COAXIAL REMOTE
CONTROLLER
User Manual
SPC-300
Safety information
CAUTION
RISK OF ELECTRIC SHOCK.
DO NOT OPEN
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR
BACK) NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.
This symbol indicates that dangerous voltage consisting a risk of
electric shock is present within this unit.
This exclamation point symbol is intended to alert the user to
the presence of important operating and maintenance (servicing)
instructions in the literature accompanying the appliance.
WARNING
•
To reduce the risk of fire or electric shock, do not expose this appliance to rain
or moisture.
WARNING
1. Be sure to use only the standard adapter that is specified in the specification sheet.
Using any other adapter could cause fire, electrical shock, or damage to the product.
2. Incorrectly connecting the power supply or replacing battery may cause
explosion, fire, electric shock, or damage to the product.
3. Do not connect multiple controllers to a single adapter. Exceeding the capacity
may cause abnormal heat generation or fire.
4. Securely plug the power cord into the power receptacle. Insecure connection
may cause fire.
5. When installing the controller, fasten it securely and firmly. The fall of controller
may cause personal injury.
6. Do not place conductive objects (e.g. screwdrivers, coins, metal parts, etc.) or
containers filled with water on top of the controller. Doing so may cause personal
injury due to fire, electric shock, or falling objects.
7. Do not install the unit in humid, dusty, or sooty locations. Doing so may cause fire
or electric shock.
8. If any unusual smells or smoke come from the unit, stop using the product. In
such case, immediately disconnect the power source and contact the service
center. Continued use in such a condition may cause fire or electric shock.
9. If this product fails to operate normally, contact the nearest service center. Never
disassemble or modify this product in any way. (SAMSUNG is not liable for
problems caused by unauthorized modifications or attempted repair.)
10. When cleaning, do not spray water directly onto parts of the product. Doing so
may cause fire or electric shock.
English 3
Safety information
CAUTION
1
2
3
4
5
6
7
1. Do not drop objects on the product or apply strong blows to it. Keep away from a
location subject to excessive vibration or magnetic interference.
2. Do not install in a location subject to high temperature (over 50°C), low
temperature (below -10°C), or high humidity. Doing so may cause fire or electric
shock.
3. If you want to relocate the already installed product, be sure to turn off the power
and then move or reinstall it.
4. Remove the power plug from the outlet when there is a lighting storm. Neglecting
to do so may cause fire or damage to the product.
8
9
5. Keep out of direct sunlight and heat radiation sources. It may cause fire.
6. Install it in a place with good ventilation.
7. Avoid aiming the controller directly towards extremely bright objects such as sun.
8. Apparatus shall not be exposed to dripping or splashing and no objects filled with
liquids, such as vases, shall be placed on the apparatus.
9. The Mains plug is used as a disconnect device and shall stay readily operable at
any time.
1
1
1
1
Correct Disposal of This Product (Waste Electrical & Electronic Equipment)
(Applicable in the European Union and other European countries with separate collection systems)
This marking on the product, accessories or literature indicates that the product and its electronic
accessories (e.g. charger, headset, USB cable) should not be disposed of with other household waste
at the end of their working life. To prevent possible harm to the environment or human health from
uncontrolled waste disposal, please separate these items from other types of waste and recycle them
responsibly to promote the sustainable reuse of material resources.
1
Household users should contact either the retailer where they purchased this product, or their local
government office, for details of where and how they can take these items for environmentally safe recycling.
Business users should contact their supplier and check the terms and conditions of the purchase contract.
This product and its electronic accessories should not be mixed with other commercial wastes for disposal.
Correct disposal of batteries in this product
(Applicable in the European Union and other European countries with separate battery return systems.)
This marking on the battery, manual or packaging indicates that the batteries in this product should not
be disposed of with other household waste at the end of their working life. Where marked, the chemical
symbols Hg, Cd or Pb indicate that the battery contains mercury, cadmium or lead above the reference
levels in EC Directive 2006/66. If batteries are not properly disposed of, these substances can cause harm
to human health or the environment.
To protect natural resources and to promote material reuse, please separate batteries from other types of
waste and recycle them through your local, free battery return system.
