I S C S I H O S T B U S A D A P T E R I N S T A L L A T I O N  
z
®
Q L A 4 0 5 0 / 4 0 5 0 C / 4 0 5 2 C  
Q L E 4 0 6 0 C / 4 0 6 2 C  
 
Quick Start Guide  
Installation Instructions  
®
This Quick Start Guide describes how to install and configure your new QLogic SANblade host bus adapter and  
SANsurfer iSCSI HBA Manager application in four simple steps:  
Step 1. Verify the package contents.  
Step 2. Install the host bus adapter hardware.  
Step 3. Install the host bus adapter driver.  
Step 4. Install the SANsurfer iSCSI HBA Manager application.  
Keep the host bus adapter in the antistatic bag until installation. The host bus adapter contains parts that can be  
damagedbyelectrostaticdischarge(ESD). Beforehandlingthehostbusadapter, usestandardmethodstodischarge  
static electricity. Place the host bus adapter on the bag when examining it. Retain the bag for future use.  
CAUTION!  
System Requirements  
Your system must have the functionality described in the following sections to support the QLogic SANblade host bus  
adapter.  
Minimum Software Requirements  
®
Windows 2000: Service Pack (SP) 4 or later (QLA405x host bus adapters)  
®
Windows Server 2003 SP 1 or SP 2  
Windows XP Pro SP 1 or SP 2  
Windows PE 2.0, 2004, 2005  
Windows Vista (Business and Enterprise)  
®
Linux RedHat EnterpriseLinux3.0Update7orlater(QLA405x hostbusadapters), LinuxRedHatEnterprise  
Linux 4.0 Update 3 or later (QLA405x and QLE406xC host bus adapters)  
Novell SUSE Linux: SLES 8 Update 3 or later (QLA405x host bus adapters), SLES 9 Update 2 or later (QLA405x  
and QLE406xC host bus adapters), SLES 10 (QLA405x and QLE406xC host bus adapters)  
Solaris: Solaris 9 or later for Solaris SPARC and x86 (IA32 and x64)  
®
VMware 3.0.1 (QLA405x host bus adapters)  
NOTE:  
The operating systems listed above are applicable to all host bus adapter models unless otherwise noted.  
Minimum Hardware Requirements  
Empty PCI-X 32-bit or PCI-X 64-bit slot (QLA405x host bus adapters), 2.5-GHz PCI Express x4 slot (QLE406xC  
host bus adapters)  
PCI-X: 3.3-volt signaling (QLA4050 host bus adapters); 3.3V or 5-volt signaling (QLA4050/4052C host bus  
adapters)  
The correct media:  
QLA4050: 62.5/125-µM multimode fiber  
QLA4050C/4052C, QLE4060C/4062C: UTP copper (Cat5E or Cat6)  
3
 
The correct connectors:  
QLA4050: LC duplex  
QLA4050C/4052C, QLE4060C/4062C: RJ45  
Step 1. Verify the Package Contents  
The QLogic host bus adapter is shipped with the following items:  
QLogic SANblade host bus adapter  
Low-profile bracket (not available in all models)  
Quick Start Guide (this document)  
®
SANsurfer for SANblade iSCSI HBAs CD(s)  
Step 2. Install the Host Bus Adapter Hardware  
NOTE:  
When installing the QLogic host bus adapter and driver in a Solaris system that does not already have QLogic  
host bus adapters or drivers installed, please install the QLogic Solaris driver before you install the QLogic host bus  
adapter hardware. This allows Solaris to correctly bind the QLogic Solaris driver to the QLogic host bus adapter. Failure  
to do so will require an additional system reboot after the driver is loaded.  
To install the host bus adapter hardware, you need to open the computer and locate the appropriate bus slot. If necessary,  
consult your computer system manual for instructions to remove the computer cover.  
Depending on the host bus adapter you are installing, the bus connector will look like one of the following samples:  
PCI-X  
PCI Express  
QLA4050  
N/A  
Optical  
QLA4050C  
QLA4052C  
QLE4060C  
QLE4062C  
Copper  
4
 
