NI PMA-1115 Portable Monitor Accessory.  
Overview  
The National Instruments PMA-1115 is a monitor and keyboard accessory  
for use with NI 8-slot PXI chassis. It includes the following features:  
15 in. high-brightness TFT LCD touch screen panel  
105-key English keyboard and touchpad  
Hardware for mounting to NI 8-slot PXI chassis  
Anti-glare tempered glass for LCD protection  
VGA and DVI connectivity to the LCD  
USB connectivity to the touch screen, keyboard, and touchpad  
Sheetmetal construction  
Universal AC/DC power supply with Y-cable for single wall  
connection  
RoHS compliance  
For complete PXI system configuration information, refer to ni.com/  
pxiadvisor.  
Shipping Components  
The NI PMA-1115 kit includes the following items:  
NI PMA-1115  
Adapter plate and mounting hardware  
Y-splitter power cable  
12 V DC/AC power adapter  
 
1
2
1
Handle covers  
2
Handle assembly  
Figure 2. Removing the Handle  
3. Remove the handle from the chassis. Retain the handle. Discard the  
screws.  
4. Attach the adapter plate to the chassis using the supplied M4 × 8  
pan-head screws, as shown in Figure 3.  
1
(6x)  
1
M4 × 8 pan-head screws  
Figure 3. Installing the Adapter Plate  
© National Instruments Corporation  
3
NI PMA-1115 User Guide and Specifications  
 
   
5. Reinstall the handle using the supplied 4-40 × 5/16 pan-head screws,  
as shown in Figure 4. Reinstall the handle covers by snapping them  
over the handle mounting plates.  
1
(4x)  
2
1
Handle covers  
2
4-40 × 5/16 pan-head screws  
Figure 4. Reinstalling the Handle and Handle Covers  
NI PMA-1115 User Guide and Specifications  
4
ni.com  
 
 
6. Orient the chassis and PMA-1115 as shown in Figure 5. Install the  
remaining M4 × 8 pan-head screws.  
(4x)  
1
1
M4 × 8 pan-head screws  
Figure 5. Installing the PMA-1115  
7. Open the keyboard and LCD, as shown in Figure 6. Install the supplied  
6-32 × 3/8 flat-head screws in the lower corners of the PMA-1115.  
1
1
6-32 × 3/8 flat-head screws  
Figure 6. Installing the Lower Mounting Screws  
© National Instruments Corporation  
5
NI PMA-1115 User Guide and Specifications  
 
   
8. If desired, use the provided interlocking fastener to attach the  
AC adapter to the unit. One suggested location is shown in Figure 7.  
Cable ties are also provided to organize the power cabling.  
Figure 7. Suggested Location for Attaching AC Adapter  
Note Do not place the AC adapter over any vent holes on the chassis cover, as this may  
cause chassis cooling issues.  
System Configuration  
The On-Screen Display (OSD) controls on the side of the PMA-1115  
provide standby functionality, as well as standard video adjustments for the  
LCD. The touch screen can be configured and calibrated through the  
TouchKit software found on the provided driver CD.  
Note The video resolution of the PXI Controller must be set to 1024 × 768 or lower.  
NI PMA-1115 User Guide and Specifications  
6
ni.com  
 
 
Ordering Information  
To order the NI PMA-1115 kit or power cords, refer to the following kit  
numbers.  
NI PMA-1115 Kit  
NI PMA-1115 Portable  
Monitor Accessory................................. 780215-01  
Additional Power Cords  
North American 240 VAC ..................... 763068-01  
Japanese 100 VAC................................. 763634-01  
United Kingdom 240 VAC .................... 763064-01  
Swiss 220 VAC...................................... 763065-01  
Australian 240 VAC............................... 763066-01  
Universal Euro 240 VAC....................... 763067-01  
Specifications  
AC/DC Adapter  
Input ....................................................... 100 to 240 VAC, 47 to 63 Hz,  
1.8 A maximum  
Output..................................................... 12 VDC, 5 A  
LCD  
Input ....................................................... 12 VDC, 5 A  
Type ....................................................... TFT LCD touch screen  
Auto-power switch................................. LCD goes into standby when  
no signal is present  
Power switch.......................................... Left side of product (STDBY)  
Diagonal size.......................................... 15 in. (38.11 cm)  
Maximum resolution.............................. 1024 × 768  
© National Instruments Corporation  
7
NI PMA-1115 User Guide and Specifications  
 
