Bel Canto Design Stereo Amplifier eVo2iTM User Manual

User's Guide  
eVo2i  
Two Channel Integrated Audio Amplifier  
Bel Canto Design, LTD.  
212 Third Avenue North  
Minneapolis, MN 55401  
Phone: (612) 317.4550  
Fax: (612) 359.9358  
©2002-2004 Bel Canto Design, LTD  
 
Unpacking  
eVo2i box contents include the following:  
1 (one) - eVo2i Integrated Amplifier  
1 (one) - eVo2i User’s Guide  
1 (one) - Power cord  
1 (one) - Remote Control  
Carefully unpack each piece and check  
for shipping damage. If there is any  
damage, or if anything is missing,  
please contact your dealer, distributor or  
Bel Canto Design.  
IMPORTANT: Save all packing  
materials as the packing is spe-  
cially designed to protect the  
unit during transportation or shipping. If  
the packaging becomes lost or dam-  
aged, please contact your dealer, dis-  
tributor or Bel Canto before attempting  
to transport your unit.  
Power Connection  
The power supply on the eVo2i is preset  
for the proper national voltage. The  
power cable should have the correct  
plug for your local power system. If you  
believe this to not be true, please con-  
tact your dealer immediately.  
This integrated amplifier, like any electri-  
cal component, can be dangerous and  
cause injury unless correct handling pro-  
cedures are observed and used. Before  
powering this preamplifier it is neces-  
sary to read and follow proper setup  
and procedures.  
Warning!  
Do not connect power to this  
preamplifier yet!  
© 2002-2004 bel canto design, Ltd.  
page 3  
eVo2i User’s Guide rev081104  
 
Placement and Initial Setup  
Because the eVo2i runs cool it can be  
Single Ended RCA and Balanced XLR  
connectors are available. XLR jacks  
allow balanced hookup using the stan-  
dard pin configuration:  
placed in many system locations without  
compromise. We do not recommend  
placing weights or other objects directly  
on the eVo2i. This may mar or scratch  
the chassis finish. Do not use harsh  
chemicals when cleaning the outside of  
your eVo2i.  
Pin 1 Ground  
Pin 2 Input +  
Pin 3 Input -  
IMPORTANT: Make all connections before powering your unit.  
Design Features  
• The elegant simplicity of the signal path  
• Efficiency >90% insures cool operation.  
• THD and IMD <0.05%  
and gain stage allows the eVo2i to pre-  
serve audio signal quality. Audio Grade  
decoupling capacitors and resistors, star  
grounding and careful signal routing insure  
that low-level signals are preserved.  
• Damping Factor >100  
• High thermal stability in all stages  
• Fully regulated, low noise supplies for all  
analog stages  
• Input processing provides one balanced  
XLR connection, three RCA jack connec-  
tions and Tape In. Tape Output is an RCA  
output with an active audio-grade buffer to  
isolate the internal signal bus from the tape  
output. Line out RCA connection offers flexi-  
bility of use with a sub woofer, external  
amplifier for bi-amping or outboard signal  
processor.  
• Soft clipping with uncompromised low  
level distortion performance  
• Ultra-low power dissipation for ‘green’  
amplification  
• Protection circuitry outside signal path  
• Programmable features allow you to dis-  
able (except TAPE), name and set volume  
for listening and soft mute levels for ALL  
inputs individually  
• The volume control is a precision analog  
stepped attenuator controlled by a micro-  
controller. This device provides extremely  
low noise and distortion coupled with high  
accuracy. The sonic quality is superior to  
the best potentiometers and insures no  
wear.  
• The eVo2i powers on in Soft Mute Mode.  
Soft Mute Mode is a fully adjustable setting  
that also can be selected as a muting  
option during regular listening.  
• High efficiency Digital Power Processing  
eVo power amplifier.  
© 2002-2004 bel canto design, Ltd.  
page 4  
eVo2i User’s Guide rev081104  
 
