Installation and Assembly:
SmartMount™ Universal Tilt Wall Mount
for 10" - 24" LCD Flat Panel Screens
Models: ST 630P, ST 630P-S, ST 630, ST 630-S
This product is intended for use with UL
Listed products and must be installed by a
qualified professional installer.
Features:
R
• Fits 10" to 24" LCD flat panel screens
• One-touch tilt for effortless positioning and adjustment of the screen
Max UL Load Capacity: 80 lb (36.3 kg)
3215 W. North Ave. • Melrose Park, IL 60160 • (800) 865-2112 or (708) 865-8870 • Fax: (708) 865-2941 • www.peerlessmounts.com
ISSUED: 04-27-05 SHEET #: 201-9421-10 10-27-09
Parts List
ST 630P
Qty Part #
ST 630P-S ST 630
ST 630-S
Part #
Description
Part #
Part #
adapter plate
tilt assembly
Alligator® anchor
M4 x 10 mm phillips screw
M4 x 20 mm phillips screw
retaining spacer
#14 x 2-1/2" hex head wood screw
M5 x 6 mm screw
1
1
2
4
4
4
2
1
1
095-1346
095-0359
590-0097
504-9012
504-9020
590-5005
095-4346
095-0360
590-0097
504-9012
504-9020
590-5005
095-1346
095-0359
590-0097
504-9012
504-9020
590-5005
095-4346
095-0360
590-0097
504-9012
504-9020
590-5005
A
B
C
D
E
F
G
H
I
5S1-015-C03 5S1-015-C03 5S1-015-C03 5S1-015-C03
520-1023
520-1023
520-1114
560-1133
520-1114
560-1133
security driver
A
B
C
D
E
F
G
H
I
ISSUED: 04-27-05 SHEET #: 201-9421-10 10-27-09
3 of 7
Installation to Single Wood Stud Wall
WARNING
• Make sure that the wall will safely support the combined load of the equipment and all attached hardware and
components.
Use a stud finder to locate the edges of the stud. Use of an edge-to-edge stud finder is highly recommended. Based
on its edges, draw a vertical line down the stud’s center. Place tilt assembly (B) on wall as a template, making sure
that the two mounting holes are over the stud centerline. Level tilt assembly, and mark the center of the two holes.
Drill two 5/32" (4 mm) dia. holes 2-1/2" (65 mm) deep. Make sure that the tilt assembly is level, secure it using two
#14 x 2-1/2" wood screws (G) as shown.
1
Skip to step 2 on page 6.
WARNING
• Tighten wood screws so that tilt assembly is firmly attached, but do not overtighten. Overtightening can damage the
screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud finder is
highly recommended.
• Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs. Installers
are responsible to provide hardware for other types of mounting situations.
B
G
ISSUED: 04-27-05 SHEET #: 201-9421-10 10-27-09
4 of 7
Installation to Solid Concrete or Cinder Block
WARNING
• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" of actual concrete
thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid
part of the block, generally 1" minimum from the side of the block. Cinder block must meet ASTM C-90 specifica-
tions. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to
avoid breaking out the back of the hole when entering a void or cavity.
• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Make sure that the wall will safely support the combined load of the equipment and all attached hardware and
components.
Make sure that tilt assembly (B) is level, use it as a
concrete
surface
1
template to mark two mounting holes. Drill two 1/4"
(6 mm) dia. holes to a minimum depth of 2-1/2"
(64 mm). Insert anchors (C) in holes flush with wall
as shown (right). Place tilt assembly over anchors
and secure with two #14 x 2-1/2" screws (G). Level,
then tighten all fasteners.
1
C
Drill holes and insert anchors (C).
2
WARNING
B
• Tighten screws so that wall plate is firmly attached,
but do not overtighten. Overtightening can damage
screws, greatly reducing their holding power.
C
G
• Never tighten in excess of 80 in. • lb (9 N.M.).
Place assembly (B) over anchors (C) and secure with screws (G).
3
WARNING
• Always attach concrete expansion anchors directly to
load-bearing concrete.
• Never attach concrete expansion anchors to concrete
covered with plaster, drywall, or other finishing mate-
rial. If mounting to concrete surfaces covered with a
finishing surface is unavoidable, the finishing surface
must be counterbored as shown below. Be sure
concrete anchors do not pull away from concrete
when tightening screws. If plaster/drywall is thicker
than 5/8", custom fasteners must be supplied by
installer.
Tighten all fasteners.
C
CORRECT
INCORRECT
B
wall plate
concrete
concrete
wall
plate
plaster/
drywall
plaster/
drywall
G
ISSUED: 04-27-05 SHEET #: 201-9421-10 10-27-09
5 of 7
Attaching Adapter Plate to Flat Panel Screen
WARNING
• If screws don't get three complete turns in the screen inserts or if screws bottom out and bracket is still not tightly
secured, damage may occur to screen or product may fail.
FORVESA® 75MOUNTINGPATTERN:
FORVESA100MOUNTINGPATTERN:
2
Choose hole pattern as shown below. Attach adapter
plate (A) to back of screen using four M4 x 10 mm
screws (D) as shown below.
Choose hole pattern as shown below. Attach adapter
plate (A) to back of screen using four M4 x 10 mm
screws (D) as shown below.
*Note: If hole pattern is in a pocket, attach adapter
plate (A) to back of screen using four M4 x 20 mm
screws (E) and four retaining spacers (F) as indicated
below.
A
D
A
D
*For screens with a hole
pattern in a pocket,
spacers (F) go between
adapter plate (A) and
screen.
F
ISSUED: 04-27-05 SHEET #: 201-9421-10 10-27-09
6 of 7
Installing and Removing Flat Panel Screen
Attach screen to tilt assembly (B). Tighten M5 x 6
mm screw (H) to lock screen to tilt assembly.
3
SCREEN
Note: For security models, use security driver (I) to
tighten M5 x 6 mm screws (H).
H
To remove screen from mount, loosen screw (H) and
lift screen off of mount.
A
WARNING
• Do not lift more weight than you can handle. Use
additional man power or mechanical lifting equipment
to safely handle placement of the screen.
• Failure to lock adapter plate (A) with screw (H) can
cause screen to come off mount if hit accidentally.
B
CAUTION
• Do not tighten screws with excessive force.
Overtightening can cause damage to mount. Tighten
screws to 20 in. • lb (2.26 N.M.) maximum torque.
fig. 3
Adjusting the Tilt Angle of the Flat Panel Screen
Adjust tension knob on right side of mount shown in
figure 4 to desired tension to balance your screen
size and weight.
4
Note: If knob is inaccessible, remove screen from
mount, adjust tension knob to desired tension to
balance your screen size and weight, and reattach
screen to mount as stated in step 3.
Push or pull from top or bottom of screen to adjust
tilt as shown in figure 4. The tilt can be adjusted to a
maximum of 15° forward or 5° backward.
TENSION KNOB
CAUTION
• Do not tighten screws with excessive force.
Overtightening can cause damage to mount. Tighten
screws to 40 in. • lb (4.5 N.M.) maximum torque.
CAUTION
• Be careful not to pinch fingers when pushing screen
from the bottom.
fig. 4
ISSUED: 04-27-05 SHEET #: 201-9421-10 10-27-09
7 of 7
©2007, PeerlessIndustries, Inc. Allrightsreserved.
Allotherbrandandproductnamesaretrademarksorregisteredtrademarksoftheirrespectiveowners.
|