Any other
battery bank
BATTERY CHARGER
S
STERLING QUICKCHECK LIST
Check these functions against out competitors
O
4 STEP CURVES FOR BATTERY CHARGERS
P
PRO - DIGITAL only
ADJUSTAABLE TIMME DEPENNDING ON
FOR 244 VOLTS
BATTERY BBANK SIZE
Example, a boat could be moored all year and never leave the pontoon, or a stand by generator with the
charger on all the time. In these cases the de-sulphation cycle would only happen once and the batteries
would eventually sulphate causing premature destruction. However the Sterling software has a 7 day
timer which in the event of inactivity will automatically run a de-sulphation cycle keeping your plates
clean.
X 2
Blue is a performance feature and Red a safety feature
C
H
A
R
G
E
R
%
C
U
R
R
E
15
EXTRA CHHARGE FOOR COVENNTIONAL
OR TRACTTION BATTEERIES AT 1144.8 VOLTS
Digital software control
3 isolated outputs
Automatic 110/230 volt selector
Power pack mode
Multiple input frequency from 40-400 hz
Thermostatically controlled fan cooling
4 step constant current charging curves
High ambient temperature rated
3 Battery type charging curve selector
Automatic battery bank size and state sensing
Automatic High charger time calculated every time
Automatic 7 day de - sulphation cycle
3 stage R.F.I .filter
Battery temperature sensing and compensation
3 battery temperature sensors
Independent unlimited high battery temp trip circuit
High battery voltage trip
High battery temperature trip
High heat sink temperature trip
Auto power reduction in event of high temperature
7 led output display information panel
24 kt gold plated output terminal post
Negative fused externally (A.B.Y.C. Requirement)
Reverse polarity protected
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
3
14.5
CHARGGER VOOLTS 14.4 V
GEL/SSEALEEDD BATTEERIES
ENGINE START
BATTERY
1
V
100
50
0
3 stage R.F.I filter:
DOMESTIC SYSTEM
14
FLOATT 13.5 V
In order to meet C.E. requirements for Radio Frequency Interference a three-stage filter is used to ensure
that not only is the standard reached but also that we fall well above the standard legally required.
Battery temperature sensing and compensation:
O
13.5
ENSURE ALL NEGS ARE COMMON
2
2
L 13
The Sterling Digital comes complete with a battery temperature sensor, which is automatically set to one
of the temperature compensation set by your battery type selector switch.
3 battery temperature sensors: The larger battery charger range comes complete with 3 temperature
sensors, which monitor and display and react to the 3 different battery banks, including 3 high temp trips
Independent unlimited high battery temp trip circuit: This unit has a trip circuit which can be
connected to any trip device such as temperature trips or any trip which results in an open circuit. The
problem is that a charger could be attached to 10 batteries but only monitoring 3, however if you wish
you can put a standard temperature trip on every battery and link them together into a common trip
circuit, if any of these batteries exceed a pre determined value the charger will switch off.
High battery voltage trip:
Things do go wrong no matter how hard we try so in the event of the regulator control failing, then any
voltage above what the software is expecting will shut the battery charger down and display the fault.
High battery temperature trip:
It always amazes me how many companies sense battery temperature and compensate the charger
voltage against temperature, but in the extreme event of total battery failure and the battery is going to
boil the battery charger will not switch off the charger. The Sterling processor not only senses the
temperature but will shut down the charger in event of total failure and display the fault condition.
High heat sink temp trip:
In the event of extreme temperature or cooling fan failure the battery charger will switch off at 70 deg C
Auto Power reduction in event of high temperature.
Because it is best to get as much power as possible at high temperature, in extreme high temperature or
cooling fan failure, if the heat sink reaches 65 deg C then the output current of the unit will be
systematically reduced to prevent the high temperature trip being activated at 70 deg C, its better getting
something than nothing.
7 led output display information panel: High charger rate, timer activated, battery type (3 colours),
Float mode, high battery temp trip, over voltage trip,
24kt gold plated output terminal posts:
Over a period of time brass corrodes in salt air making poor connectors, we have all seen the green paste
that forms around battery terminals etc. All Sterling connection posts are solid brass and are 24kt gold
plated to eliminate this for life.
