ST-C5VA-WL500
WALL MOUNT VGA VIDEO AND
STEREO AUDIO EXTENDER
Installation and Operation Manual
Man073 Rev 1/24/06
TABLE OF CONTENTS
Introduction......................................................................................................................................................................1
Materials..........................................................................................................................................................................1
Features and Functions...................................................................................................................................................2
Limitations .......................................................................................................................................................................3
Preparation for Installation ..............................................................................................................................................3
Installation .......................................................................................................................................................................4
Installing The Local Unit ..............................................................................................................................................4
Connect The CAT5 Cable.........................................................................................................................................4
Connect the CPU......................................................................................................................................................5
Connect a Local User ...............................................................................................................................................6
Installing The Remote Unit ..........................................................................................................................................7
Attach Wall Mount Brackets......................................................................................................................................7
Connect Monitor and Speakers ................................................................................................................................7
Connect the CAT5 cable...........................................................................................................................................8
Plug-in and Power Up.................................................................................................................................................8
Video Quality...................................................................................................................................................................9
Technical Specifications..................................................................................................................................................9
Interconnection Cable Wiring Method...........................................................................................................................10
Troubleshooting.............................................................................................................................................................10
Warranty Information.....................................................................................................................................................11
TABLE OF FIGURES
Figure 1- Install Local Unit to 2 gang outlet box................................................................................................................................4
Figure 2- Connect the Local Unit to the CPU.....................................................................................................................................5
Figure 3- Connect the local user to the XTENDEX Local Unit ...........................................................................................................6
Figure 4- Attach wall mount brackets to Remote Unit........................................................................................................................7
Figure 5- Connect monitor and speakers to the Remote Unit............................................................................................................7
Figure 6- Connect the CAT5 cable to the Remote Unit......................................................................................................................8
Figure 7- Connect the AC adapter to the Remote Unit ......................................................................................................................8
Figure 8- View looking into RJ45 female..........................................................................................................................................10
Download from Www.Somanuals.com.iAill Manuals Search And Download.
NTI XTENDEX Wall Mount Extenders
INTRODUCTION
The XTENDEX Series Wall Mount VGA Video and Stereo Audio Extender (XTENDEX) is designed to enable the VGA video and
stereo audio signals from one CPU to be viewed and heard by two users, one local and one remote. The remote user can be
located as much as 500 feet away via Category 5 unshielded twisted-pair cable. The local user will be located near the CPU.
The XTENDEX Series Wall Mount VGA Video and Stereo Audio Extender is extremely simple to install and has been thoroughly
tested to insure reliable performance. Through the use of Category 5 cable it is possible to economically increase the flexibility of
a computer system. Here are some of the features and ways this can benefit any workplace:
• Allows the placement of computer monitor and speakers in a location where only these parts are needed without having
the CPU there too, taking up valuable space
• Allows a CPU video and audio signal to be accessed by both a local and remote user (up to 500 feet away)
• Compatible with VGA, SVGA, and XGA systems
• Provides crisp and clear resolution up to 1024 x 768 @ 500 feet (see page 8 for more details)
• Compatible with all NTI switches and splitters, enabling the joining of products to create a system that
satisfies all networking needs
• Video quality adjustment, for varying lengths of cable, is automatic providing optimum image quality
• Digital transmission of audio signals reduces any loss in quality
MATERIALS
Materials Included with this kit:
9
9
9
9
9
9
9
9
9
9
NTI XTENDEX ST-C5VA-WL500 Local Unit
NTI XTENDEX ST-C5VA-WL500 Remote Unit
120VAC or 240VAC at 50 or 60Hz-12VDC/1.0A AC Adapter
VEXT-6 NTI 6 foot video cable with 15HD male on one end, 15HD female on the other end
SA-6-MM NTI 6 foot audio cable with 3.5mm stereo audio plugs on each end
2- Wall Mount Brackets
4- 4-40x1/4" Flat Head Screws
4- 6-32x1/2" Flat Head Screws
CD with a pdf file of this owner's manual
NTI Product Registration Card
Additional materials may need to be ordered, depending upon the configuration:
¾
CAT5/5e/6 unshielded twisted-pair cable(s) terminated with RJ45 connectors wired straight thru- pin 1 to pin 1, etc. (see pg.
