Rheem Furnace 05EAUER User Guide

FORM NO. G11-449 REV. 6  
Supersedes Form No. G11-449 Rev. 5  
GAS FURNACES  
®
CRITERION II  
80.0-82.2% A.F.U.E.✝  
DOWNFLOW  
GAS FURNACES  
The Rheem® Criterion® II line of downflow gas furnaces is  
designed for installation in closets, alcoves, utility rooms, or  
attics. The design is certified by CSA.  
Features  
Patented heat exchanger, constructed of both stainless  
and aluminized steel for the maximum in corrosion  
resistance.  
Low profile “34 inch” [864 mm] design is lighter and easier  
to handle, and leaves room for optional equipment.  
Left or right side gas and electric inlet connections with  
quick, simple change.  
Direct Spark ignition models and integrated board with  
humidifier and electronic air cleaner hookups.  
Insulated blower compartment helps to reduce jacket loss  
and noise.  
Pre-paint galvanized steel cabinet.  
Molded permanent filter.  
RGLH- SERIES  
Grab-holes in doors to aid in easy door removal and  
replacement.  
Models with Input Rates from  
A variety of cooling coils and plenums designed to use with  
50,000 to 150,000 BTU/HR  
[15 to 44 kW]  
Rheem Criterion II gas furnaces are available as optional  
accessories.  
A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of  
Energy test procedures.  
ENER UIDE  
Annual Fuel Utilization Efficiency AFUE  
-
THIS MODEL  
80.0%  
MID  
78% 82%  
HIGH  
88%  
97%  
 
BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE  
FROM YOUR RETAILER.  
PHYSICAL DATA AND SPECIFICATIONS  
MODEL NUMBERS  
RGLH- SERIES  
05EAUER  
05NAUER  
07EAUER  
07NAUER  
07EAMGR  
07NAMGR  
10EAMER  
10NAMER  
10EBRJR  
10NBRJR  
12EARJR  
12NARJR  
15EARJR  
15NARJR  
50,000 [15]  
41,000 [12]  
45,000 [13]  
75,000 [22]  
60,000 [18]  
67,500 [19.8]  
75,000 [22]  
60,500 [18]  
67,500 [19.8]  
100,000 [29.3]  
80,000 [23]  
100,000 [29.3]  
81,000 [24]  
125,000 [36.6]  
99,000 [29]  
150,000 [44]  
120,000 [35]  
135,000 [39.6]  
Input–BTU/Hr [kW]  
Heating Capacity BTU/Hr [kW] ➀  
High Altitude Input [kW]  
90,000 [26.4]  
90,000 [26.4]  
112,500 [33]  
High Altitude Output  
Capacity [kW]  
36,500 [10.7]  
.10 [.025]  
53,500 [15.7]  
.12 [.029]  
54,000 [15.8]  
.12 [.029]  
72,000 [21.1]  
.15 [.037]  
72,500 [21.2]  
.15 [.037]  
89,000 [26.1]  
.20 [.05]  
107,500 [31.5]  
.20 [.05]  
Heat Ext. Static Pressure [kPa]  
11 x 6 = 10*AU  
[279 x 152]  
11 x 7 = 10*AM  
[279 x 178  
11 x 6  
[279 x 152]  
11 x 6  
[279 x 152]  
11 x 7  
[279 x 178]  
11 x 10  
[279 x 254]  
11 x 10  
[279 x 254]  
11 x 10  
[279 x 254]  
Blower (D x W) [mm]  
Motor H.P. [W]–Speeds [W]–  
PSC Type  
1/2-4-PSC  
[373]  
1/2-4-PSC  
[373]  
3/4-4-PSC  
[559]  
1/2-4-PSC  
[373]  
3/4-4-PSC  
[559]  
3/4-4-PSC  
[559]  
3/4-4-PSC  
[559]  
Motor Full Load Amps  
Heating Speed  
6.8  
7.1  
9.5  
7.1  
9.5  
9.5  
9.5  
MED-LOW  
HIGH  
MED-HIGH  
HIGH  
MED-LOW  
MED-HIGH  
MED-HIGH  
HIGH  
MED-LOW  
MED-HIGH  
MED-LOW  
MED-HIGH  
MED-LOW  
MED-HIGH  
Cooling Speed  
Cooling CFM @ .5" [kPa] E.S.P.  
