ESPAÑOL: PÁGINA 15
FRANÇAISE : PAGE 27
Instruction
manual
Double Insulated
Portable Electric
Screwdrivers
MODELS 4630 and 4634
Depth Sensing Drywall and Deck Drivers
MODEL 4640
Depth Sensing Fastener Driver
IMPORTANT
Please make certain that the person who is
to use this equipment carefully reads and
understands these instructions before
starting operations.
To learn more about Porter-Cable
visit our website at:
The Model and Serial No. plate is located on the main
housing of the tool. Record these numbers in the
spaces below and retain for future reference.
Model No. ______________________________________
Type ___________________________________________
Serial No._______________________________________
Copyright © 2005 Porter-Cable Corporation
Part No. 896132 - 03-10-05
SAFETY GUIDELINES - DEFINITIONS
It is important for you to read and understand this manual. The
information it contains relates to protecting YOUR SAFETY and
PREVENTING PROBLEMS. The symbols below are used to help
you recognize this information.
indicates an imminently hazardous situation which, if not
avoided, will result in death or serious injury.
indicates a potentially hazardous situation which, if not
avoided,could result in death or serious injury.
indicates a potentially hazardous situation which, if not
avoided,may result in minor or moderate injury.
used without the safety alert symbol indicates potentially
hazardous situation which, if not avoided, may result in
property damage.
CALIFORNIA PROPOSITION 65
Some dust created by power sanding, sawing, grinding, drilling,
and other construction activities contains chemicals known (to the
State of California) to cause cancer, birth defects or other reproductive harm. Some
examples of these chemicals are:
●
●
●
lead from lead-based paints
crystalline silica from bricks and cement and other masonry products
arsenic and chromium from chemically-treated lumber
Your risk from these exposures varies, depending on how often you do this
type of work. To reduce your exposure to these chemicals: work in a well
ventilated area, and work with approved safety equipment, always wear
NIOSH/OSHA approved, properly fitting face mask or respirator when using
such tools.
3
GENERAL SAFETY RULES
Read all instructions. Failure to follow all
instructions listed below may result in electric shock, fire and/or
serious injury. The term "power tool" in all of the warnings listed
below refers to your mains-operated (corded) power tool or
battery-operated (cordless) power tool.
SAVE THESE INSTRUCTIONS
1) Work area safety
a) Keep work area clean and well lit. Cluttered or dark areas invite
accidents.
b) Do not operate power tools in explosive atmospheres, such as in the
presence of flammable liquids, gases or dust. Power tools create
sparks which may ignite the dust or fumes.
c) Keep children and bystanders away while operating a power tool.
Distractions can cause you to lose control.
2) Electrical safety
a) Power tool plugs must match the outlet. Never modify the plug in any
way. Do not use any adapter plugs with earthed (grounded) power
tools. Unmodified plugs and matching outlets will reduce risk of electric
shock.
b) Avoid body contact with earthed or grounded surfaces such as
pipes, radiators, ranges and refrigerators. There is an increased risk of
electric shock if your body is earthed or grounded.
c) Do not expose power tools to rain or wet conditions. Water entering a
power tool will increase the risk of electric shock.
d) Do not abuse the cord. Never use the cord for carrying, pulling or
unplugging the power tool. Keep cord away from heat, oil, sharp
edges or moving parts. Damaged or entangled cords increase the risk
of electric shock.
e) When operating a power tool outdoors, use an extension cord
suitable for outdoor use. Use of a cord suitable for outdoor use reduces
the risk of electric shock.
3) Personal safety
a) Stay alert, watch what you are doing and use common sense when
operating a power tool. Do not use a power tool while you are tired
or under the influence of drugs, alcohol or medication. A moment of
inattention while operating power tools may result in serious personal
injury.
b) Use safety equipment. Always wear eye protection. Safety equipment
such as dust mask, non-skid safety shoes, hard hat, or hearing
protection used for appropriate conditions will reduce personal injuries.
c) Avoid accidental starting. Ensure the switch is in the off-position
before plugging in. Carrying power tools with your finger on the switch
or plugging in power tools that have the switch on invites accidents.
