Planning Information
Integrated Model 700BR
Refrigerator Drawers
Seamless molding
Removable crisper
cover
Location of serial
number
Electronic digital
control panel
Model 700BR
Magnetic drawer
gaskets
Upper refrigerator
storage drawer
Front venting with
removable kickplate
Lower refrigerator
storage drawer
These appliances are Star-K certified from the
factory to meet strict religious regulations in
conjunction with specific instructions found on
star-k.org. No extra wiring harness is required.
The Sub-Zero Model 700BR integrated
design accepts custom wood or stainless
steel drawer panels. Stainless steel
panels and handles are available as sales
accessories in three finishes—classic,
platinum and carbon.
One of the more popular models of the Integrated
line, this handy two drawer refrigeration system is a
must for large and small homes alike. It is a perfect
illustration of the concept of a refrigeration system
where you can place units where they make the most
sense. They can stand alone or work together with
other Sub-Zero models to satisfy anyone’s needs.
Many homeowners are using them to supplement the
main Built-In unit that is installed in the home. With a
temperature range of 34˚F (1˚C) to 45˚F (7˚C), they are
perfect for beverages and vegetables in the island
application.
Dimensions in parentheses are in
millimeters unless otherwise specified.
1
11/06
Planning Information
Integrated Model 700BR
S P E C I F I C A T I O N S
Model 700BR
Drawer Refrigerator Unit
27" (686)
Overall Width
Overall Height
341/2" (876)
24" (610)
Overall Depth
M O D E L
Refrigerator Capacity
Minimum Height (levelers in)
Drawer Clearance
5.3 cu ft (150 L)
34" (864)
Drawer Refrigerator Unit
700BR
191/2" (495)
PA N E L O P T I O N S
Electrical Requirements
Annual Energy Usage
(based on 9.06 cents per kilowatt hour)
Energy Star Qualified
115 V AC, 60 Hz, 15 amp circuit
337 kWh / $31
Integrated (custom panels)
Classic Stainless Steel Finish
Platinum Stainless Steel Finish
Carbon Stainless Steel Finish
Stainless steel drawer front panels are
/S
/P
/B
Shipping Weight
190 lbs (86 kg)
Special Note
Drawer panels and handles are
ordered and shipped as sales accessories
and include tubular handles.
available in three stainless steel finishes
Specifications are subject to change without notice.
A C C E S S O R I E S
Drawer front panels with tubular
handles in classic, platinum and
carbon stainless steel
Tubular handles in classic,
platinum and carbon stainless
steel and polished chrome
Dozen egg container with lid
Drawer crisper cover with lid
Dual installation heater kit
Accessories are available through your
Sub-Zero dealer. To obtain local dealer
information, visit the Locator section of
our website, subzero.com.
Dimensions in parentheses are in
millimeters unless otherwise specified.
3
Planning Information
Integrated Model 700BR
I N S TA L L A T I O N S P E C I F I C A T I O N S
TOP VIEW
*PLACEMENT OF THE
1
ANTI-TIP
BRACKET*
1
1 /2"
13 /2"
ANTI-TIP BRACKET
(38)
(343)
SHOULD BE 24" (610)
FROM THE FRONT OF THE
UNIT WITHOUT PANELS
TO THE BACK OF THE
ANTI-TIP BRACKET.
25"
(635)
27"
25"
(686)
(635)
1
34 /2
"
(876)
NOTE: ANTI-TIP BRACKET MUST BE INSTALLED TO
PREVENT UNIT FROM TIPPING FORWARD
ANTI-TIP
BRACKET
FRONT VIEW
SIDE VIEW
LOCATE ELECTRICAL WITHIN
SHADED AREA – ORIENT GROUND
PRONG TO RIGHT AS SHOWN
ANTI-TIP
BRACKET
1
4 /2"
(114)
13" (330)
1
(6)
/4"
1
2 /2" (64)
1
15 /2" (394)
D I M E N S I O N S
Finished Rough Opening Width
Finished Rough Opening Height
Finished Rough Opening Depth
Location of Electrical
27" (686)
341/2" (876)
25" (635)*
Within shaded area
*The depth of the Model 700BR is 24" (610) from the front of the unit to its back. Your design
may necessitate moving the unit back, or cabinets forward to achieve a flush fit. This will require
a minimum rough opening depth of 25" (635).
See Installation Instructions shipped with unit for detailed specifications.
Dimensions in parentheses are in
millimeters unless otherwise specified.
4
Planning Information
Integrated Model 700BR
I N S TA L L A T I O N N O T E S
Refer to the illustrations and specifications
for overall dimensions, finished rough opening
dimensions and installation specifics.
Two Integrated units may be installed next to
one another. Refer to page 10 for additional
information.
IMPORTANT NOTE: The depth of Model 700BR
is 24" (610) from the front of the unit to its
back. Your design may necessitate moving the
unit back, or cabinets forward to achieve a
flush fit. This will require a minimum rough
opening depth of 25" (635). Refer to the instal-
lation illustration on page 4.