(Nominal) [L/s]  
1200  
[566]  
1200  
[566]  
1600  
[755]  
1200  
[566]  
2000  
[944]  
2000  
[944]  
2000  
[944]  
Rated E.S.P. (In. W.C.) [kPa]  
.50 [.12]  
.50 [.12]  
.50 [.12]  
.50 [.12]  
.50 [.12]  
.50 [.12]  
.50 [.12]  
55-85 = 10*AU  
[30.6-47.2]  
45-75 = 10*AM  
[25-41.7]  
Temperature Rise Range °F  
[°C]  
25-55  
[13.9-30.6]  
40-70  
[22.2-38.9]  
25-55  
[13.9-30.6]  
40-70  
[22.2-38.9]  
40-70  
[22.2-38.9]  
50-80  
[27.8-44.4]  
Max. Outlet Air Temp. °F  
[°C]  
155  
[68.3]  
165  
[73.9]  
155  
[68.3]  
190  
[87.8]  
190  
[87.8]  
180  
[82.2]  
190  
[87.8]  
(1) 14 x 20  
[356 x 508]  
(2) 12 x 20  
[305 x 508]  
(2) 12 x 20  
[305 x 508]  
(2) 12 x 20  
[305 x 508]  
(2) 14 x 20  
[356 x 508]  
(2) 14 x 20  
[356 x 508]  
(2) 14 x 20  
[356 x 508]  
Standard Filter [mm]  
Approx. Shipping Weight (Lbs.)  
[kg]  
85  
[38.6]  
105  
[47.6]  
105  
[47.6]  
115  
[52.2]  
120  
[54.4]  
140  
[63.5]  
150  
[68.0]  
82.2%  
80.5%  
81.1%  
80.2%  
80%  
80%  
80%  
AFUE–Electric Ignition Models ➀  
California Seasonal Efficiency–  
Electric Ignition Nox Models  
75.9/76.2  
74.4/74.9  
75.1/75.5  
75.2/75.2  
74.7/74.7  
75.2/75.3  
76.0/75.9  
NOTES: All models are 115V, 60HZ, 1Ø  
. Gas connection size for all models is 1/2" N.P.T.  
In accordance with D.O.E. test procedures.  
See Conversion Kit Index Form No. 92-21519-52 for U.S. models and Form No. 92-21519-53 for Canadian models for high altitude derate.  
MODEL IDENTIFICATION—DOWNFLOW MODELS  
R
G
L
H
07E  
A
U
E
R
Rheem  
Gas  
Furnace  
Downflow Design  
Series  
Heating Input Designation  
Variations  
A = Std.  
Cabinet  
B = Wide  
Cabinet  
Blower  
Designation  
Heating & Cooling  
Designation  
S = 500-1200 CFM  
[236-566 L/s]  
E = 1100-1330 CFM  
[519-628 L/s]  
G = 1450-1750 CFM  
[684-826 L/s]  
Fuel Type  
R = Natural Gas,  
U.S. and  
Electric  
Ignition Model  
NO  
Input  
BTU/HR  
x
U = 11 x 6  
[279 x 152 mm]  
M = 11 x 7  
[279 x 178 mm]  
R = 11 x 10  
[279 x 254 mm]  
Canadian  
Standard  
Furnace  
05E  
07E  
10E  
12E  
15E  
05N  
07N  
10N  
12N  
15N  
50,000 [15 kW]  
75,000 [22 kW]  
100,000 [29 kW]  
125,000 [37 kW]  
150,000 [44 kW]  
J = 1800-2075 CFM  
[850-979 L/s]  
[
] Designates Metric Conversions  
Rheem Manufacturing Company  
3
 
DOWNFLOW DIMENSIONS  
TABLE 1. DIMENSIONS AND CLEARANCE TO COMBUSTIBLE MATERIAL (INCHES) [mm]  
REDUCED CLEARANCES (IN.) [mm]  
MODEL  
RGLH-  
SERIES  
A
B
C
D
E
LEFT  
SIDE  
RIGHT  
SIDE  
SHIP. WGTS.  