Display area ............................................11.97 × 8.98 in.  
(30.41 × 22.81 cm)  
Contrast ratio ..........................................500:1  
Brightness ...............................................300 NTS  
Frame rate...............................................60 Hz (typical),  
75 Hz (maximum)  
Color .......................................................16.2 M colors  
Viewing angle.........................................160° up and down  
160° right and left  
Control system........................................On screen display  
Connectivity............................................VGA or DVI-I  
Keyboard and Mouse  
Keyboard ................................................105-key, English language  
Mouse .....................................................Touchpad  
Connectivity............................................USB  
Mechanical  
Overall dimensions.................................14.75 × 2.31 × 11 in.  
(37.47 × 5.87 × 27.94 cm)  
without mounting plate  
Weight ....................................................5.0 kg (11 lb)  
LCD monitor folding angle ....................Up to 80°  
Environmental  
Maximum altitude...................................2,000 m (800 mbar)  
(at 25 °C ambient)  
Pollution Degree.....................................2  
For indoor use only.  
NI PMA-1115 User Guide and Specifications  
8
ni.com  
 
Operating Environment  
Ambient temperature range.................... 0 to 50 °C  
(Tested in accordance with  
IEC-60068-2-1 and  
IEC-60068-2-2. Meets  
MIL-PRF-28800F Class 3  
low temperature limit.)  
Relative humidity range......................... 10 to 90%, noncondensing.  
(Refer to Figure 8 for the  
correlation between temperature  
and humidity. Tested in  
accordance with  
IEC-60068-2-56.)  
Storage Environment  
Ambient temperature range.................... –20 to 60 °C  
(Tested in accordance with  
IEC-60068-2-1 and  
IEC-60068-2-2.)  
Relative humidity range......................... 10 to 90%, noncondensing.  
(Refer to Figure 8 for the  
correlation between temperature  
and humidity. Tested in  
accordance with  
IEC-60068-2-56.)  
© National Instruments Corporation  
9
NI PMA-1115 User Guide and Specifications  
 
Twb = 39 °C  
100  
90  
T = 40 °C,  
H = 90%  
80  
T = 50 °C,  
H = 55%  
60  
40  
T = 60 °C,  
H = 39%  
Storage  
Range  
Storage  
Range  
Operation Range  
20  
10  
-20  
0
10  
20  
30  
40  
50  
60  
Temperature (°C)  
Figure 8. Temperature/Humidity Relationship  
Shock and Vibration  
Operational shock...................................10 g peak, half-sine, 11 ms pulse  
(Tested in accordance with  
IEC-60068-2-27.)  
Random Vibration  
Operating ................................................5 to 500 Hz, 0.31 grms  
Nonoperating ..........................................5 to 500 Hz, 2.46 grms  
(Tested in accordance with  
IEC-60068-2-64. Nonoperating  
test profile exceeds the  
requirements of  
MIL-PRF-28800F, Class 3.)  
NI PMA-1115 User Guide and Specifications  
10  
ni.com  
 
 
Safety and Compliance  
Safety  
This product is designed to meet the requirements of the following  
standards of safety for information technology equipment:  
IEC 60950-1, EN 60950-1  
UL 60950-1, CSA 60950-1  
Note For UL and other safety certifications, refer to the product label or visit  
ni.com/certification, search by model number or product line, and click the  
appropriate link in the Certification column.  
Electromagnetic Compatibility  
This product is designed to meet the requirements of the following  
standards of EMC for electrical equipment for information technology  
equipment:  
EN 55024, CISPR 24  
EN 55022, CISPR 22  
CE, C-Tick, ICES, and FCC Part 15 Emissions; Class A  
Note For EMC compliance, operate this device according to product documentation.  
CE Compliance  
This product meets the essential requirements of applicable European  
Directives, as amended for CE marking, as follows:  
2006/95/EC; Low-Voltage Directive (safety)  
2004/108/EC; Electromagnetic Compatibility Directive (EMC)  
Note Refer to the Declaration of Conformity (DoC) for this product for any additional  
regulatory compliance information. To obtain the DoC for this product, visit  
ni.com/certification, search by model number or product line, and click the  
appropriate link in the Certification column.  
© National Instruments Corporation  
11  
NI PMA-1115 User Guide and Specifications  
 
