Sub Zero Refrigerator 700BR User Manual

Planning Information  
Integrated Model 700BR  
Refrigerator Drawers  
Seamless molding  
Removable crisper  
cover  
Location of serial  
number  
Electronic digital  
control panel  
Model 700BR  
Magnetic drawer  
gaskets  
Upper refrigerator  
storage drawer  
Front venting with  
removable kickplate  
Lower refrigerator  
storage drawer  
These appliances are Star-K certified from the  
factory to meet strict religious regulations in  
conjunction with specific instructions found on  
star-k.org. No extra wiring harness is required.  
The Sub-Zero Model 700BR integrated  
design accepts custom wood or stainless  
steel drawer panels. Stainless steel  
panels and handles are available as sales  
accessories in three finishes—classic,  
platinum and carbon.  
One of the more popular models of the Integrated  
line, this handy two drawer refrigeration system is a  
must for large and small homes alike. It is a perfect  
illustration of the concept of a refrigeration system  
where you can place units where they make the most  
sense. They can stand alone or work together with  
other Sub-Zero models to satisfy anyone’s needs.  
Many homeowners are using them to supplement the  
main Built-In unit that is installed in the home. With a  
temperature range of 34˚F (1˚C) to 45˚F (7˚C), they are  
perfect for beverages and vegetables in the island  
application.  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
1
11/06  
 
Planning Information  
Integrated Model 700BR  
S P E C I F I C A T I O N S  
Model 700BR  
Drawer Refrigerator Unit  
27" (686)  
Overall Width  
Overall Height  
341/2" (876)  
24" (610)  
Overall Depth  
M O D E L  
Refrigerator Capacity  
Minimum Height (levelers in)  
Drawer Clearance  
5.3 cu ft (150 L)  
34" (864)  
Drawer Refrigerator Unit  
700BR  
191/2" (495)  
PA N E L O P T I O N S  
Electrical Requirements  
Annual Energy Usage  
(based on 9.06 cents per kilowatt hour)  
Energy Star Qualified  
115 V AC, 60 Hz, 15 amp circuit  
337 kWh / $31  
Integrated (custom panels)  
Classic Stainless Steel Finish  
Platinum Stainless Steel Finish  
Carbon Stainless Steel Finish  
Stainless steel drawer front panels are  
/S  
/P  
/B  
Shipping Weight  
190 lbs (86 kg)  
Special Note  
Drawer panels and handles are  
ordered and shipped as sales accessories  
and include tubular handles.  
available in three stainless steel finishes  
Specifications are subject to change without notice.  
A C C E S S O R I E S  
Drawer front panels with tubular  
handles in classic, platinum and  
carbon stainless steel  
Tubular handles in classic,  
platinum and carbon stainless  
steel and polished chrome  
Dozen egg container with lid  
Drawer crisper cover with lid  
Dual installation heater kit  
Accessories are available through your  
Sub-Zero dealer. To obtain local dealer  
information, visit the Locator section of  
our website, subzero.com.  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
3
 
Planning Information  
Integrated Model 700BR  
I N S TA L L A T I O N S P E C I F I C A T I O N S  
TOP VIEW  
*PLACEMENT OF THE  
1
ANTI-TIP  
BRACKET*  
1
1 /2"  
13 /2"  
ANTI-TIP BRACKET  
(38)  
(343)  
SHOULD BE 24" (610)  
FROM THE FRONT OF THE  
UNIT WITHOUT PANELS  
TO THE BACK OF THE  
ANTI-TIP BRACKET.  
25"  
(635)  
27"  
25"  
(686)  
(635)  
1
34 /2  
"
(876)  
NOTE: ANTI-TIP BRACKET MUST BE INSTALLED TO  
PREVENT UNIT FROM TIPPING FORWARD  
ANTI-TIP  
BRACKET  
FRONT VIEW  
SIDE VIEW  
LOCATE ELECTRICAL WITHIN  
SHADED AREA – ORIENT GROUND  
PRONG TO RIGHT AS SHOWN  
ANTI-TIP  
BRACKET  
1
4 /2"  
(114)  
13" (330)  
1
(6)  
/4"  
1
2 /2" (64)  
1
15 /2" (394)  
D I M E N S I O N S  
Finished Rough Opening Width  
Finished Rough Opening Height  
Finished Rough Opening Depth  
Location of Electrical  
27" (686)  
341/2" (876)  
25" (635)*  
Within shaded area  
*The depth of the Model 700BR is 24" (610) from the front of the unit to its back. Your design  
may necessitate moving the unit back, or cabinets forward to achieve a flush fit. This will require  
a minimum rough opening depth of 25" (635).  
See Installation Instructions shipped with unit for detailed specifications.  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
4
 
