Renesas Computer Hardware H8SX 1520 User Guide

REJ10B0173-0100  
H8SX/1520 Group FP-100M  
User System Interface Cable  
User’s Manual  
Renesas Microcomputer Development Environment System  
HS1527ECH61H  
Rev.1.00  
RevDisowionlonadDfroamtWew:w.JSoamnan.ua1ls2.co,m2. A0ll 0Ma5nuals Search And Download.  
Preface  
The HS1527ECH61H is a user system interface cable that connects an H8SX/1520 group E6000H  
emulator (HS1527KEPH60H; hereinafter referred to as the emulator) to the IC socket for an  
FP-100M package for the H8SX/1520 group MCU on the user system.  
i
 
Contents  
Section 1 Configuration....................................................................................1  
Section 2 Connection Procedures......................................................................3  
2.1 Connecting User System Interface Cable to Emulator Station..........................................3  
2.2 Connecting User System Interface Cable to User System.................................................5  
2.2.1 Installing IC Socket..............................................................................................5  
2.2.2 Soldering IC Socket .............................................................................................5  
2.2.3 Inserting Cable Head............................................................................................6  
2.2.4 Fastening Cable Head ..........................................................................................6  
2.2.5 Fastening Cable Body..........................................................................................8  
2.3 Recommended Dimensions for User System Mount Pad..................................................9  
2.4 Dimensions for User System Interface Cable Head ..........................................................10  
2.5 Resulting Dimensions after Connecting User System Interface Cable..............................11  
Section 3 Installing the MCU to the User System.............................................12  
Section 4 Verifying Operation...........................................................................14  
Section 5 Notice.................................................................................................15  
ii  
 
Section 1 Configuration  
CAUTION  
Use an IC149-100-054-B51 socket (manufactured by  
YAMAICHI ELECTRONICS Co., Ltd.) for the FP-100M package  
IC socket on the user system.  
Figure 1 shows the configuration of the HS1527ECH61H user system interface cable for the  
FP-100M package.  
To emulator station  
Cable body  
Screws (M2.6 x 12 mm)  
with flat washers  
(for fastening cable head)  
Screws (M2.6 x 6 mm)  
with flat washers  
Socket cover  
Cable head  
IC socket  
User system  
Figure 1 HS1527ECH61H User System Interface Cable  
1
 
Table 1 lists the HS1527ECH61H components. Please make sure you have all of these components  
when unpacking.  
Table 1  
HS1527ECH61H Components  
No. Component  
Quantity  
Remarks  
1
2
3
4
5
6
Cable body  
1
1
1
1
4
4
Cable  
Cable head  
IC socket  
For the FP-100M package  
Socket cover  
For installing an FP-100M packaged MCU  
For fastening cable head (with four flat washers)  
Screws (M2.6 x 12 mm)  
Screws (M2.6 x 6 mm)  
For installing an FP-100M packaged MCU (with  
four flat washers)  
7
Documentation  
1
User’s manual for HS1527ECH61H (this manual)  
2
 
Section 2 Connection Procedures  
2.1  
Connecting User System Interface Cable to Emulator Station  
WARNING  
Observe the precautions listed below. Failure to do so  
will result in a FIRE HAZARD and will damage the user  
system and the emulator product or will result in  
PERSONAL INJURY. The USER PROGRAM will be  
LOST.  
1. Always switch OFF the user system and the emulator  
product before the USER SYSTEM INTERFACE CABLE  
is connected to or removed from any part. Before  
connecting, make sure that pin 1 on both sides are  
correctly aligned.  
2. The user system interface cable dedicated to the  
emulator must be used.  
To connect the cable body to the emulator station, follow the instructions below.  
1. Make sure the user system and emulator station are turned off.  
CAUTION  
When connecting or removing the user system interface  
cable, apply force only in the direction suitable for  
connection or removal, while making sure not to bend or  
twist the cable or connectors. Otherwise, the connectors  
will be damaged.  
3
 
