Bosch Appliances Home Security System DX4010I User Manual

DX4010i  
Installation Instructions  
RS-232 Serial Interface  
EN Module  
 
DX4010i | Installation Instructions | Contents  
Contents  
1.0  
2.0  
3.0  
4.0  
5.0  
5.1  
5.2  
5.3  
6.0  
7.0  
8.0  
General Information .......................................4  
Specifications ....................................................4  
Installation Standards .....................................4  
Wiring.................................................................5  
DX4010i Jumper Pin Settings ........................6  
Enable LED Jumper Pins (P2)...........................6  
DB9 Ground Enable Pins (P1)..........................6  
Address DIP Switches........................................7  
Remote Programming Direct Connection .7  
DB9 DTE RS-232 Connector (P6)................10  
RJ-16 Data Bus Connector (P3)....................11  
Figures  
Figure 1:  
Figure 2:  
Figure 3:  
Figure 4:  
Figure 5:  
Figure 6:  
Figure 7:  
Figure 8:  
Figure 9:  
DX4010i PCB Layout.................................4  
Control Panel Connections........................5  
External Power Supply Connections ........5  
Serial Device Connections .........................5  
Parallel Device Connections......................6  
P2 Jumper Settings ......................................6  
DIP Switch Location/Orientation .............7  
DB9 Connector Layout ............................10  
P3 Connector.............................................11  
Tables  
Table 1:  
Table 2:  
Table 3:  
Table 4:  
Table 5:  
DX4010i Specifications...............................4  
Diagnostic LED Functions .........................6  
Option Bus Address DIP Switch Settings.8  
SDI Bus Address DIP Switch Settings ......9  
Alternate Wiring Configuration...............10  
Bosch Security Systems, Inc. | 1/05 | 4998141106C  
3
 
DX4010i | Installation Instructions | 1.0 General Information  
1.0 General Information  
Figure 1: DX4010i Component Layout  
The DX4010i is a data terminal equipment (DTE)  
configured RS-232 serial device interface (SDI) module  
designed to operate with compatible control panels. It  
connects to the control panel through the option or  
SDI data bus.  
5
6
LED  
NABLE  
E
RxTx  
BUS  
TxR x  
SER  
P2  
P6  
4
7
The DX4010i is used to connect a PC with RPS, BIS,  
PC 9000, CMS 7000, or other third party software that  
uses a serial conncetion to the supported control  
panels. The module also supports a serial printer (or  
parallel printer with a convertor box) for control panels  
that support a serial printer. The compatibility lists in  
Table 1 show support information.  
3
2
P1  
DB9 GND  
ENA BLE  
P3  
1
1- DB9 GND enable pins (P1)  
2- RJ-16 data bus connector (P3)  
3- Data bus (TS1)  
4- Address DIP switches (S1)  
5- Diagnostic LEDs  
2.0 Specifications  
Table 1: DX4010i Specifications  
6- Diagnostic LED enable pins (P2)  
7- DB9 DTE RS-232 connector (P6)  
Operating  
Voltage  
12 VDC  
Current Draw  
50 mA nominal, 55 mA with diagnostic  
LEDs enabled  
3.0 Installation Standards  
Failure to follow the instructions in this  
manual can result in personal injury or  
damage to the equipment.  
Communication Programmable through the control  
panel. Refer to the appropriate control  
panel programming instructions.  
Configuration  
The baud rate for the printer output on a  
DS7400Xi must be greater than 300 baud.  
The DX4010i contains static-sensitive  
components and must be handled with  
care. Follow anti-static procedures when  
handling the modules.  
Operating  
0°C to +50°C (+32°F to +122°F)  
Temperature  
Relative  
Humidity  
Control Panel  
Compatibility  
5 to 85% @ +30°C (+86°F)  
non-condensing  
Test according to NFPA 72 if used in fire  
applications.  
Option bus control panels: D6412,  
D4412, DS7240, DS7220, DS7400Xi  
(v2.02 or higher)  
SDI bus control panels (v6.0 or higher):  
D9412G, D7412G, D7212G, D9124,  
D9112, D7412, and D7212  
1. Disconnect power to the control panel by  
unplugging the transformer and removing the red  
battery lead.  
2. Remove screws from enclosure cover to access the  
DX4010i board.  
Application  
Compatibility  
RPS: supported on all compatible  
control panels  
3. Connect circuit wiring and install jumper pins.  
Refer to Section 4.0 Wiring on page 5.  
4. Replace enclosure cover.  
5. Connect a serial cable to the serial device. Refer to  
Section 7.0 DB9 DTE RS-232 Connector (P6) on  
page 10.  
PC 9000: supported on SDI Bus  
control panels (D9412G, D7412G,  
D7212G, D9112, D7412, and D7212)  
BIS: supported on SDI Bus control  
panels, v6.3 and higher (D9412G,  
D7412G, and D7212G)  
CMS 7000: supported on DS7400Xi  
Control Panels set at Mode 18 (v3.09  
or higher)  
6. Reapply power to the control panel.  
Printers: supported on compatible  
Option Bus control panel  
4
Bosch Security Systems, Inc. | 1/05 | 4998141106C  
 
