Peerless Industries TV Mount IMC 18 User Manual

Model: IMC 18  
Installation and Assembly - CRT Ceiling Mount Kit for 14" - 17" Monitors  
IMPORTANT! Read entire instruction sheet before you  
start installation and assembly.  
WARNING  
• Installer must verify that the ceiling will safely support  
four times the combined weight of all attached equip-  
ment and hardware.  
IMPORTANT! This kit includes all mounting hardware  
for direct attachment to a wood joist ceiling. For  
concrete ceiling installations order accessory kit ACC  
210. Fixed Length and adjustable extension columns  
are also available.  
Before you start make sure all of the parts shown below are included with your product.  
E
A
H
F
G
I
C
D
B
U
PARTSLIST  
PART #  
QTY. DESCRIPTION  
J
A
B
C
D
E
F
530-9413  
540-9440  
520-9513  
520-9549  
540-9406  
540-9405  
4
4
4
6
8
6
5
2
2
1
1
1
1
1
1
1
2
1
1
1
4
1/4-20 nylock nut  
1/4 SAE flat washer  
1/4-20 x 3/4" carriage bolt  
5/16-18 socket head screw  
5/16 SAE flat washer  
5/16 lock washer  
M5 x .8 x 10 mm phillips screw  
5/16-18 x 3/4" hex head bolt  
5/16-18 nylock nut  
hanging bracket  
K
G 520-9250  
H
I
520-9210  
530-9306  
073-1007  
073-1008  
073-1001  
J
K
L
tilt bracket  
L
left adjuster  
M 073-1002  
073-1003  
O 073-1004  
128-1039  
Q 2PT-22CA01D  
right adjuster  
N
left tray  
M
right tray  
P
ceiling plate  
ceiling plate end cap  
flush mount tube  
retaining collar  
R
S
T
1446-014  
1800-375  
540-9432  
5S1-015-C03  
fiber washer  
O
U
#14 x 2.5" (6 mm x 65 mm)  
wood screw  
N
Note: Parts may not appear exactly as illustrated.  
R
Q
T
P
S
1 of 5  
ISSUED: 2-19-98 SHEET #: 073-9003-1 08-26-04  
For customer service call 1-800-729-0307 or 708-865-8870.  
 
WARNING  
• Installer must verify that the ceiling will safely support  
four times the combined weight of all attached equip-  
ment and hardware.  
5/16" (8 mm)  
For Concrete Ceilings drill four 5/16" (8 mm)  
dia. holes to a minimum depth of 1 3/4" (45  
mm). Attach ceiling plate (P) using concrete  
expansion anchors as shown (left and next  
page). Tighten to 80 in • lb (9 N.M.) maximum  
torque.  
Q
P
Snap end caps (Q) into place.  
concrete  
anchor  
Q
WARNING  
• Tighten concrete anchor bolts firmly, but do not  
overtighten. Overtightening can damage the bolts,  
greatly reducing their holding power.  
FOR PRODUCT SAFETY USE  
ONLY...  
RAWLTM #5005 OR HILTITM  
HL814 CONCRETE ANCHORS  
[.312 x 1.625 (8 mm x 41 mm)].  
ORDERACCESSORYFAS-  
TENER KIT #ACC 210  
• Never tighten in excess of 80 in • lb (9 N.M.).  
WARNING  
• Always attach concrete expansion anchors directly to  
load-bearing concrete.  
CONCRETE ANCHOR  
INSTALLATION  
Cross Section: Attachment  
to a concrete ceiling.  
• Never attach concrete expansion anchors to concrete  
covered with plaster, drywall or other finishing material.  
ceiling  
STEP1: Hammer STEP2: Tighten to 80 in • lb (9  
in concrete  
anchor.  
N.M.) maximum torque to  
expand anchors.  
CUTAWAYVIEW  
3 of 5  
ISSUED: 2-19-98 SHEET #: 073-9003-1 08-26-04  
For customer service call 1-800-729-0307 or 708-865-8870.  
 
First:Assemble bracket as shown.  
Leave all fasteners slightly loose to  
allow for adjustment.  
Second: From behind, insert  
monitor into bracket. Face of  
monitor should touch returns on  
left and right trays (N & O). Adjust  
height and width of bracket to fit  
snugly around monitor.  
Last: Tighten all fasteners!  
A
B
K
monitor  
L
M
C
N
E
F
return  
D
O
G
return  
4 of 5  
ISSUED: 2-19-98 SHEET #: 073-9003-1 08-26-04  
For customer service call 1-800-729-0307 or 708-865-8870.  
 
First: Choose tilt option (see "Tilt Options"  
below).  
Second: From inside, insert and tighten 5/16-  
18 x 3/4" hex bolts (H) to hanger bracket (J).  
Third:Attach hanger bracket using fiber  
washer (T) and retaining collar (S). Tighten  
retaining collar four or five complete turns.  
Last: Align one hole in the side of the retain-  
ing collar with slot. From inside insert and  
tighten one M5 x .8 x 10 mm phillips screw  
(G) to lock retaining collar (S).  
R
P
R
J
H
S
H
J
G
T
WARNING  
• For safety retaining collar must be locked with screw!  
S
Complete the assembly as shown.  
J
K
WARNING  
H
E
• Be sure to TIGHTENALL FASTENERS SECURELY!  
I
E
WARNING  
• Always use an assistant or mechanical lifting equip-  
ment to safely lift and position the TV or monitor.  
F
D
J
J
K
0O to 20O  
K
Tilt Option Two  
Tilt Option One  
Attach tilt bracket (K) to hanging  
bracket (J) as shown for a tilt  
range from 20O to 40O.  
Attach tilt bracket (K) to hanging  
bracket (J) as shown for a tilt range  
from 0O to 20O.  
5 of 5  
ISSUED: 2-19-98 SHEET #: 073-9003-1 08-26-04  
For customer service call 1-800-729-0307 or 708-865-8870.  
©2004PeerlessIndustries,Inc. Allrightsreserved.  
PeerlessisaregisteredtrademarkofPeerlessIndustries,Inc.  
 
Allotherbrandandproductnamesaretrademarksorregisteredtrademarksoftheirrespectiveowners.  

Peavey Stereo Amplifier Impulse 100P User Manual
Pelco Security Camera 2 C2481M 1 04 User Manual
Philips Baby Monitor SBC SC469 User Manual
Philips DVD VCR Combo 1VMN20587 User Manual
Philips Headphones SBC HL300U User Manual
Philips Home Safety Product SBCFL126 User Manual
Philips Microphone SBCMC8650 User Manual
Philips TV VCR Combo 14PV320 05 User Manual
Philips Universal Remote SBC RU 460 User Manual
PVI Industries Water Heater 250 N 400A TPL User Manual