(LBS.) [kg]  
BACK  
TOP  
FRONT  
VENT  
05  
07  
14 [356]  
171/2 [445]  
171/2 [445]  
21 [533]  
241/2 [622]  
241/2 [622]  
1227/32 [326]  
1611/32 [415]  
1611/32 [415]  
1927/32 [504]  
2311/32 [593]  
2311/32 [593]  
103/8 [264]  
121/8 [308]  
121/8 [308]  
137/8 [352]  
155/8 [397]  
155/8 [397]  
131/8 [333]  
165/8 [422]  
165/8 [422]  
201/8 [511]  
235/8 [600]  
235/8 [600]  
0
0
0
0
0
0
0
0
0
0
0
0
1 [25]  
1 [25]  
1 [25]  
1 [25]  
1 [25]  
1 [25]  
3 [76]  
3 [76]  
3 [76]  
3 [76]  
3 [76]  
3 [76]  
85 [38.6]  
105 [47.6]  
115 [52.2]  
120 [54.4]  
140 [63.5]  
150 [68]  
4 ➁  
3 ➁  
3 ➁  
6 [152] ➂  
6 [152] ➂  
6 [152] ➂  
6 [152] ➂  
6 [152] ➂  
6 [152] ➂  
10 (A)  
10 (B)  
12  
0
0
0
15  
NOTES: May require a 3" [76 mm] to 4" [102 mm] or 3" [76 mm] to 5" [127 mm] adapter.  
May be 0" [0 mm] with type B vent.  
May be 1" [25 mm] with type B vent.  
Furnaces must be vented in accordance with ANSI Z21.47-1993 • CAN/CGA-2.3-M93 venting table guidelines, and in accordance with local codes.  
[
] Designates Metric Conversions  
4
Rheem Manufacturing Company  
 
BLOWER PERFORMANCE DATA—DOWNFLOW MODELS  
MODEL  
NUMBER  
RGLH-  
CFM [L/s] AIR DELIVERY  
BLOWER  
SIZE  
[mm]  
MOTOR  
H.P.  
[W]  
BLOWER  
SPEED  
EXTERNAL STATIC PRESSURE INCHES [kPa] WATER COLUMN  
.1 [.02]  
.2 [.05]  
.3 [.07]  
.4 [.10]  
.5 [.12]  
.6 [.15]  
.7 [.17]  
SERIES  
LOW  
735 [347]  
715 [337]  
1015 [479]  
1165 [550]  
1330 [628]  
690 [326]  
995 [470]  
1150 [543]  
1310 [618]  
660 [311]  
975 [460]  
1130 [533]  
1295 [611]  
635 [300]  
955 [451]  
1100 [519]  
1265 [597]  
605 [286]  
930 [439]  
1075 [507]  
1235 [583]  
575 [271]  
905 [427]  
1040 [491]  
1205 [569]  
05MAUER  
05EAUE  
05NAUER  
11 x 6  
[279 x 152]  
1/2  
[373]  
MED-LO 1025 [484]  
MED-HI 1185 [559]  
HIGH  
1345 [635]  
LOW  
835 [394]  
990 [467]  
820 [387]  
975 [460]  
1125 [531]  
1290 [609]  
800 [378]  
955 [451]  
1105 [522]  
1265 [597]  
775 [366]  
935 [441]  
1080 [510]  
1245 [588]  
750 [354]  
905 [427]  
1050 [496]  
1215 [573]  
720 [340]  
875 [413]  
1020 [481]  
1180 [557]  
685 [323]  
835 [394]  
980 [463]  
1140 [538]  
07MAUER  
07EAUE  
07EAUER  
11 x 6  
[279 x 152]  
1/2  
[373]  
MED-LO  
MED-HI 1140 [538]  
HIGH  
1300 [614]  
LOW  
1210 [571]  
1205 [569]  
1560 [736]  
1880 [887]  
2050 [967]  
1195 [564]  
1550 [732]  
1825 [861]  
1995 [942]  
1180 [557]  
1530 [722]  
1790 [845]  
1940 [916]  
1165 [550]  
1495 [706]  
1740 [821]  
1885 [890]  
1155 [545]  
1465 [691]  
1675 [791]  
1835 [866]  
1130 [533]  