Follow these steps to install the host bus adapter hardware:  
1.  
2.  
3.  
4.  
5.  
6.  
7.  
Power off the computer, then disconnect the power cable.  
Remove the computer cover and find an empty bus slot.  
Pull out the slot cover (if any) by removing the screw or releasing the lever.  
Grasp the host bus adapter by the top edge and seat it firmly into the slot.  
Refasten the host bus adapter’s retaining bracket using the existing screw or lever.  
Close the computer cover.  
Plug in the power cable and turn on the computer.  
HOST BUS  
ADAPTER  
LEVER  
64-BIT PCI-X SLOT  
(QLA405x HOST BUS  
ADAPTERS) OR  
SCREW  
PCI EXPRESS x4, x8, x16  
SLOT (QLE406xC HOST BUS  
ADAPTERS)  
HOST BUS ADAPTER RE-  
TAINING BRACKET  
SLOT COVERS  
SYSTEM  
CHASSIS  
Sample motherboard and slots  
Step 3. Install the Host Bus Adapter Driver  
After you have completed the hardware installation and turned on the computer, insert the applicable SANsurfer for  
SANblade iSCSI HBAs CD into the CD-ROM drive, based on your operating system. Follow the instructions below for  
your operating system.  
The latest drivers and documentation can be found on the QLogic Web site, www.qlogic.com.  
Windows 2000 (QLA405x Host Bus Adapters only)  
NOTE:  
If an earlier version of the Windows 2000 driver is already installed, see the readme file for information about  
updating the existing driver.  
Perform the following steps to install the host bus adapter driver for Windows 2000:  
1.  
2.  
Log onto the computer as Administrator.  
Download and save the host bus adapter driver to your hard drive:  
a.  
TypeorbrowsethepathtotheQLogic driverdirectoryontheapplicable SANsurferforSANblade  
iSCSI HBAs CD. For example:  
<CD-ROM Drive Letter>:\autoplay\iSCSI_HBA_drivers\Windows  
5
 
 
b.  
c.  
Locate and launch (double-click) the executable (.exe) file containing the driver.  
Whenprompted, typeorbrowsetoalocationonyourharddrivetostorethedriverfiles. ClickOK.  
3.  
4.  
Windows detects the newly installed device, then displays the Found New Hardware with Ethernet  
Controller message. Click Next.  
In the Install Hardware Device Drivers dialog box, select Search for a suitable driver for my device  
(recommended). Click Next.  
5.  
6.  
In the Locate Driver Files dialog box, select Specify a Location. Click Next.  
In the Copy manufacture's files from: dialog box, type or browse the path to the directory where you  
stored the driver files <blue text>(see step 2). Click OK.  
7.  
8.  
9.  
In the Driver Files Search Results dialog box, click Next.  
In the Completing the Found New Hardware Wizard dialog box, click Finish.  
The Found New Hardware - Network Controller message displays. The Found New Hardware Wizard  
program is launched to begin installing the driver for the QLogic iSCSI HBA. Click Next.  
10. In the Install Hardware Device Drives dialog box, select Search for a suitable driver for my device  
(recommended). Click Next.  
11. Select specify a location. Click Next.  
12. In the Copy manufacture's files from: field, type or browse the path to the to the directory where you  
stored the driver files <blue text>(see step 2).  
13. In the Driver Files Search Results dialog box, click Next.  
14. When the Digital Signature Not Found dialog box displays, click Yes.  
15. In the Completing the Found New Hardware Wizard dialog box, click Finish.  
16. If following message displays, click Yes:  
Your hardware settings have changed. You must restart your computer  
for these changes to take effect. Do you want to restart your  
computer now?  
NOTE:  
If you are installing a dual-port QLA4052C host bus adapter, Steps 316 must be repeated for the second port.  
Windows Server 2003  
NOTE:  
If an earlier version of the Windows Server 2003 driver is already installed, see the readme file for information  
about updating the existing driver.  
Perform the following steps to install the host bus adapter driver for Windows Server 2003:  
1.  
2.  
Log onto the computer as Administrator.  
Download and save the host bus adapter driver to your hard drive:  
a.  
TypeorbrowsethepathtotheQLogic driverdirectoryontheapplicableSANsurferforSANblade  
iSCSI HBAs CD. For example:  
<CD-ROM Drive Letter>:\autoplay\iSCSI_HBA_drivers\Windows  
b.  
c.  
Locate and launch (double-click) the executable (.exe) file containing the driver.  
Whenprompted, typeorbrowsetoalocationonyourharddrivetostorethedriverfiles. ClickOK.  
3.  
Windows detects the newly installed device, then displays the Found New Hardware with Ethernet  
Controller message.  
4.  
5.  
Select Install from a list or specific location (Advanced), then click Next.  
SelecttheSearchforthebestdriverintheselocations option. Typeorbrowsethepathtothedirectory  
where you stored the driver files <blue text>(see step 2), then click Next.  
6.  
7.  
In the Security Alert - Driver Installation dialog box, click Yes.  
In the Completing the Found New Hardware Wizard dialog box, click Finish.  
6
 
