o le p o rt
EIA/TIA-2 3 2
2 5 Mb p s
9 6 -p in Mo lex
Replacing Com ponents
Se c u rin g a n ES D S t ra p
In s e rt in g a n In t e rfa c e Mo d u le
In s e rt in g a Po rt Ad a p t e r
WARNING: Always connect the ESD
wrist strap to the ESD strap connection
at the top left side of the chassis before
rem oving any com ponent.
In s e rt in g a n d Re m ovin g Fla s h P C Ca rd s
Ch a n g in g a Pow e r S u p p ly
In s e rt in g a New Fa n
WARNING: Always turn off the power supply unit
before rem oving it. While holding the AC or DC
power supply handle with one hand, place your
other hand underneath to support the bottom of
the supply.
LEDs and Troubleshooting
Distance and Pinout Inform ation
Maxim um Transm ission Distances
Pinouts to RJ -45 Connectors
The 10/100 Mbps Ethernet interface module with unshielded twisted-pair (UTP)
ports supports RJ-45 connectors.
Max. Distance
Between Stations
Transceiver Speed
10/100-Mbps Ethernet
100-Mbps Ethernet
1000-Mbps Ethernet
1000-Mbps Ethernet
25-Mbps ATM
Cable Type
Category 5 UTP
328 feet (100 m)
1640 feet (500 m)
1640 feet (500 m)
16404 feet (5 km)
328 feet (100 m)
9 miles (15 km)
18 miles (30 km)
1.2 miles (2 km)
9 miles (15 km)
Pin
1
Signal
RXD+
RXD–
NC
Description
Receive data +
Receive data –
No connection
No connection
No connection
No connection
Transmit data +
Transmit data –
Multimode fiber
Multimode fiber
2
Single-mode fiber
Category 5 UTP
3
4
NC
155-Mbps ATM
155-Mbps ATM
155-Mbps ATM
622-Mbps ATM
622-Mbps ATM
622-Mbps ATM
T1, 1.544-Mbps ATM
E1, 2.048-Mbps ATM
E1, 2.048-Mbps ATM
CDS3, 45-Mbps
CE1, 2.048-Mbps ATM
CES T1
Single-mode fiber
Single-mode fiber, long reach
Multimode fiber
5
NC
6
NC
7
TXD+
TXD–
Single-mode fiber
Single-mode fiber, long reach
Multimode fiber
8
1
25 miles (40 km)
1640 feet (500 m)
650 feet (198 m)
Pinouts to RJ -48c Connectors
Category 5 twisted-pair
Category 5 twisted-pair and FTP (120 ohm) 650 feet (198 m)
The T1, E1, CES T1 and CES E1 port adapters support RJ-48c connectors.
Coaxial cable (75 ohm)
Coaxial cable
650 feet (198 m)
450 feet (137 m)
650 feet (198 m)
650 feet (198 m)
Pin Description
1
2
3
4
5
6
7
8
Receive ring
Receive tip
Category 5 twisted-pair
Category 5 twisted-pair and FTP
No connection
Transmit ring
Transmit tip
CES E1
Category 5 twisted-pair and FTP (120 ohm) 820 feet (248.5 m)
CES E1
Coaxial cable (75 ohm)
Coaxial cable
650 feet (198 m)
450 feet (137 m)
1299 feet (396 m)
DS3, 45-Mbps
No connection
No connection
No connection
E3, 34-Mbps
Coaxial cable
1. If you are attaching a short cable to the 622-Mbps long-reach port adapter, you must add 10 dB of
attenuation to the cable or the transmitter might overdrive the receiver and introduce data errors.
Specifications and Regulatory Com pliance Inform ation
Description
Specifications
Description
Specifications
Switch and processor
capacity
10-Gbps shared memory, nonblocking switch fabric up to 32
KB frames
Memory
8-MB Flash memory SIMM (upgradable to 16 MB)
64-MB DRAM
256-KB boot EPROM
Dimensions (H x W x D)
Chassis: 10.4 x 17.25 x 18.4 in (26.4 x 43.1 x 46.0 cm)
Processor card and carrier module:
128-KB SRAM
1.2 x 14.4 x 16 in (3.0 x 36.6 x 40.6 cm)
Port adapter: 1.2 x 6.5 x 10 in (3.0 x 16.5 x 25.4 cm)
Power supply: 2.7 x 6.0 x 15.3 in (6.9 x 15.2 x 38.9 cm)
No Flash PC card installed by default (accepts 8-, 16-, or
20-MB Intel Series 2+ Flash PC cards)
Regulatory Compliance UL 1950 (U.S.A.)
CSA 950 (Canada)
Weight
Empty chassis: 32 lb (15.5 kg)
Fully populated chassis: approximately 130 lb (59.09 kg)
AC power supply: 11 lb (4.98 kg)
EN60950 (European Union)
IEC 950 (International)
DC power supply: 10 lb (4.54 kg)
AS/NZS 3260 (Australia/New Zealand)
TS001:1997 (Australia)
Airflow
95 cfm through the system fan assembly
°
°
Operating temperature
32 to 122 F (0 to 50 C)
21CFR1040 (Laser - U.S.A.)