4
continued
GENERAL SAFETY RULES
d) Remove any adjusting key or wrench before turning the power tool
on. A wrench or a key left attached to a rotating part of the power tool
may result in personal injury.
e) Do not overreach. Keep proper footing and balance at all times. This
enables better control of the power tool in unexpected situations.
f) Dress properly. Do not wear loose clothing or jewelry. Keep your
hair, clothing and gloves away from moving parts. Loose clothes,
jewelry or long hair can be caught in moving parts.
g) If devices are provided for the connection of dust extraction and
collection facilities, ensure these are connected and properly used.
Use of these devices can reduce dust-related hazards.
4) Power tool use and care
a) Do not force the power tool. Use the correct power tool for your
application. The correct power tool will do the job better and safer at the
rate for which it was designed.
b) Do not use the power tool if the switch does not turn it on and off.
Any power tool that cannot be controlled with the switch is dangerous
and must be repaired.
c) Disconnect the plug from the power source before making any
adjustments, changing accessories, or storing power tools. Such
preventive safety measures reduce the risk of starting the power tool
accidentally.
d) Store idle power tools out of the reach of children and do not allow
persons unfamiliar with the power tool or these instructions to
operate the power tool. Power tools are dangerous in the hands of
untrained users.
e) Maintain power tools. Check for misalignment or binding of moving
parts, breakage of parts and any other condition that may affect the
power tools operation. If damaged, have the power tool repaired
before use. Many accidents are caused by poorly maintained power
tools.
f) Keep cutting tools sharp and clean. Properly maintained cutting tools
with sharp cutting edges are less likely to bind and are easier to control.
g) Use the power tool, accessories and tool bits etc., in accordance
with these instructions and in the manner intended for the
particular type of power tool, taking into account the working
conditions and the work to be performed. Use of the power tool for
operations different from those intended could result in a hazardous
situation.
5) Service
a) Have your power tool serviced by a qualified repair person using only
identical replacement parts. This will ensure that the safety of the
power tool is maintained.
5
ADDITIONAL SPECIFIC SAFETY RULES
1. Hold power tools by insulated gripping surfaces when performing
an operation where the cutting tool may contact hidden wiring or its
own cord. Contact with a "live" wire will make exposed metal parts of
the tool "live" and shock the operator.
2. Verify the direction of rotation before starting the tool. Never
attempt to change direction of rotation while switch is “ON”. To do
so, may damage interlock feature built into switch. Be sure switch is
“OFF” and motor has completely stopped before changing direction of
rotation.
3. Wear eye and hearing protection. Always use safety glasses. Everyday
eyeglasses are NOT safety glasses. USE CERTIFIED SAFETY EQUIPMENT.
Eye protection equipment should comply with ANSI Z87.1 standards.
Hearing equipment should comply with ANSI S3.19 standards.
4.
Use of this tool can generate and disburse dust or other
airborne particles, including wood dust, crystalline silica dust and
asbestos dust. Direct particles away from face and body. Always operate
tool in well ventilated area and provide for proper dust removal. Use dust
collection system wherever possible. Exposure to the dust may cause
serious and permanent respiratory or other injury, including silicosis (a
serious lung disease), cancer, and death. Avoid breathing the dust, and
avoid prolonged contact with dust. Allowing dust to get into your mouth or
eyes, or lay on your skin may promote absorption of harmful material.
Always use properly fitting NIOSH/OSHA approved respiratory protection
appropriate for the dust exposure, and wash exposed areas with soap and
water.
SAVE THESE INSTRUCTIONS!
