Sierra Monitor Corporation Stud Sensor PF5M User Manual

Digital Flow Sensor  
Instruction Manual  
PFM5  
Series  
URL http://www.smcworld.com  
Specifications are subject to change without prior notice and any obligation on the  
part of the manufacturer.  
The descriptions of products shown in this document may be used by the other  
companies as their trademarks.  
© 2006 SMC Corporation All Rights Reserved  
 
Safety Instructions  
The Digital Flow Sensor have in after referred to as flow sensor  
and this manual contain essential information for the protection  
of users and others from possible injury and property damage  
and to ensure correct handling.  
Please check that you fully understand the definition of the  
following messages (signs) before going on to read the text, and  
always follow the instructions.  
Do not operate in an environment of inflammable, explosive  
or corrosive gas.  
Fire or an explosion can result.  
This flow monitor is not an explosion proof type.  
To avoid fire and explosion, Do not use the product for  
flammable fluid.  
IMPORTANT MESSAGES  
Read this manual and follow its instructions. Signal words such  
as WARNING, CAUTION and NOTE, will be followed by  
important safety information that must be carefully reviewed.  
Indicates a potentially hazardous situation  
This flow sensor is designed for air. Only dry air, N2, CO2, Ar are  
applicable.  
Do not use this product near by a place where static  
electricity is a problem.  
Otherwise it can cause failure or malfunction of a system.  
which could result in death or serious injury  
if you do not follow instructions.  
Indicates a potentially hazardous situation  
which if not avoided, may result in minor  
injury or moderate injury.  
These instructions must be followed while in maintenance ;  
Turn off the power supply, stop the supplied air, exhaust the  
residual pressure and verify the release of air before  
performing maintenance.  
Gives you helpful information.  
Otherwise it can cause injury.  
To avoid electric shock, malfunction, and switch damage,  
Do not touch live terminal nor connector.  
Do not disassemble, modify (including change of printed  
circuit board) or repair.  
An injury or failure can result.  
Do not operate outside of the specification.  
Fire, malfunction or flow monitor damage can result.  
Please use it after confirming the specification.  
 
2
3
Safety Instructions (continued)  
NOTE  
Follow the instructions given below when handling the flow  
sensor. Otherwise, the flow sensor may be damaged or may  
fail, thereby resulting in malfunction.  
Perform proper functional checks and leak tests after  
maintenance.  
Stop operation when an abnormality is observed such that the flow  
sensor does not work properly or there is a leakage of fluid.  
• Make sure to use a sensor by the specified voltage.  
• Make sure to use specified measurement flow and operating pressure.  
Safety is not be assured due to unexpected malfunction.  
When leakage occurred from other parts except piping, the flow sensor  
might break.  
Cut off power supply and stop supplying pressure. Don’t apply pressure  
at leaking condition.  
• Confirm the pressure loss at the sensor according to the flow  
characteristic (Pressure loss) graph for designing piping.  
• Prepare maintenance space.  
• Do not drop or bump, or apply excess impact (490mm/s ).  
2
• Do not pull the lead wire forcefully, not lift the product by pulling the  
lead wire. (Tensile force 49N or less).  
• Mount a sensor by observing the proper tightening torque.  
• For piping of the flow sensor, hold the piping with spanner on the metal  
part of the piping (Piping attachment).  
• Install or connect the flow sensor so that the flow direction specified on  
the label matches with actual flow direction.  
• Pipe the flow sensor after eliminating dust in piping by air blow to avoid  
failure and malfunction.  
• Never mount a sensor in a place that will be used as a scaffold during  
piping.  
Precaution on Handling  
Use UL approved product for direct current power supply.  
1.Clamping voltage current circuit complies with UL508  
Circuit which power supply if insulation transducer satisfying  
following conditions  
Max. voltage (No load) : 30Vrms (42.4V peak) or less  
Max. current : (1) 8A or less (Including short circuit)  
(2) When limited by the circuit  
• Use dry air which complies with the quality grade of ISO 8573-1 1.1.2 to  
1.6.2 : 2001.  
• If the entering of foreign material to the fluid is possible, install and pipe  
the filter or the mist separator to the inlet to avoid failure and  
malfunction.  
• Avoid repeatedly bending or stretching the lead wire.  
• Wire correctly.  
• Do not wire while the power is supplied.  
• Do not wire in conjunction with power lines or high voltage lines.  
• Confirm proper insulation of wiring.  
protector (fuse etc.) with the ratings in the table  
below.  
Voltage without load (V peak)  
0 to 20 [V]  
Max. current rating (A)  
5.0  
Over 20 [V] up to 30 [V]  
100/peak voltage  
2.Circuit (of class 2) which is of 30Vrms (42.4V peak) or less with the  
power supply unit of class 2 complying with UL1310 or transducer of  
class 2 complying with UL1585.  
 