10 for proper EIA/TIA 568 B wiring method)
Contact your nearest NTI distributor or NTI directly for all of your KVM needs at 800-RGB-TECH (800-742-8324) in US & Canada
1
NTI XTENDEX Wall Mount Extenders
ST-C5VA-WL500
Local Unit
(Front View)
(Rear View)
1
2
VIDEO
OUT
VIDEO
IN
15
AUDIO
IN
AUDIO
OUT
12VDC
1A
R
XTENDEX TMVA
Local Unit
NTI
3
4
5
6
7
FEATURES AND FUNCTIONS
1. VIDEO OUT- 15HD female video connector- for connecting the local user's VGA monitor
2. VIDEO IN- 15HD male video connector- for connecting to the video port on the CPU or KVM switch
3. AUDIO OUT- 3.5mm stereo audio jack- for connecting to local speakers
4. Power Indicator LED- to indicate that power has been supplied to the XTENDEX
5. 12VDC- 1.0A- connection jack for the AC adapter
6. AUDIO IN- 3.5mm stereo audio jack- for connecting to the audio port on the CPU or audio source
7. Cat5- RJ45 female- for connecting the CAT5 cable to the Local Unit
8. Cat5- RJ45 female- for connecting the CAT5 cable to the Remote Unit
9. Yellow LED- traffic indicator- illuminates when there is communication between the Local and Remote Units.
10. Green LED- power indicator- illuminates when power has been supplied to the Remote Unit (supplied through the CAT5
cable)
11. Audio Jack- 3.5mm stereo audio jack- for connecting to remote speakers
12. Video Connector- 15HD female- for connecting the remote user's VGA monitor
13. Wall Mount Bracket- to be attached if wall mounting the Remote Unit
14. 4-40 x 1/4" Flat Head Phillips screws- (qty. 4 supplied)- for attaching Wall Mount Bracket to Remote Unit
15. 6-32 x 1/2" Flat Head Phillips screws- (qty. 4 supplied) - for attaching Local Unit to 2 gang outlet box
11
12
8
14
13
X E D E N X T
R
10
9
c n I s e i g o l o n h c T k e r o w t N e
NTI
N T I
Ne twork Te chnologie s Inc
R
XTENDEX
(Front View)
(Rear View)
ST-C5VA-WL500
Remote Unit
2
NTI XTENDEX Wall Mount Extenders
LIMITATIONS
•
Hot-plugging of devices is supported provided devices were originally connected at power-up.
•
The audio input of the XTENDEX is compatible with the following standard CPU audio outputs:
•
•
•
Line out - typically lime green in color
Speaker out- typically orange in color
Headphone out- typically located on the CD-ROM
•
The audio output of the XTENDEX is compatible with self-powered stereo speakers.
PREPARATION FOR INSTALLATION
•
•
Locations should be chosen for the monitors and speakers that also have space to connect the Remote Unit within the
distance provided by the cables. If extension cables are needed, contact NTI for the cables required.
The CAT5 cables must be run to the locations where the Remote and Local Units will be connected. Be careful to route the
cables away from any sources of magnetic fields or electrical interference that might reduce the quality of the video signal
(i.e. AC motors, welding equipment, etc.).
•
•
All cables should be installed in such a way that they do not cause stress on their connections to the equipment. Extended
lengths of cable hanging from a connection may interfere with the quality of that connection. Secure cables as needed to
minimize this.
Properly shut down and disconnect the power from the CPU, monitors, and speakers to be separated. If other equipment is
involved whose connections are being interrupted, be sure to refer to the instruction manuals for that equipment for proper
disconnection and re-connection procedures before proceeding.
Note: CAT5 connection cable used between NTI XTENDEX Series Local and Remote or any XTENDEX Series products
should not be run underground, outdoors or between buildings.
!
WARNING: Outdoor or underground runs of CAT5 cable could be dangerous and will void the warranty.
CAT5 cable
(up to 500 feet)
ST-C5VA-500WL
Remote Unit
Local CPU
ST-C5VA-500WL
Local Unit
VGA
Multi-Scan
Monitor
VGA
Multi-Scan
Monitor
AC
Adapter
Local Monitor and
Stereo Speakers
Remote Monitor and
Stereo Speakers
Typical Application
3
NTI XTENDEX Wall Mount Extenders
INSTALLATION
Installing The Local Unit
Connect The CAT5 Cable
A CAT5 cable with an RJ45 connector wired straight through (see specification on page 10) should extend from a UL
Listed 2 gang electrical box at least far enough to make connection to the RJ45 connector on the back of the Local Unit
(see Fig. 1). The outlet box must be at least 2 inches deep.
1. Connect the CAT5 cable to the Local Unit. When properly inserted the cable end should snap into place.
!