Conditioning  
The eVo2i’s sonic performance will start  
to stabilize after 100 hours of continu-  
ous power up.  
Front Panel and Remote Controls  
Volume Up:  
Balance Left: (available from the  
remote only)  
Increases the output level in 0.5 Decibel  
(dB) steps from 0.0 to 100.0.  
Shifts balance left in 0.5dB steps. It is  
also used to scroll left in the setup menu.  
Volume Down:  
Decreases the output level.  
HARD MUTES OUTPUT, DISABLES DISPLAY  
AND CONTROLS  
VOLUME AND BALANCE CONTROLS  
AND NAVIGATION FOR SETUP MENUS  
INPUT SELECTION  
TOGGLES DISPLAY ON/OFF  
CYCLES THROUGH INPUTS  
PRESS 7 TIMES TO  
ACCESS SETUP MENUS  
SELECTS TAPE INPUT  
© 2002-2004 bel canto design, Ltd.  
page 5  
eVo2i User’s Guide rev081104  
 
Balance Right: (available from the  
MAIN:  
remote only)  
Cycles through the main inputs. It is also  
used to scroll to the left in the setup  
menu.  
Shifts balance right in 0.5dB steps. It is  
also used to scroll right in the setup  
menu.  
LOOP: (available from the remote only)  
This is used to cycle through the inputs.  
INPUT:  
MUTE:  
The eVo2i starts up in Soft Mute. This  
level is 20dB below the displayed vol-  
ume level. When MUTE is first pressed it  
goes to the Soft state, pressing MUTE  
again within 3 seconds will fully MUTE  
the outputs.  
On the remote the Numbered Buttons (1-  
5) allow you to select between the active  
inputs. From the remote, you can cycle  
through inputs using the LOOP button.  
From the front panel, you can cycle  
through inputs by pressing the MAIN  
button. When switching between inputs,  
the eVo2i will quickly ramp down the  
volume, switch inputs, then quickly ramp  
back up to the programmed volume set-  
ting.  
ENTER:  
This control button is pressed and held  
on the front panel or pressed 7 times on  
the remote to enter into the menu setting  
functions described below. It is also used  
to enter into specific modes within the  
menu system.  
VOLUME CONTROL  
AND UP/DOWN KEYS*  
PRESS ENTER AND HOLD TO  
TAPE INPUT SELECT*  
ACCESS SETUP MENU*  
SOFT AND FULL  
MUTE FUNCTIONS  
MUTES OUTPUT, DISABLES DISPLAY  
AND CONTROLS  
MAIN INPUT SELECT*  
*ALSO USED FOR NAVIGATING THE SETUP MENU  
© 2002-2004 bel canto design, Ltd.  
page 6  
eVo2i User’s Guide rev081104  
 
TAPE:  
STANDBY:  
On both the remote and the front panel,  
the TAPE select between the active main  
input or the tape input  
When in STANDBY mode the red LED is  
engaged, the display is off and the out-  
puts are muted. The unit remains  
warmed up and ready for use when  
taken out of standby.  
It is also used to scroll to the right in the  
setup menu.  
eVo2i Back Panel  
Inputs 1 to 4  
the Main input selector is be routed to  
the buffered Tape Output.  
Standard line level inputs. Input 1 is bal-  
anced and may be used with unbal-  
anced sources using an RCA to XLR  
adapter.  
Line Out  
Line Out is a buffered preamplifier out-  
put which tracks the volume setting on  
the front panel. This can be used to  
drive the line level input on a subwoofer,  
for example.  
Tape In/Tape Out  
Tape loop function: Tape In selected  
routes the Tape In jacks to the main out-  
puts. The main input 1-4 selected with  
© 2002-2004 bel canto design, Ltd.  
page 7  
eVo2i User’s Guide rev081104  
 