2. After making sure the direction of the cable body connector is correct, firmly insert the cable  
body connector into the emulator station socket (figure 2).  
E6000H  
RENESAS  
HS1527KEPH60H  
emulator station  
Cable body connector  
User system interface cable  
Figure 2 Example of the HS1527KEPH60H Emulator Station  
4
 
2.2  
Connecting User System Interface Cable to User System  
WARNING  
Always switch OFF the user system and the emulator  
product before the USER SYSTEM INTERFACE CABLE  
is connected to or removed from any part. Before  
connecting, make sure that pin 1 on both sides are correctly  
aligned. Failure to do so will result in a FIRE HAZARD and  
will damage the user system and the emulator product or  
will result in PERSONAL INJURY. The USER PROGRAM will  
be LOST.  
To connect the cable head to the user system, follow the instructions below.  
2.2.1 Installing IC Socket  
After checking the location of pin 1 on the IC socket, apply epoxy resin adhesive to the bottom of the  
IC socket for an FP-100M package, and fasten it to the user system before soldering.  
2.2.2  
Soldering IC Socket  
After fastening, solder the IC socket for an FP-100M package to the user system. Be sure to  
completely solder the leads so that the solder slops gently over the leads and forms solder fillets.  
(Use slightly more solder than the MCU.)  
5
 
2.2.3  
Inserting Cable Head  
CAUTION  
Check the location of pin 1 before inserting.  
Align pin 1 on the IC socket for an FP-100M package on the user system with pin 1 on the user  
system interface cable head, and insert the user system interface cable head into the IC socket on the  
user system, as shown in figure 3.  
2.2.4  
Fastening Cable Head  
CAUTION  
1. Use a Philips-type screwdriver whose head matches  
the screw head.  
2. The tightening torque must be 0.0785 N•m or less.  
If the applied torque cannot be accurately measured,  
stop tightening when the force required to turn the screw  
becomes significantly greater than that needed when first  
tightening. If a screw is tightened too much, the screw  
head may break or an IC socket contact error may be  
caused by a crack in the IC socket solder.  
3. If the emulator does not operate correctly, cracks might  
have occurred in the solder. Check conduction with  
a tester and re-solder the IC socket if necessary.  
6
 
Fasten the user system interface cable head to the IC socket for an FP-100M package on the user  
system with the four screws (M2.6 x 12 mm; with four flat washers) provided. Each screw should be  
tightened a little at a time, alternating between screws on opposing corners. Take special care, such  
as manually securing the IC socket soldered area, to prevent the soldered IC socket from being  
damaged by overtightening the screws or twisting the components.  
Screws (M2.6 x 12 mm)  
with flat washers  
Cable head  
Pin 1  
IC socket  
(IC149-100-054-B51  
manufactured by  
YAMAICHI ELECTRONICS Co., Ltd.)  
User system  
Figure 3 Connecting User System Interface Cable to User System  
7
 
2.2.5  
Fastening Cable Body  
Connect the cable body to the cable head.  
Cable body  
Removing  
Push the remove jigs  
Remove jig  
Cable head  
User system  
Figure 4 Fastening Cable Body  
8
 
2.3  
Recommended Dimensions for User System Mount Pad  
Figure 5 shows the recommended dimensions for the mount pad (footprint) for the user system with  
an IC socket for an FP-100M package (IC149-100-054-B51: manufactured by YAMAICHI  
ELECTRONICS Co., Ltd.). Note that the dimensions in figure 5 are somewhat different from those  
of the actual chip's mount pad.  
17.10 (min.)  
13.80 (max.)  
0.5 x 24 = 12.00 ± 0.05  
0.50 ± 0.05  
0.30 ± 0.05  
Unit: mm  
Figure 5 Recommended Dimensions for Mount Pad  
9
 
2.4  
Dimensions for User System Interface Cable Head  
The dimensions for the user system interface cable head are shown in figure 6.  
29.5  
17.0  
63.50  
Unit: mm  
Tolerance: ±0.5 mm  
Figure 6 Dimensions for User System Interface Cable Head  
10  
 