WARNING: Never connect the XTENDEX to an Ethernet card, Ethernet router, hub or switch or other
Ethernet RJ45 connector of an Ethernet device. Damage to devices connected to the Ethernet may result.
2. Secure the Local Unit to the 2 gang outlet box using the 6-32X1/2" Phillips Flat Head screws (4) provided.
2 Gang Outlet Box (Min. 2" deep)
2 Gang Cover Plate
6-32 X 1/2" Flat Head Screws
(SUPPLIED)
Cat5 Cable
ST-C5VA-500WL
(from Remote Unit)
Local Unit
Figure 1- Install Local Unit to 2 gang outlet box
4
NTI XTENDEX Wall Mount Extenders
Connect the CPU
1. Connect the VEXT-6 video cable (provided) to the male 15HD connector on the Local Unit labeled "VIDEO IN".
Connect the other end of the cable to the video port on the CPU (see Fig. 2).
2. Connect the SA-6-MM audio cable (provided) between the connector on the Local Unit labeled "AUDIO IN" and the
audio output jack on the CPU marked "line out", "spkr", or "headphones" (see Fig. 2).
Notes:
If all 3 jacks are available, use the jack marked "line out".
The "line out" jack is typically lime green and may be marked with this symbol
The "spkr" jack is typically orange, and may be marked with this symbol
The "headphones" jack may be marked with this symbol
15HD Male
Video Connector
15HD Female
Video Connector
15HD Male
Video Connector
VIDEO
OUT
VIDEO
IN
VEXT-6
Video Cable- SUPPLIED
AUDIO
IN
AUDIO
OUT
3.5mm Stereo Jack
SA-6-MM
Audio Cable- SUPPLIED
12VDC
1A
PS/2 CPU
AUDIO CONNECTOR
R
XTENDEXTM VA
Local Unit
3.5mm Stereo Plug
NTI
line
out
ST-C5VA-WL500
Local Unit
ONE WILL BE MARKED "line
out" ,"spkr", "headphones"
OR WITH THIS SYMBOL
(Front View)
Figure 2- Connect the Local Unit to the CPU
5
NTI XTENDEX Wall Mount Extenders
Connect a Local User
(Optional)
1. Connect the cable from the local user's VGA monitor to the female 15HD connector labeled "VIDEO OUT" on
the Local Unit.
2. Connect the cable from the local speakers to the 3.5mm stereo audio jack labeled "AUDIO OUT" on the Local Unit.
15HD Male
15HD Female
Video Connector
Video Connector
VIDEO
OUT
VIDEO
IN
AUDIO
IN
AUDIO
OUT
3.5mm Stereo
Audio Plug
VGA
Multi-Scan
Monitor
3.5mm Stereo
Audio Jack
12VDC
1A
R
XTENDEXTM VA
Local Unit
NTI
ST-C5VA-WL500
Local Unit
(Front View)
Stereo
Speakers
Figure 3- Connect the local user to the XTENDEX Local Unit
6
NTI XTENDEX Wall Mount Extenders
Installing The Remote Unit
The Remote Unit can either set on a desk near the monitor and speakers to be connected, or it can be mounted to a vertical
surface using the wall mount brackets provided.
Attach Wall Mount Brackets
The two wall mount brackets can be secured to the Remote Unit using the four #4-40 x 1/4" screws provided (see Fig. 4). With
the brackets attached, mount the Remote Unit to any desired surface using suitable hardware (not included). Be sure to position
the Remote Unit such that the CAT5 cable, the monitor cable, and the speakers cable can each reach the Remote Unit without
putting strain on the cables.
4-40X1/4" Flat Head Screw
Wall Mount Bracket
ST-C5VA-WL500
Remote Unit
(Bottom View)
Figure 4- Attach wall mount brackets to Remote Unit
Connect Monitor and Speakers
1. Position the Remote Unit such that the CAT5 cable, the monitor cable, and the stereo audio cable can each reach the
Remote Unit without putting strain on the cables.
2. Connect the monitor cable to the female 15HD video connector on the Remote Unit.
3. Connect the cable from the remote speakers to the 3.5mm stereo audio jack on the Remote Unit (see Fig. 5).
15HD Female
Rear View of Remote Unit
Video Connector
VGA
X E D E N X T
Multi-Scan
Monitor
c n I s e i g o l o n h c e T k r o w t N e
N T I
R
3.5mm Stereo
Audio Jack
Stereo
Speakers
Figure 5- Connect monitor and speakers to the Remote Unit
7
NTI XTENDEX Wall Mount Extenders
Connect the CAT5 cable
Make sure the CAT5 cable has been installed in accordance with the “Preparation for Installation”
instructions on page 3. Connect the CAT5 cable to the “Cat 5” port on the Remote Unit (see Fig. 6).