4
5
Safety Instructions (continued)  
Names and Functions of Individual Parts  
NOTE  
• Wire as short as possible to avoid the affect of noise and surge.  
• Never use in the presence of explosive gases.  
• Do not use in an area where magnetic field is generated to avoid  
malfunction of sensor.  
Flow display  
Power source display  
Flow adjustment valve  
Knurl  
• Do not operate where the flow sensor is exposed to water.  
• Do not use in an area containing oil or chemicals.  
• Do not apply heat cycle to the flow sensor.  
• Do not used in an area where surges are generated.  
• Sensors are not equipped with surge protection against lightening.  
• Do not use load generate surge voltage.  
Piping port  
Through hole  
IN  
Body  
• Avoid foreign material such as wiring chips in the product.  
• Avoid using sensors in an environment where the likelihood of  
splashing or spraying of water, chemicals, and oil to avoid failure and  
malfunction.  
Power source display (green) : Turns on when power is supplied.  
Flow display (green) : Flashing interval depends on the flow value.  
As flow increases, flash interval is shortened.  
The light turns to red when rated flow is exceeded.  
Body : Flow sensor itself.  
• Consider operating environment according to protection class.  
2
• Do not mount the flow sensor where vibration (98m/s or less) and  
2
impact (490m/s or less) do not exist to avoid failure and malfunction.  
• Operation under low temperature (5 or less) leads to cause damage  
or operation failure due to frozen moist in the fluid or air.  
Flow adjustment valve : Orifice mechanism to abjust the flow.  
Piping port : Connect port of piping.  
• Do not short circuit the load.  
Knurl : Used to fix the needle.  
• Supply power when there is no flow.  
Through hole : Used to mount the flow sensor on a DIN rail or a panel directly.  
• The flow sensor is compulsory turned off for 3s after power supplied.  
• Maintenance and inspection should be performed periodically.  
• Analogue output may fluctuate by 2 to 3% for 10 minutes after  
supplying power to the flow sensor.  
• Do not poke inside a piping port with a stick.  
• A flow rate of the flow sensor, which has a restrictor, may change if the  
needle turns due to vibration.  
• The accuracy may fluctuate by 2 to 3% if a customer removes or  
replaces piping by themselves.  
• When the product is fixed with a screw using the through hole, please  
tighten it with a 0.3Nm ± 0.05 or less of tightening torque. (Excessive  
tightening may break the product.)  
 
6
7
Model Indication Method  
5
- -  
-
PFM  
-
Type  
Model  
5
Contente  
Option2  
Refer to the following table.  
Separate type sensor part  
Rated flow range (flow range)  
Option1  
Model  
Contente  
Model  
Nil  
W
Contente  
Connecter lead wire is included (2m)  
Connecter lead wire is included (2m) + Rubber cover  
No option  
10  
25  
50  
11  
0.2 to 10(5) /min  
0.5 to 25(12.5) /min  
1 to 50(25) /min  
2 to 100(50) /min  
Z
Note 1) Value in ( ) is the flow rate  
when CO2 is used.  
Proofreading certificate  
Flow adjustment valve  
Model  
Contente  
Nil  
A
Without proofreading certificate  
With proofreading certificate Note 2)  
Model  
Contente  
Nil  
S
No valve  
Valve  
Note 2) Writen in Japanese and English together.  
Other language is available as special request.  
Thread type (Connect port)  
Operation manual  
Flow range  
Model  
Contente  
10 25 50 11  
Model  
Nil  
N
Contente  
01  
02  
Rc1/8  
Rc1/4  
NPT1/8  
NPT1/4  
G1/8  
With operation manual (Booklet:in Japanese and English)  
Without operation manual  
N01  
N02  
F01  
F02  
C4  
Output specification  
Model  
1
2
Contente  
Applicable model  
PFM30 series  
PFM31 series  
G1/4  
Analog (1 to 5V)  
Analog (4 to 20mA)  
4 (5/32")One-touch fitting  
6 One-touch fitting  
C6  
C8  
N7  
8 (5/16") One-touch fitting  
1/4 One-touch fitting  
Lead wire with a connector (2m) is attached to the product.  
It can be ordered with a part No. ZS-33-D, when another one is required.  
Piping inlet  
Contente  
Straight direction  
Back  
Option2  
Model  
Nil No option  
Model  
Nil  
L
Option parts  
Part number of optional part alone  
Applicable part number  
R
S
T
Bracket (Flow adjusting valve unnecessary, pipig on the rear surface)  
Bracket (With flow adjusting valve)  
Panel mount adapter (Flow adjusting valve unnecessary)  
ZS-33-M  
ZS-33-MS  
ZS-33-J  
PFM5  
-
-
/PFM5  
(S)- L-  
PFM5  
PFM5  
-
-
-
(L)-  
V
P
anel mount adapter (With flow adjusting valve)  
ZS-33-JS  
PFM5  
S- (L)-  
Note 3) When two or more options are necessary, please describe those alphabetically.  
 