Sterling gold
fuse block
GMFB 4848
1
12.5
CHARGE CCURRENT
T
S
12
4
4
11.5
11
3
N
T
BATTERY TYPE
SELECTOR
SWITCHES
10.5
FULL CURRRENT AVAIILABLE ONN FFLOAT FOR
ON BOARDD SUPPLY IIN POWER PPACK MODE
#
TIME
#
STEP 1 = CCONSTANNTT CURRENTT CHARGE
STEP 3 = CONSTANT VOLTAGE AT 13.5 VOLTS STEP 4 = LOW VOLTAGE RESET TO STEP1
STEP 2 = ABBSORPPTION CCHARGGE AT 144.4/14.8 V
BATTERY TYPE
green/red/yellow
OVER VOLTS TRIP
red
BATTERY TYPE
SWITCH SETTINGS
HIGH CHARGER TEMP
yellow
NON SEALED
LEAD ACID OR
TRACTION
L.E.D. YELLOW
HIGH BATTERY TEMP
red
light
sequence
on start up
FIT BATTERY TEMPERATURE
THERMAL SENSOR TO ANY BATTERY
TERMINAL, THE RED AND BLACK
WIRES ON THE SENSOR ARE NOT
POLARITY AWARE, IE EITHER WIRE IN
EITHER SOCKET
CONSTANT CURRENT
orange
TIME CONTROL ON
yellow
GEL OR
SEALED
LEAD ACID
L.E.D.GREEN
Over load protected
Short circuit protected
Remote control socket
Sturdy construction
Small foot print, low profile
FLOAT/POWERPACK
green
A.G.M.
FUSED
COMMON NEGATIVE
L.E.D RED
Extra features offered with the remote optional , a optional
extra with the medium chargers and standard with the large
INSTALLATION OF STERLING BATTERY CHARGER
acid/traction batteries for standard marine use, as there ability to top up the liquid level
increases there charge rate and life expectancy and we strongly recommend you stay
away from gel or A.G.M.as there charge rate is very limited.
This charger has many new features including the ability to compute the battery size
and state, so it is no longer necessary to program that information into the unit (as per
the previous model).
Connect the cables as per the diagram, ensure that all terminals are used, ie in the event
of only one battery being charged, connect the surplus positive output to the other used
output, i.e. both outputs are on the same battery. This ensures correct regulation; failure
to do this would reduce the charging performance slightly.
Position the charger in a cool dry well ventilated space, ensuring a reasonable airflow
around the charger. Do not install in a cupboard or sealed compartment.
This unit is fitted with an automatic 110/230 volt crossover as such the following
voltage may be used (90-125 or 190-260 volts at any frequency (40-400 Hz))
Install as close to the batteries as possible, preferably within 2 metres of the batteries.
The further away from the batteries you have to put the unit, increase the cable
thickness to compensate for voltage drops in the line. The cable diameter should be
16mm squared for the 12v30a and the 24v 25a and 25mm squared for the 12v 40a and
12v 50 a.
Before switching on the charger it is important to set up the battery type, please choose
a battery type from above. The highest charge rate (and voltage) will be the open lead
acid (set to a 14.8 volts on high charger) then gel (set at 14 .4 volts) then advanced glass
matt (set at 14.1 volts). ( the agm and gel voltage tends to vary with company to
company, so check which voltage your batteries require )If the battery type requires to
be reprogrammed, then select the appropriate setting on the dip switch and ensure the
charger is switched off then on again for the settings to take effect (this is because the
internal software chip requires a re-boot to install the new settings). The settings have
not taken effect if the L.E.D has not changed to the correct colour. In the event of
different types of batteries then the lowest battery voltage type must be selected, never
charge a battery on a higher setting than it should, Sterling recommends open lead
What information the L.E.D. display is giving you
Negative Fused externally (A.B.Y.C requirement):
Because the largest market for our products is in the USA, it is important to conform to European and
USA standards. This is a requirement for the USAA.B.Y.C boat building code of practice, as a result
some electricians were receiving electric shocks because they thought they were on the D/C negative
system when they were on the 110V A/C system (guaranteed to waken you up first thing in the morning)
.as a result international regulation bodies are attempting to change the colour of the D/C negative
cables (which have been black) to yellow, this is already the case in the U.S.A. for A.B.Y.C. and is under
review in the U.K. The negative cable in the new digital range comes as yellow and a gold fuse is
supplied.
