Sunbeam Air Cleaner 2540 User Manual

Model s 2540/ 2541  
USE AND CARE MANUAL  
CAUTION:  
These guidelines and safeguards help ensure that your new  
air cleaner operates effectively. Please read all instructions  
carefully before using your appliance.  
QUESTIONS: If you have questions or comments please call us at  
l-800-597-5978  
 
When using electrical appliances, basic safety precautions  
should always be followed, including:  
1. READ ALL INSTRUCTIONS CAREFULLY.  
2 . To reduce the risk of electrical shock, this equipment has a grounded  
type of plug that has a third (grounding) pin. This plug will only fit into  
a grounded type of power outlet. If the plug does not fit into the outlet,  
contact qualified personnel to install the proper outlet. Do not alter the  
plug in any way.  
3. Keep the cord out of high traffic areas. To avoid fire hazard,  
never put the cord under rugs, near heat registers, radiators, stoves  
or heaters. Keep the cord away from heated surfaces.  
4 . Do not immerse in water or other liquids. Do not use while bathing.  
5 . Close supervision is necessary when any appliance is used near  
children or incapacitated persons.  
6 . Always unplug the air cleaner before moving it, cleaning or changing  
filters, or whenever the air cleaner is not in use.  
7 . Do not put foreign objects inside the air cleaner  
8 . Do not operate this appliance with a damaged cord or plug, or if the  
fan fails to rotate, or has been dropped or damaged in any manner.  
Return the appliance to manufacturer for examination or repair.  
(See warranty for information)  
9 . Use appliance only for intended household use as described  
in this manual.  
IO. Do not use outdoors.  
11. Never block the air opening or place on a soft surface such as  
a bed or sofa where the opening may be blocked.  
12. Laser light present. Do not attempt to service or disassemble  
the unit yourself.  
 
ON YOUR  
The  
Air Cleaner is the first and only air cleaner  
made today that detects and monitors the level of allergen particles in the air.  
If you have any questions or comments, please feel free to call us at  
I-800-597-5978. Our customer service representatives will be happy  
to assist you.  
REVOLUTIONARY  
TECHNOLOGY DETECTS AND MONITORS  
THE LEVEL OF AIRBORNE ALLERGENS...  
WUY ALLERGYSMART”?  
Many doctors agree that air cleaners help to reduce allergy and  
related symptoms by reducing allergen particles in the air. These allergens  
may include, among others, dust mites, pet dander, mold spores, and pollen  
from weeds, trees, or grasses. Only with the  
sensor do you  
get monitoring and feedback about the level of allergen particles in your  
air-and the confidence you need that your indoor air is improved.  
HOW MANY ALLERGENS ARE IN MY HOME?  
The types of allergens and the level  
of allergens in your home vary  
widely depending on the environment  
(different parts of the country, seasons  
of the year, etc.) the age of your home,  
the activity level within your home, and  
the presence of pets.  
Approximately 95% of all allergens  
range in size from 3 to 50 microns.  
dirt, dust, fibers  
dust mites  
The  
sensor measures  
level of these allergen sized particles  
in the room.  
pet  
dander  
 
Independent research in various rooms and homes conducted by the Stevens  
institute of Technology shows that these levels of allergen sized particles vary  
from 10 to over 1,000 particles in the home. Allergen particle levels will be  
affected by room type and/or activity level in your home.  
In-Home Particle Counts  
n
mom  
0
l
Den  
REDUCING TUE LEVEL OF ALLERGENS IN THE HOME  
There are steps you can take to reduce the level of allergens in your home  
in addition to the use of an Allergysmart air cleaner. Following are some  
suggestions to help minimize your families exposure:  
Pollens  
l
l
l
Keep windows closed during pollen seasons  
Bathe and wash hair at night to prevent bringing allergens to bed  
Use a True HEPA air cleaner  
Pets  
l
l
Keep pets outdoors or out of your bedroom  
Wash hands immediately after handling  
Vacuum frequently  
l
Dust Mites  
l
l
Use allergy proof covers on mattresses and pillows  
Wash bed linens weekly in hot water  
l
l
Vacuum daily and dust frequently  
Replace carpeting with hardwood floors  
l
Use a dehumidifier-dust mites thrive in high humidity  
 