DX4010i | Installation Instructions | 4.0 Wiring  
4.0 Wiring  
Figure 3: External Power Supply Connections  
Remove all power to the control panel (AC  
1
2
and standby battery) before making or  
breaking any connections. Failure to do so  
can result in personal injury or damage to  
the equipment.  
3
4
Wire Length Restrictions  
5
6
0.8 mm (#22 AWG): 305 m (1000 ft)  
1.2 mm (#18 AWG): 610 m (2000 ft)  
SDI wiring is limited to 305 m (1000 ft).  
+
-
7
Connect the DX4010i to the control panel data and  
auxiliary power sources as shown in Figure 2.  
1- DX4010i data bus  
2- Control panel data bus  
Figure 2: Control Panel Connections  
3- Option AUX common/SDI common (black)  
4- Option data/SDI B (green)  
2
1
5- Option data/SDI A (yellow)  
6- Option AUX power +/SDI power (red)  
7- External 12 VDC power supply  
3
4
5
6
B
G
Y
R
Figure 4 shows serial device-to-DX4010i connections  
using the DB9 DTE RS-232 connector (P6).  
Figure 4: Serial Device Connections  
LED  
1- DX4010i data bus  
2- Control panel data bus  
ENABLE  
Rx Tx Tx Rx  
BUS  
SER  
P2  
P6  
3- Option AUX common/SDI common (black)  
4- Option data/SDI B (green)  
5- Option data/SDI A (yellow)  
6- Option AUX power +/SDI power (red)  
P1  
DB9 GND  
ENABLE  
If an external 12 VDC power supply is used, wire as  
P3  
shown in Figure 3.  
1
1- Serial (RS-232) device such as a PC (with  
RPS, BIS, PC9000, or other third party  
application) or a serial printer for supported  
control panels.  
See Section 7.0 DB9 DTE RS-232  
Connector (P6) on page 10 for additional  
information.  
Figure 5 shows a parallel printer connected to the serial  
output of the DX4010i. This type of connection  
requires the use of a serial to parallel converter, such as  
the BlackBox PI045A serial to Centronics parallel  
converter cable. The cable is available from  
BlackBox® (www.blackbox.com).  
Bosch Security Systems, Inc. | 1/05 | 4998141106C  
5
 
DX4010i | Installation Instructions | 5.0 DX4010i Jumper Pin Settings  
Figure 5: Parallel Device Connections  
Figure 6: P2 Jumper Settings  
LED  
ENABLE  
1
Rx Tx Tx Rx  
BUS  
SER  
P2  
P6  
LED  
ENA BLE  
R xTx  
B US  
TxR x  
SE R  
P2  
P6  
P1  
DB9 GND  
ENABLE  
P3  
P1  
2
DB 9G ND  
ENAB LE  
P3  
2
1
4
3
1- Parallel converter cable box (BlackBox P/N:  
PI045A  
2- Parallel printer (compatible option bus control  
panels only)  
1- Diagnostic LED enable pins (P2)  
2- DB9 GND enable pins (P1)  
3- Enabled  
4- Disabled  
5.0 DX4010i Jumper Pin  
Settings  
Table 2: Diagnostic LED Functions  
5.1  
Enable LED Jumper Pins (P2)  
Use the diagnostic LEDs for troubleshooting. To  
enable the LEDs, place a jumper plug across the  
jumper pins labeled P2.  
Diagnostic LED  
BUS RX  
Function  
Data bus receives data from control  
panel  
BUS TX  
SER RX  
SER TX  
Data bus transmits data to control panel  
RS-232 receives data from serial device  
RS-232 transmits data to serial device  
Refer to Figure 6 for jumper pin settings.  
The DX4010i draws more current when the  
diagnostic LEDs are enabled. Do not  
enable the diagnostic LEDs under normal  
operating conditions.  
5.2  
DB9 Ground Enable Pins (P1)  
Some devices connected to the DB9 DTE RS-232  
connector (P6) can cause a ground fault condition on  
the control panel. If this occurs, removing the plug  
across the P1 jumper pins can clear the ground fault  
condition.  
Some devices might still cause a ground  
fault even if the P1 jumper plug is removed.  
Refer to Figure 6 for jumper pin settings.  
6
Bosch Security Systems, Inc. | 1/05 | 4998141106C  
 