Remote switch on/off
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Manual power reduction selector
Auto memory power lock on setting
Delay start up to enable power setting change
2 line 16 bit L.C.D. display screen
High charge rate timer countdown
Auto cycle all information with manual screen lock
Displays all alarm functions
Reverse polarity protected:
Always connect the cables to the charger first then run them to the batteries, never
connect to the batteries and run to the charger.
The supplied fuse blocks offers a good reverse polarity protection system.
Overload protected:
As stated the unit cannot be overloaded.
Short circuit protected:
As stated the cant can be short-circuited with no adverse results.
Display, volts amps temperatures etc
Surface mounted or recessed box
Warning, the charger case is earthed as per international regulations, on most boats the
A/C earth is connected to the bonding system and then to the negative of the battery,
this means that the case could be negative. If you touch the positive battery cables to
the case then you can set up a dead short to the battery negative via the earth cable and
melt the earth cable, this could start a fire. To avoid this, ensure the battery connectors
on the output studs do not touch the charger case, use insulated output connectors, it is
also recommended by A.B.Y.C. regulations that all the charger outputs have a fuse
connected. We recommend the Sterling gold range GMFB 4848, which offers a 4-bank
fuse block, which can be fused from 20-80 amps.
Digital software control
There are 2 ways to control electronic processing, Analogue (hardware control) and Digital (soft Remote control socket:
ware control). Hardware control is where the voltage sensing and processing are all done via
transistors and electronic hardware. This is fine as long as the information to be processed is kept Sturdy construction:
simple. However an Advanced Regulator may look simple (and most of them are) but when all
The unit has the ability to be connected to a digital L.C.D. information and control panel.
The unit is made from extruded aluminium and extremely sturdy, with extra thick 2.4 mm printed circuit
the different battery types, bank sizes, and safety parameters are installed, the unit would become board.
almost impossible to make and set up. Sterling leads the field in this type of controller but has
found that when upgrading from our previous model, it required so many extra features to keep
up with new battery types and alternator types etc, which makes a hard ware version impossible
to make.
Small footprint:
A modern requirement even on the largest boats is the requirement for a small foot print size, check our
size out.
Battery type, (Tri colored ):this L.E.D. is a 3 coloured L.E.D. which means it has 2 colours inside it (red and green). Either colour is used
separately or when both are on they look yellow. It is very important to ensure that the L.E.D. colour displayed conforms to your battery
type, if you have a mixture of lead acid and gel then the setting must be for the gel (the worst case, i.e. the gel can only handle 14.4 volts
but the lead acid can go to 14.8. so it is important not to exceed 14.4). This L.E.D. should be set as per the dipswitch instructions above.
Over-volts Trip. (Red): this L.E.D. indicates that the charger has tripped out due to either the chargers own regulator has failed, or an
external source is over charging (such as a solar cell, or wind generator, or engine alternator) and the charger thinks it has failed.
High charger temp: This shows that the charger has tripped because the heat sink is to hot, check if the fans are working. The unit will
restart when the heat sink reduces in temp.
High Battery temp (Red): The charger has switched off because it has picked up a battery temperature in excess of 50 deg C, investigate
your batteries immediately, and check the water levels. There is a serious problem, do not restart the charger until a fault has been found.
On reset monitor the temperature either from the remote or by simply keeping an eye on the batteries for the first few days.
Constant current. ( Orange): (This L.E.D. can look red but is in fact orange) this shows the unit is on constant current mode on start up,
and should remain on until the high charge cycle is complete (between 1 - 8 hrs max).
Digital control (software): This uses computer lines of code, digitally burned into a memory
processor in the Advanced Regulator. This means that very complex information and
mathematical processes can be processed, which would be impossible for the hardware system to
do. It is the next generation of control and more and more you will see the term digital control
appearing on different products. Digital control offers so many extra features at no extra cost
(see below) and accuracy beyond the ability of the analogue version.
3 isolated outputs:
The charger has 3 outputs enabling 3 different battery banks to be monitored and charged at the
same time.
Automatic 110/230 volt selector:
The in built system enables the charger to be automatically used on a wide voltage range from
80-300 volts A/C. This covers all the possibilities encountered on any marine in the world.
Multiple input frequencies from 40-400 Hz:
Self-explanatory, the unit is able to work on all worldwide A/C input frequencies.
