Omnitron Systems Technology Network Card 10FL T User Manual

In Remote Fault Detection (RFD), the UTP port  
transmits a Link signal only when receiving a Link at the  
fiber port. The fiber port transmits a Link only when  
receiving Link signals both at the fiber port and the UTP  
port. As a result, fiber faults (no “Link” received at the  
fiber) are looped-back and can be reported to the network’s  
core [Fig 1(c)].  
2. Attach the UTP port to a 10BASE-T Ethernet device  
using a Category 5 cable. If the attached device  
features 10/100 or 10/100/1000 Auto-Negotiation,  
disable this feature and manually set the UTP port  
speed of the connected device to 10Mbps.  
ABOUT THIS MANUAL:  
FRONT PANEL DIP-SWITCH SETTINGS:  
This document supports revision “xx/20” of the  
iConverter 10FL/T. Please refer to the serial number  
label on the ROM chip of the 10FL/T for the revision  
number of your product. This revision incorporates the  
following improvements to the 10FL/T.  
iConverter 10FL/T User Manual  
Fig. 2 DIP-Switches  
3. Using a multimode or single-mode dual-fiber cable as  
required per the converter type, attach the fiber port  
to a 10BASE-FL mating Ethernet device. The transmit  
(Tx) must attach to the receive side of the mating  
device and the receive (Rx) must attach to the  
transmit side.  
REMOTE FAULT DETECT “R/FLT DET” DIP-SWITCH:  
1. Link Propagate is the default link mode.  
When the Remote Fault Detect DIP-Switch is in the  
“R/Flt Det” position, the Remote Fault Detect mode is  
enabled. When in the “Norm” (factory setting) position,  
Remote Fault Detect is disabled and Link Propagate is  
enabled.  
LP  
LP  
OVERVIEW:  
Fiber  
The iConverter 10FL/T converters support the IEEE 802.3  
Ethernet standard and convert 10BASE-T unshielded  
twisted pair (UTP) to 10BASE-FL fiber optic cabling. Mod-  
els are available for multimode (MM) and single-mode  
(SM) dual fiber and single-mode single-fiber.  
UTP  
UTP  
Fiber  
4. Single-fiber (SF) converters must be used in matched  
pairs. The transmit (Tx) and receive (Rx) wavelengths  
of one converter must match the receive (Rx) and  
transmit (Tx) wavelengths of the mating converter.  
For example, an 8310-1 must be connected to an  
8311-1.  
iConverter 10FL/T Dual Fiber Modules  
Note that connecting two converters when both are  
set to RFD mode is illegal and will cause a “deadly  
embrace” lockup.  
Switch 1 Converter A  
LP  
Converter B Switch 2  
LP  
Connector Type  
Fiber Type  
Distance  
The 10FL/T supports Half-Duplex and Full-Duplex modes  
and features a crossover UTP switch for easy  
attachment to hubs, switches and workstations.  
ST  
8300-0 8302-0  
8300-1  
SC  
MT-RJ  
LC  
RJ45 Crossover “X / =” Switch (Not Shown):  
MM  
MM  
SM  
SM  
SM  
2 km  
5 km  
-
-
-
When connecting the UTP port to a hub or switch, set  
switch to Straight-Through “=” (factory setting). When  
connecting to a workstation, set it to Crossover “X”.  
-
8304-1  
The 10FL/T can be used in an unmanaged or managed  
fashion. When unmanaged, the 10FL/T can be installed  
in a chassis without a Network Management Module (NMM).  
To be managed, a NMM module must be installed in the  
same chassis.  
30 km  
60 km  
120 km  
8301-1 8303-1 8305-1 8307-1  
Switch 1 Converter A  
LP  
Converter B Switch 2  
RFD  
8301-2 8303-2  
8303-3  
-
-
8307-2  
8307-3  
LED INDICATORS:  
-
LED  
Color Description  
Pwr:  
Yellow On-Power on  
iConverter 10FL/T Single-Fiber Modules  
Lk/Act (F/O): Green On-Link; Blink-Activity  
Lk/Act (UTP): Green On-Link; Blink-Activity  
LINK MODES:  
In order to accommodate different user needs, the 10FL/T  
supports two different linking modes.  
Fiber /  
Connector  
Type  
Tx: 1310 nm,  
Rx: 1550 nm  
Tx: 1550 nm,  
Rx: 1310 nm  
Distance  
MOUNTINGAND CABLE ATTACHMENT:  
The iConverter modules are hot-swappable and can be  
installed into any iConverter chassis.  
Switch 1 Converter A  
LED On  
Converter B Switch 2  
SM / SC  
SM / SC  
20 km  
40 km  
8310-1  
8310-2  
8311-1  
8311-2  
In Link Propagate (LP), sometimes referred to as “Link  
Loss Carry Forward”, a converter port transmits a Link  
signal only when receiving a Link at its other port. For  
example, the UTP transmits a Link only when receiving a  
Link at the fiber port [Fig 1(b)]. Link propagate is the  
factory default setting.  