4 – COAXIAL REMOTE CONTROLLER
Important Safety Instructions
1. Read these instructions.
a
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the
manufacturer’s instructions.
g
8. Do not install near any heat sources such as radiators, heat registers, or other
apparatus (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A
polarized plug has two blades with one wider than the other. A grounding type
plug has two blades and a third grounding prong. The wide blade or the third
prong is provided for your safety. If the provided plug does not fit into your outlet,
consult an electrician for replacement of the obsolete outlet.
h
10. Protect the power cord from being walked on or pinched particularly at plugs,
convenience receptacles, and the point where they exit from the apparatus.
11. Only use attachments/accessories specified by the
manufacturer.
12. Use only with cart, stand, tripod, bracket, or table
specified by the manufacturer, or sold with the apparatus.
nt)
ms)
13. Unplug this apparatus when a card is used. Use caution
when moving the cart/ apparatus combination to avoid
injury from tip-over.
14. Refer all servicing to qualified service personnel. Servicing is required when the
apparatus has been damaged in any way, such as powersupply cord or plug is
damaged, liquid has been spilled or objects have fallen into the apparatus, the
apparatus has been exposed to rain or moisture, does not operate normally, or
has been dropped.
ing.
act.
osal.
ms.)
rm
f
English 5
Contents
I
Introduction
Introduction
6
7
T
a
Part names and functions
❖
Installation
Checking Installation Environment
11
11
Installation precautions
Connection & Control
To Control the camera coaxial communications
12
13
❖
❖
To control the camera using RS-485 device
via coaxial communications
To control the camera using RS-232 device
via coaxial communications
14
15
To control the camera using RS-485 signal output
To control the camera using RS-485 signal
output via RS-232 communications
16
17
Switch Setting Table
Specifications
Specifications
20
21
Dimensions
6 – COAXIAL REMOTE CONTROLLER
Introduction
INTRODUCTION
This remote controller can control A1 series cameras through A1 coaxial connection,
and can control COAXITRON supporting cameras through COAXITRON communication.
❖
Features
•
Long-distance remote control
Through RS-485 communication, remote control is possible up to 1.2
kilometers.
•
Easy Control
Easy and simple 5-way keys for controlling the camera.
❖
❖
List of controllable models
•
•
Capable of controlling A1 series camera products.
You can control cameras supporting COAXITRON.
What’s Included
COAXIAL REMOTE
CONTROLLER
User Manual
SPC-300
<Controller>
<User Guide>
English 7
Introduction
PART NAMES AND FUNCTIONS
❖ Front Panel
n
o
p
POWER
POWER
STATUS
s
t
ADDRESS
(X)100
OFF
CABLE
ON
(X)10
(X)1
COMPENSATION
q
r
S
L
❻
TERMINATION
PROTOCOL
REMOTE CONTROLLER SPC-300
❶
❷
❸
❹
STATUS LED
- Displays the status of the current operation.
POWER LED
- Switch to select the power source from DC 12 V or 4 AA batteries.
POWER Switch
- If you slide it to ON, the controller turns on.
CABLE COMPENSATION Switch
- For long distance coaxial communications, you can use this switch for amplifying
the control signal.
❼
❺
RS-485 TERMINATION & PROTOCOL Setting Switch
- You can select to set the RS-485 termination (left 2-pin piano switch).
- To set the RS-485 termination (left 2-pin piano switch), turn the switch ON.
N
ON
ON
1
2
1
2
3
4
5
6
7
8
TERMINATION
PROTOCOL
8 – COAXIAL REMOTE CONTROLLER
Introduction
-
For multi-protocol settings, you can set the protocol (right 8-pin piano switch),
baud rate, and communication mode of COAXIAL/COAXITRON/RS-485/RS-232.
ON
ON
1
2
1
2
3
4
5
6
7
8
TERMINATION
PROTOCOL
- Use pin 1,2,3 of the Protocol setting switch to select a protocol.
- The protocol switch pin 4 sets the protocol to COAXIAL or COAXITRON.
- Use pin 5,6 of the Protocol setting switch to select a baud rate.
s
t
- The protocol switch pin 7 sets the protocol to COAXIAL (BNC communication)
or RS-485 output.
