SCG300-10-001
NEC Express5800/ft series
System Configuration Guide
Model R320a-E4/M4 (VMware)
August 2010
IT Network Global Solutions Division
NEC Express5800/R320a-E4/M4
System Configuration Guide
Quad-Core Intel Xeon Processor supported
4U Rackmount form factor
VMware vSphere4 supported
Specification Overview
Model
Express5800/R320a-E4
Express5800/R320a-M4
Redundancy
Redundant
Product Number
N8800-149F
Intel® Xeon® Processor
E5504
N8800-150F
Intel® Xeon® Processor
X5570
CPU*1
CPU
Clock Speed
2GHz
2.93GHz
No. of CPU (Standard/Max)
L3 Cache
1 / 2
4MB
8MB
Core (C)/ Thread (T) (1CPU)
4C/4T
4C/8T
Intel®5500 + GeminiEngine™(FPGA)
Redundant
Redundant
Chipset
Memory*1
Standard
Minimum
Memory less
4GB
(2GBDIMM ×1×2)
96GB
Maximum
(8GBDIMM ×3×4)
DDR3 SDRAM DIMM, Registered
Memory type
Operating frequency (Max)
Error detection/correction
800MHz
1066MHz
ECC, x4 SDDC
-
Redundant
Storage
Drive bay
Standard capacity
Maximum capacity
Hot plug
2.5 inch HDD:
SAS 2.4TB (8 ×300GB)*2
Supported
Interface and RAID
Optical Disk Drive
FDD
SAS 3Gb/s: RAID1 (Standard)
DVD-RAM drive*3
External drive (option)
2 × PCI Express 2.0
Redundant
(x4 lane, x8 socket)*4
+
2 × PCI Express 1.0
(x4 lane, x8 socket)*4
Supported slot
Expansion slot
Graphics
2 × PCI Express 1.0
(x4 lane, x8 socket)*4
Installation Type / Video RAM
Color ,Resolution [dot]
Integrated in Server Management Controller / 32MB
16,777,216-color: 800x600, 1024x768
65,536-color: 1280x1024
1 x Analog RGB (Mini D-Sub15 pin, 1x Rear),
4 x USB2.0 (1x Front, 3x Rear)
External Interface
Redundant
Redundant
2x 1000BASE-T LAN connector
(1000BASE-T/100BASE-TX, RJ-45, 2× Rear)*4
、
1 × Management LAN connector
(100BASE-TX/10BASE-T, RJ-45, 1× Rear)*4
External dimension (W x D x H)
Weight (Min / Max)
483×736×178mm (Not including protrusion)
46kg/52kg
AC100V-240V±10%, 50/60Hz±3Hz,
2 x AC inlets
Power Supply
Power consumption (Max config, high load)
Operation Condition (Temperature, Humidity)
1400VA/1390W
During operation: 10 to 35 / 20 to 80% (non condensation),
℃
When stored: -10 to 55 / 20 to 80% (non condensation)
℃
EXPRESSBUILDER ESMPRO/ServerManager(for Windows)),
(
Included Accessories
Supported OS
User's Guide, User's Guide (Setup), Key
VMware vSphere4 update1
*1 Specifications are for each CPU/IO module. Actual number is double that is specified due to duplication
*2 Logical Capacity
*3 Writing function is not supported
*4 The number of Slots in each CPU/IO module
1st Edition August ’10
Page 1
System Configuration Guide
NEC Express5800/R320a-E4/M4
Outward
450
689
736
483
178
Tower conversion kit
804
220
592
327
1st Edition August ’10
Page 2
System Configuration Guide
NEC Express5800/R320a-E4/M4
R320a-E4 Quick configuration sheet:
CPU/IO module #0
Onboard LAN
Intel® Xeon®
Processor
E5504
1000BASE-T x1
1000BASE-T x1
CPU 2
CPU slot x 2
Memory slot x 6
Memory slot x 6
Management LAN x 1
#2
#1
Low-profile PCI-Express x4×2
(x8 socket)
2.5 inch HDD bay x 8
PSU
CPU/IO module #1
Onboard LAN
Intel® Xeon®
Processor
E5504
1000BASE-T x1
1000BASE-T x1
CPU 2
CPU slot x 2
Memory slot x 6
Memory slot x 6