SYMBOL
DEFINITION
........................ volts
V
A
........................ amperes
........................ hertz
........................ watts
........................ kilowatts
........................ farads
........................ microfarads
........................ litres
Hz
W
kW
F
µF
l
g
........................ grams
........................ kilograms
........................ bars
........................ pascals
........................ hours
........................ minutes
........................ seconds
........................ no-load speed
kg
bar
Pa
h
min
s
n0
…/min or …min 1 ......... Revolutions or reciprocations per minute
-
or d.c. ................ direct current
or a.c. ................ alternating current
6
2
........................ two-phase alternating current
2N
3
........................ two-phase alternating current with neutral
........................ three-phase alternating current
3N
........................ three-phase alternating current with neutral
........................ rated current of the appropriate fuse-link in amperes
........................ time-lag miniature fuse-link where X is the symbol
for the time/current characteristic, as given in IEC 60127
........................ protective earth
........................ class II tool
........................ IP symbol
IPXX
SAVE THESE INSTRUCTIONS!
MOTOR
Many Porter-Cable tools will operate on either D.C., or single phase 25 to 60
cycle A.C. current and voltage within plus or minus 5 percent of that shown on
the specification plate on the tool. Several models, however, are designed for
A.C. current only. Refer to the specification plate on your tool for proper voltage
and current rating.
Do not operate your tool on a current on which the
voltage is not within correct limits. Do not operate tools rated A.C.
only on D.C. current. To do so may seriously damage the tool.
EXTENSION CORD SELECTION
If an extension cord is used, make sure the conductor size is large enough to
prevent excessive voltage drop which will cause loss of power and possible
motor damage. A table of recommended extension cord sizes will be found in
this section. This table is based on limiting line voltage drop to 5 volts (10 volts
for 230 volts) at 150% of rated amperes.
If an extension cord is to be used outdoors, it must be marked with the suffix W-
A or W following the cord type designation. For example – SJTW-A to indicate it
is acceptable for outdoor use.
RECOMMENDED EXTENSION CORD SIZES FOR USE WITH PORTABLE ELECTRIC TOOLS
Length of Cord in Feet
115V
230V
25 Ft.
50 Ft.
50 Ft.
100 Ft. 150 Ft. 200 Ft.
250 Ft. 300 Ft.
500 Ft. 600 Ft.
400 Ft. 500 Ft.
800 Ft. 1000 Ft.
100 Ft. 200 Ft. 300 Ft. 400 Ft.
0-2
2-3
18
18
18
18
18
18
18
16
16
16
14
14
18
18
18
18
16
16
14
14
12
12
12
12
18
16
16
14
14
12
12
10
10
10
8
16
14
14
12
12
10
10
8
16
14
12
12
10
10
8
14
12
12
10
10
8
14
12
10
10
8
12
10
10
8
12
10
8
3-4
4-5
8
5-6
8
6
6-8
6
6
6
8-10
10-12
12-14
14-16
16-18
18-20
8
6
6
4
8
6
6
4
4
8
6
6
6
4
2
8
6
6
4
4
2
8
6
4
4
2
2
8
6
6
4
4
2
2
7
CARTON CONTENTS
Carton contents include the screwdriver, an instruction manual, and a parts list.
FUNCTIONAL DESCRIPTION
FOREWORD
Porter-Cable screwdrivers are designed to install or remove various sizes and
types of fasteners.
ASSEMBLY
NOTE: This tool is shipped completely assembled. No assembly time or tools
are required.
OPERATION
TO START AND STOP THE TOOL
Make sure that the switch is off before connecting the
tool to the power source.
Check to see that the switch is “OFF”. Make sure that the power circuit voltage
is the same as that shown on the specification plate of the tool. Connect the drill
to the power circuit.
1. Squeeze the trigger switch (A)
Fig. 1 to start the motor. Release
the trigger to stop the motor.
B
C
2. A lock button (B) Fig. 1 is pro-
vided to keep the motor running
without holding the trigger switch
“ON”. TO LOCK the trigger
switch “ON”, squeeze the trigger
as far as it will go, push in lock
button and release trigger. TO
UNLOCK the lock button,
squeeze the trigger and release,
leaving the lock button free to
spring out.
Fig. 1
A
NOTE: The lock button can be engaged only when the tool is running at
maximum speed.
Never use the lock button when the tool may have to be
stopped suddenly.
3. These tools will operate in either the forward direction (clockwise rotation)
for drilling holes, or the reverse direction (counter-clockwise rotation) for
releasing jammed drill bits. For counter-clockwise rotation, stop the motor
by releasing the trigger switch and push the reversing switch (C) Fig. 1
toward the right side of the drill, or in the opposite direction for clockwise
rotation.