A
Mold Spores  
l
l
Use a dehumidifier  
No potted plants inside the home  
Remove visible mold growing in bathroom and/or kitchen  
l
HOW THE  
SENSOR ACTUALLY WORKS:  
The  
sensor was designed to detect and measure the level  
of allergen-sized particles (3-50 microns) in the air. While the sensor does not  
detect smaller sized particles such as dust or smoke, these particles will be  
captured by the HEPA filter. Here’s how it works:  
1. The fan in the sensor constantly samples the air.  
2. A laser beam light in the sensor measures the level of allergen sized particles  
in the sampled air and sends a signal to the air cleaner.  
3. When the level of particles exceeds the setting you choose (average, extra,  
super), the sensor automatically turns on the air cleaner for 30 minutes.  
After 30 minutes, the air cleaner turns off and the sensor resamples the air.  
If the level of particles exceeds the sensitivity setting you chose, the sensor  
turns on the air cleaner for another 30 minutes, and will continue to run and  
resample in 30 minute intervals until the allergen particle level has been  
reduced.  
4. Lights on the control panel indicate the level of allergen particles.  
 
ADJUSTING THE SENSITIVITY SETTING OF TUE  
SENSOR  
You can adjust the operation of the air cleaner by changing the sensitivity  
setting of the sensor (average, extra, super). The higher the sensitivity  
setting, the fewer the particles counted before the air cleaner comes on.  
The chart below shows the particle counts that activate the air cleaner  
at the various settings*.  
S u p e r  
Extra  
Average  
1 5  
60  
160  
*Particle counts indicated are mean averages. Slight variations exist from unit to unit. Sensitivity levels will vary among  
individuals based upon factors such as level and type of individual allergic reactions and personal concerns.  
TO RUN YOUR AIR (LEANER AUTOMATICALLY USING TUE  
SENSOR....  
Your air cleaner will run automatically, turning  
on and off, depending on the level of allergen-  
sized particles in the air sampled and the  
sensitivity setting you have selected. The  
automatic mode is activated by selecting a  
position on the sensitivity dial setting  
(average, extra, super) other than OFF/manual.  
Once one of these sensitivity settings is  
selected, select your preferred fan speed  
(sleep, low, medium, or high).  
The  
sensor is now activated.  
You will see a blinking green light, indicating  
that the sensor is testing.  
c h e c k  
s e t t i n g  
Q u a l i t y  
 
At the end of the testing interval, (up to 30 seconds) the display will indicate the  
level of airborne allergens particles measured. If the display indicates a moder-  
ate(yellow light) or high(red) level, the air cleaner will automatically turn on for  
30 minutes. At the end of 30 minutes, the sensor will resample the air (blinking  
green light). If the level of allergen particles detected by the sensor is less  
than the sensitivity setting you selected, the air cleaner will remain off, and the  
sensor will continue to constantly sample the air (blinking green light) until it  
detects that the particle level has exceeded the sensitivity setting you chose.  
TO RUN YOUR AIR (LEANER MANUALLY...  
1. Turn the sensitivity setting to the OFF/manual position.  
2. Choose one of the four fan speeds (sleep, low, medium, high).  
The air cleaner will run continuously until you shut it off.  
TO USE THE IONIZER...  
Push down the ionizer button. The indicator light will come on. The  
ionizer is now operating and will continue to operate whether  
the air cleaner is on or off.  
1. Place your air cleaner near the center of the room or in an area where the unit  
can operate without impediments to the airflow.  
2. Turn your air cleaner so that the Allergysmart detector can freely sample air (do  
not put the detector in a corner or otherwise impede air flow to the detector).  
3. Experiment with the location and sensitivity and fan speed settings on your unit.  
If you feel that your home’s air continues to contain allergen particles after  
running the unit at a low fan speed (sleep, low or medium) or at a lower  
sensitivity setting (average or extra), try increasing the fan speed to medium  
or high and/or increasing the sensitivity setting to extra or super. You can  
also try repositioning the unit in your room. Remember that the higher the  
sensitivity setting, with super being the highest, the lower the particle count  
required to cause the unit to turn on. If you feel that the unit is running  
too often, reduce the sensitivity setting (i.e. change the sensitivity setting  
from super to extra or average).  
 