Management LAN x 1
Low-profile PCI-Express x4 x2
(x8 socket)
#2
#1
2.5 inch HDD bay x 8
PSU
DVD-RAM
1st Edition August ’10
Page 3
System Configuration Guide
NEC Express5800/R320a-E4/M4
R320a-M4 Quick configuration sheet:
CPU/IO module #0
Onboard LAN
Intel® Xeon®
Processor
X5570
1000BASE-T×1
1000BASE-T×1
CPU 2
CPU slot x 2
Management LAN x 1
Memory slot x 6
Memory slot x 6
#4
Full-height PCI-Express x4 x2
(x8 socket) #3
#2
#1
Low-profile PCI-Express x4 x2
(x8 socket)
2.5 inch HDD bay x 8
PSU
CPU/IO module #1
Onboard LAN
Intel® Xeon®
Processor
X5570
1000BASE-T×1
1000BASE-T×1
CPU 2
Management LAN x 1
CPU slot x 2
Memory slot x 6
Memory slot x 6
#4
#3
Full-height PCI-Express x4 x2
(x8 socket)
#2
Low-profile PCI-Express x4x2
(x8 socket)
#1
2.5 inch HDD bay x 8
PSU
DVD-RAM
1st Edition August ’10
Page 4
System Configuration Guide
NEC Express5800/R320a-E4/M4
Notes for configuring FT server with VMware
The following are needed to configure FT server VMware model.
1. FT server main unit
Select main unit and add optional CPU, Memory, HDD, PCI cards, etc.
N8800-149F
N8800-150F
Express5800/R320a-E4
Express5800/R320a-M4
2. VMware license
Select VMware license and optional license.
VMware vSphere 4 Standard
for 1 processor
VMware vSphere 4 Essentials
for 3 hosts
VMware vSphere 4 Essentials
Plus for 3 hosts
VMware vSphere 4 Enterprise
for 1 processor
VMware vSphere 4 Enterprise
Plus for 1 processor
VMware vSphere 4 Advanced
for 1 processor
3. NEC Storage
If needed, external storage can be connected for SAN boot and data disk.
Procure as system requirement.
D3-10
D4-30
D8-10/20/30
E1-10
4. UPS
Procure as needed. (Local procurement)
5. Guest OS license
6. VMware vSphere Client
A dedicated terminal is required for management of VMware vSphere 4 on the FT server. (Local procurement)
7. NEC Storage management server
Required when using NEC Storage.
8. Backup server
Dedicated server is recommended for backup.
9. NEC ESMPRO Agent
Download from ITPF portal site.
1st Edition August ’10
Page 5
System Configuration Guide
NEC Express5800/R320a-E4/M4
FT server (main unit)
Low-End rack mount
N8800-149F NEC Express5800/R320a-E4 (4C/E5504-VM) Memory less, HDD less
Intel ® Xeon® Processor E5504 (2.0GHz) x 1, 4MB 3rd cache, QPI speed 4.8GT/s
Memory less (Mandatory option, Minimum 4GB, Max 96GB), HDD less (SAS HDD),
DVD-RAM drive x1, 1000BASE-T 2ch as standard, PCI slot x2,
EXPRESSBUILDER (NEC ESMPRO Manager included)
Intel® Xeon®
Processor E5504
VMware
vSphere4
Update1 supported
Mid-Range rack mount
N8800-150F NEC Express5800/R320a-M4 (4C/X5570-VM) Memory less, HDD less
Intel® Xeon® Processor X5570 (2.93GHz) x1, 8MB 3rd cache, QPI speed 6.4GT/s
Memory less (Mandatory option, Minimum 4GB, Max 96GB), HDD less (SAS HDD),
DVD-RAM drive x1, 1000BASE-T 2ch as standard, PCI slot x4,
EXPRESSBUILDER (NEC ESMPRO Manager included)
Intel® Xeon®
Processor X5570
VMware
vSphere4
update1 supported
1st Edition August ’10
Page 6
System Configuration Guide
NEC Express5800/R320a-E4/M4
Processors
[Note]
- A pair of Quad-Core Xeon Processor is installed as standard.
