KSA-1020
Installation Instructions
KSA-1020
LEGEND
Tighten Fastener
Pencil Mark
Apretar elemento de fijación
Befestigungsteil festziehen
Apertar fixador
Marcar con lápiz
Stiftmarkierung
Marcar com lápis
Segno a matita
Potloodmerkteken
Marquage au crayon
Serrare il fissaggio
Bevestiging vastdraaien
Serrez les fixations
Loosen Fastener
Drill Hole
Aflojar elemento de fijación
Befestigungsteil lösen
Desapertar fixador
Perforar
Bohrloch
Fazer furo
Praticare un foro
Gat boren
Allentare il fissaggio
Bevestiging losdraaien
Desserrez les fixations
Percez un trou
Phillips Screwdriver
Adjust
Destornillador Phillips
Ajustar
Kreuzschlitzschraubendreher
Chave de fendas Phillips
Cacciavite a stella
Einstellen
Ajustar
Regolare
Afstellen
Ajuster
Kruiskopschroevendraaier
Tournevis à pointe cruciforme
Open-Ended Wrench
Llave de boca
Remove
Quitar
Gabelschlüssel
Chave de bocas
Chiave a punte aperte
Steeksleutel
Entfernen
Remover
Rimuovere
Verwijderen
Retirez
Clé à fourche
By Hand
Optional
Opcional
Optional
Opcional
Opzionale
Optie
A mano
Von Hand
Com a mão
A mano
Met de hand
À la main
En option
Hex-Head Wrench
Security Wrench
Llave de cabeza hexagonal
Sechskantschlüssel
Chave de cabeça sextavada
Chiave esagonale
Llave de seguridad
Sicherheitsschlüssel
Chave de segurança
Chiave di sicurezza
Veiligheidssleutel
Clé de sécurité
Zeskantsleutel
Clé à tête hexagonale
3
Installation Instructions
KSA-1020
TOOLS REQUIRED FOR INSTALLATION
#2
7/64"
17/64"
1/2"
1/2"
PARTS
B(2)
C(4)
3"
A(1)
E(2)
1/4-20 X 1 3/4"
D(1)
G(2)
#12 X 2 1/2"
F(1)
3/8 X 1 1/4"
4
Installation Instructions
KSA-1020
buttons to reinstall them in the holes in which they will be
used.
ASSEMBLY AND INSTALLATION
Installation of Protective Rubber Edging
1. Place four strips of protective rubber edging (C) over the
sharp edges located on the top and bottom of the mount (A).
(See Figure 1)
•
•
If mounting vertically, move mounting buttons in
the four holes on top of the mount. (See Figure 3)
If mounting horizontally, move mounting buttons
in the top four holes on the back. (See Figure 3)
Horizontal button location
Vertical button location
(A)
1
(C) x 4
Figure 3
4. Loosen adjustment knob at the back of the mounting unit
and adjust height of mount to a height greater than the
height of the CPU to be installed. Loosen strap at the front
of the mount if necessary. (See Figure 4)
Figure 1
4
CPU Installation
1. Release bracket from mount by moving the flag to the open
position. (See Figure 2)
2. Remove bracket from mounting buttons on back of mount.
(See Figure 2)
2
Figure 4
1
5. Loosen adjustment knobs on top and bottom of the mount
and slide flanges in order to allow for the CPU to be inserted
for mounting. (See Figure 5)
NOTE: Top and bottom knobs can be removed and inserted
Figure 2
into the front square holes in order to allow for large
3. If hanging mount underneath desk, remove mounting
5
KSA-1020
Installation Instructions
CPU’s to be installed. (See Figure 5)
8. Tighten front strap to desired tension.
NOTE: Flanges may be reversed in order to allow for narrow
CPU’s to be installed in a secure manner. If this is
done, be sure to also to remove and reinstall strap so
that the buckle is facing out for easy adjustment.
WALL MOUNT INSTALLATION
WARNING: FAILURE TO PROVIDE ADEQUATE
STRUCTURAL STRENGTH FOR THIS MOUNT CAN
RESULT IN SERIOUS PERSONAL INJURY OR DAMAGE
TO EQUIPMENT! It is the installer’s responsibility to make
sure the structure to which this mount is attached can support
five times the combined weight of the mount and all
equipment attached to it. Reinforce the structure as required
before installing the mount.
5
NOTE: Mount may be installed using wood studs, steel studs
or it may be installed directly into drywall. For steel stud
and drywall installation, proceed ahead to Site
Requirements for Using Steel Studs section. For desk
mounting, proceed ahead to Desk Mounting
Installation section.
Mount Installation Using Wood Studs
1. Determine location for mount keeping in mind CPU size and
safety requirements.
Figure 5
2. Using the removed mounting bracket as a template, mark
and then drill two 7/64" diameter pilot holes through top and
bottom holes of wall bracket into wall structure. (See Figure
7)
6. Set CPU within mount (A). (See Figure 6)
7. Use adjustment knobs to compress mount around CPU until
CPU is tightly secured within mount (A). (See Figure 6)
(G) x 2
3
2
7
7
mounting bracket
Figure 7
3. Install two #12 x 2 1/2" round Phillips wood screws (G)
through bracket and drywall into wood stud. (See Figure 7)
4. Ensure bracket is vertical, then tighten screws (G).
NOTE: Proceed ahead to Mounting CPU to Wall section to
complete installation.
Figure 6
6
Installation Instructions
KSA-1020
Site Requirements for Using Steel Studs
WARNING: IMPROPER INSTALLATION CAN LEAD TO EQUIPMENT FALLING CAUSING SERIOUS PERSONAL INJURY
OR DAMAGE TO EQUIPMENT! The figure below identifies the minimum requirements for installation of display mounts onto a
steel stud structure. If the structure or its components do not meet these requirements contact the mount manufacturer for specific
instructions before attempting installation. It should also be noted that no other equipment should be mounted to the same stud.