     
8.  
9.  
The Found New Hardware Wizard with Network Controller message displays. The Found New  
Hardware Wizard program is launched to begin installing the iSCSI driver for the QLogic iSCSI HBA.  
Select Install from a list or specific location (Advanced). Click Next.  
10. SelecttheSearchforthebestdriverintheselocations option. Typeorbrowsethepathtothedirectory  
where you stored the driver files (see Step 2).  
11. In the Hardware Installation - Windows Logo dialog box, click Continue Anyway.  
12. In the Completing the Found New Hardware Wizard dialog box, click Finish.  
Windows Vista  
Initial Operating System Installation with the Host Bus Adapter Driver as Boot or as an Add-On  
Perform the following steps to install the Windows Vista operating system and the host bus adapter driver (as boot as  
or as an add-on):  
1.  
2.  
Start the Windows installation procedure using the Setup CD.  
The following message displays:  
Which type of installation do you want?  
Select Custom (Advanced).  
3.  
4.  
The following message displays:  
Select Load Driver.  
Download and save the host bus adapter driver to your hard drive:  
a.  
TypeorbrowsethepathtotheQLogic driverdirectoryontheapplicable SANsurferforSANblade  
iSCSI HBAs CD. For example:  
<CD-ROM Drive Letter>:\autoplay\iSCSI_HBA_drivers\Windows  
b.  
c.  
Locate and launch (double-click) the executable (.exe) file containing the driver.  
Whenprompted, typeorbrowsetoalocationonyourharddrivetostorethedriverfiles. ClickOK.  
5.  
6.  
At the Load Driver screen, type or browse the path to the directory where you stored the driver files  
<blue text>(see step 4), then click OK.  
Click Next to continue with the standard installation procedure.  
Adding the Host Bus Adapter Driver to an Existing Operating System  
Perform the following steps to add the host bus adapter driver to an existing operating system:  
1.  
After installing the iSCSI host bus adapter and restarting your computer, download and save the host  
bus adapter driver to your hard drive:  
a.  
TypeorbrowsethepathtotheQLogic driverdirectoryontheapplicable SANsurferforSANblade  
iSCSI HBAs CD. For example:  
<CD-ROM Drive Letter>:\autoplay\iSCSI_HBA_drivers\Windows  
Locate and launch (double-click) the executable (.exe) file containing the driver.  
Whenprompted, typeorbrowsetoalocationonyourharddrivetostorethedriverfiles. ClickOK.  
b.  
c.  
2.  
Windows detects the newly installed device and displays the Found New Hardware message.  
The Hardware Update Wizard program starts installing a device driver for the newly installed device.  
Select the Driver tab, then click Update Driver to start the Hardware Update Wizard.  
Select Browse my computer for driver software, then click Next.  
3.  
4.  
5.  
6.  
Select Let me pick from a list of device drivers on my computer, then click Next.  
Click Have Disk.  
7
 