8
Never attempt to change direction of rotation while the switch
is “ON”. To do so, may damage interlock feature built into
switch. Be sure that the switch is “OFF” and the motor has
completely stopped before changing the direction of rotation.
4. VARIABLE SPEED – As the trigger switch is squeezed, the tool speed
increases.
TO CHANGE HEX NUTSETTER – MODEL 4640
DISCONNECT TOOL FROM POWER SOURCE.
1. Pull the Depth Stop Assembly (A) Fig. 2 from the clutch housing (B).
2. Pull the nutsetter (C) Fig. 3 straight out. If it is difficult to remove, grip it with
pliers and pull.
3. Push the nutsetter into the screwdriver spindle until the ball in the spindle
snaps into the groove in the nutsetter shank.
4. Replace the depth stop assembly and adjust for depth of drive (see
“ADJUST DEPTH STOP, MODEL 4640”).
C
A
B
Fig. 3
Fig. 2
ADJUST DEPTH STOP – MODEL 4640
1. Turn the adjusting collar (A) Fig. 2 until the end of the depth stop is flush with
the end of the nutsetter. Do not push the nutsetter in. This will engage the
internal drive.
2. Drive a test fastener into a piece of scrap material identical to the workpiece.
Examine the results of the drive and make any necessary depth stop
adjustments.
a) To increase the depth of drive, repeat STEP 1 and turn the adjusting
collar so that the end of the nutsetter extends beyond the end of the
depth stop.
b) To decrease the depth of drive, repeat STEP 1 and turn the adjusting
collar so that the end of the depth stop extends beyond the end of the
nutsetter.
Each click of the adjusting collar results in .007" change in the depth of drive.
3. Repeat STEPS 1 and 2 until the desired result is obtained.
9
CHANGE BIT HOLDER – MODELS 4630, 4634
DISCONNECT TOOL FROM POWER SOURCE.
1. Pull the Depth Stop Assembly (A)
Fig. 4 from the clutch housing.
2. Pull the bit holder (C) Fig. 4 out. If
it is difficult to remove, grip it with
pliers and pull.
B
NOTE: You can remove the bit (B) Fig.
4 from the bit holder by pulling it
straight out.
A
3. Push the new bit holder into the
spindle and snap it into place.
4. Replace the Depth Stop Assem-
bly and adjust the depth stop
(see “ADJUST DEPTH STOP,
MODELS 4630 AND 4634”).
C
Fig. 4
ADJUST DEPTH STOP – MODELS 4630 AND 4634
1. Turn the adjusting collar until the end of the bit extends 3/32" beyond the
end of the depth stop. Do not push the bit holder in. This will engage the
internal drive.
2. Drive a test fastener in the same material as your workpiece. Examine the
results and make any additional depth stop adjustments:
a) To increase the depth of drive, repeat STEP 1 and turn the adjusting
collar so that the end of the bit extends further than the end of the
depth stop.
b) To decrease depth of drive, repeat STEP 1 and turn the adjusting collar
so that the end of the bit is closer to the end of depth stop. Each click
of the adjusting collar results in a .007" change in the depth of drive.
3. Repeat STEPS 1 and 2 until the desired result is obtained.
DRIVING DRYWALL SCREWS – MODELS 4630, 4634
NOTE: Maximum size screw for use with this tool is #12 Wood Screw.
1. Install a drywall bit and bit holder in the screwdriver.
2. Set the screwdriver for the correct rotation.
3. Start the screwdriver and place a drywall screw on the bit.
Do not exert pressure on the screw while performing this
operation.
4. Place the end of the screw in the desired location and remove your fingers.
5. Apply forward pressure to the drive screw until the depth stop rests on the
surface of the work. Adjust the depth stop so that the fastener head is sunk
just below the surface of the wallboard.
10
DRIVING SELF-DRILLING/TAPPING SCREWS – MODELS 4640
NOTE: Maximum size screws for use with this tool are #12 wood screws and 1/4"
self-drilling/tapping screws.