2.5  
Resulting Dimensions after Connecting User System Interface Cable  
The resulting dimensions, after connecting the user system interface cable head to the user system,  
are shown in figure 7.  
Cable head  
IC socket  
(IC149-100-054-B51  
manufactured by  
YAMAICHI ELECTRONICS Co. Ltd.)  
User system  
Unit: mm  
Tolerance: ±0.5 mm  
Figure 7 Resulting Dimensions after Connecting User System Interface Cable  
11  
 
Section 3 Installing the MCU to the User System  
CAUTION  
1. Check the location of pin 1 before inserting.  
2. Use a Philips-type screwdriver whose head matches  
the screw head.  
3. The tightening torque must be 0.0785 N•m or less.  
If the applied torque cannot be accurately measured,  
stop tightening when the force required to turn the screw  
becomes significantly greater than that needed when first  
tightening. If a screw is tightened too much, the screw  
head may break or an IC socket contact error may be  
caused by a crack in the IC socket solder.  
4. If the MCU does not operate correctly, cracks might have  
occurred in the solder. Check conduction with a tester  
and re-solder the IC socket if necessary.  
Check the location of pin 1 before inserting the MCU into the IC socket on the user system, as shown  
in figure 8. After inserting the MCU, fasten the socket cover with the provided four screws (M2.6 x  
6 mm; with four flat washers). Take special care, such as manually securing the IC socket soldered  
area, to prevent the IC socket from being damaged by overtightening the screws or twisting the  
components.  
12  
 
Screws (M2.6 x 6 mm)  
with flat washers  
Socket cover  
MCU  
Pin 1  
IC socket  
(IC149-100-054-B51  
manufactured by  
YAMAICHI ELECTRONICS Co., Ltd.)  
User system  
Figure 8 Installing MCU to User System  
13  
 
Section 4 Verifying Operation  
1. Turn on the emulator according to the procedures described in the H8SX/1650 E6000H Emulator  
User's Manual (HS1650EPH60HE).  
2. Verify the user system interface cable connections by checking the pin states with the CHECK  
command (emulator command). If an error is detected, recheck the soldered IC socket and the  
location of pin 1.  
3. The emulator connected to this user system interface cable supports three kinds of clock sources  
as the MCU clock: an emulator internal clock, an external clock on the user system, and a crystal  
oscillator to be mounted on the EV-chip board. For details, refer to the H8SX/1650 E6000H  
Emulator User's Manual (HS1650EPH60HE).  
To use the emulator internal clock  
Select the clock in the emulator by using the CLOCK command (emulator command).  
To use the external clock on the user system  
Select the external clock with the CLOCK command (emulator command). Supply the  
external clock from the user system to the emulator by inputting the external clock from the  
EXTAL terminal on the cable head or connecting a crystal oscillator to the EXTAL and  
XTAL terminals. For details, refer to the H8SX/1520 Group Hardware Manual.  
To use the crystal oscillator mounted on the EV-chip board  
Install a crystal oscillator into the crystal oscillator terminals on the EV-chip board.  
Figure 9 shows the oscillator circuit on the user system interface cable.  
1 M  
HCU04  
To E6000H  
emulator  
HCU04  
270 Ω  
EXTAL XTAL  
Figure 9 Oscillator Circuit  
14  
 
Section 5 Notice  
1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head  
before inserting the cable head into the user system IC socket.  
2. This user system interface cable is specifically designed for the HS1527KEPH60H emulator. Do  
not use this cable with any other emulator station.  
3. To prevent breaking of wires in the cable body, do not place heavy or sharp metal objects on the  
user system interface cable.  
4. While the emulator station is connected to the user system with the user system interface cable,  
force must not be applied to the cable head. Place the emulator station, user system interface  
cable, and user system as shown in the example in figure 10.  
Place components so that the cable body and cable head are  
parallel to the user system.  
Emulator's front-end unit  
Cable  
Cable head is parallel  
to emulator station  
Cable head is parallel  
to user system  
User system  
Figure 10 User System Interface Cable Location Example  
5. The P1 short connector is used for testing. Do not remove the jumper pin that is inserted in  
the side of pins 1 and 2.  
1
3
P4  
3
1
P1  
Figure 11 P1 and P4 Short Connectors  
15  
 