If you feel that your home’s air needs constant cleaning, for instance during  
high pollen count days, you should manually operate the unit to run constantly  
(see page  
7
for instructions).  
4. Manually turn your air cleaner on if you see, smell or otherwise notice smoke  
in the air. The Allergysmart sensor does not detect smoke particles in the air  
due to their small size; however, the Allergysmart air cleaner does reduce  
smoke particles in the air with a True HEPA filter which will remove particles  
as small as .3 microns from the filtered air.  
5. The  
detector does not sense differences in types of allergy  
particles. If you are allergic to a particular type of allergen (such as pollens)  
you may want to adjust the sensitivity setting on your air cleaner because of  
changes in your home’s air.  
Caution: Individuals with acute respiratory problems should consult  
with their physician regarding use of an air cleaner as part of a treatment  
program.  
In addition to the  
Allergen Monitor, this Sunbeam  
air cleaner is equipped with the following features:  
TRUE HEPA FILTER  
Certified to capture 99.97% of all contaminants .3 microns or larger.  
CHARCOAL PRE-FILTER  
Reduces odors and extends the HEPA filter life.  
FILTER CHECK REMINDER LIGHTS  
Reminds you to check to see if your filter needs replacement.  
IONIZER  
An added stage of filtration to further clean the room. The ionizer negatively  
charges small particles not captured by the HEPA filter as they leave the air  
cleaner. These tiny charged negative particles will combine with other larger  
positively charged particles that can then be filtered out of the air through the  
air cleaner.  
 
CLEANING CAPACITY  
Your air cleaner has the capacity to clean the air in a 10’ x 12’ room every 5  
(model 2541) or 8 (model 2540) minutes on the high fan speed setting. Your  
air cleaner has a total of four fan speed settings, including an extra quiet sleep  
setting. Adjust fan settings as needed. The sleep setting will be the quietest  
setting but will also be the lowest performing in terms of the capacity of air  
cleaned.  
CHECKING THE FILTER  
ALWAYS UNPLUG THE UNIT BEFORE CHECKING THE FILTER.  
The check filter light indicates when it’s time to check your HEPA or charcoal  
filter to see if it needs replacement. If the light is:  
Blinking  
Check the charcoal filter for possible replacement (usually  
3
months after  
initial usage). Check the appearance of the filter to see if there is a visible  
amount of dust or lint on the filter. If so, you will need to replace the charcoal  
filter with replacement model #6620 for the model 2540 air cleaner, or #6622  
for the model 2541 air cleaner. See instructions below for replacing the  
filter. After you have checked or replaced the filter, make sure to press  
the RESET button.  
I
In use  
Time to change  
New  
In use  
Solid  
Check the HEPA filter for possible replacement (usually a minimum of lyear  
after the initial usage). If the filter appears brown in color, it is time to replace  
the filter. Use replacement filter model # 6619 for model 2540 air cleaner  
and #6621 for model 2541 air cleaner. See instructions below for replacing  
the filter. After you have checked or replaced the filter, make sure to press  
the RESET button.  
 
CHANGING THEFILTER  
1. Always unplug the unit prior to  
replacing the filter.  
2 . To remove the filter, turn the unit  
upside down and unscrew the  
knob at the base of the air cleaner.  
3 . Remove the old filter and replace  
with a new filter.  
4 . Replace base of unit and screw  
knob back in place.  
5 . Both the HEPA and charcoal filters  
can be replaced at your local retailer  
or ordered by mail.  
NEVER ATTEMPT TO SERVICE OR  
DISASSEMBLE THE UNIT YOURSELF  
(other than replacing the filter).  
Always unplug the unit before cleaning and when not in use.  
2. Outside surfaces intake or vents can be cleaned with a soft cloth.  
3. Do not submerge in water, or allow water to come in contact  
with the air cleaner.  
 