   
7.  
On the Install from Disk screen, select the directory where you stored the driver files <blue text>(see  
step 1), then click OK.  
8.  
9.  
When the Update Driver Software Wizard/Select QLogic iSCSI Adapter window displays, click Next.  
Click Close on the Update Driver Software Wizard window.  
Linux (Driver and RAMDisk Image)  
The following installation instructions are applicable to SLES 9 (or later) or Red Hat Enterprise Linux 4.0 (or later). For  
more information and driver installation instructions for other Linux operating system versions, see the README.txt file  
associated with the driver.  
1.  
2.  
3.  
Download the latest driver file qla4xxx-vx.yy.zz.tar.gz from the SANsurfer for SANblade iSCSI HBAs  
CD. The driver is located in the following directory: autoplay\iscsi_HBA_drivers\Linux  
Type the following to uncompress the tar file:  
# tar -xvzf *.gz  
Type the following to compile the driver:  
# cd x.yy.zz  
# ./extras/build.sh install  
4.  
5.  
Type the following to load the driver:  
# modprobe –v qla4xxx  
Optionally, type the following to compile the driver and create a RAMDisk image that will automatically  
load the driver when the system is rebooted:  
# ./extras/build.sh initrd  
To unload the driver, type the following:  
# modprobe –r qla4xxx  
Solaris  
NOTE:  
If an earlier version of the Solaris driver is already installed, you must un-install this driver before installing  
the latest driver. For more information, see the section in the README.txt file about removing the driver.  
1.  
2.  
Login to the Solaris system as root.  
Type the following command to uncompress the package:  
uncompress <directory containing package file>/qla4xxx.Z  
Type the following command to start the package installation:  
3.  
4.  
pkgadd -d <directory containing package file>/qla4xxx  
Follow and answer the prompts displayed to finish the installation.  
a.  
b.  
c.  
When the package selection prompt displays, enter the number corresponding to the driver  
package applicable to the Solaris version installed on the target system.  
At the driver destination prompt, press ENTER to place the driver in the default directory, which  
is usually /kernel/drv.  
When prompted to continue and to complete the QLogic driver installation procedure,  
press Y.  
For more help, see the Solaris man page on pkgadd.  
After the pkgadd program completes, type the following command to reboot the system:  
reboot -- -r  
5.  
NOTE:  
Modify the system sd.conf file (/kernel/drv/sd.conf) for the operating system to recognize new targets. QLogic  
recommends adding up to 255 targets. The QLogic SANblade host bus adapter supports up to 128 devices.  
8
 
To unload the driver, perform the following steps:  
1.  
2.  
Login to the Solaris system as root.  
Type the following command:  
pkgrm QLA4xxx-0  
3.  
Type the following command to reboot the system:  
reboot -- -r  
Step 4. Install the SANsurfer iSCSI HBA Manager Application  
To install the SANsurfer iSCSI HBA Manager application:  
1.  
Insert the applicable SANsurfer for SANblade iSCSI HBAs CD into your CD-ROM drive (if the auto-run  
screen does not appear, open the start_here html page with your browser.)  
2.  
3.  
4.  
5.  
6.  
Select your operating system.  
Click I Accept on the License Agreement.  
Click to select the specific version of your operating system.  
Select the SANsurfer iSCSI HBA Manager install file.  
Follow the on-screen directions and installation prompts.  
Congratulations! You have successfully installed your QLogic Host Bus  
Adapter and management application!  
To obtain the most current drivers, management applications, user instructions, and documentation, please  
visit the QLogic website at www.qlogic.com/support and download the latest versions.  
The following section contains additional information about the SANblade QLogic host bus adapter, including  
the LED scheme, troubleshooting, warranty, technical support and certification information.  
Host Bus Adapter LEDs  
Table 1 lists the LED configuration for the QLogic QLA4050 host bus adapter.  
Table 1. QLogic QLA4050 Host Bus Adapter LED Scheme  
Green LED  
Activity  
Link established  
Table 2 lists the LED configuration for the QLogic QLA4050C/4052C and QLE4060C/4062C host bus adapters.  
Table 2. QLogic QLA4050C/4052C and QLE4060C/4062C Host Bus Adapter  
LED Scheme  
Green LED  
Activity  
Link established  
Receive/transmit activity  
Flashing  
9
 