These screws drill and tap their own hole as they are driven. This differs from
self-tapping screws in that pre-drilled holes for tapping are not required. To drive
these screws:
1. Install the proper nutsetter that fits the screw to the screwdriver.
2. Set the screwdriver for the correct rotation.
3. Start the screwdriver and insert the head of the screw in the nutsetter.
Do not exert pressure on the screw while performing this operation.
4. Place the end of the screw in the desired location and remove your fingers.
5. Apply forward pressure to drive screw until depth stop rests on the surface
of the work. Adjust the depth stop so that the fastener head seats firmly on
the work. Avoid seating the fastener too deep to prevent shearing off the
head.
TO REMOVE SCREWS – ALL MODELS
1. Remove the Depth Stop Assembly.
2. Install a proper bit that fits the screw.
3. Set the screwdriver for reverse rotation.
4. Place the bit on the screw and apply forward pressure.
5. Start the screwdriver.
TROUBLESHOOTING
list of service centers or call the Porter-Cable help line at 1-800-487-8665.
MAINTENANCE
CHECK CLUTCH CONDITION
DISCONNECT TOOL FROM POWER SOURCE.
A
Periodically, check the screwdriver
clutch jaws for wear by removing the
screwdriver mechanism housing (A)
Fig. 5 from the power unit.
Fig. 5
11
NOTE: The clutch housing is attached to the power unit with left-hand threads.
Remove the depth-stop assembly from the clutch housing by pulling it straight
off. Remove the clutch housing by turning the clutch housing clockwise.
NOTE: Be careful not to lose the small spring that is in the end of the power unit
spindle shaft.
Note the condition of the 3-jaw clutch faces on the power unit and screwdriver
mechanism. If they are badly rounded where the angular face meets the top
surface (or appear otherwise worn or faulty), or if the clutch elements are not
securely held in place on their respective shafts by the snap rings, return the
entire tool to your AUTHORIZED PORTER-CABLE SERVICE STATION for
service.
If the jaws are not seriously worn and no other apparent faults show up in the
mechanism, clear the mechanism and all internal areas of chips or other foreign
material. Brush a thin coat of PORTER-CABLE gear lubricant on the clutch
elements and surrounding areas. Attach the screwdriver mechanism to the
power unit. Be sure the spring is in the spindle shaft.
NOTE: The housing threads are left-hand thread.
KEEP TOOL CLEAN
Periodically blow out all air passages with dry compressed air. All plastic parts
should be cleaned with a soft damp cloth. NEVER use solvents to clean plastic
parts. They could possibly dissolve or otherwise damage the material.
Wear ANSI Z87.1 safety glasses while using compressed air.
FAILURE TO START
Should your tool fail to start, check to make sure the prongs on the cord plug
are making good contact in the outlet. Also, check for blown fuses or open
circuit breakers in the line.
LUBRICATION
This tool has been lubricated with a sufficient amount of high grade lubricant for
the life of the unit under normal operating conditions. No further lubrication is
necessary.
BRUSH INSPECTION (If applicable)
For your continued safety and electrical protection, brush inspection and
replacement on this tool should ONLY be performed by an AUTHORIZED
PORTER-CABLE SERVICE STATION or a PORTER-CABLE•DELTA FACTORY
SERVICE CENTER.
At approximately 100 hours of use, take or send your tool to your nearest
authorized Porter-Cable Service Station to be thoroughly cleaned and inspected.
Have worn parts replaced and lubricated with fresh lubricant. Have new brushes
installed, and test the tool for performance.
Any loss of power before the above maintenance check may indicate the need
for immediate servicing of your tool. DO NOT CONTINUE TO OPERATE TOOL
UNDER THIS CONDITION. If proper operating voltage is present, return your
tool to the service station for immediate service.