- Use pin 8 of the Protocol setting switch to select RS-232 input.
❻
Address Switch
-
For RS-232 / RS-485 communications, you can use this switch to set the address.
ADDRESS
(X)100
(X)10
(X)1
- Set the address by using three switches shown above.
- From the left, the number is hundreds, tens and ones place, respectively.
The effective range of valid address is between 0 and 255 (1~255 for multi-
protocol).
g
❼
Menu Navigation Key
Use this to navigate through the menus.
For further details on ON/OFF setting of each switch for the applicable configuration,
refer to SPC-300 Connection and Control section.
NOTE
English 9
Introduction
❖
PART NAMES AND FUNCTIONS
❖ Rear Panel
❶
❷
❸
❹
- AA BATTERY
You can use 4 AA-sized batteries for the power.
- The average operation time is 20 hours based on the alkaline battery.
(If the battery is discharged, it can cause a distortion of the video signal, or
electric interference.)
Remove the battery if you do not use the controller for a longer period. Otherwise, it
may cause damage to the controller from a leak of the battery solution.
❺
NOTE
Take caution not to change the specified polarity.
Do not use a new battery with an old one.
For storing used batteries, keep out of reach of children. Wasted batteries are to be
collected separately.
10 – COAXIAL REMOTE CONTROLLER
Introduction
❖ Top
R E M O T E C O N T R O L L E R S C P - 3 0 0
P R O T O C O L
T E R M I N A T I O N
2
3 1
4
5
6
7
2 8
1
O N
O N
S
L
C O M P E N S A T I O N
C A B L E
O F F
( X ) 1
( X ) 1 0
( X ) 1 0 0
A D D R E S S
O N
O W E R
S T A T U S
P O W E R
RS-485
DC 12V
VIDEO
RS-232C
TX
RX
T IN
n
o
p
q
r
❶
❷
❸
❹
USB Port
- This terminal is used for updating the product’s firmware.
RS-232 Port (9-pin D SUB)
- Used to control remotely using RS-232 communication.
RS-485 Port (4-pin)
- Used to control remotely using RS-485 communication.
VIDEO IN/OUT Connector (BNC)
- VIDEO IN receives coaxial communication from cameras, and VIDEO OUT
outputs the video signal.
❺
DC12V Power Connector (2-PIN)
- Used for connecting DC12V power source.
English 11
Installation
CHECKING INSTALLATION ENVIRONMENT
T
K
•
•
Please check the following instructions before installation for your safety.
The way of connecting the main product with external devices (COAXIAL BNC)
is very important to build up a proper system.
•
Do not disassemble the unit; doing so could expose you to dangerous high
voltage points.
INSTALLATION PRECAUTIONS
•
Make sure you turn off the product before installation.
•
Do not put a strong force on or shake the product; otherwise it may cause
malfunction.
1
2
•
Keep the product away from areas of strong magnetic field or electric
interference, or wireless devices such as radio or TV set.
•
•
Keep clean the installation place during and after the installation.
An abnormal smells from the product is a sign of abnormal condition, which
may cause fire or electric shock. In this case, disconnect the product from
the main power immediately and contact the retailer for technical help from
authorized servicing.
3
4
•
•
Keep the product away from a wet floor, do not use an unearthed power
extension cable, worn-out power cord, neither forget earth-grounding.
Use a dry cloth only to dirt off the product. If the product is badly dirty, apply
neutral detergent on a cloth that is used to dirt off, and wipe it out with a dry
cloth.
•
Do not use volatile substances such as alcohol, benzene or thinner as these
may damage the finish.
❖
12 – COAXIAL REMOTE CONTROLLER
Connection & Control
TO CONTROL THE CAMERA USING CONTROL MENU
KEYS AND COAXIAL / COAXITRON OUTPUT
R E M O T E C O N T R O L L E R S C P - 3 0 0
P R O T O C O L
T E R M I N A T I O N
2
1 3
4
5
6
7
2
8
1
O N
O N
S
L
C O M P E N S A T I O N
C A B L E
O F F
X (
) 1
( X ) 1 0
( X ) 1 0 0
A D D R E S S
O N
W E R
S T A T U S
P O W E R
1. Connect the product to DC 12V power source or insert 4 AA-sized
batteries into the battery compartment.