Loudspeaker Connection  
Connect loudspeakers to the outputs of the  
would result in one of the red (positive) out-  
puts being connected to ground and cause  
the amplifier to go into protection mode and  
shut itself off.  
eVo amplifier using the 5-way binding posts  
located the rear of the amplifier. The red or  
black center plug in the output post can be  
removed for use with banana type connec-  
tors (all non CE countries). Do not connect  
speaker terminals to a ground connection.  
Make certain that no connection from the  
output terminals is made to a chassis or  
earth ground.  
The Anti-Phase operation of the outputs  
Setup Menu Options  
A) INPUTS CONFIGURATION Menu  
cator left or right using the LEFT/RIGHT  
keys and use the UP/DOWN keys to  
scroll through capital and lower case let-  
ter, numbers 0-9 and a SPACE.  
This menu is used to customize the input  
options.  
It is used to set:  
You can use the SPACE to separate words  
and numbers or to center short names like  
CD. Press Enter to exit this menu mode.  
1) Input Function  
2) Input Name  
3) Initial Volume level  
4) Soft Mute level  
3) The third menu level is used to set the  
Initial Volume level.  
1) The first level of this menu is used to set  
the INPUT FUNCTION. The options are  
Stereo or Disabled.  
Press ENTER and use the UP/DOWN  
keys to set the default level when coming  
out of STANDBY. Press ENTER to exit this  
menu mode  
Change these settings by scrolling left or  
right to the desired input and pressing  
ENTER to change the setting. Use the  
UP/DOWN keys to scroll through the set-  
ting options. Disable unused inputs.  
.
4) The fourth menu level is used to set the  
Soft Mute Level.  
This is preset to -20 dB. This is generally a  
good soft mute level.  
Press ENTER to exit this menu mode.  
If you wish to change this for a given  
input then press ENTER and use the  
UP/DOWN keys to scroll to a different  
setting.  
2) The second level of this menu is used  
for changing the Name of a given input.  
To change an input name press ENTER  
and you will see an under-bar indicator  
for each of the 8 characters that can be  
used for naming the input. Scroll the indi-  
Press Enter to exit this menu mode.  
© 2002-2004 bel canto design, Ltd.  
page 8  
eVo2i User’s Guide rev081104  
 
Setup Menu Options  
B) SAVE CONFIG ? Menu  
Press ENTER to save your configuration  
and exit this menu mode.  
This is used to Save the Setup Changes  
made in the menu system.  
C) ERASE CONFIG ? Menu  
Be sure to use this to store the changes  
when you are satisfied with your setup.  
Use the UP/DOWN keys to toggle  
between YES or NO and save the menu  
settings.  
This is used to Restore the Factory  
Default menu settings.  
Use the UP/DOWN keys to toggle to  
YES or NO.  
Saving the settings will insure that your  
changes are active even if power is  
removed from the eVo2i.  
Press ENTER to erase your configuration  
and restore the factory settings.  
Warning: This operation resets all of  
your custom settings.  
© 2002-2004 bel canto design, Ltd.  
page 9  
eVo2i User’s Guide rev081104  
 
Specifications  
Power output per channel into 8 ohms • 120 watts <1% THD+N  
Power output per channel into 4 ohms • 200 watts <1% THD+N  
Bandwidth: +/- 3dB •1Hz-80KHz  
Volume setting for unity gain • 84.0 (Inputs to Line output)  
Input for full output with volume set to 84.0 • 1.9V RMS  
Signal to Noise Ratio @ 1 watt out • >96 dB A weighted, 20 kHz  
Distortion @ 1 watt/1kHz • <0.05%  
Damping Factor • >100  
Input configuration and impedance,single-ended/balanced • 10 Kohm/20 Kohm  
Gain • 16 dB Preamplifier section, 23 dB Amplifier section  
Standby power • 15 Watts  
Maximum power • 500 Watts  
Input Overload, Single Ended/Balanced • 10V RMS  
Power Requirements • 100-120 VAC 50-60 Hz or 220-240 VAC 50-60 Hz  
Dimensions • 17.5" W x 14.5" D x 4.5" H (445 mm x 368 mm x 114 mm)  
Weight • 37 lbs. (13 kg)  
© 2002-2004 bel canto design, Ltd.  
page 10  
eVo2i User’s Guide rev081104  
 
© 2002-2004 bel canto design, Ltd.  
page 11  
eVo2i User’s Guide rev081104  
 
Bel Canto Design, LTD.  
212 Third Avenue North  
Minneapolis, MN 55401  
Phone: (612) 317.4550  
Fax: (612) 359.9358  
©2002-2004 Bel Canto Design, LTD  
eVo2i is a trademark of Bel Canto Design, LTD  
 

Belkin Door W1896B 03 01 User Manual
Black Box Power Supply APC Switched Rack PDU User Manual
Bloomfield Fryer WFPE 30F User Manual
Blue Rhino Outdoor Fireplace WAD911W1 User Manual
BOXLIGHT Projector CP755ew User Manual
Broan Ventilation Hood QL1 Series User Manual
Brother Printer P touch 2310 User Manual
Califone Headphones 2985PG User Manual
Canon All in One Printer PIXMA MX420 User Manual
Casio Watch MA0804 EC User Manual