12
SERVICE
REPLACEMENT PARTS
When servicing use only identical replacement parts. For a service parts list or to
learn more about Porter-Cable visit our website at www.porter-cable.com
SERVICE AND REPAIRS
All quality tools will eventually require servicing, or replacement of parts due to
wear from normal use. For assistance with your tool, visit our website at
www.porter-cable.com for a list of service centers or call the Customer Care
Department at 1-800-487-8665. All repairs made by our service centers are fully
guaranteed against defective material and workmanship. We cannot guarantee
repairs made or attempted by others.
Should you have any questions about your tool, feel free to write us at any time.
In any communications, please give all information shown on the nameplate of
your tool (model number, type, serial number, etc.).
ACCESSORIES
A complete line of accessories is available from your Porter-Cable•Delta
Supplier, Porter-Cable•Delta Factory Service Centers, and Porter-Cable
Authorized Service Stations. Please visit our Web Site www.porter-cable.com
for a catalog or for the name of your nearest supplier.
Since accessories other than those offered by
Porter-Cable•Delta have not been tested with this product, use of
such accessories could be hazardous. For safest operation, only
Porter-Cable•Delta recommended accessories should be used
with this product.
13
WARRANTY
PORTER-CABLE LIMITED
ONE YEAR WARRANTY
Porter-Cable warrants its Professional Power Tools for a period of one year from the date of original
purchase. We will repair or replace at our option, any part or parts of the product and accessories
covered under this warranty which, after examination, proves to be defective in workmanship or
material during the warranty period. For repair or replacement return the complete tool or accessory,
transportation prepaid, to your nearest Porter-Cable Service Center or Authorized Service Station.
Proof of purchase may be required. This warranty does not apply to repair or replacement required
due to misuse, abuse, normal wear and tear or repairs attempted or made by other than our Service
Centers or Authorized Service Stations.
ANY IMPLIED WARRANTY, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE, WILL LAST ONLY FOR ONE (1) YEAR FROM THE DATE
OF PURCHASE.
To obtain information on warranty performance please write to: PORTER-CABLE CORPORATION,
4825 Highway 45 North, Jackson, Tennessee 38305; Attention: Product Service. THE FOREGOING
OBLIGATION IS PORTER-CABLE’S SOLE LIABILITY UNDER THIS OR ANY IMPLIED WARRANTY
AND UNDER NO CIRCUMSTANCES SHALL PORTER-CABLE BE LIABLE FOR ANY INCIDENTAL
OR CONSEQUENTIAL DAMAGES. Some states do not allow limitations on how long an implied
warranty lasts or the exclusion or limitation of incidental or consequential damages, so the above
limitation or exclusion may not apply to you.
This warranty gives you specific legal rights and you may also have other legal rights which vary
from state to state.
14
PORTER-CABLE • DELTA SERVICE CENTERS
(CENTROS DE SERVICIO DE PORTER-CABLE • DELTA)
(CENTRE DE SERVICE PORTER-CABLE • DELTA)
Parts and Repair Service for Porter-Cable
(Obtenga Refaccion de Partes o Servicio para su Herramienta en los Siguientes Centros de Porter-Cable
(Locations où vous trouverez les pièces de rechange nécessaires ainsi qu’un service d’entretien)
•
Delta Power Tools are Available at These Locations
•
Delta)
Cleveland 44125
ARIZONA
MICHIGAN
GEORGIA
8001 Sweet Valley Drive Unit #19
Phone: (216) 447-9030
Fax: (216) 447-3097
Phoenix 85013-2906
4501 N. 7th Ave.
Phone: (602) 279-6414
Fax: (602) 279-5470
Madison Heights 48071 (Detroit)
30475 Stephenson Highway
Phone: (248) 597-5000
Fax: (248) 597-5004
Forest Park 30297 (Atlanta)
5442 Frontage Road,
Suite 112
Phone: (404) 608-0006
Fax: (404) 608-1123
OREGON
Portland 97230
14811 North East Airport Way
Phone: (503) 255-6556
Fax: (503) 255-6543
MINNESOTA
CALIFORNIA
Eden Prairie 55344
9709 Valley View Road
Phone: (952) 884-9191
Fax: (952) 884-3750
Ontario 91761 (Los Angeles)
3949A East Guasti Road
Phone: (909) 390-5555
Fax: (909) 390-5554
ILLINOIS
Addison 60101 (Chicago)