LED Off  
1. Using the chassis’ module guides for alignment,  
insert the module into the selected slot and secure using  
the front panel fastener screw.  
LED status depends on connected device  
Off if device is AN, On if device is Manual  
For wide temperature (-40 to 60º C) modules, add a "W" to the  
end of the model number. Consult factory for other configurations  
and extended temperature(-40 to +75º C) modules.  
When using single-fiber (SF) media converter models, the Tx  
wavelength on one end has to match the Rx wavelength on the other.  
Fig. 1 Link Modes  
Page 2  
Page 3  
Page 4  
Page 5  
TECHNICAL SUPPORT:  
10FL/T SPECIFICATIONS:  
Notes:  
Limitation of Warranty  
Warning  
For help with this product, contact our Technical Support:  
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _  
The operating description in this Instruction Manual is  
for use by qualified personnel only. To avoid electrical  
shock, do not perform any servicing of this unit other  
than that contained in the operating instructions, unless  
you are qualified and certified to do so by Omnitron  
Systems Technology, Inc.  
The foregoing warranty shall not apply to defects  
resulting from improper or inadequate use and/or  
maintenance of the equipment by Buyer, Buyer-supplied  
equipment, Buyer-supplied interfacing, unauthorized  
modifications or tampering with equipment (including  
repairs of equipment by personnel not specifically  
authorized and certified by Omnitron), or misuse, or  
operating outside the environmental specification of  
the product (including but not limited to voltage, ambient  
temperature, radiation, unusual dust, etc.), or improper  
site preparation or maintenance.  
Model Type  
Protocols  
10FL/T  
Phone:  
Fax:  
(949) 250-6510  
(949) 250-6514  
10BASE-FL, 10 BASE-T  
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _  
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _  
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _  
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _  
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _  
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _  
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _  
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _  
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _  
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _  
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _  
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _  
Address: Omnitron Systems Technology, Inc.  
140 Technology Dr., #500  
UTP  
Connectors  
RJ-45  
Irvine, CA 92618 USA  
Fiber  
Connectors  
SC, ST, LC, MT-RJ,  
Single-Fiber SC  
E-mail:  
URL:  
Warranty  
This product is warranted to the original purchaser  
against defects in material and workmanship for a  
period of 2 YEARS from the date of shipment. A  
LIFETIME limited warranty may be obtained by the  
original purchaser by REGISTERING this product with  
Omnitron within 90 days from the date of shipment. To  
register, complete and mail or fax the enclosed  
Registration Card to the indicated address. You may  
also register your product on the internet at  
warranty period, Omnitron will, at its option, repair or  
replace a product which is proven to be defective.  
Controls  
LS/LP, RFD  
Power, F/O Link, UTP Link  
W:0.85" x D:4.5" x H:2.8"  
8 oz.  
LED Displays  
Dimensions  
Weight  
No other warranty is expressed or implied. Omnitron  
specifically disclaims the implied warranties of  
merchantability and fitness for any particular purpose.  
Exclusive Remedies  
UL, CE, FCC Class A  
NEBS Level 3  
,
Compliance  
The remedies provided herein are the Buyer’s sole and  
exclusive remedies. Omnitron shall not be liable for  
any direct, indirect, special, incidental, or consequential  
damages, whether based on contract, tort, or any legal  
theory.  
Power  
Requirement  
0.5A @ 3.3VDC (typical)  
Standard: 0 to 50º C  
Wide: -40 to 60º C  
Storage: -40 to 80º C  
For warranty service, the product must be sent to an  
Omnitron designated facility, at Buyer’s expense.  
Omnitron will pay the shipping charge to return the  
product to Buyer’s designated US address (within the  
48 contiguous states and the District of Columbia)  
using Omnitron’s standard shipping method.  
Temperature  
Humidity  
Altitude  
5 to 95% (non-condensing)  
-100m to 4000m  
830,000  
MTBF (hrs)  
040-08300-001J 9/07  
Page 6  
Page 7  
Page 8  
Page 9  
Page 10  
 

Milan Technology Network Card MIL W1897L User Manual
Miller Electric Welder SRH 503 User Manual
MTD Lawn Mower 111 040 User Manual
Novatel Model Vehicle OM 20000141 User Manual
Oki Printer C9200N User Manual
Omega Engineering Power Supply DRN PS 750 User Manual
Oregon Scientific Games BW68 User Manual
Outback Power Systems Automobile Battery Charger FX 2012T User Manual
Panasonic Router 324566 A User Manual
Panasonic Smoke Alarm 3312F User Manual