°
°
Nonoperating temperature –40 to 167 F (–40 to 75 C)
EN60825 (Laser - European Union)
IEC60825 (Laser - International)
CE Marking (European Union)
Humidity
10 to 90%, noncondensing
Altitude
–500 to 10,000 ft (–52 to 3048 m)
100-Mhz MIPS R4700
FCC Part 15 (CFR 47) Class A (U.S.A.)
VCCI Class A with UTP and Class B with FTP cables (Japan)
Microprocessor
AC total output
AC-input voltage
AC frequency
388W maximum
EN55022 Class A with UTP and Class B with FTP cables
(European Union)
100-240 VAC wide input with power factor correction
CISPR 22 Class A with UTP and Class B with FTP cables
(International)
Auto sensing limits: 100 to 127/200 to 240 VAC, 8/4A, 47 to
63 Hz
AS/NZS 3548 Class A with UTP and Class B with FTP cables
(Australia/New Zealand)
AC current rating
Power supply load
8/4A with the chassis fully populated
376W maximum configuration, 200W typical with max
configuration
DC voltages supplied and System:
steady-state maximum
current ratings
+5V @ 70A
+12V @ 2A
+24V @ 0.2A
Processor: +5V @ 15A
+24V @ 25mA
+12V @ 500mA
Corporate Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
Tel: 408 526-4000
800 553-NETS (6387)
Fax: 408 526-4100
European Headquarters
Cisco Systems Europe
11, Rue Camille Desmoulins
92782 Issy Les Moulineaux Cedex 9
France
Tel: 33 1 58 04 60 00
Fax: 33 1 58 04 61 00
Americas
Headquarters
Asia Pacific Headquarters
Cisco Systems Australia, Pty., Ltd
Level 17, 99 Walker Street
North Sydney
NSW 2059 Australia
Tel: +61 2 8448 7100
Fax: +61 2 9957 4350
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
Tel: 408 526-7660
Fax: 408 527-0883
Cisco Systems has more than 200 offices in the following countries. Addresses, phone numbers, and fax numbers are listed on the
Ci s c o Co n n e c t i o n On l i n e We b s i t e a t h t t p :/ / w w w . c i s c o . c o m/ g o / o ffi c e s .
Argentina • Australia • Austria • Belgium • Brazil • Canada • Chile • China • Colombia • Costa Rica • Croatia • Czech Republic • Denmark • Dubai, UAE
Finland France Germany Greece Hong Kong Hungary India • Indonesia • Ireland • Israel • Italy • Japan • Korea • Luxembourg • Malaysia
•
•
•
•
•
•
Mexico • The Netherlands • New Zealand • Norway • Peru • Philippines • Poland • Portugal • Puerto Rico • Romania • Russia • Saudi Arabia • Singapore
Slovakia • Slovenia • South Africa • Spain • Sweden • Switzerland • Taiwan • Thailand • Turkey • Ukraine • United Kingdom • United States • Venezuela
Access Registrar, AccessPath, Any to Any, Are You Ready, AtmDirector, Browse with Me, CCDA, CCDE, CCDP, CCIE, CCNA, CCNP, CCSI, CD-PAC, the Cisco logo, Cisco Certified Internetwork Expert logo, CiscoLink, the Cisco Management Connection
logo, the Cisco NetWorks logo, the Cisco Powered Network logo, Cisco Systems Capital, the Cisco Systems Capital logo, Cisco Systems Networking Academy, the Cisco Systems Networking Academy logo, the Cisco Technologies logo, Fast Step, FireRunner,
Follow Me Browsing, FormShare, GigaStack, IGX, Intelligence in the Optical Core, Internet Quotient, IP/VC, IQ Breakthrough, IQ Expertise, IQ FastTrack, IQ Readiness Scorecard, The IQ Logo, Kernel Proxy, MGX, Natural Network Viewer, NetSonar,
Network Registrar, the Networkers logo, Packet, PIX, Point and Click Internetworking, Policy Builder, Precept, RateMUX, ReyMaster, ReyView, ScriptShare, Secure Script, Shop with Me, SlideCast, SMARTnet, SVX, The Cell, TrafficDirector, TransPath,
VlanDirector, Voice LAN, Wavelength Router, Workgroup Director, and Workgroup Stack are trademarks; Changing the Way We Work, Live, Play, and Learn, Empowering the Internet Generation, The Internet Economy, and The New Internet Economy are
service marks; and Aironet, ASIST, BPX, Catalyst, Cisco, Cisco IOS, the Cisco IOS logo, Cisco Systems, the Cisco Systems logo, the Cisco Systems Cisco Press logo, CollisionFree, Enterprise/Solver, EtherChannel, EtherSwitch, FastHub, FastLink, FastPAD,
FastSwitch, GeoTel, IOS, IP/TV, IPX, LightStream, LightSwitch, MICA, NetRanger, Post-Routing, Pre-Routing, Registrar, StrataView Plus, Stratm, TeleRouter, and VCO are registered trademarks of Cisco Systems, Inc. or its affiliates in the U.S. and certain
other countries. All other trademarks mentioned in this document are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company. (0005R)
Printed in the USA on recycled paper containing 10% postconsumer waste.
DOC-7810519=
78-10519-01
|