Environmental Management  
National Instruments is committed to designing and manufacturing  
products in an environmentally responsible manner. NI recognizes that  
eliminating certain hazardous substances from our products is beneficial  
not only to the environment but also to NI customers.  
For additional environmental information, refer to the NI and the  
Environment Web page at ni.com/environment. This page contains the  
environmental regulations and directives with which NI complies, as well  
as other environmental information not included in this document.  
Waste Electrical and Electronic Equipment (WEEE)  
EU Customers At the end of their life cycle, all products must be sent to a WEEE recycling  
center. For more information about WEEE recycling centers and National Instruments  
WEEE initiatives, visit ni.com/environment/weee.htm.  
⬉ᄤֵᙃѻક∵ᶧ᥻
ㅵ⧚
⊩ ˄Ё೑  
˅
RoHS  
Ё೑ᅶ᠋  
݇Ѣ  
ヺড়Ё೑⬉ᄤֵᙃѻકЁ䰤
Փ⫼ᶤѯ᳝ᆇ⠽䋼ᣛҸ  
DŽ
National Instruments  
National Instruments  
(RoHS)  
Ё೑  
ড়㾘ᗻֵᙃˈ䇋ⱏᔩ ni.com/environment/rohs_chinaDŽ  
RoHS  
ni.com/environment/rohs_china  
(For information about China RoHS compliance, go to  
.)  
NI PMA-1115 User Guide and Specifications  
12  
ni.com  
 
Where to Go for Support  
The National Instruments Web site is your complete resource for technical  
support. At ni.com/supportyou have access to everything from  
troubleshooting and application development self-help resources to email  
and phone assistance from NI Application Engineers.  
National Instruments corporate headquarters is located at  
11500 North Mopac Expressway, Austin, Texas, 78759-3504.  
National Instruments also has offices located around the world to help  
address your support needs. For telephone support in the United States,  
create your service request at ni.com/supportand follow the calling  
instructions or dial 512 795 8248. For telephone support outside the United  
States, contact your local branch office:  
Australia 1800 300 800, Austria 43 662 457990-0,  
Belgium 32 (0) 2 757 0020, Brazil 55 11 3262 3599,  
Canada 800 433 3488, China 86 21 5050 9800,  
Czech Republic 420 224 235 774, Denmark 45 45 76 26 00,  
Finland 358 (0) 9 725 72511, France 01 57 66 24 24,  
Germany 49 89 7413130, India 91 80 41190000, Israel 972 3 6393737,  
Italy 39 02 41309277, Japan 0120-527196, Korea 82 02 3451 3400,  
Lebanon 961 (0) 1 33 28 28, Malaysia 1800 887710,  
Mexico 01 800 010 0793, Netherlands 31 (0) 348 433 466,  
New Zealand 0800 553 322, Norway 47 (0) 66 90 76 60,  
Poland 48 22 3390150,Portugal 351 210 311 210,Russia 7 495 783 6851,  
Singapore 1800 226 5886, Slovenia 386 3 425 42 00,  
South Africa 27 0 11 805 8197, Spain 34 91 640 0085,  
Sweden 46 (0) 8 587 895 00, Switzerland 41 56 2005151,  
Taiwan 886 02 2377 2222, Thailand 662 278 6777,  
Turkey 90 212 279 3031, United Kingdom 44 (0) 1635 523545  
© National Instruments Corporation  
13  
NI PMA-1115 User Guide and Specifications  
 
