Electrical: To supply the required three- or four-  
wire, single-phase, 120/240-volt, 60-Hz, AC-only  
electrical supply (or three- or four-wire,  
120/208-volt electrical supply, if specified on the  
serial/rating plate) on a separate 30-amp circuit,  
fused on both sides of the line. A time-delay fuse  
or circuit breaker is recommended. Connect to an  
individual branch circuit. Do not have a fuse in the  
neutral or grounding circuit.  
Exhaust venting: Exhaust your dryer to the  
outside. 4" (10.2 cm) diameter heavy metal exhaust  
vent and clamps must be used. DURASAFE™  
venting products are recommended. For best drying  
performance, rigid metal vents are recommended.  
Flexible metal vents are acceptable only if accessible  
for cleaning. Do NOT use plastic or metal foil vent.  
Exhaust hood must be at least 12" (30.4 cm) from  
the ground or any object that may be in the path of  
the exhaust.  
15¹⁄₄"  
(57.8cm)  
43³⁄₈"  
(38.7 cm)  
43³⁄₈"  
(110cm)  
A. Small Opening  
Side-Swing Door  
(110cm)  
B. Large Opening  
Side-Swing Door  
*27³⁄₄"  
*26"  
(66cm)  
(70.5cm)  
29"  
29"  
(73A.7cm)  
(73.7cm)  
B
22³⁄₄"  
(57.8cm)  
C. Wide Opening  
Side-Swing Door  
43³⁄₈"  
43³⁄₈"  
(110cm)  
(110cm)  
13³⁄₄"  
D. Wide Opening  
(34.9cm)  
Hamper Door  
*27³⁄₄"  
*27³⁄₄"  
(70.5cm)  
(70.5cm)  
29"  
29"  
(73.7cm)  
(73.7cm)  
C
D
*Most installations require a minimum 5" (12.7 cm) clearance behind the dryer for exhaust  
vent with elbow.  
RECESSED AREA AND CLOSET INSTALLATION  
3"*  
For closet installation  
(7.6 cm)  
14" max.*  
(35.6cm)  
with a door, minimum  
ventilation openings in  
the top and bottom of  
the door are required.  
Louvered doors with  
equivalent air openings  
are acceptable.  
*
48 in. 2  
EXHAUST VENTING  
(310 cm2 )  
18"*  
(45.7 cm)  
*
24 in.2  
Box hood style  
3"*  
(155 cm2 )  
4"  
(7.6 cm)  
(10.2 cm)  
1"  
29"  
5"*  
(12.7 cm)  
1"  
1" 27³⁄₄"  
4"  
4"  
(2.5 cm)  
(73.7 cm)  
(2.5 cm)(2.5 cm)(70.5 cm)  
(10.2 cm)  
(10.2 cm)  
Louvered style  
B
C
A
A. Recessed area  
2.5"  
(6.4 cm)  
B. Side view - closet or confined area  
C. Closet door with vents  
*Required spacing  
Angled style  
Vent Length Chart  
NOTE: Side and bottom exhaust installations have  
a 90° turn inside the dryer. To determine maximum  
exhaust length, add one 90° turn to the chart.  
1. Select the route that will provide the straightest and most direct path outdoors. Plan the  
installation to use the fewest number of elbows and turns. When using elbows or making turns,  
allow as much room as possible. Bend vent gradually to avoid kinking. Use the fewest 90° turns  
possible.  
Vent Length Chart  
2. Determine vent length.  
Number of  
90turns  
or elbows  
Type of  
vent  
Box or  
Louvered  
hoods  
Angled  
hoods  
3. Determine the number of elbows you will need.  
IMPORTANT: Do not use vent runs longer than specified in the Vent Length Chart.  
0
1
2
3
4
Rigid metal  
Rigid metal  
Rigid metal  
Rigid metal  
Rigid metal  
64 ft (20 m)  
58 ft (17.7 m)  
48 ft (14.6 m)  
54 ft (16.5 m)  
44 ft (13.4 m) 38 ft (11.6 m)  
35 ft (10.7 m) 29 ft (8.8 m)  
27 ft (8.2 m)  
21 ft (6.4 m)  
Because Whirlpool Corporation policy includes a continuous commitment to improve  
our products, we reserve the right to change materials and specifications without notice.  
Dimensions are for planning purposes only. For complete details, see Installation  
Instructions packed with product. Specifications subject to change without notice.  
Ref. W10150612B  
03-11-09  
 

QSC Audio Portable Speaker ISIS Series User Guide
Q See Security Camera qr404 411 User Guide
Radio Shack Motorized Toy Car 60 4307 User Guide
Remington Hair Dryer DC 1875N User Guide
Rotel DVD Player RDV 1092 User Guide
Samsung CD Player MAX B550 User Guide
Samsung Printer ML 4050N User Guide
Samsung Refrigerator DA99 01278C User Guide
Sears Elliptical Trainer 83128742 User Guide
Sennheiser Headphones E 180 User Guide