WARNING: These products are not designed for use in, and should not be used for, patient
connected applications.
5
6
This device is marked with the international caution symbol. It is important to read the
SetupGuide before installing or commissioning this device as it contains important
information relating to safety and EMC.
Dec pt
Set Default Decimal Point
Scale Input Values
1. Press MENU. The meter displays:
It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply.
OMEGA is constantly pursuing certification of its products to the European New Approach
Directives. OMEGA will add the CE mark to every appropriate device upon certification.
ᮡ
ᮣ
/MIN
SETPTS
/MAX
MENU
RESET
1. Press ᮣ/MIN to display “INPUT 1”:
INPUT1
Press ᮣ/MIN again. The meter
The information contained in this document is believed to be correct, but OMEGA Engineering,
Inc. accepts no liability for any errors it contains, and reserves the right to alter specifications
without notice.
ᮡ
ᮣ
/MIN
SETPTS
/MAX
MENU
RESET
displays “000000”. Enter the INPUT 1
value recorded in step 1 of the Measure
Input Values section of this quick start.
2. Press ᮣ/MIN to display the current
decimal point. Change the display, if
necessary, to read “FFFFFF.” (Use
ᮡ/MAX to change the decimal point
position).
® are trademarks of OMEGA
®
®
,
,
TRADEMARK NOTICE:
omega.com
FFFFFF
Engineering, Inc.
ᮡ
ᮣ
/MIN
SETPTS
/MAX
MENU
RESET
2. Press MENU. The meter displays
“READ 1”:
READ 1
Press ᮣ/MIN to display a six-digit
number. Change the meter to read
“000000”. (Use ᮣ/MIN to scroll
through digits and ᮡ/MAX to change
the digit’s value.)
ᮡ
ᮣ
/MIN
SETPTS
/MAX
MENU
RESET
3. Press MENU. The meter stores changes (if applicable),
then displays “CNT BY”.
WARRANTY/DISCLAIMER
stored
CNTBY
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and
workmanship for a period of 13 months from date of purchase. OMEGA Warranty adds an
additional one (1) month grace period to the normal one (1) year product warranty to cover
handling and shipping time. This ensures that OMEGA’s customers receive maximum
coverage on each product.
DP41-E
High Performance Process Indicator
ᮡ
ᮣ
/MIN
SETPTS
/MAX
MENU
RESET
ᮡ
ᮣ
/MIN
SETPTS
/MAX
MENU
RESET
3. Press MENU. The meter displays
“INPUT 2”:
INPUT2
If the unit should malfunction, it must be returned to the factory for evaluation. OMEGA’s
Customer Service Department will issue an Authorized Return (AR) number immediately upon
phone or written request. Upon examination by OMEGA, if the unit is found to be defective it will
be repaired or replaced at no charge. OMEGA'S WARRANTY does not apply to defects resulting
from any action of the purchaser, including but not limited to mishandling, improper interfacing,
operation outside of design limits, improper repair, or unauthorized modification. This
WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence
of being damaged as a result of excessive corrosion; or current, heat, moisture or vibration;
improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s
control. Components which wear are not warranted, including but not limited to contact points,
fuses, and triacs.
Press ᮣ/MIN. The meter displays
“000000”. Enter the INPUT 2 value
recorded in step 2 of the Measure Input
Values section of this quick start.
ᮡ
ᮣ
/MIN
SETPTS
/MAX
MENU
RESET
4. Press RESET twice. The meter momentarily displays
“RESET 2” then returns to the run mode. The meter
will now read the input signal (4mA = ≈ 000000.
and 20mA = ≈ 020000.).
®
®
OMEGAnet® On-Line Service
Internet e-mail
4. Press MENU. The meter displays
“READ 2”:
OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA
neither assumes responsibility for any omissions or errors nor assumes liability for any damages
that result from the use if its products in accordance with information provided by OMEGA, either
verbal or written. OMEGA warrants only that the parts manufactured by it will be as specified and
free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY
KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED
WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSEARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies
of purchaser set forth herein are exclusive and the total liability of OMEGA with respect to this
order, whether based on contract, warranty, negligence, indemnification, strict liability or
otherwise, shall not exceed the purchase price of the component upon which liability is based. In
no event shall OMEGA be liable for consequential, incidental or special damages.
Measure and Record Input Values
READ 2
INPUT1
Servicing North America:
1. Apply 4mA to the input and record the
display reading.
INPUT 1 = _________________
Refer to this as Input One.
Press ᮣ/MIN to display a six digit
number. Change the meter to read
“001000”. (Use ᮣ/MIN to scroll through
ᮡ
ᮣ
/MIN
SETPTS
/MAX
MENU
RESET
ᮡ
ᮣ
/MIN
SETPTS
/MAX
MENU
RESET
USA:NN
ISO 9001 CertifiedN
One Omega Drive, P.O. Box 4047
Stamford CT 06907-0047
TEL: (203) 359-1660NN
NN
NN
FAX: (203) 359-7700
FAX: (514) 856-6886
e-mail: [email protected]
digits and ᮡ/MAX to change the digit’s value.)
Canada:NN
976 Bergar
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a
“Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2)
in medical applications or used on humans. Should any Product(s) be used in or with any nuclear
installation or activity, medical application, used on humans, or misused in any way, OMEGA
assumes no responsibility as set forth in our basic WARRANTY / DISCLAIMER language, and
additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or
damage whatsoever arising out of the use of the Product(s) in such a manner.
