1.4 SERVICE INFORMATION
1.2 RADIO AND TV INTERFERENCE
All warranty and non-warranty repairs must be returned freight
prepaid and insured to Patton Electronics. All returns must have a
Return Materials Authorization number on the outside of the shipping
container. This number may be obtained from Patton Electronics
Technical Support at:
The Models IM1/K and IM2RC/K (K Module) generate and use
radio frequency energy, and if not installed and used properly—that is,
in strict accordance with the manufacturer's instructions—may cause
interference to radio and television reception. If the K Module does
cause interference to radio or television reception, which can be deter-
mined by disconnecting the cables, the user is encouraged to try to
correct the interference by one or more of the following measures:
moving the computing equipment away from the receiver, re-orienting
the receiving antenna, and/or plugging the receiving equipment into a
different AC outlet (such that the computing equipment and receiver
are on different branches).
tel: (301) 975-1007
email: [email protected]
NOTE: Packages received without an RMA number will not be
accepted.
1.3 CE AND TELECOMMUNICATION APPROVALS
Patton Electronics' technical staff is also available to answer any
questions that might arise concerning the installation or use of your
Patton K Module. Technical Support hours: 8AM to 5PM EST,
Monday through Friday.
The CE symbol on your Patton Electronics equipment indicates
that it is in compliance with the Electromagnetic Compatibility (EMC)
directive and the Low Voltage Directive (LVD) of the Union European
(EU). A Certificate of Compliance is available by contacting Technical
Support.
The K Module is in compliance with the Telecommunication techni-
cal requirements CTR-12; 2.048 Mbps digital unstructured leased line
(D2048U) attachment requirements for terminal equipment
interface.
The K Module also meets the Telecommunication technical
requirements CTR-13; 2.048 Mbps digital structured leased lines
(D2048S) attachment requirements for terminal equipment interface.
4
3
2.0 GENERAL INFORMATION
3.0 TYPICAL APPLICATION
Thank you for your purchase of this Patton Electronics product.
This product has been thoroughly inspected and tested and is warrant-
ed for One Year parts and labor. If any questions arise during installa-
tion or use of the unit, contact Patton Electronics Technical Support at
(301) 975-1007.
The K Module can be deployed in one of two applications:
G.703/G.704 Network Termination (nx64kpbs to 2.048Mbps), and
G.703/G.704 Network Extension (nx64 kbps to 2.048Mbps). Both appli-
cations are discussed below.
2.1 FEATURES
3.1 NETWORK TERMINATION APPLICATION
• Quick Connect and Rear Card Modules for use with Patton
mDSL modems
• nx64 G.703/G.704 Network Termination or Network
Extension Applications
Network Termination mode is used to connect a local site
modem employing a K Module to a remote site modem employing
a V.35, X.21, RS-530 Ethernet QuikConnect Module (refer to
Figure 1, below). Transmitter clocking is derived from the
G.703/G.704 network and carried through the system to all system
devices.
• Supports rates up to 2.048 (E1) Mbps
• 2.048Mbps G.703 Clear Channel (Unframed) or nx64 G.704
(Framed) Operation
• Selectable AMI or HDB3 Line Coding
• Configuration via DIP Switches and Jumpers
• Coax (BNC) connection for 75 ohm
• RJ-48C connection via twisted pair for 120 ohm
• Made in USA
K Module and
mDSL Modem
mDSL Modem with
Serial Interface
nx64kbps
G.703/G.704
Network
Receive
Recover
Clocking
V.35
Router
External
Clocking
Cable Span
Clock/
Data
Clock/
Data
2.2 GENERAL PRODUCT DESCRIPTION
Data
Clock/
Data
The Patton Model IM1/K G.703/G.704 QuickConnect Module and
IM2RC/K Rear Card Module provide E1/Fractional E1 termination and
extension capabilities to the Patton NetLink mDSL modems
(1095/1095RC). When used with a Patton mDSL modem, a
G.703/G.704 line can be terminated or extended to a remote site up to
10km away.
1095
(1095RC)
V.35 Module
K Module
1095
(1095RC)
Figure 1. Clocking Settings in a Network Termination Application
There are two separate applications that can be employed
when using the K Modules; Network Termination or Network Extension.