Planning Information  
Integrated Model 700BR  
I N S TA L L A T I O N N O T E S  
Refer to the illustrations and specifications  
for overall dimensions, finished rough opening  
dimensions and installation specifics.  
Two Integrated units may be installed next to  
one another. Refer to page 10 for additional  
information.  
IMPORTANT NOTE: The depth of Model 700BR  
is 24" (610) from the front of the unit to its  
back. Your design may necessitate moving the  
unit back, or cabinets forward to achieve a  
flush fit. This will require a minimum rough  
opening depth of 25" (635). Refer to the instal-  
lation illustration on page 4.  
A 115 volt, 6OHz, 15 amp circuit breaker and  
electrical supply are required. A separate circuit,  
servicing only this appliance is necessary.  
All Integrated models are equipped with a  
power supply cord with a 3-prong grounding  
plug, which must be plugged into a mating  
3-prong grounding type wall receptacle. The  
electrical outlet must be placed so the ground-  
ing prong is to the right of the thinner blades.  
The outlet must be flush with the back wall.  
Locate electrical within the shaded area shown  
in the installation illustration on page 4.  
The anti-tip bracket must be installed to  
prevent the unit from tipping forward.  
Integrated units are compatible with virtually  
any style of cabinetry. They can be used with  
framed as well as frameless cabinets.  
Do not use an extension cord or two prong  
adapter. Electrical ground is required on this  
appliance. Do not under any circumstances  
remove the power supply cord ground prong.  
The weight of each drawer panel cannot  
exceed 12 lbs (5 kg). Drawer panels must be a  
minimum of 5/8" (16) thick.  
For the bottom drawer, the maximum panel  
height is 1611/16" (424). You must keep a  
minimum space of 4" (102) clear below the  
bottom edge of the lower drawer panel, so the  
unit can be properly vented. In addition, any  
decorative base molding must be removable for  
possible servicing and cleaning of the  
condenser.  
You must follow all National Electrical Code  
regulations. In addition, be aware of local codes  
and ordinances when installing your service.  
The Integrated Refrigeration Installation  
Instructions packed with the appliance will give  
you step-by-step procedures for making sure  
the unit is installed properly.  
We recommend using D-style handles, which  
should be located on the top, center area of the  
drawer panel.  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
5
 
Planning Information  
Integrated Model 700BR  
C A B I N E T R Y A P P L I C A T I O N S  
Integrated refrigeration is compatible with virtually any  
style and look of cabinetry. The models can be used with  
framed as well as frameless cabinets. Because of the  
precise application and the look you may want to achieve,  
there are important questions you need to answer before  
ordering panels for the drawers. As you look at styles of  
cabinets, keep some important facts in mind:  
IMPORTANT NOTE: The depth of each Integrated unit is  
24" (610) from the front of the unit to its back. You must  
allow for the thickness of the panel you are applying when  
planning for the finished rough opening depth if you want  
the front panel to be flush with surrounding cabinetry. You  
may have to move the unit back into drywall or bring the  
cabinets forward to achieve a flush fit.  
Weight Limitations – The weight of each drawer panel  
cannot exceed 12 lbs (5 kg).  
Panel Thickness – Drawer panels must be a minimum of  
5/8" (16) thick.  
The toe kick clearance can vary with the height of the  
lower drawer panel; the maximum panel height is 1611/16"  
(424). You must keep a minimum space of 4" (102) clear  
below the bottom edge of the lower drawer panel so the  
unit can be properly vented.  
IMPORTANT NOTE: The inside edges of the rough  
opening, as well as the sides and a portion of the backside  
of the decorative panels will need to be finished, as they  
will be exposed when the drawers are open.  
We recommend using D-style handles. Locate handles in  
the top center area of the drawer panels.  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
6
 