400 South Rohlwing Rd.
Phone: (630) 424-8805
Fax: (630) 424-8895
PENNSYLVANIA
MISSOURI
St. Louis 63146
11477 Page Service Drive
Phone: (314) 997-9100
Fax: (314) 997-9183
Willow Grove 19090 (Philadelphia)
520 North York Road
Phone: (215) 658-1430
Fax: (215) 658-1433
San Diego 92111
Woodridge 60517 (Chicago)
2033 West 75th Street
Phone: (630) 910-9200
Fax: (630) 910-0360
7290 Clairemont Mesa Blvd.
Phone: (858) 279-2011
Fax: (858) 279-0362
TEXAS
San Leandro 94577 (Oakland)
3039 Teagarden Street
Phone: (510) 357-9762
Fax: (510) 357-7939
NEW YORK
Carrollton 75006 (Dallas)
1300 Interstate 35 N, Suite 112
Phone: (972) 446-2996
Fax: (972) 446-8157
Flushing 11365-1595 (N.Y.C.)
175-25 Horace Harding Expwy.
Phone: (718) 225-2040
Fax: (718) 423-9619
KANSAS
Overland Park 66214
9201 Quivira Road
Phone: (913) 495-4330
Fax: (913) 495-4378
COLORADO
Denver 80223
700 West Mississippi Ave.
Phone: (303) 922-8325
Fax: (303) 922-0245
Houston 77022-2122
536 East Tidwell Rd.
Phone: (713) 692-7111
Fax: (713) 692-1107
NORTH CAROLINA
Charlotte 28270
9129 Monroe Road, Suite 115
Phone: (704) 841-1176
Fax: (704) 708-4625
MARYLAND
Elkridge 21075 (Baltimore)
7397-102 Washington Blvd.
Phone: (410) 799-9394
Fax: (410) 799-9398
WASHINGTON
FLORIDA
Auburn 98001(Seattle)
3320 West Valley HWY, North
Building D, Suite 111
Phone: (253) 333-8353
Fax: (253) 333-9613
OHIO
Davie 33314 (Miami)
4343 South State Rd. 7 (441)
Unit #107
Phone: (954) 321-6635
Fax: (954) 321-6638
Columbus 43229
1948 Schrock Road
Phone: (614) 895-3112
Fax: (614) 895-3187
MASSACHUSETTS
Franklin 02038 (Boston)
Franklin Industrial Park
101E Constitution Blvd.
Phone: (508) 520-8802
Fax: (508) 528-8089
Tampa 33634
4909 West Waters Ave.
Phone: (813) 884-0434
Fax: (813) 888-5997
Authorized Service Stations are located in many large cities. Telephone 800-487-8665 or 731-541-6042 for assistance locating one. Parts and
accessories for Porter-Cable Delta products should be obtained by contacting any Porter-Cable Delta Distributor, Authorized Service
Center, or Porter-Cable Delta Factory Service Center. If you do not have access to any of these, call 888-848-5175 and you will be directed to
the nearest Porter-Cable Delta Factory Service Center. Las Estaciones de Servicio Autorizadas están ubicadas en muchas grandes ciudades.
Llame al 800-487-8665 ó al 731-541-6042 para obtener asistencia a fin de localizar una. Las piezas y los accesorios para los productos Porter-
Cable Delta deben obtenerse poniéndose en contacto con cualquier distribuidor Porter-Cable Delta, Centro de Servicio Autorizado o Centro
de Servicio de Fábrica Porter-Cable Delta. Si no tiene acceso a ninguna de estas opciones, llame al 888-848-5175 y le dirigirán al Centro de
Servicio de Fábrica Porter-Cable Delta más cercano. Des centres de service agréés sont situés dans beaucoup de grandes villes. Appelez au
800-487-8665 ou au 731-541-6042 pour obtenir de l’aide pour en repérer un. Pour obtenir des pièces et accessoires pour les produits Porter-
•
•
•
•
•
•
•
•
Cable
•
Delta, s’adresser à tout distributeur Porter-Cable
•
Delta, centre de service agréé ou centre de service d’usine Porter-Cable
•
Delta. Si
vous n’avez accès à aucun de ces centres, appeler le 888-848-5175 et on vous dirigera vers le centre de service d’usine Porter-Cable
•
Delta le
plus proche.