- CPU kit contains a pair of the processors to install both CPU/IO Module #0 and CPU/IO
Module #1.
For R320a-E4
Socket #0: Standard Processor
Processor
Sockets
Quad-Core Intel Xeon Processor E5504, 2 GHz, 4 MB L3 Cache, QPI 4.8GT/s as standard
Socket #1: Additional Processor
N8801-041
CPU Kit(4C/E5504)
Quad-Core Intel Xeon E5504, one pair
2 logical
sockets
For R320a-M4
Socket #0: Standard Processor
Quad-Core Intel Xeon Processor X5570, 2.93 GHz, 8 MB L3 Cache, QPI 6.4GT/s as standard
Socket #1: Additional Processor
N8801-042
CPU Kit(4C/X5570)
Quad-Core Intel Xeon X5570, one pair
Memory
[Note]
- 8GB or more memory is recommended.
DIMM
Sockets
Product List
DDR3-1066 Registered DIMM:
N8802-041
N8802-042
N8802-043
2GB Memory kit
12GB Memory kit
24GB Memory kit
2X 2 GB DIMM (1x 2GB/module)
6X 4 GB DIMM (3x 4GB/module)
6X 8 GB DIMM (3x 8GB/module)
12 logical
sockets
Memory configuration pattern
DIMM Slot number
Standard CPU side 2nd CPU side
12 11 10 9
CPU Total MEM
1
2
2
2
2
2
4
4
8
8
8
2
3
2
2
2
2
2
4
4
8
8
8
4
5
6
8
7
4GB
6GB
2
2
2
2
4
4
8
8
8
8GB
2
2
2
10GB
2
2
12GB
2
4
1
12GB
24GB
24GB
36GB
48GB
4GB*1
6GB
4
4
4
8
4
8
4
8
2
2
2
2
2
2
2
2
4
4
4
8
8
8
2
2
2
2
2
2
2
2
2
4
4
4
8
8
8
2
8GB
2
10GB
12GB
16GB
2
2
2
2
2
2
2
4
4
4
8
8
8
2
2
2
2
4
4
4
8
8
8
2
2
2
2
4
4
4
8
8
8
2
2
2
2
4
4
4
8
8
8
2
2
2
2
2
2
20GB
2
2
2
2
2
24GB
2
2
24GB
36GB
48GB
48GB
72GB
96GB
2
4
2
4
2
4
2
4
2
4
2
4
4
8
4
8
4
8
4
8
4
8
4
8
*1: Memory interleave is valid except 2GB DIMM per CPU configuration.
1st Edition August ’10
Page 7
System Configuration Guide
NEC Express5800/R320a-E4/M4
Hard disk drives
[Note]
- Up to 16 hard disk drives can be installed in the system.
- Be sure to install by double of hard disk drives in order to have the RAID-1 configuration.
Also both of the hard disk drives must have same capacity and rotational speed.
2.5 INCH
Disk bays
Product List
2.5 inch SAS:
N8850-038
N8850-039
N8850-040
N8850-041
146.5GB 10k rpm SAS HDD 1X 146.5 GB HDD, w/ carrier
16 hot-swap
drive bays
300GB 10k rpm SAS HDD
73.2GB 15k rpm SAS HDD
1X 300 GB HDD, w/ carrier
1X 73.2 GB HDD, w/ carrier
146.5GB 15k rpm SAS HDD 1X 146.5 GB HDD, w/ carrier
Disk bay x 8
Disk bay x 8
CPU/IO module#0
CPU/IO module #1
#0
#0
System Disk
#2
#4
#5
#2
#3
#6
#4
#5
#6
#7
System Disk
#3
#7
#1
#1
Mirror
reduce the time to resynchronize.
