Installation Instructions
PAC501
DIMENSIONS
[657.2]
2X 25.88
ELECTRICAL CUTOUT
[581]
2X 22.88
DESIGNED TO FIT A SINGLE GANG
RACO 590, STEEL CITY CY ½ OR
SIMILAR STYLE ELECTRICAL BOX
[30.2]
[148.6]
2X 5.85
2X R1.19
[50.8]
2X 2.00
[304.8]
2X 12.00
[17.5]
2X R.69
[457.2]
2X 18.00
[97.9]
3.85
[711.2]
2X 28.00
[47.6]
4X 1.88
[101.6]
2X 4.00
[304.8]
2X 12.00
[508]
20.00
[458.2]
18.04
GROUNDING SCREW CONNECTIONS
[50.8]
2X 2.00
[24.9]
.98
MEASUREMENTS IN: [MILLIMETERS]
INCHES
[762]
30.00
3
PAC501
Installation Instructions
LEGEND
Tighten Fastener
Pencil Mark
Apretar elemento de fijación
Befestigungsteil festziehen
Apertar fixador
Marcar con lápiz
Stiftmarkierung
Marcar com lápis
Segno a matita
Serrare il fissaggio
Bevestiging vastdraaien
Serrez les fixations
Potloodmerkteken
Marquage au crayon
Loosen Fastener
Drill Hole
Aflojar elemento de fijación
Befestigungsteil lösen
Desapertar fixador
Perforar
Bohrloch
Fazer furo
Praticare un foro
Gat boren
Allentare il fissaggio
Bevestiging losdraaien
Desserrez les fixations
Percez un trou
Phillips Screwdriver
Adjust
Destornillador Phillips
Ajustar
Kreuzschlitzschraubendreher
Chave de fendas Phillips
Cacciavite a stella
Einstellen
Ajustar
Regolare
Afstellen
Ajuster
Kruiskopschroevendraaier
Tournevis à pointe cruciforme
Open-Ended Wrench
Llave de boca
Remove
Quitar
Gabelschlüssel
Chave de bocas
Chiave a punte aperte
Steeksleutel
Entfernen
Remover
Rimuovere
Verwijderen
Retirez
Clé à fourche
By Hand
Optional
Opcional
Optional
Opcional
Opzionale
Optie
A mano
Von Hand
Com a mão
A mano
Met de hand
À la main
En option
Hex-Head Wrench
Security Wrench
Llave de cabeza hexagonal
Sechskantschlüssel
Chave de cabeça sextavada
Chiave esagonale
Llave de seguridad
Sicherheitsschlüssel
Chave de segurança
Chiave di sicurezza
Veiligheidssleutel
Clé de sécurité
Zeskantsleutel
Clé à tête hexagonale
4
Installation Instructions
PAC501
TOOLS REQUIRED FOR INSTALLATION
3/16"
PARTS
Grounding screw and washer
installed at factory
Earthing symbol IEC 60418 No. 5019
affixed adjacent to grounding terminal.
A (1)
B (1)
G (4)
F (10)
C (8)
08 x 1/2"
M7 x 40mm
E (1)
M7
D (4)
M7 x 50mm
5
PAC501
Installation Instructions
INSTALLATION
Wood Studs
WARNING: IMPROPER INSTALLATION CAN RESULT IN
DEATH OR SERIOUS PERSONAL INJURY! This accessory
should be installed by qualified personnel.
Site Preparation
Locate and Prepare Mounting Site
1. Identify a suitable wall location for the in-wall enclosure.
IMPORTANT ! : The PAC-501 is designed for in-wall
installation spanning a minimum of three wood studs, 16"
on center. Installation of PAC-501 in 2x4 wall results in
nearly direct contact with vertical studs and back wall.
Inadequate space will remain for electrical wires/cables,
plumbing, ductwork, or insulation. Locate installation
accordingly.
(A)
WARNING: ELECTRICAL SHOCK HAZARD! CUTTING
OR DRILLING INTO ELECTRICAL WIRES OR CABLES
CAN CAUSE DEATH OR SERIOUS PERSONAL INJURY!