NN
NN
NN
Laval (Quebec) H7L 5A1
TEL: (514) 856-6928NN
e-mail: [email protected]
INPUT2
2. Apply 20mA to the input and record the
display reading.
INPUT 2 = _________________
Refer to this as Input Two.
5. Press MENU. The meter stores changes and displays:
ᮡ
ᮣ
/MIN
SETPTS
/MAX
MENU
RESET
For immediate technical or application assistance:
stored
Dec pt
USA and Canada:N
Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA®
Customer Service: 1-800-622-2378 / 1-800-622-BEST®
Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN®
TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA
RETURN REQUESTS / INQUIRIES
NN
NN
ꢀꢀ
ᮡ
ᮣ
/MIN
SETPTS
/MAX
MENU
RESET
ᮡ
ᮣ
/MIN
SETPTS
/MAX
MENU
RESET
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department.
BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN
AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE
DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number
should then be marked on the outside of the return package and on any correspondence.
3. Press MENU until the meter displays:
4. Press MENU until the meter displays:
Mexico and N
Latin American:ꢀ
NN
TEL: (001)800-TC-OMEGA®N
En Español: (001) 203-359-7803N
e-mail: [email protected]
FAX: (001) 203-359-7807
IN CNF
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to
prevent breakage in transit.
6. Press ᮣ/MIN to display the current decimal point. Press
ᮡ/MAX to change the decimal point location to “FFFFF.F”.
ᮡ
ᮣ
/MIN
SETPTS
/MAX
MENU
RESET
Servicing Europe:
FOR WARRANTY RETURNS, please have
FOR NON-WARRANTY REPAIRS, consult
the following information available BEFORE OMEGA for current repair charges. Have the
Benelux:NN
Postbus 8034, 1180 LA Amstelveen, The Netherlands
TEL: +31 20 3472121NN FAX: +31 20 6434643
contacting OMEGA:
following information available BEFORE
contacting OMEGA:
NN
NN
NN
1. P.O. number under which the product
was PURCHASED,
Toll Free in Benelux: 0800 0993344N
e-mail: [email protected]
7. Press MENU. The meter stores this change, then displays
“CNT BY”
stored
CNTBY
1. P.O. number to cover the COST of the
repair,
2. Model and serial number of product, and
3. Repair instructions and/or specific
problems relative to the product.
Press ᮣ/MIN to display “INP6=0”
Change the meter to read “INP.6=1”
(Use ᮣ/MIN to scroll through digits
and ᮡ/MAX to change the digit’s value).
INp6=0
2. Model and serial number of the product
under warranty, and
Czech Republic:N
Rudé armády 1868, 733 01 Karviná 8
TEL: +420 69 6311899N FAX: +420 69 6311114
e-mail: [email protected]
3. Repair instructions and/or specific
problems relative to the product.
NN
NN
ᮡ
ᮡ
ᮣ
/MIN
SETPTS
/MAX
MENU
RESET
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is
possible. This affords our customers the latest in technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC.
© Copyright 2002 OMEGA ENGINEERING, INC. All rights reserved.
France:NN
9, rue Denis Papin, 78190 Trappes
TEL: +33 130 621 400N FAX: +33 130 699 120
Toll Free in France: 0800406342
e-mail: [email protected]
NN
NN
ᮡ
ᮣ
/MIN
SETPTS
/MAX
MENU
RESET
ᮡ
ᮣ
/MIN
SETPTS
/MAX
MENU
RESET
NN
This document may not be copied, photocopied, reproduced, translated, or reduced to any
electronic medium or machine-readable form, in whole or in part, without prior written consent
of OMEGA ENGINEERING, INC.
5. Press MENU. The meter stores changes and displays:
Germany/Austria:N
Daimlerstrasse 26, D-75392 Deckenpfronn, Germany
TEL: +49 7056 9398-0N FAX: +49 7056 9398-29
Toll Free in Germany: 0800 639 7678
NN
NN
NN
8. Press RESET twice. The meter displays:
“RESET 2”, then returns to the run
mode. The meter is now scaled to
read 0 to 100.0 for a 4-20 mA input.
PATENT NOTICE: This product is covered by one or more of the following patents: U.S.
Pat. No. Des. 336,895; 5,274,577 / CANADA 2052599; 2052600 / ITALY 1249456;
1250938 / FRANCE BREVET No. 91 12756 / SPAIN 2039150; 2048066 / UK PATENT
No. GB2 249 837; GB2 248 954 / GERMANY DE 41 34398 C2. The “Meter Case Bezel
Design” is a trademark of NEWPORT Electronics, Inc., registered in the U.S. USED
UNDER LICENSE. OTHER INTERNATIONAL PATENTS PENDING.
e-mail: [email protected]
REset2
stored
INSCOF
United Kingdom:N
One Omega Drive
ISO 9002 CertifiedN
River Bend Technology Centre
ᮡ
ᮣ
/MIN
SETPTS
/MAX
MENU
RESET
NN
NN
NN
NN
Northbank, Irlam Manchester M44 5BD United Kingdom
TEL: +44 161 777 6611N FAX: +44 161 777 6622
Toll Free in England: 0800 488 488
e-mail: [email protected]
ᮡ
ᮣ
/MIN
SETPTS
/MAX
MENU
RESET
ᮡ
ᮡ
ᮣ
/MIN
SETPTS
/MAX
MENU
RESET
12450ML-99 Rev.F
MQS1297/0202
|