DX4010i | Installation Instructions | 6.0 Remote Programming Direct Connection  
5.3  
Address DIP Switches  
6.0 Remote Programming  
Direct Connection  
The address DIP switches are used to assign an address  
to the DX4010i.  
Refer to Table 3 for DIP switch option bus address  
settings.  
The DX4010i can be used to create a local direct  
connection for remote programming of a compatible  
control panel.  
Refer to Table 4 for DIP switch SDI bus address  
settings.  
Option Bus: Set the address DIP switches to  
Address 0. Refer to Table 3 on page 8.  
Refer to Figure 7 for proper DIP switch orientation.  
SDI Bus: Set the address DIP switches to Address 88.  
Refer to Table 4 on page 9.  
Figure 7: DIP Switch Location and Orientation  
LED  
ENAB LE  
RxTx  
BUS  
Tx Rx  
SER  
Consult your control panel’s installation guide for  
specific wiring connections.  
P2  
1
P6  
A DB9 to DB9 null-modem cable is  
required when using the direct connection  
method.  
P
1
DB9  
G
ND  
NABLE  
E
P3  
ON  
2
3
1
2
3
4
5
6
7
8
1
2
4
8
16  
32 64 128  
4
1- Address DIP switches  
2- ON position  
3- OFF position  
4- Address example (option bus Address 0)  
Bosch Security Systems, Inc. | 1/05 | 4998141106C  
7
 
DX4010i | Installation Instructions | 6.0 Remote Programming Direct Connection  
Table 3: Option Bus Address DIP Switch Settings  
DIP Switch Settings  
DIP  
Switches  
S1  
S2  
S3  
S4  
S5  
S6  
32  
S7  
64  
S8  
Module  
1
2
4
8
16  
128  
Address  
(Mode) (Option/SDI) (Checksum +1)  
0*  
1
ON  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
2
OFF  
OFF  
ON  
ON  
ON  
3
OFF  
ON  
ON  
ON  
4
OFF  
OFF  
OFF  
OFF  
ON  
ON  
5
OFF  
ON  
ON  
ON  
6
OFF  
OFF  
ON  
ON  
7
OFF  
ON  
ON  
8
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
9
OFF  
ON  
ON  
ON  
10  
OFF  
OFF  
ON  
ON  
11  
OFF  
ON  
ON  
12  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
13**  
14**  
15  
OFF  
ON  
ON  
OFF  
OFF  
ON  
OFF  
ON  
134  
135  
136  
137  
138  
139  
140  
141  
142  
143  
144  
145  
250  
251  
252  
253  
OFF  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
OFF  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
ON  
ON  
ON  
OFF  
ON  
ON  
ON  
ON  
ON  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
ON  
ON  
ON  
ON  
* Installer’s mode: Use for direct connection of remote programming and diagnostic tools.  
** DS7412 emulation  
The DS7400Xi (USA) only supports one DX4010i  
Option bus control panels: D6412, D4412, DS7240, DS7220, DS7400Xi (v2.02 or higher).  
8
Bosch Security Systems, Inc. | 1/05 | 4998141106C  
 