ALWAYS make certain area behind mounting surfaces is free
of electrical wires and cables before cutting, drilling, or
installing fasteners.
Figure 1
Frame Housing
The exposed portion of the center wood stud must be removed
and the resulting cavity completely framed with wood. The
following steps are suggested. The actual procedure is
dependent upon the specific installation.
WARNING: EXPLOSION AND FIRE HAZARD! CUTTING
OR DRILLING INTO GAS PLUMBING CAN CAUSE DEATH
OR SERIOUS PERSONAL INJURY! ALWAYS make certain
area behind mounting surfaces is free of gas, water, waste, or
any other plumbing before cutting, drilling, or installing
fasteners.
WARNING: STRUCTURAL FAILURE HAZARD! FAILURE
TO TAKE ADEQUATE PRECAUTIONS CAN LEAD TO
DEATH OR SERIOUS INJURY! Ensure removal of center
stud will not cause unacceptable loss of structural strength.
Consult a qualified building contractor and applicable building
codes.
2. Using a stud sensor, locate and mark studs.
3. Center and level housing between marked studs.
1. Remove exposed portion of center wood stud flush with
upper and lower drywall edges.
4. Using housing as a template, draw pencil line completely
around housing. (See Figure 1)
Support
Blocks
5. Cut drywall on outside edge of line and remove.
Horizontal Framing
Top View
Wood
Screws
(5 places)
(Typical for each
support block)
Figure 2
6
Installation Instructions
PAC501
2. Cut four 8" long support blocks out of 2x4 wood.
3. Using three #10 x 2-1/2" countersunk wood screws (not
provided), attach each support block to the studs (See
Figure 2)
NOTE: Ensure screws are far enough from block end to
prevent interference with framing screws installed in
Step 5.
(A)
4. If necessary, cut rectangular hole in horizontal framing to
accomodate the PAC-501 electrical box.
5. Attach horizontal framing to each support block with two
#10 x 2-1/2" countersunk wood screws (not provided).
(See Figure 2)
In-Wall Enclosure Installation
1. Install junction box (B) into the PAC-501 (A) using four
08 x 1/2" Phillips pan head tap screws (F). (See Figure 3)
(A)
Figure 4
WARNING: ELECTRICAL SHOCK HAZARD! CUTTING
OR DRILLING INTO ELECTRICAL WIRES OR
CABLES CAN CAUSE DEATH OR SERIOUS
PERSONAL INJURY! ALWAYS make certain area behind
mounting surfaces is free of electrical wires and cables
before cutting, drilling, or installing fasteners.
5. Drill four 3/16" diameter pilot holes in studs at side mounting
holes. (See Figure 5)
(D) x 4
6
(F) x 4
(B)
(G) x 4
Figure 3
2. Connect electrical wiring.
3. Route audio/visual cables into housing.
4. Center PAC-501 in opening and insert into opening. Align
front of box with front face of wall. (See Figure 4)
x
x 4
5
Figure 5
6. Attach the PAC-501 to side studs using four M7 x 50mm
Allen head connector screws (D) and mounting spacers (G)
using an M4 Allen head drill bit (E). (See Figure 5)
NOTE: The PAC-501 has 1/2" total clearance between the two
studs. The spacers allow side to side adjustment.
7
PAC501
Installation Instructions
USA/International
Europe
A
P
F
A
P
F
8401 Eagle Creek Parkway, Savage, MN 55378
800.582.6480 / 952.894.6280
877.894.6918 / 952.894.6918
Fellenoord 130 5611 ZB EINDHOVEN, The Netherlands
+31 (0)40 2668620
Chief Manufacturing, a division of
Milestone AV Technologies
+31 (0)40 2668615
Asia Pacific
A
Room 24F, Block D, Lily YinDu International Building
LuoGang, BuJi Town, Shenzhen, CHINA.
8807-000073 Rev A
¤2008 Milestone AV Technologies
10/08
P
F
+86-755-8996 9226
+86-755-8996 9217
|