In a Network Termination application, the G.703/G.704 line is terminat-
ed at the K Module and the clock and data is sent to the far end of the
link. At the remote site, a Patton mDSL modem with a serial/Ethernet
interface will be running the nx64 DTE rate. This application allows the
remote user without a G.703/G.704 interface to extend the serial inter-
face that is available to the G.703/G.704 access point without the need
for a separate G.703/G.704 to serial converter. In the G.703/G.704
Network Extension application, two K Modules are employed, one at
each end of the link. This application allows the user to extend the
G.703/G.704 network over 10km away.
The K Module supports switch selectable AMI or HDB3 encoding,
all nx64 kbps bit rates and both dual coaxial (75 ohm) and RJ-48C
(120 ohm) G.703/G.704 terminations. The K Module is made in the
USA. The K Module is CE marked and complies to applicable CTR
standards.
6
5
3.2 NETWORK EXTENSION APPLICATION
4.0 CONFIGURATION
Network Extension mode is used to extend nx64 -2.048Mbps
G.703/G.704 service across a DSL link, providing an nx64
G.703/G.704 link at the remote site. Transmitter clocking is
derived from the G.703/G.704 network, and transmitted over the
baseband modem link (refer to Figure 2, below).
The K Module features configuration capability via hardware
switches and jumpers. Sections 4.1 and 4.2 describe all switch and
jumper configurations for the Patton K Module. Section 4.3 describes
the configuration required for your mDSL modem.
4.1 DIP Switch Configuration
K Module and
mDSL Modem
K Module and
mDSL Modem
The K Module has eight internal DIP switches (S1-1 through S1-8).
The DIP switches can be configured as either “On” or “Off.” See
Appendix D for location and orientation of the DIP switches.
nx64kbps
G.703/G.704
CPE
External
Clocking
set to Force CP
nx64kbps
G.703/G.704
Network
External
Clocking
Cable Span
Clock/
Data
Clock/
Data
Clock/
Data
Switch S1-1: Line Coding
Clock/
Data
Use Switch S1-1 to control the Network Line Coding options. Set
these options to be the same as the Line Coding that has been provid-
ed by your Service Provider.
1095
(1095RC)
K Module
K Module
1095
(1095RC)
S1-1
Off
On
Line Framing & Coding
HDB3
AMI
Figure 2. Clock Settings in a Network Extension Application
Line Coding Options:
High Density Bipolar 3 (HDB3): In HDB3 coding, the transmitter
deliberately inserts a bipolar violation when excessive zeros in the
data stream are detected. The receiver recognizes these special
violations and decodes them as zeros. This method enables the
network to meet minimum pulse density requirements. Use HDB3
unless AMI is required in your application .
Alternate Mark Inversion (AMI): AMI coding does not inherently
account for ones density. To meet this requirement, you should
ensure that the data inherently meets pulse density requirements.
Switch S1-2 : CRC-4 Multiframe
CRC-4 Multiframe uses Time Slot zero to carry CRC-4 information.
When CRC-4 is enabled (ON), the unit synchronizes to the CRC-4
multi-frame protocol.
S1-2
Off
On
Option
Disabled
Enabled
NOTE: When the data rate is set to 2048 Kbps, K Module trans-
mits user data on all 32 timeslots, ignoring framing information. In
this case, Switch S1-2 will be ignored.
7
8
Switch S1-3 : Clear Channel Mode
Clock Mode
The mDSL modem must be set for the External Clock mode when
When S1-3 is at Off position, the K Module is running in G.703
clear channel mode. When S1-3 is at On position, the K Module is run-
ning in G.704 framed mode. When the K Module is set to framed
mode, channel 0 will be used to pass G.704 framing information which
results in a maximum bandwidth of 1984kbps for user data.
a K Module is installed. The modem will always receive the clocking
from the K Module. If you are configuring a Network Extension applica-
tion, set both modems for External Clock mode. If you are configuring
a Network Termination application, please set the modem with the K
Module for External Clock and the unit with the serial/Ethernet inter-
face for Receive Recovered clock mode. In order to determine the
switch settings specific to your unit, refer to the mDSL manual that was
shipped with your unit.