Planning Information  
Integrated Model 700BR  
F R A M E D C A B I N E T R Y A P P L I C AT I O N S  
Framed cabinetry applications present you with different  
questions to address. The illustrations on this page show  
common applications of framed cabinetry. These are not  
meant to be the only alternatives, but are suggestions  
from designers around the country.  
F R A M E D C A B I N E T R Y  
IMPORTANT NOTE: The depth of each Integrated unit is  
24" (610) from the front of the unit to its back. You must  
allow for the thickness of the panel you are applying when  
planning for the finished rough opening depth if you want  
the front panel to be flush with surrounding cabinetry. You  
may have to move the unit back into drywall or bring the  
cabinets forward to achieve a flush fit. Refer to the  
illustrations.  
24  
SUB-ZERO  
UNIT  
(610)  
TO WALL  
CABINET  
FRAME  
CABINET  
DOOR  
PANEL  
1
/8" (3)  
REVEAL  
Illustrations on the following pages give dimensions for an  
Integrated drawer unit installed within a framed cabinetry  
beaded inset application. Review the illustrations, giving  
particular attention to the overall panel specifications.  
27  
(686)  
Traditional Frame – full overlay (top view).  
24  
SUB-ZERO  
UNIT  
(610)  
TO WALL  
CABINET  
FRAME  
CABINET  
DOOR  
PANEL  
1
/8" (3)  
REVEAL  
27  
(686)  
Traditional Frame – standard overlay  
(top view).  
24  
SUB-ZERO  
UNIT  
(610)  
TO WALL  
CABINET  
FRAME  
CABINET  
DOOR  
PANEL  
1
/8" (3)  
REVEAL  
27  
(686)  
Traditional Frame – 3/8" (10) offset  
(top view).  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
7
 
Planning Information  
Integrated Model 700BR  
F R A M E D C A B I N E T R Y  
B E A D E D I N S E T A P P L I C AT I O N  
The illustration shows an Integrated drawer unit  
installed within a framed cabinetry beaded inset  
application.  
24"  
(610)  
TO WALL  
SUB-ZERO  
UNIT  
CABINET DOOR  
IMPORTANT NOTE: Dimensions are based on a 1/8" (3)  
reveal. A reveal of up to 1/4" (6) is possible, but panel  
dimensions need to be adjusted accordingly.  
PANEL  
27"  
A
A
TOP VIEW  
(686)  
A) ALL REVEALS ARE 1/8" (3)  
B) DRAWER RAILS ARE ATTACHED TO DRAWER FRONTS  
C) BOTTOM RAIL MUST BE REMOVABLE  
*DIMENSIONS MAY VARY  
SHADED AREA  
INDICATES STATIONARY  
STYLES AND RAILS  
3
26 /4 (679)  
"
PANEL WIDTH  
A
B
9
13 /16"  
(345)  
1
34 /2"  
A
A
B
(876)  
*
1
15 /16"  
(383)  
"
1
1 /2  
(38)  
C
4"*  
27"  
4" (102)  
(102)  
(686)  
1
(38)  
1
(38)  
1 /2  
"
1 /2  
"
24"  
(610)  
FRONT VIEW  
SIDE VIEW  
Installation of an Integrated drawer unit  
within framed cabinetry.  
*Dimensions may vary.  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
8
 