   
Troubleshooting and Technical Support  
The QLogic knowledge database contains troubleshooting information and documentation for the QLogic SANblade host  
bus adapters. The knowledge base is available to all users at http://support.qlogic.com.  
For technical support, visit our web site support.qlogic.com, email us at [email protected], or call at 952-932-4040.  
Warranty  
The QLogic SANblade host bus adapter comes with a standard three year QLogic warranty. Please check the QLogic  
Web site at http://support.qlogic.com/support/warranty.asp for warranty details.  
Laser Safety  
FDA Notice  
This product complies with DHHS Rules 21CFR Chapter I, Subchapter J. This product has been designed and manufactured according to  
IEC60825-1 on the safety label of laser product.  
Class 1 Laser Product  
Caution—Class 1 laser radiation when open  
Do not view directly with optical instruments  
Appareil laser de classe 1  
Produkt der Laser Klasse 1  
Luokan 1 Laserlaite  
Attention—Radiation laser de classe 1  
Ne pas regarder directement avec des instruments optiques  
CLASS I LASER PRODUCT  
Vorsicht—Laserstrahlung der Klasse 1 bei geöffneter  
Abdeckung  
Direktes Ansehen mit optischen Instrumenten vermeiden  
Agency Certification  
QLogic SANblade Host Bus Adapters  
The following sections contain a summary of EMC/EMI test specifications performed on the following QLogic SANblade host bus adapters  
to comply with radiated emission, radiated immunity, and product safety standards:  
QLA4050  
(IS0710404)  
(IS0710407)  
(IS0710403)  
QLA4050C  
QLA4052C  
QLE4060C/QLE4062C (IX4010402)  
EMI and EMC Requirements  
FCC Part 15 compliance: Class B  
FCC compliance information statement: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two  
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including  
interference that may cause undesired operation.  
ICES-003 compliance: Class B  
This Class B digital apparatus complies with Canadian ICES-003.  
Cet appareil numériqué de la classe B est conformé à la norme NMB-003 du Canada.  
CE Mark 89/336/EEC EMC Directive compliance:  
EN55022:1998/CISPR22:1997—Class B  
EN55024:1998  
10  
 
Immunity Standards  
IEC61000-4-2  
IEC61000-4-3  
IEC61000-4-4  
IEC61000-4-5  
IEC61000-4-6  
IEC61000-4-8  
: ESD  
: RF Electro Magnetic Field  
: Fast Transient/Burst  
: Fast Surge Common/ Differential  
: RF Conducted Susceptibility  
: Power Frequency Magnetic Filed  
IEC61000-4-11 : Voltage Dips and Interrupt  
IEC61000-3-2  
IEC61000-3-3  
: Harmonic Current Emission  
: Voltage Fluctuation and Flicker  
VCCI compliance: Class B  
AS/NZS CISPR22 compliance: Class B  
CNS 13438 compliance: Class B  
MIC compliance: Class B  
Korea MIC Class B Certified  
Product Name/Model  
Certification holder  
iSCSI host bus adapter  
QLogic Corporation  
Manufactured date  
Refer to date code listed on product  
QLogic Corporation/USA  
Manufacturer/Country of origin  
B class equipment  
(Household purpose info/telecommunications  
equipment)  
As this equipment has undergone EMC registration for  
household purpose, this product can be used in any area  
including residential area.  
Korean Language Format— Class B  
Product Safety Compliance  
UL, cUL product safety compliance:  
UL60950  
CSA C22.2 No.60950  
Class 1 Laser Product per DHHS 21CFR (J)  
Use only with listed ITE or equivalent.  
73/23/ECC low voltage directive:  
TUV:  
-EN60950-1:2001  
-EN60825-1  
-EN60825-2  
11  
 
12  
 
13  
 
14  
 
© 2005–2009 QLogic Corporation. QLogic, theQLogiclogo, SANsurfer, and SANsurfer Mangement Suitearetrademarks  
or registered trademarks of QLogic Corporation. All other brands and product names are trademarks or registered  
trademarks of their respective owners. Information supplied by QLogic is believed to be accurate and reliable. QLogic  
Corporation assumes no responsibility for any errors in this brochure. QLogic Corporation reserves the right, without  
notice, to makes changes in product design or specifications.  
 
*IS0054501-00  D*  
QLogic Corporation  
949.389.6000  
26650 Aliso Viejo Parkway  
Aliso Viejo, CA 92656  
IS0054501-00 D  
 

Radio Shack Digital Camera 16 3898 User Guide
Raypak Boiler 302 902 User Guide
Reebok Fitness Home Gym RBEX39011 User Guide
Renesas Network Card HS2633ECH61H User Guide
Rolls Camera Accessories MX152 User Guide
Rosewill TV Mount RMS MT3710 User Guide
Samsung Home Theater System HT TZ312 User Guide
Samsung Model Vehicle 2013 User Guide
Samsung Stereo System HT SK6 User Guide
Sanyo Flat Panel Television DP32D13 User Guide