CANADIAN PORTER-CABLE • DELTA SERVICE CENTERS
QUÉBEC
ALBERTA
MANITOBA
1515 Ave.
Bay 6, 2520-23rd St. N.E.
Calgary, Alberta
T2E 8L2
1699 Dublin Avenue
Winnipeg, Manitoba
R3H 0H2
St-Jean Baptiste, Suite 160
Québec, P.Q.
G2E 5E2
Phone: (418) 877-7112
Fax: (418) 877-7123
Phone: (403) 735-6166
Fax: (403) 735-6144
Phone: (204) 633-9259
Fax: (204) 632-1976
BRITISH COLUMBIA
8520 Baxter Place
Burnaby, B.C.
V5A 4T8
Phone: (604) 420-0102
Fax: (604) 420-3522
ONTARIO
1447, Begin
St-Laurent, (Mtl), P.Q.
H4R 1V8
Phone: (514) 336-8772
Fax: (514) 336-3505
505 Southgate Drive
Guelph, Ontario
N1H 6M7
Phone: (519) 767-4132
Fax: (519) 767-4131
The following are trademarks of PORTER-CABLE
•
DELTA (Las siguientes son marcas registradas de PORTER-CABLE
•
DELTA S.A.) (Les
marques suivantes sont des marques de fabriquant de la PORTER-CABLE
•
DELTA): Auto-Set®, BAMMER®, B.O.S.S.®, Builder’s Saw®,
Contractor’s Saw®, Contractor’s Saw II™, Delta®, DELTACRAFT®, DELTAGRAM™, Delta Series 2000™, DURATRONIC™, Emc²™, FLEX®, Flying
Chips™, FRAME SAW®, Grip Vac™, Homecraft®, INNOVATION THAT WORKS®, Jet-Lock®, JETSTREAM®, ‘kickstand®, LASERLOC®, MICRO-
SET®, Micro-Set®, MIDI LATHE®, MORTEN™, NETWORK™, OMNIJIG®, POCKET CUTTER®, PORTA-BAND®, PORTA-PLANE®, PORTER-
CABLE®&(design), PORTER-CABLE®PROFESSIONAL POWER TOOLS, PORTER-CABLE REDEFINING PERFORMANCE™, Posi-Matic®, Q-
3®&(design), QUICKSAND®&(design), QUICKSET™, QUICKSET II®, QUICKSET PLUS™, RIPTIDE™&(design), SAFE GUARD II®, SAFE-LOC®,
Sanding Center®, SANDTRAP®&(design), SAW BOSS®, Sawbuck™, Sidekick®, SPEED-BLOC®, SPEEDMATIC®, SPEEDTRONIC®, STAIR EASE®,
The American Woodshop®&(design), The Lumber Company®&(design), THE PROFESSIONAL EDGE®, THE PROFESSIONAL SELECT®, THIN-
LINE™, TIGER®, TIGER CUB®, TIGER SAW®, TORQBUSTER®, TORQ-BUSTER®, TRU-MATCH™, TWIN-LITE®, UNIGUARD®, Unifence®,
UNIFEEDER™, Unihead®, Uniplane™, Unirip®, Unisaw®, Univise®, Versa-Feeder®, VERSA-PLANE® , WHISPER SERIES®,
WOODWORKER’S CHOICE™.
Trademarks noted with ™ and ® are registered in the United States Patent and Trademark Office and may also be registered in other countries.
Las Marcas Registradas con el signo de ™ y ® son registradas por la Oficina de Registros y Patentes de los Estados Unidos y también pueden
estar registradas en otros países. Marques déposées, indiquées par la lettre ™ et ®, sont déposées au Bureau des brevets d’invention et
marques déposées aux Etats-Unis et pourraient être déposées aux autres pays.
PC7.2-0105-164
|