S1-3
Off
On
Option
Clear Channel Mode (G.703)
Framed Mode (G.704)
Switch S1-4 Through S1-8 : Reserved
CO-CP
Reserved for future use and should be set to OFF.
The CO/CP selection tells the units which modem will begin the
handshaking for the link. In all applications one unit must be set for CO
and one unit must be set for CP, they work in pairs. A mDSL modem
set for either Internal or External clock mode will automatically default
to the CO mode. A mDSL modem set for Receive Recovered clock
mode will automatically default to the CP mode. If you are configuring
a Network Extension application, you must force one of the units to
CP mode by setting S2-1 on the mDSL modem to the ON position.
Note that the mDSL manual refers to this switch as "Reserved". If you
are running in the Network Termination mode, no extra configuration is
required.
4.2 Jumper Configuration
The Patton K Module has four jumpers (two position headers):
JP4, JP5, JP6, and JP7. These jumpers are used to select input and
output impedance matching between the module and external line. See
Appendix E for jumper locations.
The following is a description of the jumper settings with respect
to the front panel connectors.
1. For a 75 ohm connection (coax) install JP4 - JP7 (default).
Interface Type
2. For a 120 ohm connection (RJ-48C) remove JP4 - JP7.
The mDSL modem requires that the interface type is specified.
Any unit that has a K Module installed must be set to G.703/G.704
Interface. This is done by setting S2-5 on the mDSL modem to ON.
Note that the mDSL manual refers to this switch as "Reserved".
4.3 Configuring Your Model 1095 mDSL Modem
DTE Rate for the mDSL Modems
This section describes how to configure your mDSL modem for
use with an IM1/K (Model 1095) or an IM2RC/K (Model 1095RC).
To select the number of G.703/G.704 channels to be carried
across the link, multiply the number of required channels by 64Kbps
and then set the DTE rate of the mDSL modem to that number. The
mDSL modem will then carry that number of channels from the
G.703/G.704 line, starting with channel 1 (Note channel 0 is used for
G.704 framing information) across the DSL link. For example, if you
want to carry 4 channels across the DSL link, set the mDSL DTE Rate
to 256Kbps (4 x 64Kbps = 256Kbps). The mDSL modem and the K
Module will then carry channels 1 - 4 across the DSL link.
The K Module requires the 1095/1095RC to have software ver-
sion 2.3.2 or later, which began shipping on 04/01/00.
If you are unsure of the software revision of your unit, please con-
tact Patton Electronics Technical Support.
If you are running in clear channel mode, set switch S1-3 on the K
Module to "clear channel" and set the DTE Rate of your mDSL modem
to 2048Kbps.
9
10
Installing the New QuikConnect™ Module
5.0 INSTALLATION
1) Make sure the power switch is off. Leave the power cord
plugged into a grounded outlet to keep the unit grounded.
2) Hold the module with the faceplate toward you and align the
module with the guide slots in the rear panel of the NetLink
Chassis.
3) While keeping the module’s faceplate parallel with the NetLink
chassis rear panel, slide the module straight in – so that the
card edge contacts line up with the socket inside the chassis.
4) With the card edge contacts aligned with the socket, firmly seat
the module by using your thumbs to apply pressure directly to
the right and left edges of the module faceplate. Applying mod-
erate and even pressure should be sufficient to seat the mod-
ule. You should hear it “click” into place.
This section describes how to install the IM1/K and IM2RC/K mod-
ules into your mDSL modems. Please refer to the section in this manu-
al that describes your unit.
5.1 Installing the IM1/K
The QuickConnect™ interface on the NetLink Modems are inter-
changeable Modules. Each QuikConnect™ Module has a 50-pin card
edge connector on one side and a Network interface on the other.
Figure 3 below shows how a QuikConnect™ Module plugs into the
back of the Model 1095.
5) To secure the module in place, push the thumbscrews into the
chassis and turn the screws clockwise to tighten.
5.2 Installing the IM2RC/K and Front Fuction Card
The Model IM2RC/K is a rear-mountable G.703/G.704 interface
card that works with the Patton Model 1095RC function card. The two
cards meet inside the rack chassis and plug into each other by way of
mating 50 pin card edge connectors. Use the following steps as a
guideline for installing each Model IM2RC/K and its function card mate
into the rack chassis:
1. Slide the rear card into the back of the chassis along the
metal rails provided.