(Power can be supplied via USB cable connection.)
2. Connect the VIDEO IN of the unit and VIDEO OUT of the AI Camera directly.
–
The A1 camera and SPC-300 should be directly connected to the VIDEO IN.
3. Connect VIDEO OUT of the main unit to a monitor’s video input terminal.
4. You can control camera menu after setting the switch as shown below:
PIN 4
ON
OFF
Output Selection
COAXITRON
A1 COAXIAL
ON
1
2
3
4
5
6
7
8
PROTOCOL
PIN 7
ON
OFF
Output Selection
COAXIAL OUT
RS-485 OUT
ON
1
2
3
4
5
6
7
8
PROTOCOL
–
–
Select the coaxial output by using the protocol switch pin 7.
The pin 7 coaxial / RS-485 has the output priority.
To select from COAXIAL or COAXITRON, use the pin 4.
❖
You can use the menu as following :
–
–
–
Press and hold [ENTER]: Moves to the main menu screen.
Press [ENTER] briefly: Used to confirm the current settings.
Four Direction Keys: Used to move the cursor up/down or left/right.
No address setting is required for connecting COAXIAL / COAXITRON camera and SCP-300.
If not in menu control, it operates ZOOM/FOCUS function for COAXIAL output. If not in
menu control, it operates PAN/TILT function for COAXITRON output.
For COAXIAL control, the camera should be set to SAMSUNG-E protocol.
When controlling COAXITRON menu while the menu is turned on, press and hold
ENTER key to exit the menu screen.
NOTE
English 13
Connection & Control
TO CONTROL THE CAMERA USING RS-485 INPUT
AND COAXIAL / COAXITRON OUTPUT
T
V
R E M O T E C O N T R O L L E R S C P - 3 0 0
P R O T O C O L
T E R M I N A T I O N
2
1 3
4
5
6
7
2
8
1
O N
O N
S
L
C O M P E N S A T I O N
C A B L E
O F F
1
( X ) 1 0
( X ) 1 0 0
A D D R E S S
O N
P O W E R
S T A T U S
P O W E R
1. Connect the product to DC 12V power source or insert 4 AA-sized
batteries into the battery compartment.
(Power can be supplied via USB cable connection.)
1
2. Connect the VIDEO IN of the unit and VIDEO OUT of the AI Camera
2
3
directly.
–
The A1 camera and SPC-300 should be directly connected to the VIDEO IN.
3. Connect VIDEO OUT of the main unit to a monitor’s video input terminal.
4. Connect TX(+/-) of RS-485 device to RX(+/-) of the main unit.
(For a full duplex system, connect RX(+/-) of RS-485 device to TX (+/-) of
main unit additionally.)
4
5
6
5. Use a combination of pin 1,2,3 of the Protocol setting switch to select a
protocol.
–
Refer to the switch configuration table. (See page 18)
6. Using RS-485 device, you can control the camera menu.
Each mentioned protocol may require updating the firmware from the website.
NOTE
By factory default, protocols of SAMSUNG-E, SAMSUNG-T and PELCO-D/P are
supported.
To support additional protocol, access the website to update the program.
RS-232 and RS-485 communications cannot be used simultaneously.
COAXIAL and COAXITRON cannot be used simultaneously.
N
RS-485 input and COAXITRON control supports SAMSUNG-E and SAMSUNG-T
protocols only, while COAXIAL control supports all protocols.
For COAXIAL control, the camera should be set to SAMSUNG-E protocol.
14 – COAXIAL REMOTE CONTROLLER
Connection & Control
TO CONTROL THE CAMERA USING RS-232 DEVICE
VIA COAXIAL COMMUNICATIONS
R E M O T E C O N T R O L L E R S C P - 3 0 0
P R O T O C O L
T E R M I N A T I O N
2
1 3
4
5
6
7
2
8
1
O N
O N
S
L
C O M P E N S A T I O N
C A B L E
O F F
( X ) 1
( X ) 1 0
( X ) 1 0 0
A D D R E S S
N O
W E R
S T A T U S
P O W E R
1. Connect the product to DC 12V power source or insert 4 AA-sized
batteries into the battery compartment.