When properly inserted the CAT5 cable end should snap into place.
Front View of Remote Unit
Green
Power LED
!
WARNING: Never connect the XTENDEX to an Ethernet
R
card, Ethernet router, hub or switch or other Ethernet RJ45
connector of an Ethernet device. Damage to devices
connected to the Ethernet may result.
NTI
Ne twork Te chnologie s Inc
XTENDEX
Yellow
Traffic LED
Note: The yellow LED on the
RJ45 connector on the Remote
Unit will illuminate anytime data
traffic is passing between the
Local and Remote Units.
CAT5 Cable to
Local Unit
Figure 6- Connect the CAT5 cable to the Remote Unit
Plug-in and Power Up
1. Plug the power cord from the monitors into power outlets. Also power up the speakers if they have external power supplies.
2. Connect the 12VDC AC adapter power connector to the 12VDC port on the Local Unit (see Fig. 7). Plug the AC adapter into
a power outlet. The green LED on the RJ45 connector of the Remote Unit and the power LED on the wallplate of the Local
Unit should each illuminate, indicating that a proper power connection has been made to them (see Fig. 6). (The Remote
Unit is powered by the Local Unit through the CAT5 cable.)
Barrel
3. Turn ON the CPU and Monitors.
They should each react as if they
were directly connected to each
other.
VIDEO
OUT
VIDEO
IN
Power Connector
12VDC @ 1.0A OUTPUT
(Outside
barrel)
(Inside
barrel)
AUDIO
IN
2.1 mm x 5.5 mm Female
AUDIO
OUT
12VDC
AC Adapter
12VDC
1A
R
XTENDEXTM VA
Local Unit
NTI
ST-C5VA-WL500
Local Unit
(Front View)
Figure 7- Connect the AC adapter to the Remote Unit
8
NTI XTENDEX Wall Mount Extenders
VIDEO QUALITY
Automatic Video Quality Adjustment
Video quality adjustment is done automatically to assure the image is as clear as possible.
Note: When the cable is longer than 300 feet some colored lines can be seen at the black-to-white transitions. This is a
normal behavior and is caused by the different twisting rates of each pair of wires in the CAT5 cable.
TECHNICAL SPECIFICATIONS
Video
Video Compatibility
Video Coupling
VGA, SVGA, XGA
DC
Video Connectors
HD15 male to CPU
HD15 female to monitor
Input / Output Impedance
Input Horizontal Frequency Range
Input Vertical Frequency Range
Sync Types Supported
Video Maximum I/O Levels
Audio
75 Ohms
15kHz to 130 Hz
30 Hz to 150 Hz
Separate and composite TTL Level and sync on green
1.45Vp-p
Audio Connectors
3.5mm stereo jack to speakers
3.5mm stereo jack to CPU
Line Level, stereo, unbalanced
20Hz to 20Khz, + 2dB
73 dBA
Signal Type
Audio Frequency Response
Signal-to-noise ratio
Total Harmonic Distortion and Noise
Stereo Crosstalk
0.011%
-69 dB
Audio Maximum I/O Levels
Output Impedance
3.1Vp-p
Max 2K Ohms, unbalanced
General
Interconnect Cable (General applications)
Interconnect Cable (CE applications)
Local Unit Power
CAT5/5e/6 Solid UTP EIA/TIA 568 B wiring w/ male RJ45 connectors
CAT5/5e/6 Solid STP EIA/TIA 568 B wiring w/ male RJ45 connectors
120V or 240V at 50 or 60Hz-12VDC/1.0A via AC Adapter
Powered by Local Unit
Remote Unit Power
Local Unit Size (In.) WxDxH
Remote Unit Size (In.) WxDxH
4.5x1.4x4.5
3.5x3.1x1.2
Distances and Resolutions for CAT5/CAT5e and CAT6 Cables
Unshielded Twisted Pair (UTP) Resolutions
UTP CABLE
CAT5/CAT5e
CAT5/CAT5e
CAT5/CAT5e
CAT5/CAT5e
DISTANCE (feet) RESOLUTION
500
400
300
100
1024x768 at 60Hz
1280x1024 at 60Hz
1600x1200 at 60Hz
1920x1440 at 60Hz
CAT6
CAT6
CAT6
300
200
100
1024x768 at 60Hz
1280x1024 at 60Hz
1920x1440 at 60Hz
9
NTI XTENDEX Wall Mount Extenders
INTERCONNECTION CABLE WIRING METHOD
The CAT5 connection cable between the remote and local is terminated with RJ45 connectors and must be wired according to the
EIA/TIA 568 B industry standard. Wiring is as per the table and drawing below.