Sunbeam Products, Inc. warrants to the original purchaser, for a period of two years  
from date of purchase, this product shall be free of mechanical and electrical defects  
in material and workmanship subject to the limitations and exclusions set forth below.  
This warranty does not cover normal wear of parts or damage resulting rom any of the  
following: negligent use or misuse of the product, use on improper voltage or current,  
use contrary to the operating instructions or disassembly, repair or alteration by any  
person other than an authorized service center. Our obligation hereunder is limited to  
repair or replacement, at manufacturer’s option, of this product during the warranty  
period, provided that the product(s) purchased along with the model number and orig-  
inal dated proof of purchase, are sent postage pre-paid directly to:  
Sunbeam Appliance Service Station  
117 Central Industrial Row  
Purvis, MS 39475  
Answers to questions regarding this warranty or your nearest U.S.A. authorized  
service location may be obtained by calling toll-free l-800-597-5978 or by writing to  
Sunbeam-Consumer Affairs at PO. Box 948389. Maitland, Florida 32794-8389.  
00 NOT RETURN THIS PRODUCT TO THE PLACE OF PURCHASE; DOING SO MAY  
DELAY THE PROCESSING OF YOUR WARRANTY CLAIM.  
DISCLAIMER  
Product repair or replacement as provided under this warranty is your exclusive  
remedy. SUNBEAM PRODUCTS, INC. SHALL NOT BE LIABLE FOR ANY INCIDENTAL  
OR CONSEQUENTIAL DAMAGES FOR BREACH OF ANY EXPRESS OR IMPLIED  
WARRANTY ON THIS PRODUCT OR ANY PART THEREOF. EXCEPT TO THE EXTENT  
PROHIBITED BY APPLICABLE LAW, SUNBEAM PRODUCTS, INC. DISCLAIMS ANY  
IMPLIED WARRANTY OR CONDITION OF MERCHANTABILITY OR FITNESS FOR  
A
PARTICULAR PURPOSE OF THIS PRODUCT OR ANY PART THEREOF. Some states do  
not allow the exclusion or limitation of incidental or consequential damages, or allow  
limitations on how long an implied warranty lasts, so the above limitations or exclu-  
sions may not apply to you. This warranty gives you specific legal rights, and you  
may also have other rights, which vary from state to state.  
is a trademark of Sunbeam Corporation or its affiliated companies.  
Sunbeam@ is a registered trademark of Sunbeam Corporation or its affiliated  
companies. 01997 Sunbeam Corporation or its affiliated companies. All rights  
reserved. Distributed by Sunbeam Products, Inc., Delray Beach, Florida 33445.  
This product may be covered by U.S. Patent Numbers 5,001,463 and 5,646,597,  
and additional U.S. and/or foreign patents.  
PN 69400-000-000  
 
Mail Order Corm  
In the U.S., to order the following parts by credit card, please call:  
Sunbeam Products, Inc. at I-800-597-5978, or mail a check with this mail-  
order form to: Sunbeam Products, Inc., Consumer Affairs Department PO Box  
948389, Department PT., Maitland, FL 32794-8389  
Total  
Model No.  
Description  
Price Each  
6619  
Small HEPA Filter  
(For Model 2540)  
6620  
6621  
6622  
Small Charcoal pre-filter  
(For Model 2540)  
Large HEPA Filter  
(For Model 2541)  
Large  
Charcoal  
pre-filter  
$l4.99  
(For Model 2541)  
Shipping/Handling  
Total amount  
enclosed  
All taxes included in price.  
Mail check or money order  
(made payable to Sunbeam Products, Inc.) to:  
Sunbeam Products, Inc.  
Consumer Affairs Department  
PO Box 948389  
Please allow 4-6 weeks for delivery  
Maitland, FL 32794-8389  
City  
State  
Zip  
 

Sharp PDAs Smartphones El 6850 User Manual
Sony Camera Accessories GPS CS1KASP User Manual
Sony DVD Player RMT D165P User Manual
Sony Ericsson Bluetooth Headset HBH 608 User Manual
Sony Laptop VPCW222AX WI User Manual
Sony Video Game Console SCPH 70001 User Manual
Star Micronics Printer NB24 10 15 User Manual
Stiga Lawn Mower 12 5286 19 User Manual
Sunbeam Espresso Maker EM0180 User Manual
Suzuki Automobile 99011 66J22 03E User Manual