(Power can be supplied via USB cable connection.)
2. Set the protocol switches 7 and 8 to ON.
3. Connect the VIDEO IN of the unit and VIDEO OUT of the AI Camera
directly.
–
For proper data communication, the unit and AI camera should be connected directly.
(If you connect a DVR or keyboard in the middle of the main unit and AI camera,
bidirectional communication will not be established.)
of
4. Connect VIDEO OUT of the main unit to a monitor’s video input terminal.
5. Connect the RS-232 device’s cable to the RS-232 port of the main unit.
6. Using RS-232 device, you can control the camera menu.
–
The RS-232 device is the same as RS-485 regarding the protocol setting, but
supports only the Samsung protocol.
–
For proper coaxial communication, AI camera should be set to Samsung protocol.
Refer to the switch settings. (See page 18)
RS-232 and RS-485 communications cannot be used for simultaneous input.
RS-232 device control supports SAMSUNG-E protocol only.
NOTE
English 15
Connection & Control
TO CONTROL THE CAMERA USING RS-485 OUTPUT
AND CONTROL MENU KEYS
T
O
R E M O T E C O N T R O L L E R S C P - 3 0 0
P R O T O C O L
T E R M I N A T I O N
2
1 3
4
5
6
7
2
8
1
O N
O N
S
L
C O M P E N S A T I O N
C A B L E
O F F
X ) 1
X ) 1 0
( X ) 1 0 0
A D D R E S S
O N
P O W E R
S T A T U S
P O W E R
1. Connect the product to DC 12V power source or insert 4 AA-sized
batteries into the battery compartment.
(Power can be supplied via USB cable connection.)
1
2. Connect the RX(+/-) of the unit to the RS-485 (+/-) port of the camera.
2
3
4
3. Match the camera’s address, baud rate, and protocol to the same to
those of the unit.
-
For address switch, refer to the page 8.
3. Now you can control the camera by using the menus.
You can use the menu as following :
5
6
❖
–
Press and hold [ENTER]: Moves to the main menu screen.
To exit the menu screen, press and hold the key again.
–
–
–
Press [ENTER] briefly: Used to confirm the current settings.
Four Direction Keys: Used to move the cursor up/down or left/right.
Control of pan/tilt/zoom using the buttons is not supported.
N
RS-232 and RS-485 communications cannot be used simultaneously.
5-direction key (control menu) only supports A1 camera’s menu control.
NOTE
16 – COAXIAL REMOTE CONTROLLER
Connection & Control
TO CONTROL THE CAMERA USING RS-485 SIGNAL
OUTPUT VIA RS-232 COMMUNICATIONS
R E M O T E C O N T R O L L E R S C P - 3 0 0
P R O T O C O L
T E R M I N A T I O N
2
1 3
4
5
6
7
2
8
1
O N
N
S
L
C O M P E N S A T I O N
C A B L E
O F F
X (
) 1
( X ) 1 0
( X ) 1 0 0
A D D R E S S
N O
W E R
S T A T U S
P O W E R
1. Connect the product to DC 12V power source or insert 4 AA-sized
batteries into the battery compartment.
(Power can be supplied via USB cable connection.)
2. Set the protocol switch 8 to ON.
3. Connect the RX(+/-) of the unit to the RS-485(+/-) port of the camera.
4. Match the camera’s address, baud rate, and protocol to the same to
those of the unit.
–
RS-232 device control supports SAMSUNG-E protocol only.
5. Connect the RS-232 device’s cable to the RS-232 port of the main unit.
6. Using RS-232 device, you can control the camera menu.
RS-232 and RS-485 communications cannot be used for simultaneous input.
For the switch settings, see the switch setting table. (See page 18)
Input of video signal is required to control RS-485.
NOTE
English 17
Connection & Control
SWITCH SETTING TABLE
❖
Use a combination of pin 1,2,3 of the Protocol setting switch to select a protocol.