Pair 3
Pair 2
Pair 1
Pair 4
Pin Wire Color
Pair
2
Function
1
2
3
4
5
6
7
8
White/Orange
Orange
White/Green
Blue
White/Blue
Green
White/Brown
Brown
T
R
T
R
T
R
T
R
2
3
1
1
3
4
4
T
T R
R
R
8
T R T
3
+
1
+
2
-
4
-
5
+ -
6 7
+ -
Figure 8- View looking into RJ45 female
Note: Shielded CAT 5,5e, or 6 cable must be used to connect to LOCAL and REMOTE units in order to meet CE emission
requirements.
Note: CAT5 connection cable used between NTI XTENDEX Series Local and Remote or any XTENDEX Series products
should not be run underground, outdoors or between buildings.
!
WARNING: Outdoor or underground runs of CAT5 cable could be dangerous and will void the warranty.
TROUBLESHOOTING
Each and every piece of every product produced by Network Technologies Inc is 100% tested to exacting specifications. We
make every effort to insure trouble-free installation and operation of our products. If problems are experienced while installing this
product, please look over the troubleshooting chart below for answers any questions that might arise. If the answer is not found
directly for help at 1-800-742-8324 (800-RGB-TECH) in US & Canada or 1-330-562-7070 worldwide. We will be happy to assist
in any way we can.
Problem
Cause
Solution
Remote or Local Unit
power indicator LED does
not illuminate
•
Power supply is not connected or
plugged-in.
•
•
•
Make sure outlet is live and AC adapter is plugged-in.
Make sure 12VDC power connector is fully inserted
Make sure CAT5 cable is connected at both ends
(Remote Unit is powered via the CAT5 cable)
•
•
One or more video cables is loose
or disconnected.
No power to Remote or Local
Units.
•
•
Check all video cable connections
No Video on monitor
Make sure power LEDs are illuminated for Local and
Remote (green LEDs). If not, see solutions for first two
problems above.
•
•
Video Cable was not attached
when CPU was booted.
CAT5 cable is not connected.
•
•
With all the cables properly connected, reboot the CPU.
Check cable connections. Make sure they are snapped-
in properly and completely and reboot.
Download from Www.Somanuals.com.1A0ll Manuals Search And Download.
NTI XTENDEX Wall Mount Extenders
Problem
Video Picture is not sharp
or is smeared
Cause
Solution
•
All Video Cables are not firmly
•
Check all connections. Make sure all cables are fully
seated.
seated.
•
•
CAT5 cable is too long.
The CAT5 cable is not properly
connected.
•
•
Verify length is within specified limits-500'.
Check cable connections. Make sure they are snapped-
in properly and completely.
•
Video not adjusted
•
Check cable connections and power cycle.
The picture on the monitor The video cable was not attached to
With the cables all properly connected, reboot the CPU.
Reroute CAT5 cable if possible.
is black and white, rather
than color
the CPU when it was booted.
A constant vertical wobble CAT5 cable is too close to a strong
appears down the screen
Monitor sometimes loses
sync, causing it to go
power source.
•
Electrical power system is very
•
•
•
Make sure the interconnection cable is not near any
power lines.
Check cable connections. Make sure they are snapped-
in properly and completely.
Check the user's manual for the monitor, projector, or
display equipment for an "automatic adjustment" or
"auto-configure". This is most common to LCD type
monitors.
noisy, particularly the ground.
The CAT5 cable is not properly
connected.
blank for a second or two
•
Image is not displayed
properly, lacks definition
Signal is being skewed by the CAT5
cable and not being received correctly
by the monitor .
No audio
•
Audio cable is not properly
plugged in
•
Check all cable connections
•
•
Speakers are not plugged in
CAT5 cable is not properly
connected
•
•
Verify speakers are connected and powered
Check CAT5 cable connections
WARRANTY INFORMATION
The warranty period on this product (parts and labor) is one (1) year from the date of purchase. Please contact Network
Technologies Inc at (800) 742-8324 (800-RGB-TECH) or (330) 562-7070 or visit our website at http://www.networktechinc.com
for information regarding repairs and/or returns. A return authorization number is required for all repairs/returns.
Manual 073 Rev. 1/24/06
Download from Www.Somanuals.com.1A1ll Manuals Search And Download.
|