6. A level-shift circuit with AVcc0 and AVcc1 is mounted on the user system interface cable, as  
shown in figure 12. At shipment, the jumper pin is inserted in the side of pins 1 and 2 of the P4  
short connector. For details on the differences between the target MCU and the emulator, refer to  
the H8SX/1650 E6000H Emulator User's Manual (HS1650EPH60HE). For the ranges of input  
voltages of AVcc0 and AVcc1, refer to the H8SX/1520 Group Hardware Manual.  
CAUTION  
Insert the jumper pin in the P4 short connector so that  
the higher voltage between AVcc0 and AVcc1 is selected.  
Select either AVcc0 or AVcc1 when their potentials are  
the same. Do not use the emulator without jumper pins.  
User system interface  
AVcc0  
Emulator station  
5 V  
1.03 k  
+
UVREF3  
-
2 k  
AVss  
1
3
AVcc1  
AVcc of MCU  
5 V  
of the emulator  
station  
1.03 k  
P4  
+
-
UVREF1  
2 k  
Settings of short connector:  
Between pins 1 and 2: AVcc0  
Between pins 2 and 3: AVcc1  
AVss  
Figure 12 Level-shift Circuit with AVcc0 and AVcc1  
16  
 
Renesas Microcomputer Development Environment System  
User's Manual  
H8SX/1520 Group FP-100M User System Interface Cable  
Publication Date: Rev.1.00, January 12, 2005  
Published by:  
Sales Strategic Planning Div.  
Renesas Technology Corp.  
Edited by:  
Technical Documentation & Information Department  
Renesas Kodaira Semiconductor Co., Ltd.  
2005. Renesas Technology Corp., All rights reserved. Printed in Japan.  
 
Sales Strategic Planning Div. Nippon Bldg., 2-6-2, Ohte-machi, Chiyoda-ku, Tokyo 100-0004, Japan  
RENESAS SALES OFFICES  
Refer to "http://www.renesas.com/en/network" for the latest and detailed information.  
Renesas Technology America, Inc.  
450 Holger Way, San Jose, CA 95134-1368, U.S.A  
Tel: <1> (408) 382-7500, Fax: <1> (408) 382-7501  
Renesas Technology Europe Limited  
Dukes Meadow, Millboard Road, Bourne End, Buckinghamshire, SL8 5FH, U.K.  
Tel: <44> (1628) 585-100, Fax: <44> (1628) 585-900  
Renesas Technology Hong Kong Ltd.  
7th Floor, North Tower, World Finance Centre, Harbour City, 1 Canton Road, Tsimshatsui, Kowloon, Hong Kong  
Tel: <852> 2265-6688, Fax: <852> 2730-6071  
Renesas Technology Taiwan Co., Ltd.  
10th Floor, No.99, Fushing North Road, Taipei, Taiwan  
Tel: <886> (2) 2715-2888, Fax: <886> (2) 2713-2999  
Renesas Technology (Shanghai) Co., Ltd.  
Unit2607 Ruijing Building, No.205 Maoming Road (S), Shanghai 200020, China  
Tel: <86> (21) 6472-1001, Fax: <86> (21) 6415-2952  
Renesas Technology Singapore Pte. Ltd.  
1 Harbour Front Avenue, #06-10, Keppel Bay Tower, Singapore 098632  
Tel: <65> 6213-0200, Fax: <65> 6278-8001  
Colophon 2.0  
 
H8SX/1520 Group FP-100M  
User System Interface Cable  
HS1527ECH61H User’s Manual  
 

Rangemaster Cooktop RC60 User Guide
RCA Stereo Receiver SUBWOOFER SATELLITE SPEAKERS User Guide
Rheem Portable Generator GEN 30B User Guide
RocketFish Network Card RF RBCARD User Guide
RocketFish Speaker System RF RBWS01 User Guide
Samsung Cooktop SCD103 215 User Guide
Samsung DVD Player VR330S User Guide
Samsung Telephone SP C700R User Guide
Schumacher Battery Charger SF 51A PE User Guide
Sears Refrigerator 53071 User Guide