1430 [675]  
1600 [755]  
1770 [835]  
07MAMGR  
07EAMG  
07NAMGR  
11 x 7  
[279 x 178]  
3/4  
[559]  
MED-LO 1580 [746]  
MED-HI 1915 [904]  
HIGH  
0000  
*
*
*
LOW  
935 [441]*  
910 [429]*  
1055 [498]  
1210 [571]  
1395 [658]  
885 [418]*  
1040 [491]  
1190 [562]  
1370 [647]  
855 [404]*  
1010 [477]  
1165 [550]  
1340 [632]  
825 [389]*  
980 [463]  
1135 [536]  
1305 [616]  
785 [370]*  
945 [446]  
1095 [517]  
1265 [597]  
760 [359]*  
905 [427]  
1055 [498]  
1220 [576]  
11 x 7  
1/2  
MED-LO 1070 [505]  
MED-HI 1240 [585]  
10EAME*  
10NAMER  
[279 x 178]  
[373]  
HIGH  
1420 [670]  
LOW  
1330 [628]  
1295 [611]  
1670 [788]  
2085 [984]  
2410 [1137]  
1285 [606]  
1655 [781]  
2055 [970]  
2355 [1111]  
1245 [588]  
1615 [762]  
2005 [946]  
2305 [1088]  
1225 [578]  
1585 [748]  
1970 [930]  
2240 [1057]  
1205 [569]  
1565 [739]  
1945 [918]  
2165 [1022]  
1160 [547]  
1525 [720]  
1880 [887]  
2100 [991]  
10EBRJR  
10NBRJR  
11 x 10  
[279 x 254]  
3/4  
[559]  
MED-LO 1690 [798]  
MED-HI  
HIGH  
0000  
0000  
LOW  
MED-LO  
MED-HI  
HIGH  
1330 [628]  
0000  
1295 [611]  
1690 [798]  
2090 [986]  
2395 [1130]  
1280 [604]  
1660 [783]  
2035 [960]  
2335 [1102]  
1240 [585]  
1635 [772]  
1985 [937]  
2260 [1067]  
1215 [573]  
1580 [746]  
1930 [911]  
2185 [1031]  
1210 [571]  
1535 [724]  
1850 [873]  
2080 [982]  
1175 [555]  
1480 [698]  
1785 [842]  
1965 [927]  
12EARJR  
12NARJR  
11 x 10  
[279 x 254]  
3/4  
[559]  
0000  
0000  
LOW  
1300 [614]  
1280 [604]  
1650 [779]  
2075 [979]  
2340 [1104]  
1230 [580]  
1620 [765]  
2035 [960]  
2290 [1081]  
1205 [569]  
1570 [741]  
1990 [939]  
2215 [1045]  
1170 [552]  
1545 [729]  
1955 [923]  
2145 [1012]  
1115 [526]  
1485 [701]  
1900 [897]  
2080 [982]  
1030 [486]  
1425 [673]  
1815 [857]  
1995 [942]  
15MARJR  
15EARJR  
15NARJR  
11 x 10  
[279 x 254]  
3/4  
[559]  
MED-LO 1675 [791]  
MED-HI 2105 [993]  
HIGH  
0000  
NOTES: *Not to be used as a heating speed.  
Data compiled with factory filters installed.  
[
] Designates Metric Conversions  
Rheem Manufacturing Company  
5
 
ACCESSORIES—DOWNFLOW  
DOWNFLOW WARNING: Unit design is certified for installation on non-com-  
bustible floor. A special factory supplied combustible floor sub-base is  
required when installing on a combustible floor. Failure to install the sub-base  
may result in fire, property damage and personal injury.  
PLENUM DATA—“A” COILS  
Plenum adapters are required in some instances for use on downflow applications  
when plenum and furnace size do not match.  
