03166 INST 012206
03166 Wireless Digital Cooking Thermometer
Meat-taste temperature Quick Reference
TEMPERATURE
PROBE
WELL-DONE
170º
MEDIUM
160º
MED.-RARE
145º
RARE
140º
BEEF
GROUND BEEF
VEAL
POWER
OFF/ON
ALARM
OFF/ON
ALARM
OFF/ON
POWER
OFF/ON
COOK
160º
170º
170º
170º
180º
180º
N/A
160º
160º
160º
N/A
N/A
145º
145º
N/A
N/A
N/A
N/A
N/A
N/A
N/A
SET
ON
TIMER
THERMO
F
W
IR
E
L
E
S
S
LAMB
W
I
R
E
L
E
S
S
OFF
PORK
START/
STOP
HR
MIN
CHICKEN
TURKEY
N/A
MODE
N/A
N/A
WIRELESSPAGER
BASEUNIT
Do not return product to retail store.
INCLUDED IN THIS PACKAGE:
(1) Digital cooking thermometer base unit
(1) Digital cooking thermometer wireless pager
(1) 3 foot wire and thermometer probe
For Technical Assistance and product return information,
please call Chaney Instrument Co. direct at:
877-221-1252
Thank you for purchasing this Acu-Rite Wireless Digital Cooking
Thermometer. Please read all instructions prior to using this
instrument.
Features
• 3-line LCD shows cook temperature, set temperature and timer
for BBQ or Oven cooking.
• Programmable temperature alert
• High-temp stainless steel temperature probe with 3 foot cable
• Wireless pager alerts you of temperature
4
1
Battery Installation
Low Battery
Both the base unit and the wireless pager have low battery icons
that will display on the LCD if the battery is getting low.
Install 2 alkaline “AAA” (1.5v) batteries (not included) into both the
base unit and into the wireless pager. Slide the power switches on
both units to the “ON” position to activate each unit.
WIRELESS PAGER
Wireless Pager Alerts
The base station will alert the pager when the target temperature is
reached or when the timer on the base station reaches “0:00.” To
receive wireless data and alerts, be sure the pager is powered on
and that the alarm switch is activated.
BASE UNIT
Setting the clock and thermometer
To set the clock to the correct time, first press the “MODE” button
to enter into clock display mode. Next, hold the “MODE” button
down until the time display begins to flash; then you may adjust the
time using the “+HR” and “-MIN” buttons. Press the “MODE” button
to confirm your time setting.
The wireless pager receives data from the base station unit and
alerts you when the base stations’ temperature probe reaches a
certain pre-determined number. The pager also alerts you when the
base stations’ timer reaches “0:00.” The wireless pager also has a
built-in timer that can be used independently from the wireless
base-station.
At this point you may select between 12 and 24 hour time formats
by pressing the “HR” button. Then you may also choose ºC or ºF
temperature display mode by pressing the “-MIN” button. To exit
set-up mode and confirm your settings, press the “MODE” button.
The wireless thermometer system has a range of 100 feet, which
can be affected by electronic interference and certain building and
housing materials. When the pager cannot receive the signal from
the base station for whatever reason, the pager will read “OUT OF
RANGE” on the display and will beep.
Setting the target temperature
To set the target temperature, first press the “MODE” button until
the time/clock is displayed. Press the “+HR” and “-MIN” buttons to
set the target temperature. Slide the “alarm on/off” switch to “on”
and the alarm will sound when the actual temperature reaches the
target temperature.
Wireless Pager Backlight
The wireless pager has a built-in backlight for easy viewing. To
activate the backlight for 4 seconds, press any button on the front
of the pager.
Setting the timer
To set the timer, first press the “MODE” button to select TIMER.
Press the “+HR” and “-MIN” to adjust the timer to the desired
countdown time. Then press “START/STOP” to start and stop the
timer. To reset the count, stop the timer first and press “+HR” and
“-MIN” together at the same time. Slide the “alarm on/off” switch to
“on” and the alarm will sound when the timer countdown reaches
“0:00”.
Setting the pager timer
To set the timer, first press the “MODE” button to select TIMER.
Press the “+HR” and “-MIN” to adjust the timer to the desired
countdown time. Then press “START/STOP” to start and stop the
timer. To reset the count, stop the timer first and press “+HR” and
“-MIN” together at the same time. Slide the “alarm on/off” switch to
“on” and the alarm will sound when the timer countdown reaches
“0:00”. NOTE: both the base unit and the wireless pager must
be powered on and in range for the independent pager timer to
work properly.
Wireless Pager Alerts
The base station will alert the pager when the target temperature is
reached or when the the timer on the base station reaches “0:00.”
To receive wireless data and alerts, be sure the pager is powered on
and that the alarm is activated.
2
3
|