Figure 3. Installation of Model 1095 Plug-in K Module
2. Secure the rear card using the metal screws provided.
3. Slide the front card into the front of the chassis. It should
meet the rear card when it’s almost all the way into the chas-
sis.
4. Push the front card gently into the card-edge receptacle of the
rear card. It should “click” into place.
5.1.1 Changing QuikConnect™ Modules
When you purchase a NetLink™ mDSL modem, it should be
shipped to you with the appropriate QuikConnect™ Module already
installed. If you need to install a different QuikConnect™ Module, fol-
low these steps:
5. Secure the front card using the thumb screws.
Removing the Existing QuikConnect™ Module
The IM2RC/K is shipped with an IM1RC/K flip card. Ensure that
the flip card is secured in the flip card socket on the 1095RC with the
1) Turn the power switch off. Leave the power cord plugged into
a grounded outlet to keep the unit grounded.
2) Loosen the two thumbscrews on the module by turning them
counterclockwise.
arrow (
) pointing toward the front panel. Please see the Model
1095RC User Manual (section 3.0 Configuration), for more informa-
tion on installing the flip card.
3) Grasp the two thumbscrews and gently pull the module from
the unit. Apply equal force to the thumbscrews to keep the
module straight during the removal process
12
11
5.3 MAKING INTERFACE CONNECTIONS
RJ-48C Cable (8-Wire)
The Patton K Module may be connected to G.703/G.704 ports
using a single 120 ohm RJ-48C or a dual 75 ohm coax (BNC). The
Patton K Module rear panels and the location of these connectors are
show below in Figure 4.
K Module
SIGNAL
G.703/G.704
NETWORK SIGNAL
PIN#
RX+
RX-
1-----------------------TX+
2-----------------------TX-
Network
TX+
TX-
5-----------------------RX+
4-----------------------RX
Shield
Shield
3-----------------------Shield
6-----------------------Shield
RX
TX
5.3.2 Connect Dual Coaxial Cable (75 ohm) to G.703/G.704 Network
The Patton K Module is also equipped with dual female BNCs (TX
and RX) for connection to a 75 ohm dual coax G.703/G.704 network
interface. If your G.703/G.704 network terminates via dual coaxial
cable, use the diagram below to make the proper connections. The
connector pinout and signals are shown in Figure 6, below.
TX
RX
Network
Figure 4: K Module Rear Panels, Showing Location of Connectors
RX
TX
TX
RX
5.3.1 Connect Twisted Pair (120 ohm) to G.703/G.704 Network
(Data FROM
G.703/G.704
Network)
(Data TO
G.703/G.704
Network)
The Patton K Module is equipped with a single RJ-48C jack for
connections to a 120 ohm twisted pair G.703/G.704 network interface.
If your G.703/G.704 network terminates via RJ-48C, use the diagram
below and the table on the following page to make the proper connec-
tions. The connector pinout and signals are shown in Figure 5, below.
Use the following connection diagram to connect the 120 ohm
G.703/G.704 network channel.
TX
RX
(No Connection) 8
(No Connection) 7
(No Connection) 6
(TX+) 5
(TX-) 4
(No Connection) 3
(RX-) 2
8
7
6
5
4
3
2
1
Figure 6: 75 ohm Dual Coaxial G.703 Interface
NOTE: The outer conductor of the coax cables are isolated
from system earth ground.
(RX+) 1
Figure 5: 120 ohm RJ-48C G.703/G.704 Interface
13
14
6.0 OPERATION
APPENDIX A
Once the Patton K Module is installed and configured, it should
operate transparently. Please refer to the base unit (i.e. Model 1095)
user manual for instructions on how to read the front panel LEDs, per-
form diagnostics, monitor system status, and connect to the DSL line
port.