Important Information  
Warranty  
The PMA-1115 is warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced by  
receipts or other documentation. National Instruments will, at its option, repair or replace equipment that proves to be defective during the  
warranty period. This warranty includes parts and labor.  
The media on which you receive National Instruments software are warranted not to fail to execute programming instructions, due to defects in  
materials and workmanship, for a period of 90 days from date of shipment, as evidenced by receipts or other documentation. National Instruments  
will, at its option, repair or replace software media that do not execute programming instructions if National Instruments receives notice of such defects  
during the warranty period. National Instruments does not warrant that the operation of the software shall be uninterrupted or error free.  
A Return Material Authorization (RMA) number must be obtained from the factory and clearly marked on the outside of the package before any  
equipment will be accepted for warranty work. National Instruments will pay the shipping costs of returning to the owner parts which are covered by  
warranty.  
National Instruments believes that the information in this document is accurate. The document has been carefully reviewed for technical accuracy. In  
the event that technical or typographical errors exist, National Instruments reserves the right to make changes to subsequent editions of this document  
without prior notice to holders of this edition. The reader should consult National Instruments if errors are suspected. In no event shall National  
Instruments be liable for any damages arising out of or related to this document or the information contained in it.  
EXCEPT AS SPECIFIED HEREIN, NATIONAL INSTRUMENTS MAKES NO WARRANTIES, EXPRESS OR IMPLIED, AND SPECIFICALLY DISCLAIMS ANY WARRANTY OF  
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. CUSTOMERS RIGHT TO RECOVER DAMAGES CAUSED BY FAULT OR NEGLIGENCE ON THE PART OF NATIONAL  
INSTRUMENTS SHALL BE LIMITED TO THE AMOUNT THERETOFORE PAID BY THE CUSTOMER. NATIONAL INSTRUMENTS WILL NOT BE LIABLE FOR DAMAGES RESULTING  
FROM LOSS OF DATA, PROFITS, USE OF PRODUCTS, OR INCIDENTAL OR CONSEQUENTIAL DAMAGES, EVEN IF ADVISED OF THE POSSIBILITY THEREOF. This limitation of  
the liability of National Instruments will apply regardless of the form of action, whether in contract or tort, including negligence. Any action against  
National Instruments must be brought within one year after the cause of action accrues. National Instruments shall not be liable for any delay in  
performance due to causes beyond its reasonable control. The warranty provided herein does not cover damages, defects, malfunctions, or service  
failures caused by owner’s failure to follow the National Instruments installation, operation, or maintenance instructions; owner’s modification of the  
product; owner’s abuse, misuse, or negligent acts; and power failure or surges, fire, flood, accident, actions of third parties, or other events outside  
reasonable control.  
Copyright  
Under the copyright laws, this publication may not be reproduced or transmitted in any form, electronic or mechanical, including photocopying,  
recording, storing in an information retrieval system, or translating, in whole or in part, without the prior written consent of National  
Instruments Corporation.  
National Instruments respects the intellectual property of others, and we ask our users to do the same. NI software is protected by copyright and other  
intellectual property laws. Where NI software may be used to reproduce software or other materials belonging to others, you may use NI software only  