ON
ON
1
2
1
2
3
4
5
6
7
8
TERMINATION
PROTOCOL
Protocol Setting Switch
Software
Type
(A, B, C, D)
(0 :r, 1 :q)
Protocol
HALF/FULL
PIN 1
PIN 2
PIN 3
0
1
0
1
0
1
0
0
1
0
1
0
1
0
1
0
0
1
1
0
0
1
0
0
0
0
0
0
1
1
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
SAMSUNG-E
SAMSUNG-E
SAMSUNG-T
SAMSUNG-T
PELCO-D
PELCO-D
PELCO-P
PANASONIC
PANASONIC
HONEYWELL
HONEYWELL
VICON
HALF
FULL
ALL
ALL
A
SIMPLEX
FULL
A
SIMPLEX
FULL
A
A
SIMPLEX
HALF
A
B
FULL
B
SIMPLEX
FULL
C
C
HALF
D
VICON
FULL
D
AD
SIMPLEX
FULL
D
AD
D
❖
Use pin 4, 7 and 8 of the Protocol setting switch to set the coaxial output.
PIN 4
ON
Output Selection
COAXITRON
A1 COAXIAL
ON
1
2
3
4
5
6
7
8
OFF
PROTOCOL
PIN 7
ON
Output Selection
COAXIAL OUT
RS-485 OUT
ON
1
2
3
4
5
6
7
8
OFF
PROTOCOL
PIN 8
ON
RS-232 input
RS-232 input
RS-232 No use
ON
1
2
3
4
5
6
7
8
OFF
PROTOCOL
Setting of the PIN 7 overrides that of PIN 4.
NOTE
18 – COAXIAL REMOTE CONTROLLER
Connection & Control
–
See the following table to set the baud rate.
ON
ON
1
2
1
2
3
4
5
6
7
8
TERMINATION
PROTOCOL
BAUD RATE
PIN 5
OFF
ON
PIN 6
OFF
OFF
ON
38400 BPS
19200 BPS
9600 BPS
4800 BPS
OFF
ON
ON
t.
English 19
Specifications
SPECIFICATIONS
Item
D
Description
COAXIAL / COAXITRON INTERFACE
Max. 500m (with 5C-2V cable)
D-SUB 9P
Communication Method
COAXIAL
Range
Connector Type
Port
1 Port
RS-232
4800/9600/19200/38400bps
(Only Samsung protocol supported)
BAUD RATE
Connector Type
4P Terminal Type
1 Port
RS-485
Port
BAUD RATE
4800 / 9600 / 19200 / 38400 bps
S/W PROGRAM UPLOAD
USB PORT(USB2.0)
Composite Video
1.0Vp-p, 75ohm,
VIDEO IN/OUT
Cable Compensation out
(Select:S/L)
A) SAMSUNG-E, SAMSUNG-T, PELCO-D/P
B) SAMSUNG-E, PANASONIC
Multi-protocol (Supports 4 programs)
Operating Temp.
C) SAMSUNG-E, HONEYWELL
D) SAMSUNG-E, VICON, AD
-10˚C ~ +50˚C
Less than 90%
DC12V 10%
150(W) X 36(H) X 102(D)
200 g
Environmental
Conditions
Humidity
POWER
DIMENSIONS (WxHxD)
WEIGHT
NET
20 – COAXIAL REMOTE CONTROLLER
Specifications
DIMENSIONS
Unit (mm)
English 21
SALES NETWORK
SAMSUNG TECHWIN CO., LTD.
Samsungtechwin R&D Center, 701, Sampyeong-dong, Bundang-gu, Seongnam-si, Gyeonggi-do, Korea, 463-400
TEL : +82-70-7147-8740~60, FAX : +82-31-8018-3745
SAMSUNG TECHWIN AMERICA Inc.
SAMSUNG TECHWIN EUROPE LTD.
1480 Charles Willard St, Carson, CA 90746, UNITED STATES
Tol Free : +1-877-213-1222, FAX : +1-310-632-2195
Samsung House, 1000 Hillswood Drive, Hillswood Business Park Chertsey,
Surrey, UNITED KINGDOM KT16 OPS
TEL : +44-1932-45-5300, FAX : +44-1932-45-5325
AB68-00857A
P/NO. : Z6806-1331-01A
|