A 115 volt, 6OHz, 15 amp circuit breaker and
electrical supply are required. A separate circuit,
servicing only this appliance is necessary.
All Integrated models are equipped with a
power supply cord with a 3-prong grounding
plug, which must be plugged into a mating
3-prong grounding type wall receptacle. The
electrical outlet must be placed so the ground-
ing prong is to the right of the thinner blades.
The outlet must be flush with the back wall.
Locate electrical within the shaded area shown
in the installation illustration on page 4.
The anti-tip bracket must be installed to
prevent the unit from tipping forward.
Integrated units are compatible with virtually
any style of cabinetry. They can be used with
framed as well as frameless cabinets.
Do not use an extension cord or two prong
adapter. Electrical ground is required on this
appliance. Do not under any circumstances
remove the power supply cord ground prong.
The weight of each drawer panel cannot
exceed 12 lbs (5 kg). Drawer panels must be a
minimum of 5/8" (16) thick.
For the bottom drawer, the maximum panel
height is 1611/16" (424). You must keep a
minimum space of 4" (102) clear below the
bottom edge of the lower drawer panel, so the
unit can be properly vented. In addition, any
decorative base molding must be removable for
possible servicing and cleaning of the
condenser.
You must follow all National Electrical Code
regulations. In addition, be aware of local codes
and ordinances when installing your service.
The Integrated Refrigeration Installation
Instructions packed with the appliance will give
you step-by-step procedures for making sure
the unit is installed properly.
We recommend using D-style handles, which
should be located on the top, center area of the
drawer panel.
Dimensions in parentheses are in
millimeters unless otherwise specified.
5
Planning Information
Integrated Model 700BR
C A B I N E T R Y A P P L I C A T I O N S
Integrated refrigeration is compatible with virtually any
style and look of cabinetry. The models can be used with
framed as well as frameless cabinets. Because of the
precise application and the look you may want to achieve,
there are important questions you need to answer before
ordering panels for the drawers. As you look at styles of
cabinets, keep some important facts in mind:
IMPORTANT NOTE: The depth of each Integrated unit is
24" (610) from the front of the unit to its back. You must
allow for the thickness of the panel you are applying when
planning for the finished rough opening depth if you want
the front panel to be flush with surrounding cabinetry. You
may have to move the unit back into drywall or bring the
cabinets forward to achieve a flush fit.
Weight Limitations – The weight of each drawer panel
cannot exceed 12 lbs (5 kg).
Panel Thickness – Drawer panels must be a minimum of
5/8" (16) thick.
The toe kick clearance can vary with the height of the
lower drawer panel; the maximum panel height is 1611/16"
(424). You must keep a minimum space of 4" (102) clear
below the bottom edge of the lower drawer panel so the
unit can be properly vented.
IMPORTANT NOTE: The inside edges of the rough
opening, as well as the sides and a portion of the backside
of the decorative panels will need to be finished, as they
will be exposed when the drawers are open.
We recommend using D-style handles. Locate handles in
the top center area of the drawer panels.
Dimensions in parentheses are in
millimeters unless otherwise specified.
6
Planning Information
Integrated Model 700BR
F R A M E D C A B I N E T R Y A P P L I C AT I O N S
Framed cabinetry applications present you with different
questions to address. The illustrations on this page show
common applications of framed cabinetry. These are not
meant to be the only alternatives, but are suggestions
from designers around the country.
F R A M E D C A B I N E T R Y
IMPORTANT NOTE: The depth of each Integrated unit is
24" (610) from the front of the unit to its back. You must
allow for the thickness of the panel you are applying when
planning for the finished rough opening depth if you want
the front panel to be flush with surrounding cabinetry. You
may have to move the unit back into drywall or bring the
cabinets forward to achieve a flush fit. Refer to the
illustrations.
24
SUB-ZERO
UNIT
(610)
TO WALL
CABINET
FRAME
CABINET
DOOR
PANEL
1
/8" (3)
REVEAL
Illustrations on the following pages give dimensions for an
Integrated drawer unit installed within a framed cabinetry
beaded inset application. Review the illustrations, giving
particular attention to the overall panel specifications.
27
(686)
Traditional Frame – full overlay (top view).
24
SUB-ZERO
UNIT
(610)
TO WALL
CABINET
FRAME
CABINET
DOOR
PANEL
1
/8" (3)
REVEAL
27
(686)
Traditional Frame – standard overlay
(top view).
24
SUB-ZERO
UNIT
(610)
TO WALL
CABINET
FRAME
CABINET
DOOR
PANEL
1
/8" (3)
REVEAL
27
(686)
Traditional Frame – 3/8" (10) offset
(top view).
Dimensions in parentheses are in
millimeters unless otherwise specified.
7
Planning Information
Integrated Model 700BR
F R A M E D C A B I N E T R Y
–
B E A D E D I N S E T A P P L I C AT I O N
The illustration shows an Integrated drawer unit
installed within a framed cabinetry beaded inset
application.
