PRODUCT MODEL NUMBERS  
OVERALL DIMENSIONS  
MHE14XM  
15"  
(38.1 cm)  
Electrical: A 120 Volt, 60 Hz, AC only, 15- or  
20-amp fused electrical supply (or circuit breaker)  
is required. (A time-delay fuse or circuit breaker is  
recommended.) It is recommended that a separate  
circuit serving only this appliance be provided.  
16¹⁄₄"  
(41.3 cm)  
CABINET OPENING DIMENSIONS  
VENTING REQUIREMENTS  
A
B
A 3¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular or 6" (15.2 cm) round vent should be used.  
The total length of the vent system including straight vent, elbow(s), transitions and wall  
or roof caps must not exceed the equivalent of 140 ft (42.7 m) for either type of vent.  
For best performance, use no more than three 90° elbows.  
To calculate the length of the system you need, add the equivalent length for each vent  
piece used in the system. See the following examples:  
30"  
(76.2 cm)  
min.  
A minimum 3(7.6 cm) clearance must exist between the top of the microwave oven  
and the rectangular to round transition piece so that the damper can fully open.  
A
B
C
12" (30.5 cm) min.  
14" (35.6 cm) max.  
66" (167.6 cm) min.  
D
E
F
G
A. Rectangular to round transition piece: 3¹⁄₄" x 10" to 6" = 5 ft  
(8.3 x 25.4 cm to 15.2 cm = 1.5 m)  
B. Roof cap: 3¹⁄₄" x 10" = 24 ft (8.3 x 25.4 cm = 7.3 m)  
C. 90° elbow: 3 " x 10" = 25 ft (8.3 x 25.4 cm = 7.6 m)  
D. 90° elbow: 6" = 10 ft (15.2 cm = 3 m)  
E. Wall cap: 3¹⁄₄" x 10" = 40 ft (8.3 x 25.4 cm = 12.2 m)  
F. 45° elbow: 6" = 5 ft (15.2 cm = 1.5 m)  
G. 90° flat elbow: 3¹⁄₄" x 10" = 10 ft (8.3 x 25.4 cm = 3 m)  
A. 2" x 4" wall stud  
B. Grounded 3 prong outlet  
6" (15.2 cm) vent system = 73 ft (22.2 m) total  
A
B
6 ft (1.8 m)  
3¹⁄₄" x 10" (8.3 x 25.4 cm) vent system = 73 ft (22.2 m) total  
A
B
6 ft (1.8 m)  
2 ft  
(0.6 m)  
2 ft  
(0.6 m)  
C
C
D
A. One 3¹⁄₄" x 10" (8.3 x 25.4 cm) 90° elbow = 25 ft (7.6 m)  
B. 1 wall cap = 40 ft (12.2 m)  
C. 2 ft (0.6 m) + 6 ft (1.8 m) straight = 8 ft (2.4 m)  
A. Two 90° elbows = 20 ft (6.1 m)  
B. 1 wall cap = 40 ft (12.2 m)  
C. 1 rectangular to round transition piece = 5 ft (1.5 m)  
D. 2 ft (0.6 m) + 6 ft (1.8 m) straight = 8 ft (2.4 m)  
Because Whirlpool Corporation policy includes a continuous commitment to improve  
our products, we reserve the right to change materials and specifications without notice.  
Dimensions are for planning purposes only. For complete details, see Installation  
Instructions packed with product. Specifications subject to change without notice.  
Ref. 8206200  
02-23-06  
 

QSC Audio Speaker AD S52T User Guide
Q See Webcam QT428 811 User Guide
Radica Games Games 75036 User Guide
Radio Shack Motorized Toy Car 60 4307 User Guide
Rival Slow Cooker Smart SetTM User Guide
Roberts Radio Portable Radio R9957 User Guide
Rover Lawn Mower Domestic Rotary Mower User Guide
Ryobi Trimmer 767rj User Guide
Samsung Computer Monitor T240 User Guide
Savin Printer 9940DPC User Guide