Thermostatically controlled fan cooling:
The digital software monitors the unit temperature and controls the fans; this reduces any
unnecessary fan noise from the charger and prolongs the fans life for many years.
High ambient temperature rated:
Many boat builders expect the chargers to work at full power continuously at 40 deg ambient,
few chargers in the world meet this specification - we do.
3 battery type charging curve selector:
There is more than one battery type; most chargers do not offer different programs for different
battery types. Failure to offer an option will result in either overcharging some battery types and
sulphating others. The Sterling offers charging curves for open lead acid batteries, traction
batteries, sealed batteries, gel batteries and A.G.M batteries.
Automatic battery bank size and state:
No need to program in the battery bank size as the digital software can work that out itself.
Automatic High Charge timer calculated every time:
Extra features when connected to the Digital remote control
Remote switch on/off:
Self-explanatory (I hope).
BATTERYTYPE
green/red/yellow
Manual power reduction selector:
Some marinas offer only limited shore power; as a result high power battery chargers will not work. It
therefore becomes necessary to reduce the out power of the charger to enable it to operate from the
shore power. This remote offers the ability to select 100%, 50% or 25% power to deal with the lowest
shore power supplies. Its best to have some power than none, this feature is also good if an onboard
generator is used, i.e. you may want say a 100 amp charger for the onboard generator to charge the
batteries fast but the local berth cannot support such a large charger. In this case the charger could be
reduced to 25 amps when returned to the marina berth.
OVER VOLTS TRIP
red
HIGH CHARGER TEMP
yellow
HIGH BATTERYTEMP
red
Auto memory power lock on setting:
If reduced power is selected the software remembers the setting so in the event of removing the shore
power the charger will start up on the reduced setting next time.
Delay start up to enable power setting change:
In the event of a boat entering a marina and only a low power supply is available, if the last time the
charger was used then the charger would start up on high power and trip the shore supply. To overcome
this problem when the charger is started, the software counts down 30 seconds before automatically
starting the charger on the last setting. This gives the operator ample time to reduce the power if
required on the remote control.
2 line 16 bit L.C.D. display screen:
As described above a large information screen is use which as an on/off switch for the background light.
Auto cycle all information with manual screen lock:
Due to the large amount of information being displayed, it is not possible to fit it all on the screen. As a
result the screen automatically scrolls through the screens. However you may wish to monitor one
screen in particular, in this case simply push the lock button to lock that screen on.
Impressive information displayed:
CONSTANT CURRENT
orange
Time Control ( yellow ): This L.E.D. comes on between 6 minutes (minimum) and about 1 hr max, this indicates that the chargers timer
has started and the count down will be displayed on the remote control (if used). This timer light will remain on with the above orange
L.E.D until the end of the high charge cycle, when they both will go off and the lower green will come on.
Float/Power pack (Green). This means its all over as far as the fast charging is concerned, however the unit is now in power pack mode,
and will remain at about 13.5 volts float and supply your system any power it required up to its maximum power.
TIME CONTROL ON
yellow
FLOAT/POWERPACK
green
Battery Charger
Controller
on/off
The remote control is optional
with this charger, the benifits
of which are explained on the other
page
alarm
100%
14.4 v timer
Power
40 a
134 min
The L.C.D. display and control gives the following information, charger amps, charger volts, time
remaining on equalizing charger, battery type selected, battery temperature, charger temperature, plus all
alarm and other control functions.
Surface mount or recess box:
The clever remote control box design means the box can either be surface mounted on a bulkhead or
Most chargers have a fixed high charger timer, which works regardless of battery size and state
or even load on the boat. The digital processor is able to discern the battery bank size, what state
it is in and even take into consideration the power used by the boat. It then calculates the ideal
equalizing charger time; this will be different every time and will be from 1-6 hrs
Automatic 7 day de-sulphation cycle:
The good thing about a constant current charger is that it de-sulphates the battery plates ensuring
maximum life from the batteries. However, this only works if the charger is switched on/off
regularly (i.e. every time you disconnect and reconnect the charger the plates are subjected to a
de-sulphation cycle). The problem is some boats or standby equipment may be rarely used, for
light
50%
Select
25%
High battery temp
1
2
3
4
High heat sink temp
hold
High battery volts
Low voltage
flush mounted.
Sterling power products
CE
Page 5
|