8
9
Mounting and Installation  
Installation  
bracket mounting  
•Fasten the bracket mounting screws at a clamping torque of  
0.5 0.05N·m.  
How to mount  
Panel Mount mounting  
•Insert Panel Mount Adapter B supplied as an accessory into  
Section A of Panel Mount Adapter A.  
Attached tapping screw  
Push Panel Mount Adapter B from behind till the display is fixed  
onto the panel.  
The pin of Panel Mount Adapter B engages the notched part of  
Panel Adapter C to fix the display.  
•The sensor can be mounted on a panel with a thickness of 1 to  
3.2mm.  
•See the illustration below for panel cut dimensions.  
1
I N  
Section C  
Section A  
A
Insert  
0
+0.5  
24  
Attached tapping screw  
Without flow adjustment  
valve  
(using ZS-33-M)  
Panel Mount  
Adapter A  
Push  
Panel  
Panel Mount  
Adapter B  
Bracket  
Dimension A  
Adaptor model  
ZS-33-J  
+0.5  
With flow adjustment valve  
(using ZS-33-MS)  
54 0  
Without flow adjustment valve  
With flow adjustment valve  
+0.5  
74 0  
ZS-33-JS  
 
10  
11  
Mounting and Installation (continued)  
DIN rail mounting (using ZS-33-R)  
Piping  
•The tightening toque for DIN rail mounting screws and joint  
screws should be 0.4 0.05N·m.  
•Keep the tightening torque when piping for the female thread.  
•Refer to the following table for the appropriate torque values.  
Nominal size of Appropriate torque  
screws  
Rc1/8  
Rc1/4  
N·m  
7 to 9  
12 to 14  
Through hole  
Bracket  
•Hold the metal part with the  
spanner when piping.  
Joint screw  
DIN rail mounting  
bracket  
DIN rail mounting  
screw  
Note) Not applicable if the thread type is F02.  
•For one-touch fitting, insert  
the tube to the end so that  
it is not pulled off.  
•Insertion with excess force  
lead to cause breakage.  
•Ensure no leakage after piping.  
•Use this flow sensor within the specified  
operating pressure range and operating temperature range.  
•Withstand pressure are 1.0MPa.  
 
12  
13  
Mounting and Installation (continued)  
Output circuit  
Wiring  
Brown DC(+)  
Black OUT1  
Connection  
Make connection after turning the power off.  
Use a separate route when installing wire.  
Load  
DC24V  
Malfunction stemming from noise may occur if wire is installed in  
the same route as that of power or high-voltage cable.  
White Select response time  
Be sure to ground terminal FG when using a switching regulator  
obtained on the market. If analog output is performed connecting to a  
switching regulator obtained on the market, switching noise will be  
superimposed and product specification can no longer be met. This  
can be prevented by inserting a noise filter, such as a line noise filter  
and a ferrite element, between the switching regulator and the  
sensor, or by using a seriespower supply instead of a switching  
regulator.  
Blue DC(  
-)  
Analog output 1 to 5V  
Output inpedance 1k  
Analog output 4 to 20mA  
Load inpedance 50 to 600  
External input : No voltage input  
Reed switch or solid state switch input  
30ms or more  
Select response speed  
To reduce ripple by slowing the response speed when ripple of  
analog output is large due to the effect of pulsation.  
Connector  
Connector Connecting / Disconnecting  
When connecting the connector, insert it straight onto the pin holding  
the lever and connector body between fingers and lock the connector  
by pushing the lever claw into the square groove in the body of sensor  
How to select  
Connect input line(white) to GND. While connected, response  
.
When disconnecting the connector, push down the lever by thumb  
to disengage the lever claw from the square groove. Then pull the  
speed is 1.0s. (50ms when not input)  
connector straight out.  
Body of sensor  
Lever  
Lead wire connector  
Cover (Option:ZS-33-F)  
 
14  
15  
Error Indication  
Error indication function  
This function is to display error location and content when a  
problem or an error occurs.  
Error Name Error Display Error Content Troubleshooting  
Flow exceeds  
Apply flow within rated  
rated flow range. flow range.  
Flow  
error  
POWER  
FLOW  
Flow disply lamp is red.  
System error.  
Turn off the power  
Possible damage supply once, and then,  
of internal circuit. supply the power  
again. If error is not  
released by this, please  
contact SMC sales  
office.  
POWER  
FLOW  
System  
Erro  
Power supply disply  
lamp is red.  
If the above remedy can't recover the operation, the error needs to be  
investigated by SMC.  
 
16  

Snapper Blower SLB55150BV User Manual
Sony Car Satellite TV System STR DH720 User Manual
Sony MiniDisc Player MZ E310 User Manual
Sony Speaker System MHC RV600D User Manual
StarTechcom Computer Drive HSB110SATBK User Manual
Sterling Gas Heater GF 150 User Manual
Sunbeam Convection Oven BT7000 User Manual
SVA Flat Panel Television ED4228P User Manual
Sylvania Cordless Telephone ST88245 User Manual
Sylvania CRT Television C6432TD User Manual