DX4010i | Installation Instructions | 6.0 Remote Programming Direct Connection  
Table 4: SDI Bus Address DIP Switch Settings  
SDI DIP Switch Settings  
SDI DIP  
Switches  
S1  
1
S2  
2
S3  
4
S4  
S5  
S6  
32  
S7  
64  
S8  
Module  
8
16  
128  
Address  
(Mode) (Option/SDI) (Checksum +1)  
80*  
81  
ON  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
82  
OFF  
OFF  
ON  
ON  
ON  
83  
OFF  
ON  
ON  
ON  
84  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
85  
OFF  
ON  
ON  
ON  
86  
OFF  
OFF  
ON  
ON  
87  
OFF  
ON  
ON  
88**  
89  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
8A  
8B  
8C  
8D  
8E  
8F  
OFF  
OFF  
ON  
ON  
OFF  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
OFF  
Positions 5, 6, and 8 are not used for SDI bus.  
* Used for BIS, PC 9000, and other third party applications.  
** Used for RPS and alternate communication.  
SDI bus control panels (v6.0 or higher): D9412G, D7412G, D7212G, D9124, D9112, D7412, and  
D7212.  
Bosch Security Systems, Inc. | 1/05 | 4998141106C  
9
 
DX4010i | Installation Instructions | 7.0 DB9 DTE RS-232 Connector (P6)  
7.0 DB9 DTE RS-232  
Figure 8: DB9 Connector Layout  
Connector (P6)  
The DX4010i serial port is wired as a DTE device.  
1
2
3
4
5
If the connected device is a data carrier  
equipment (DCE) device (most common, such  
as an external modem), a straight through 9-pin  
to 9-pin, or (DTE to DCE) 9-pin to 25-pin cable  
may be used.  
6
7
8
9
If the connected device is a DTE device (such as  
a PC serial port), a null-modem (DTE to DTE)  
9-pin to 9-pin, or null-modem 9-pin to 25-pin  
cable is required.  
1- DCD  
2- RxD  
3- TxD  
4- DTR  
5- GND  
6- DSR  
7- RTS  
8- CTS  
9- RI  
Consult the operating manual provided with your  
compatible device for wiring requirements.  
If you are using an alternate configuration, you must  
make a custom cable (refer to Figure 8 and Table 5).  
Table 5: Alternate Wiring Configuration  
DX4010i  
9-Pin DTE  
Connector  
DCE  
(9-pin)  
DTE  
(9-pin)  
DCE  
(25-pin)  
DTE  
(25-pin)  
1: DCD  
1: DCD  
1: DCD 8: DCD  
8: DCD  
(not used)  
2: RxD  
3: TxD  
4: DTR  
5: GND  
6: DSR  
7: RTS  
8: CTS  
9: RI  
2: RxD  
3: TxD  
4: DTR  
3: TxD  
2: RxD  
3: RxD  
2: TxD  
2: TxD  
3: RxD  
6: DSR 20: DTR 6: DSR  
5: GND 5: GND 7: GND 7: GND  
6: DSR  
7: RTS  
8: CTS  
9: RI  
4: DTR  
8: CTS  
7: RTS  
9: RI  
6: DSR  
4: RTS  
5: CTS  
22: RI  
20: DTR  
5: CTS  
4: RTS  
22: RI  
(not used)  
10  
Bosch Security Systems, Inc. | 1/05 | 4998141106C  
 
DX4010i | Installation Instructions | 8.0 RJ-16 Data Bus Connector (P3)  
8.0 RJ-16 Data Bus Connector  
(P3)  
Figure 9: P3 Connector  
LED  
ENABLE  
RxTx Tx Rx  
BUS SER  
P2  
P6  
P1  
DB9 GND  
ENABLE  
1
P3  
1- RJ-16 data bus connector (P3)  
For remote programming connection, use one of the  
two cables supplied: RJ-16 to molex for control  
panels with the data bus provided on a header (such  
as the D6412 or DS7240) or the RJ-16 to spade lugs  
for terminal strip connections (such as the D9412).  
Bosch Security Systems, Inc. | 1/05 | 4998141106C  
11  
 
Bosch Security Systems  
130 Perinton Parkway  
Fairport, NY 14450-9199  
Customer Service: (800) 289-0096  
Technical Support: (888) 886-6189  
© 2005 Bosch Security Systems  
4998141106C  
 

Belkin Network Card F5D8011tt User Manual
Black Decker Saw 606404 00 User Manual
Bogen Wireless Office Headset ADP1 User Manual
Bosch Appliances Dishwasher SHE46C06UC User Manual
Bose Stereo System AM352156 User Manual
Cables Unlimited Headphones SPK SHOWER User Manual
Cambridge Audio Stereo Receiver AR30 User Manual
Campbell Hausfeld Nail Gun IN730400AV User Manual
Chauvet Baby Accessories LED PAR 56 24UVB User Manual
Christie Digital Systems Projector CX50 User Manual