Planning Information  
Integrated Model 700BR  
F R A M E L E S S C A B I N E T R Y A P P L I C AT I O N S  
The illustration below shows a hypothetical installation of  
an Integrated drawer unit within frameless cabinetry.  
Review the illustration, giving particular attention to the  
overall panel specifications.  
IMPORTANT NOTE: Dimensions are based on a 1/8" (3)  
reveal. A reveal of up to 1/4" (6) is possible, but panel  
dimensions need to be adjusted accordingly.  
F R A M E L E S S C A B I N E T R Y  
3
24"  
26 /4"* (679)  
(610)  
PANEL WIDTH  
A
9
13 /16"  
(345)  
A
1
34 /2"  
(876)  
*
11  
16 /16"*  
(424)  
4"*  
(102)  
27"  
(686)  
SIDE VIEW  
TOE KICK  
FINISHED OPENING  
1
A) ALL REVEALS ARE /8" (3)  
*DIMENSIONS MAY VARY  
Installation of an Integrated drawer unit  
within frameless cabinetry.  
*Dimensions may vary.  
Dimensions in parentheses are in  
9
millimeters unless otherwise specified.  
 
Planning Information  
Integrated Model 700BR  
CABINETS  
25  
(635)  
I N S TA L L AT I O N O P T I O N S  
27  
(686)  
The illustrations on this page show some typical  
installations and their dimension considerations.  
The depth dimension in the illustrations may vary  
depending on cabinet styles, treatment of counter-  
tops or other design options.  
TOP VIEW  
Installation without side panels.  
IMPORTANT NOTE: The depth of each Integrated  
unit is 24" (610) from the front of the unit to its  
back. Your design may necessitate moving the unit  
back, or cabinets forward to achieve a flush fit. This  
will require a minimum rough opening depth of 25"  
(635). Refer to the illustrations.  
CABINETS  
25  
(635)  
27  
(686)  
5
MINIMUM /8" (16) SIDE PANELS  
D U A L I N S TA L L AT I O N S  
If two or more Integrated models are installed side  
by side where there is 2" (51) or less of space  
between the units, a heater kit is recommended—  
BBDUAL for two drawer units installed side by side  
or a drawer unit and a tall unit installed side by  
side. This optional component is available through  
your Sub-Zero dealer. To obtain local dealer informa-  
tion, visit the Locator section of our website,  
subzero.com.  
Installation with side panels.  
CABINETS  
25  
(635)  
54  
(1372)  
TOP VIEW  
Installation of two units side by side.  
CABINETS  
25  
(635)  
27  
(686)  
5
MINIMUM /8" (16) SIDE PANELS  
Installation at end of run.  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
10  
 
Planning Information  
Integrated Model 700BR  
T O E K I C K C L E A R A N C E  
The toe kick clearance can vary with the height of the  
lower drawer panel; the maximum panel height is 1611/16"  
(424).  
IMPORTANT NOTE: You must keep a minimum space of  
4" (102) clear below the bottom edge of the lower drawer  
panel so the unit can be properly vented. In addition, any  
decorative base molding must be removable for possible  
servicing and cleaning of the condenser.  
The illustration below shows the area below the lower  
drawer where the operating mechanical equipment of the  
Integrated unit is housed.  
IMPORTANT NOTE: The depth of each Integrated unit is  
24" (610) from the front of the unit to its back. Your  
design may necessitate moving the unit back, or cabinets  
forward to achieve a flush fit. This will require a minimum  
rough opening depth of 25" (635). Refer to the illustration.  
T O E K I C K A R E A D E T A I L  
10196  
(268)  
PANEL  
1
2
(13)  
11  
16  
16  
(424)  
PANEL  
11  
9
16  
(246)  
10  
(254)  
OPTIONAL  
BASE MOLDING MUST  
BE REMOVABLE  
4
(102)  
25  
TO WALL  
(635)  
285 TO 4  
FLOOR  
(67)  
(102)  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
11  
 

Sonance Speaker System VP67 LCR User Manual
Sony Camcorder XR550E User Manual
Sony Computer Monitor CPD L133 User Manual
Sony Home Theater System DAV DZ531W User Manual
Sony Speaker System SRS TP1 User Manual
SoundCraft Music Mixer MPM 12 2 User Manual
Star Manufacturing Food Warmer Lighted User Manual
Sterling Power Products Battery Charger 1210CE User Manual
SV Sound Speaker PB12 NSD 2 User Manual
Swann Home Security System SW216 2DS User Manual