24"
(610)
TO WALL
SUB-ZERO
UNIT
CABINET DOOR
IMPORTANT NOTE: Dimensions are based on a 1/8" (3)
reveal. A reveal of up to 1/4" (6) is possible, but panel
dimensions need to be adjusted accordingly.
PANEL
27"
A
A
TOP VIEW
(686)
A) ALL REVEALS ARE 1/8" (3)
B) DRAWER RAILS ARE ATTACHED TO DRAWER FRONTS
C) BOTTOM RAIL MUST BE REMOVABLE
*DIMENSIONS MAY VARY
SHADED AREA
INDICATES STATIONARY
STYLES AND RAILS
3
26 /4 (679)
"
PANEL WIDTH
A
B
9
13 /16"
(345)
1
34 /2"
A
A
B
(876)
*
1
15 /16"
(383)
"
1
1 /2
(38)
C
4"*
27"
4" (102)
(102)
(686)
1
(38)
1
(38)
1 /2
"
1 /2
"
24"
(610)
FRONT VIEW
SIDE VIEW
Installation of an Integrated drawer unit
within framed cabinetry.
*Dimensions may vary.
Dimensions in parentheses are in
millimeters unless otherwise specified.
8
Planning Information
Integrated Model 700BR
F R A M E L E S S C A B I N E T R Y A P P L I C AT I O N S
The illustration below shows a hypothetical installation of
an Integrated drawer unit within frameless cabinetry.
Review the illustration, giving particular attention to the
overall panel specifications.
IMPORTANT NOTE: Dimensions are based on a 1/8" (3)
reveal. A reveal of up to 1/4" (6) is possible, but panel
dimensions need to be adjusted accordingly.
F R A M E L E S S C A B I N E T R Y
3
24"
26 /4"* (679)
(610)
PANEL WIDTH
A
9
13 /16"
(345)
A
1
34 /2"
(876)
*
11
16 /16"*
(424)
4"*
(102)
27"
(686)
SIDE VIEW
TOE KICK
FINISHED OPENING
1
A) ALL REVEALS ARE /8" (3)
*DIMENSIONS MAY VARY
Installation of an Integrated drawer unit
within frameless cabinetry.
*Dimensions may vary.
Dimensions in parentheses are in
9
millimeters unless otherwise specified.
Planning Information
Integrated Model 700BR
CABINETS
25
(635)
I N S TA L L AT I O N O P T I O N S
27
(686)
The illustrations on this page show some typical
installations and their dimension considerations.
The depth dimension in the illustrations may vary
depending on cabinet styles, treatment of counter-
tops or other design options.
TOP VIEW
Installation without side panels.
IMPORTANT NOTE: The depth of each Integrated
unit is 24" (610) from the front of the unit to its
back. Your design may necessitate moving the unit
back, or cabinets forward to achieve a flush fit. This
will require a minimum rough opening depth of 25"
(635). Refer to the illustrations.
CABINETS
25
(635)
27
(686)
5
MINIMUM /8" (16) SIDE PANELS
D U A L I N S TA L L AT I O N S
If two or more Integrated models are installed side
by side where there is 2" (51) or less of space
between the units, a heater kit is recommended—
BBDUAL for two drawer units installed side by side
or a drawer unit and a tall unit installed side by
side. This optional component is available through
your Sub-Zero dealer. To obtain local dealer informa-
tion, visit the Locator section of our website,
subzero.com.
Installation with side panels.
CABINETS
25
(635)
54
(1372)
TOP VIEW
Installation of two units side by side.
CABINETS
25
(635)
27
(686)
5
MINIMUM /8" (16) SIDE PANELS
Installation at end of run.
Dimensions in parentheses are in
millimeters unless otherwise specified.
10
Planning Information
Integrated Model 700BR
T O E K I C K C L E A R A N C E
The toe kick clearance can vary with the height of the
lower drawer panel; the maximum panel height is 1611/16"
(424).
IMPORTANT NOTE: You must keep a minimum space of
4" (102) clear below the bottom edge of the lower drawer
panel so the unit can be properly vented. In addition, any
decorative base molding must be removable for possible
servicing and cleaning of the condenser.
The illustration below shows the area below the lower
drawer where the operating mechanical equipment of the
Integrated unit is housed.
IMPORTANT NOTE: The depth of each Integrated unit is
24" (610) from the front of the unit to its back. Your
design may necessitate moving the unit back, or cabinets
forward to achieve a flush fit. This will require a minimum
rough opening depth of 25" (635). Refer to the illustration.
T O E K I C K A R E A D E T A I L
10196
(268)
PANEL
1
2
(13)
11
16
16
(424)
PANEL
11
9
16
(246)
10
(254)
OPTIONAL
BASE MOLDING MUST
BE REMOVABLE
4
(102)
25
TO WALL
(635)
285 TO 4
FLOOR
(67)
(102)
Dimensions in parentheses are in
millimeters unless otherwise specified.
11
|