Omron Blood Pressure Monitor 11 675D User Manual

INSTRUCTION MANUAL  
LARGE FACE  
SPHYGMOMANOMETER  
Models 11-675D and 11-675DNL  
11-685 and 11-685NL  
160  
140  
180  
300  
120  
100  
80  
60  
220  
240  
240  
260  
280  
160  
140  
180  
120  
100  
80  
60  
220  
240  
240  
260  
280  
SPHYGMOMANOMETER  
RT  
C
E
I
F
I
E
D
40  
20  
mmHg  
M
A
D
E
I
N
J
A
PA  
N
SPHYGMOMANOMETER  
CERTIFIED  
40  
20  
300  
mmHg  
M
A
D
E
I
N
J
A
PA  
N
 
COMPONENTS  
ASSEMBLY INSTRUCTIONS  
Models:  
Cuff/Bladder  
11-675D  
11-675DNL  
11-685  
Square Face, Wall Mount  
Square Face, Wall Mount, LATEX-FREE  
Square Face, Floor Stand  
Figure1  
Sphygmomanometer  
160  
140  
180  
120  
100  
80  
60  
220  
240  
240  
260  
280  
11-685NL  
Square Face, Floor Stand, LATEX-FREE  
SPHYGMOMNOMETER  
CERTIIED  
40  
20  
300  
mmHg  
M
A
D
E
I
N
J
A
PA  
N
Omron Clock Aneroid (all models):  
(1)  
(1)  
(1)  
(1)  
Omron Clock Aneroid (see Models for type)  
Adult, Nylon Cuff, blue (model #21-071)  
8’ Coiled Tube  
Adult, Two-Tube Bladder (model #21-081 Latex, #21-081NL Latex-Free)  
Inflation Bulb with Deluxe Air Release Valve (model #21-141 Latex,  
#21-125NL Latex-Free, #21-131 Valve)  
Coiled Tube, 2.4meter (8ft.) length (model #21-321 Latex,  
#21-321NL Latex-Free)  
Deluxe Air  
Release Valve  
(1)  
Inflation Bulb  
Black Knob  
(1)  
(1)  
Set of metal luer connectors (model #21-331S)  
Calibration tool  
Chrome-plated poles  
Wall-Mount Kit (for models 11-675D and 11-675DNL):  
(1)  
(1)  
(4)  
(4)  
Wall-Mount Bracket  
Wall-Mount Plate  
Metal Wall Anchors  
Metal Screws  
Floor Stand Kit (for models 11-685 and 11-685NL)  
(1)  
(5)  
(2)  
(1)  
(1)  
(1)  
(1)  
(1)  
Five-legged base  
Wheel assemblies  
Chrome-plated poles  
Black Knob  
Large Washer  
Large Hex Bolt  
Small Washer  
Five-Legged Base  
Large Washer  
Wheel Assembly  
Round-head bolt (spare)  
Small Washer  
Large Hex Bolt  
3
2
 
ASSEMBLY INSTRUCTIONS  
ASSEMBLY INSTRUCTIONS  
Omron Clock Aneroid (all models):  
Cuff  
1. Attach one end of the coiled tube (the end without the metal connector)  
to the connector on the underside of the Omron Aneroid (Figure 2).  
2. Attach the other end of the coiled tube (the end with  
the metal connector) to the tube from the cuff and bladder  
(the tube without the bulb assembly).  
Figure 5  
160  
140  
180  
3. The cuff and bladder assembly can be stored in the  
basket on the back of the aneroid. Once mounted  
to the wall or affixed to a floor stand, the Omron  
Aneroid is ready for use.  
120  
100  
80  
60  
220  
240  
240  
260  
280  
SPHYGMOMANOMETER  
CERTFIED  
40  
Connector  
20  
300  
mmHg  
MADE IN JAPAN  
Figure 2  
Wall-Mount (for models 11-675D and 11-675DNL):  
Coiled Tube  
1. Hold wall-mount plate against the wall at the desired location and  
mark the position of the mounting holes for drilling. Drill four (4) holes  
and insert the metal wall anchors. Attach the wall-mount plate to the wall  
by using the four metal (4) screws (Figure 3).  
2. Loosen wing nut on the bottom of the Aneroid and adjust the unit  
to the desired angle. Tighten wing nut and slide the wall bracket  
into the wall-mount plate (Figure 4).  
Figure 4  
3. The wall-mounted Omron Aneroid  
is now ready for use.  
Air Release Valve  
Bulb  
Figure 3  
4
5
 
ASSEMBLY INSTRUCTIONS  
Floor Stand Kit (for models 11-685 and 11-685NL)  
ASSEMBLY INSTRUCTIONS  
Figure 6  
Figure 7  
Sphygmomanometer  
1. Insert each of the five (5) wheel casters into each of the five (5) legs  
of the five-legged base (Figure 6).  
160  
140  
180  
120  
100  
80  
60  
220  
240  
240  
260  
280  
2. Insert the larger diameter chrome plated pole into the top of the  
five-legged base.  
SPHYGMOMNOMETER  
CERTIIED  
40  
20  
300  
mmHg  
M
A
D
E
I
N
J
A
PA  
N
3. Insert the large hex-bolt, the large washer, and one small washer from  
the bottom center of the five-legged base into the bottom center  
of the larger diameter chrome plated pole. Securely tighten the hex bolt.  
4. Insert the smaller diameter chrome plated pole into the top of the larger  
diameter pole. Insert the black knob into the top of the larger diameter  
pole. Set the smaller diameter pole to the desired height and tighten  
the black knob.  
Small Diameter  
Chrome-Plated Pole  
5. The floor stand is now complete. To attach the Omron Aneroid to the floor  
stand, begin by removing the wing nut connecting the aneroid to the  
wall-mount bracket (Figure 7).  
Black Knob  
6. Insert the small hex nut from the Omron Aneroid and one small washer  
from the top of the hole where the wing nut was removed.  
Large Diameter  
Chrome-Plated Pole  
7. While holding the aneroid and small hex nut assembly in one hand, insert  
the small hex nut into the top of the smaller diameter chrome plated pole.  
Turn the pole counter-clockwise to attach both assemblies.  
Securely tighten the assembly.  
8. The floor-mounted Omron Aneroid is now ready for use.  
Five-Legged Base  
Large Washer  
On-Site Calibration:  
1. Remove the coiled tube from the connector on the underside  
of the aneroid.  
Wheel Casters  
2. Insert the calibration tool (or small flat-head screw driver) into the connector  
(from where the coiled tube was removed).  
3. Turn the calibration tool until the needle on the front of the gauge is centered  
at the bottom of the gauge.  
Small Washer  
Large Hex Bolt  
6
7
 

Miele Washer W3203 User Manual
MTD Chipper 242 640 000 User Manual
Napoleon Grills Gas Grill BGNV42N User Manual
Nokia Network Router CC100 User Manual
Nortel Networks Network Router 5000i User Manual
NuTone Ventilation Hood QT130 User Manual
Optoma Technology Projector EP729 User Manual
Palsonic Digital Photo Frame DPF8128 User Manual
Panasonic Network Card AW DU600P User Manual
ParaBody Home Gym 445104 User Manual