PATTON ELECTRONICS MODEL K MODULE
SPECIFICATIONS
G.703/G.704 Interfaces: Female Dual Coaxial 75 ohm
Female RJ-48C 120 ohm
Line Framing:
Line Coding:
Clock Options:
G.703 (unframed) or G.704 (framed)
Switch Selectable AMI or HDB3
Network Termination and Network
Extension
DTE Rates:
(selected on the base unit)
Nx64 rates (kbps): 64, 128, 192, 256, 320,
384, 448, 512, 576, 640, 704, 768, 832,
896, 960, 1024, 1088, 1216, 1280, 1344,
1408, 1472, 1536, 1600, 1664, 1728, 1792,
1856, 1920, 1984, 2048
Distance:
Maximum 1.6 km on 24 AWG Cable
Isolation:
1500 Vrms
Power Supply:
Power Supplied via NetLink Standalone Unit
or NetLink front card
Compliance:
Dimensions:
CE Mark per EMC Directive 89/336/EEC
and Low Voltage Directive 73/23/EEC,
RTTE 99/5/EC Directive
6.17 x 1.42 x 7.42 cm (2.43 x .56 x 2.92
inches)
Humidity:
Up to 95% non-condensing
32 to 140º F (0 to 60º C)
Temperature:
16
15
APPENDIX C
APPENDIX B
K MODULE
PATTON K MODULE
FACTORY REPLACEMENT PARTS
AND ACCESSORIES
CABLE RECOMMENDATIONS
Patton Electronics Model #
Description
All Patton Electronics Company Baseband Modems, CSU/DSUs
and Short Range Modem are tested to the distances published in our
Catalogs and Specification Sheets on twisted-pair cable with the fol-
lowing characteristics:
07MIM1/K Module...........K Module User Manual
IM1/K Module..................K Module for use with Model 1095
IM2RC/K Module.............K Module for use with Model 1095RC
IM1RC/K Module.............K Module flip card
Wire Gauge
Capacitance
Resistance
19 AWG
22 AWG
24 AWG
26 AWG
83nF/mi or 15.72 pF/ft.
83nF/mi or 15.72 pF/ft.
83nF/mi or 15.72 pF/ft.
83nF/mi or 15.72 pF/ft.
.0163 ohms/ft.
.0326 ohms/ft.
.05165 ohms/ft.
.08235 ohms/ft.
We fully expect that the Baseband Modems, CSU/DSUs and Short
Range Modems will operate on lines with specifications different from
those tested, but to reduce the potential difficulties in the field, one
should ensure that the cable being used has similar or better charac-
teristics (lower capacitance or lower resistance).
Wire with capacitance of 20pF/ft. or less is suitable for all
Baseband Modems, CSU/DSUs and Short Range Modems. However,
distances may vary from those published in our catalog. Resistance
will also affect distance but not functionality. Wire should be 26 AWG
or larger (smaller AWG#).
Patton products are designed to withstand normal environmental
noise and conditions; however, other environmental factors too numer-
ous to discuss in this format may affect proper operation.
Selection of the proper Baseband Modem, CSU/DSU or SRM for
an application is critical to maintaining Customer Satisfaction and must
be taken seriously. Certain models are better suited for particular
applications and environments than others.
18
17
APPENDIX E
APPENDIX D
PATTON K MODULE
DIP SWITCHES
PATTON K MODULE JUMPER SETTINGS
Figure A (below) shows the location of the DIP switches on top of
the printed circuit board. Following Figure A, Figure B shows the ori-
entation of the DIP switches on the printed circuit board.
Figure C (below) shows the top view of the IM1/K printed circuit
board (PCB) and the location of the jumpers.
Interface Panel
Interface Panel
JP5
JP4
JP5
JP4
DIP Switches
JP7
JP6
JP7
JP3
JP6
JP1
JP3
JP1
ON
OFF
ON
OFF
Edge Connectors
Front Panel
Figure A. IM1/K top view, showing location of DIP switches
Edge Connectors
Figure C. K Module, top view, showing location of jumpers
DIP Switches
Figure D (below) shows the top view of the IM2RC/K printed circuit
board (PCB) and the location of the jumpers.
OFF
ON
1
2
3
4
5
6
7
8
Rear
O N
DIP Switches
OFF
ON
1
2
3
4
5
6
7
8
Front
Panel
Rear
O N
JP5
JP4
JP6
JP7
JP9
Figure B. IM2RC/K, top view, showing location of DIP switches
JP3
Figure D. IM2RC/K, top view, showing location of jumpers