English Français Español
PRECAUTIONS
SPECIFICATIONS
SERVICE
Scanning system
: NTSC standard 525 lines, 60 fields/sec.
The camera is a precision instrument. Handle it carefully and always
follow the safety precautions. If the camera requires service, never
try to repair it yourself or open the casing.
Important
Image sensor
: 1/4" interline transfer method CCD
Number of effective pixels : 768 (H) x 494 (V)
Horizontal resolution
: 540 TV lines, typical
• Be careful when opening holes for installing the unit. Work with the
power and video cables pulled out for easy installation.
INSTRUCTION MANUAL
VCC-9684VA
For servicing, maintenance, or repairs, consult your dealer or an
Authorized Sanyo Service Center.
Minimum illumination
(approx.)
: 0.5 lx (F0.95)
• Make sure to properly perform waterproofing for the ceiling or wall
where you are installing the unit.
Video output
: 1.0 V(p-p)/75 Ω, composite, BNC
UTP support (VA-10T: option board)
Color CCD Camera
• Make sure that the surface in the installation location has no
unevenness and is strong enough to bear the total weight of the unit.
Video S/N ratio
Vari-focal lens
Rotation range
: More than 48 dB (AGC off: More than 50 dB)
: f=2.8 - 8 mm, F0.95 - 1.7
About this manual
: (On the ceiling) Pan: 100 degrees
Tilt: 0 - 90 degrees
• Install this unit in an environment where the temperature range stays
between -10°C and +50°C/14°F and 122°F (no condensation allowed).
Before installing and using the camera, please read this manual carefully.
Be sure to keep it handy for later reference.
(On the wall)
Pan: 90 degrees
Tilt: 0 - 90 degrees
• As a precaution against static electricity damage, touch a nearby metal
object (door knob, etc.) to dissipate static electricity in your body before
touching this unit.
Backlight compensation
: OFF, Multi-spot metering (High/Normal), Center zone
metering
Ceiling Installed
Wall Installed
White balance
: ATW/Manual
Electronic shutter
Aperture compensation
Sync system
: 1/60, 1/100, 1/1000, 1/2000 sec.
: Sharp/Normal
■ In case of a problem
: Internal sync/Line-lock
■ Dimensions
Do not use the unit if smoke or a strange odor comes from the unit,
or if it seems not to function correctly. Turn off the power
immediately and disconnect the power cord, and then consult your
dealer or an Authorized Sanyo Service Center.
Operating Environment
: Temperature: –10°C – +50°C (14°F – 122°F)
Humidity: less than 90 % RH (no condensation)
φ
151 (6.0)
Power supply
: 24 V AC 10%, 60 Hz / 12 - 15 V DC
Power consumption
(approx.)
: 2.4 W
■ Do not open or modify
Weight (approx.)
Accessory
: 500 g (16 oz.)
: Screw ×1, Warranty ×1
Do not open the cabinet, as it may be dangerous and cause damage
to the unit. For repairs, consult your dealer or an Authorized Sanyo
Service Center.
Appearance and specifications are subject to change without prior notice
or obligations.
■ Do not put objects inside the unit
*1 Surface routing
Make sure that no metal objects or flammable substance get inside
the unit. If used with a foreign object inside, it could cause a fire, a
short-circuit or damage. Be careful to protect the unit from rain, sea
water, etc. If water or liquid gets inside the unit, turn off the power
immediately and disconnect the power cord, and then consult your
dealer or an Authorized Sanyo Service Center.
Cutout
Unit: mm (inch)
φ
100 (4.0)
Rib mark
Safety Guard
■ Be careful when handling the unit
To prevent damage, do not drop the unit or subject it to strong shock
or vibration.
THIS SYMBOL INDICATES THAT THERE ARE IMPORTANT
OPERATING AND MAINTENANCE INSTRUCTIONS IN THE
LITERATURE ACCOMPANYING THIS UNIT.
INSTALLING BASE PLATE AND CONNECTIONS
■ Do not install this unit close to magnetic fields
The magnetic fields may result in unstable operation.
WARNING:
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT
EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.
Open the base plate.
Ceiling Installed
Monitor Connection
■ Protect from humidity and dust
For the customers in Canada
This Class B digital apparatus complies with Canadian ICES-003.
Pour la clientèle canadienne
Cet appareil numerique de la Classe B est conforme à la norme
NMB-003 du Canada.
1
2
To prevent damage, do not install the unit where there is greasy
smoke or steam, where the humidity may get too high, or where
there is a lot of dust.
Cable type
RG-59U (3C-2V) 250 m (273 yds) max.
RG-6U (5C-2V) 500 m (547 yds) max.
Length
1
Push
■ Protect from high temperatures
RG-11U (7C-2V) 600 m (656 yds) max.
This installation should be made by a qualified service person and should
conform to all local codes.
Do not install close to stoves, or other heat sources, such as
spotlights, etc., or where it could be subject to direct sunlight, as this
could cause deformation, discoloration or other damages.
Point the arrow (↓) in the same
direction as the lens
orientation.
• When using an RG-59U (3C-2V) cable, do not let it
dangle in the air or attach it to piping.
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or more of the following
measures:
Be careful when installing close to the ceiling, in a kitchen or boiler
room, as the temperature may rise to high levels.
• If you use a cable other than the types above, the
image or sync signal will be attenuated and will not
be transmitted correctly.
(A)
(A)
• Length: 35 mm/1.4 in. or more
• Diameter: 3.5 to 5.0 mm/0.1 to 0.2 in.
• Height of screw head:
■ Cleaning
(A)
• Dirt can be removed from the cabinet by wiping it with a soft cloth.
To remove stains, wipe with a soft cloth moistened with a soft
detergent solution and wrung dry, then dry by wiping with a soft
cloth.
(A)
(A)
5 mm/0.2 in. or less (washer included)
Make sure to tighten the screws properly.
–
–
–
Reorient or relocate the receiving antenna.
Using screws of sizes other than specified may cause the unit to fall.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
• Do not use benzine, thinner or other chemical products on the
cabinet, as this may cause deformation and paint peeling. Before
using a chemical cloth, make sure to read all accompanying
instructions. Make sure that no plastic or rubber material comes
into contact with the cabinet for a long period of time, as this may
cause damage or paint peeling.
Power Supply Connection
b With AC 24 V
b With DC 12 V
Wall Installed
–
Consult the dealer or an experienced radio/TV technician for help.
Check that +/- polarity is
correct.
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that
may cause undesired operation.
1
2
Place the base plate so that
the arrow points downward.
(RED)
(BLACK)
(WHITE)
~
Changes or modifications not expressly approved by Sanyo may void the user's
authority to operate this camera.
(RED)
+
–
~
2
(BLACK)
GND
(A)
For the connections, use cables thicker than 18 AWG.
(A)
(A)
1AC6P1P3265--
L5CJ2/US (1107KP-HS)
SANYO Electric Co., Ltd.
Printed in China
& Reverse side
(A)
|