FURNACE  
WIDTH  
PLENUM  
WIDTH  
PLENUM ADAPTER  
DOWNFLOW  
COIL  
PLENUM  
COMBUSTIBLE FLOOR BASE DIMENSIONS  
IN. [mm]  
IN. [mm]  
14 [356]  
14 [356]  
171/2 [445]  
171/2 [445]  
171/2 [445]  
171/2 [445]  
21 [533]  
21 [533]  
241/2 [622]  
241/2 [622]  
161/4 [413]  
201/4 [514]  
161/4 [413]  
201/4 [514]  
215/8 [549]  
251/4 [641]  
221/4 [565]  
251/4 [641]  
251/4 [641]  
215/8 [549]  
RXAA-C178  
RXAA-C179  
RXAA-C186  
RXAA-C180  
RXAA-C189  
RXAA-C181  
RXAA-C182  
RXAA-C183  
RXAA-C184  
RXAA-C190  
RXAL-B16BU  
RXAL-B20BU  
RXAL-B16BU  
RXAL-B20BU  
RXAL-B21BU  
RXAL-B25BU  
RXAL-B22BU  
RXAL-B25BU  
RXAL-B25BU  
RXAL-B21BU  
COMBUSTIBLE  
FLOOR BASE  
USE WITH  
A
B
C
FURNACE SIZES  
IN. [mm] IN. [mm] IN. [mm]  
RXGC-B14  
RXGC-B17  
RXGC-B21  
RXGC-B24  
RGLH-05  
141/2 [368] 131/4 [337] 111/4 [286]  
RGLH-07, RGLH-10(-)A 18 [457] 163/4 [425] 143/4 [451]  
RGLH-10(-)B  
RGLH-12, RGLH-15  
211/2 [546] 201/4 [514] 181/4 [464]  
25 [635] 233/4 [603] 213/4 [552]  
NOTE: See Form Number C11-206 for MultiFlex coil data.  
RXPF-F01 and F02  
FOSSIL FUEL KITS—are for use  
with Rheem Heat Pumps and  
Criterion II warm air furnaces. The  
RXPF-F02 meets TVA requirements.  
RXGF-CC*  
FILTER RACK—Downflow top  
return mount.  
NOTE: Filter racks are shipped  
without filters.  
*Filters available through  
PROSTOCK.  
OPTION CODE FOR HIGH  
ALTITUDE: US-277  
Canada-298  
(Kit packaged with furnace.  
Requires field installation.)  
GENERAL TERMS OF LIMITED WARRANTY  
Rheem will furnish a replacement for any part of this product  
which fails in normal use and service within the applicable  
period stated, in accordance with the terms of the limited  
warranty.  
Gas Heat Exchanger Limited Warranty .......Twenty (20) Years  
*Any Other Part..............................................One (5) Years  
*This five year limited warranty is applicable only to single-phase products  
installed in residential applications on or after January 1, 2001.  
For Complete Details of the Limited Warranty, Including Applicable Terms  
and Conditions, See Your Local Installer or Contact the Manufacturer for  
a Copy.  
6
Rheem Manufacturing Company  
 
NOTES  
Rheem Manufacturing Company  
7
 
RHEEM  
AIR CONDITIONING  
DIVISION  
Before proceeding with installation, refer  
to installation instructions packaged  
with each model, as well as complying  
with all Federal, State, Provincial, and  
Local codes, regulations, and practices.  
5600 Old Greenwood Road, Fort Smith, Arkansas 72908  
“In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.”  
PRINTED IN U.S.A.  
11-01 DC  
FORM NO. G11-449 REV. 6  
Supersedes Form No. G11-449 Rev. 5  
 

Radio Shack Electronic Keyboard 42 4062 User Guide
Raypak Boiler 399B 2339B User Guide
RCA Telephone 29292 User Guide
Roland Crib Toy mv8000 User Guide
Samsung DVD Player DVD C631P User Guide
Samsung Home Security System SCV 2080R User Guide
Saturn Automobile 2008 Sky User Guide
Schwinn Home Gym 113 213 User Guide
Senco Nail Gun YK0361 User Guide
Sennheiser Headphones 502864 User Guide