16" or 24" (on center) Studs
Mount Installation Location
(Must be centered on stud)
If back side of wall is unfinished, drywall must be installed
to a minimum of one stud left and right of the stud(s)
being used to install the mount. Drywall must be
secured to studs with screws 12" on center
There must be a minimum of
1 7/8" (48mm) clearance
inside wall
FRONT
Drywall
**1/2"
minimum Drywall
Thickness
(Both Sides of Stud)
**See Hazard statement
on page 2!
Steel Stud (2 x 4 / 25ga minimum)
Stud type and structural strength must conform to the North American
Specification for the Design of Cold-Formed Steel Structural Members.
[362 S 125 18, C-Shaped, S-Stud Section]
Figure 8
7
KSA-1020
Installation Instructions
Wall Mounting Using Steel Studs or Drywall
After determining the site meets the installation requirements:
Steel Stud
Drywall
1. Identify desired mounting location on wall.
2. Using a stud finder or similar method locate stud.
3. Align mounting holes in mount with stud making sure
mounting holes are centered on stud. (See Figure 9)
Plastic Cap
WARNING: IMPROPER INSTALLATION CAN LEAD TO
EQUIPMENT FALLING CAUSING SERIOUS PERSONAL
INJURY OR DAMAGE TO EQUIPMENT!
8
4. Mark location of two mounting holes on wall using the wall
plate as a template. Mark holes where the top and bottom
holes of the bracket will be connected. (See Figure 9)
7
(B) x 2
Anchor Metal Channel
5. Drill two 1/2" holes. (See Figure 9)
(Side View)
Figure 11
5
4
9. Snap off plastic straps on anchor at wall by pushing side to
side, snapping off straps level with flange of plastic cap.
(See Figure 12)
1/2"x21/2"(
10. Repeat steps 6 through 9 for remaining mounting hole.
Steel Stud
Drywall
9
Plastic Cap
Mounting holes centered on stud
Figure 9
6. Hold metal channel on anchor (B) flat alongside plastic
straps and slide channel through hole. (See Figure 10)
Plastic Straps
Anchor Metal Channel
Drywall
Plastic Straps
6
(SIDE VIEW)
Figure 12
(B) x 2
11. Place mounting bracket over anchors and align mounting
holes in display mount with holes in anchors. (See Figure
13)
12. Insert 1/4-20 x 1-3/4" Phillips pan head screw (E) into
mounting hole on mounting bracket and into anchor (B) and
tighten until flush against mounting bracket. DO NOT
overtighten! (See Figure 13)
Figure 10
7. Holding plastic straps on anchor (B), pull anchor away from
wall until channel rests flush behind wall making sure
anchor channel is positioned vertically on stud. (See Figure
11)
13. Repeat steps 11 through 13 for remaining mounting hole.
8. Slide plastic cap on anchor (B) towards wall until flange of
cap is flush with wall. (See Figure 11)
8
Installation Instructions
KSA-1020
Steel Stud
Drywall
12
(E) x 2
13
3
(Flag in closed position)
Mounting Bracket
Anchor Metal Channel
Figure 15
(SIDE VIEW)
Desk Mount Installation
Figure 13
WARNING: Failure to provide adequate structural strength
for this component can result in serious personal injury or
damage to equipment! It is the installer’s responsibility to
make sure the desk to which this component is attached can
support five times the combined weight of all equipment.
Reinforce the structure as required before installing the
component.
Mounting CPU to Wall
CAUTION: Overtightening screws may cause wall bracket
to compress into soft wall surface resulting in difficult mount
installation.
1. Ensure bracket flag is in the open position. (See Figure 2)
NOTE: The following instructions are for mounting with full
360° swivel capability for easy cord access. If this
capability is not desired, connect mounting bracket
using two screws as demonstrated in the wall mounting
instructions.
2. Insert mounting buttons into the four large mounting holes
on the bracket. (See Figure )
1. Determine location for mount keeping in mind CPU size and
safety requirements.
2. Using bracket and bearing (D) as a template, mark and drill
one 17/64" diameter pilot hole through underside of desk at
desired mounting location. Ensure entire mount will clear
the outer edge of desk. (See Figure 16)
2
Figure 14
3. Move flag to closed position in order to fully secure mount
to bracket. (See Figure 15)
9
KSA-1020
Installation Instructions
desk
2
mounting bracket
(D)
(F)
3
Figure 16
3. Install 3/8 x 1 1/4" hex head lag screw (F) through bearing
(D) and bracket into hole drilled in Step 2. (See Figure 16)
4. Ensure bracket flag is in the open position.
5. Insert four mounting buttons into four mounting holes on the
bracket. (See Figure 17)
Figure 17
6. Slide buttons into locked position within holes.
7. Move flag to closed position in order to fully secure mount
to bracket. (See Figure 15)
10
Installation Instructions
KSA-1020
11
KSA-1020
Installation Instructions
USA/International
Europe
A
P
F
A
P
F
8401 Eagle Creek Parkway, Savage, MN 55378
800.582.6480 / 952.894.6280
877.894.6918 / 952.894.6918
Fellenoord 130 5611 ZB EINDHOVEN, The Netherlands
+31 (0)40 2668620
+31 (0)40 2668615
Chief Manufacturing, a division of
Milestone AV Technologies
Asia Pacific
A
Room 24F, Block D, Lily YinDu International Building
LuoGang, BuJi Town, Shenzhen, CHINA.
8834-000003
P
F
+86-755-8996 9226
+86-755-8996 9217
©
2008 Milestone AV Technologies
10/08
|