Making Pressure Connection  
Use proper tools and prepare tubing per switch using the actual working pressures  
GENERAL  
®
PSW-180 Teflon differential pressure switch  
utilizes a diaphragm sensor to monitor pressure  
changes. The switch utilizes dual diaphragm  
sensors to monitor the difference in pressure  
manufacturers recommendations. Cut tubing. Slip  
nut over tubing. Flare tubing. Press tubing onto  
pressure connection, making certain tubing is  
seated on pressure connection shoulder. Tighten  
nut, hand tight, onto pressure connection (see  
Figure 1).  
encountered in the application.  
®
between two sources. PFA Teflon wetted ports  
insure corrosion resistance in highly corrosive  
applications and is well suited for high purity  
applications.  
Dimensions  
Minimum torque requirement for 1⁄4” nut is 5  
inch • pounds (0.57 Newton • Meters). Be sure  
to connect high pressure source to port labeled  
“HIGH.” Connect low pressure source to “LOW.”  
Part I - Installation  
NEVER TIGHTEN BY TURNING THE  
CONTROL INTO THE FITTING.  
Tools Needed  
Applicable Screwdriver  
Flaretek® tubing cutter 213-14 or equal  
Flaretek® flaring tool 213-58 or equal  
Flaretek® tools may be ordered from  
Flouroware, Inc., Phone (612) 448 - 3131  
DO NOT USE A WRENCH. FITTING MUST  
BE HAND TIGHTENED ONLY, OVER  
TIGHTENING MAY DAMAGE THE PORT.  
WIRING  
ALL LIVE SUPPLY CIRCUITS MUST BE  
DISCONNECTED BEFORE WIRING THE  
CONTROL. CONNECT THE CONDUIT TO THE  
HOLE IN ACCORDANCE WITH NATIONAL AND  
LOCAL CODES. MAXIMUM RECOMMENDED  
WIRE SIZE IS 16 AWG.  
MOUNTING  
LOCATE SWITCH WHERE VIBRATION,  
SHOCK, AND AMBIENT TEMPERATURE  
FLUCTUATIONS ARE MINIMAL.  
The control can be mounted in any position.  
Locate where ambient temperature is above 30°F  
and below 160°F.  
Unscrew terminal just enough to put stripped  
wire under terminal block clamp. Nominal torque  
value for terminal block screws is 9.0 in-lbs.  
Surface Mounting  
Insert two #6 screws through mounting ear holes  
on 2” centers (recommended mounting for  
maximum vibration resistance). Follow directions  
for making pressure connection.  
Conduit hub is to be connected to conduit before  
conduit is connected to enclosure.  
All dimensions are stated in  
inches unless noted.  
Pipe Mounting  
Mount unit from its port(s). Follow directions for  
making pressure connection.  
Part II - Adjustments  
Tools Needed  
Flat blade screwdriver  
Use screwdriver to turn external adjusting screw  
on the side. Turn “in” (clockwise) to increase  
pressure setting. For best setting accuracy, set the  
Figure 1  
Teflon® is a registered trademark of E.I. Dupont Company  
Flaretek® is a registered trademark of Fluoroware, Inc.  
 

Miele Clothes Dryer T 8826 WP User Manual
Moxa Technologies Computer Hardware TCC 80I User Manual
MTD Chipper 642D thru 648D User Manual
Multiquip Portable Generator GAC36HZ User Manual
Nortel Networks Network Card AN DC User Manual
Oki Printer ML8810n User Manual
Omega Speaker Systems Thermometer HH801A User Manual
Oster Fondue Maker 135659 User Manual
Panasonic Digital Camera AK HC931BP User Manual
Parkside Glue Gun PHKP 500SE User Manual