to reproduce materials that you may reproduce in accordance with the terms of any applicable license or other legal restriction.  
Trademarks  
National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. Refer to the Terms of Use section  
on ni.com/legalfor more information about National Instruments trademarks.  
Other product and company names mentioned herein are trademarks or trade names of their respective companies.  
Patents  
For patents covering National Instruments products, refer to the appropriate location: Help»Patents in your software, the patents.txtfile  
on your media, or ni.com/patents.  
WARNING REGARDING USE OF NATIONAL INSTRUMENTS PRODUCTS  
(1) NATIONAL INSTRUMENTS PRODUCTS ARE NOT DESIGNED WITH COMPONENTS AND TESTING FOR A LEVEL OF  
RELIABILITY SUITABLE FOR USE IN OR IN CONNECTION WITH SURGICAL IMPLANTS OR AS CRITICAL COMPONENTS IN  
ANY LIFE SUPPORT SYSTEMS WHOSE FAILURE TO PERFORM CAN REASONABLY BE EXPECTED TO CAUSE SIGNIFICANT  
INJURY TO A HUMAN.  
(2) IN ANY APPLICATION, INCLUDING THE ABOVE, RELIABILITY OF OPERATION OF THE SOFTWARE PRODUCTS CAN BE  
IMPAIRED BY ADVERSE FACTORS, INCLUDING BUT NOT LIMITED TO FLUCTUATIONS IN ELECTRICAL POWER SUPPLY,  
COMPUTER HARDWARE MALFUNCTIONS, COMPUTER OPERATING SYSTEM SOFTWARE FITNESS, FITNESS OF COMPILERS  
AND DEVELOPMENT SOFTWARE USED TO DEVELOP AN APPLICATION, INSTALLATION ERRORS, SOFTWARE AND HARDWARE  
COMPATIBILITY PROBLEMS, MALFUNCTIONS OR FAILURES OF ELECTRONIC MONITORING OR CONTROL DEVICES,  
TRANSIENT FAILURES OF ELECTRONIC SYSTEMS (HARDWARE AND/OR SOFTWARE), UNANTICIPATED USES OR MISUSES, OR  
ERRORS ON THE PART OF THE USER OR APPLICATIONS DESIGNER (ADVERSE FACTORS SUCH AS THESE ARE HEREAFTER  
COLLECTIVELY TERMED “SYSTEM FAILURES”). ANY APPLICATION WHERE A SYSTEM FAILURE WOULD CREATE A RISK OF  
HARM TO PROPERTY OR PERSONS (INCLUDING THE RISK OF BODILY INJURY AND DEATH) SHOULD NOT BE RELIANT SOLELY  
UPON ONE FORM OF ELECTRONIC SYSTEM DUE TO THE RISK OF SYSTEM FAILURE. TO AVOID DAMAGE, INJURY, OR DEATH,  
THE USER OR APPLICATION DESIGNER MUST TAKE REASONABLY PRUDENT STEPS TO PROTECT AGAINST SYSTEM FAILURES,  
INCLUDING BUT NOT LIMITED TO BACK-UP OR SHUT DOWN MECHANISMS. BECAUSE EACH END-USER SYSTEM IS  
CUSTOMIZED AND DIFFERS FROM NATIONAL INSTRUMENTS' TESTING PLATFORMS AND BECAUSE A USER OR APPLICATION  
DESIGNER MAY USE NATIONAL INSTRUMENTS PRODUCTS IN COMBINATION WITH OTHER PRODUCTS IN A MANNER NOT  
EVALUATED OR CONTEMPLATED BY NATIONAL INSTRUMENTS, THE USER OR APPLICATION DESIGNER IS ULTIMATELY  
RESPONSIBLE FOR VERIFYING AND VALIDATING THE SUITABILITY OF NATIONAL INSTRUMENTS PRODUCTS WHENEVER  
NATIONAL INSTRUMENTS PRODUCTS ARE INCORPORATED IN A SYSTEM OR APPLICATION, INCLUDING, WITHOUT  
LIMITATION, THE APPROPRIATE DESIGN, PROCESS AND SAFETY LEVEL OF SUCH SYSTEM OR APPLICATION.  
NI PMA-1115 User Guide and Specifications  
14  
ni.com  
 
National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation.  
Refer to the Terms of Use section on ni.com/legalfor more information about National  
Instruments trademarks. Other product and company names mentioned herein are trademarks or trade  
names of their respective companies. For patents covering National Instruments products, refer to the  
appropriate location: Help»Patents in your software, the patents.txtfile on your media,  
or ni.com/patents.  
© 2008 National Instruments Corporation. All rights reserved.  
372430B-01  
Apr08  
 

Milwaukee Router 5626 68 User Manual
Murphy Switch A20 Series User Manual
Mustang Survival Life Jacket MD1127 User Manual
Nilfisk ALTO Vacuum Cleaner MX 107 C User Manual
Omega Engineering Network Card DAQ 12 User Manual
Onkyo Home Theater System TX SR606 User Manual
Panasonic Camcorder AG HCK10 User Manual
Panasonic Network Card 2SC2631 User Manual
Panasonic Router 324566 A User Manual
Panasonic Security Camera BB HNP15A User Manual