* The mirroring function copies only changed files to resynchronize when replacing CPU/IO module, etc. in
order to save time. However, all data in the HDD need to be copied when replacing HDD to new one.
Server Management
Onboard
RAS chip
R320a-E4/M4 have the enhanced remote management function "EXPRESSSCOPE Engine2" as standard.
EXPRESSSCOPE Engine 2 (Standard)
*There is Management LAN port (100/10BASE-TX) on each CPU/IO module.
1st Edition August ’10
Page 8
System Configuration Guide
NEC Express5800/R320a-E4/M4
LCD Monitor
[Note]
- A monitor is required for maintenance.
Monitor:
15 INCH LCD
D-sub 15 pin
Interface
Local procurement
1 connector
Input devices
USB
Interface
Keyboard:
N8870-002AF
Mouse:
104 keyboard
1.8m cable length
1.8m cable length
3 connector
N8870-010A
Mouse
Extension cable:
K410-177(1A)
USB cable 1.5m
Floppy disk drive
[Note]
- The floppy drive is mandatory option due to maintenance.
- The USB extension cables can be used up to 1.5 m length.
- A tray to install the floppy disk drive is necessary to install in the rack mount system.
Product List
Floppy disk drive :
USB
Interface
N8160-81
External FDD
2mode (720 KB/ 1.44 MB), 0.9m cable length
Extension cable:
K410-177(1A)
3 connector
USB cable 1.5m
1st Edition August ’10
Page 9
System Configuration Guide
NEC Express5800/R320a-E4/M4
Optical disk drive
[Note]
-Writing function is not supported.
-Optical disk drive is not accessible after installing ft Server Control Software.
If you need to access the Optical disk drive, use the following command for temporary
use.
# /opt/ft/sbin/enable-usb-storage
Using Optical disk drive is not recommended.
USB
Interface
Optical disk drive:
Slimline DVD-RAM drive included in the front panel as standard
1 internal
connector
KVM switch
[Note]
- ft Server must be connected to the master KVM switch when cascade connection.
- Be sure to apply PS/2 typed keyboard/Mouse to connect to KVM switch.
- Updating the keyboard information is required after the installation has been complete,
because the operating system recognizes the keyboard as a 101 keyboard.
- Reconnect the cables or reset the KVM switch if the keyboard and mouse are out of
function after CPU/IO module fail over.
Sample configuration
Master
Switch unit connection cable
set [K410-118(xx)]
LCD Monitor
<Local procurement>
USB
Interface
Server Switch Unit
(8Port/USB) [N8191-10F]
104 Keyboard
<Local procurement>
Switch unit connection cable
set [K410-119(xx)]
Switch unit connection cable
set [K410-119(1A)]
D-sub 15pin
Interface
2 button w/ wheel mouse
[N8170-15]
Slave
PS/2
Server Switch Unit
(8Port/USB) [N8191-10F]
Cascade connection of KVM
switches is allowed up to two
tiers.
Express5800/100 Series
Switch unit connection cable
set [K410-119(xx)]
PS/2
Express5800/100 Series
Product List
KVM switch:
N8191-10F
Server Switch Unit(8Server/USB)
Switch unit connection cable set
Switch unit connection cable set
Switch unit connection cable set
Swtich unit connection cable set
Display/Keyboard extension cable
1U or Desktop
Cables:
K410-118(1A)
K410-118(03)
K410-119(1A)
K410-119(03)
K410-104A(03)
Keyboard/Mouse:
KVM unit – Server, USB, 1.8 m
KVM unit – Server, USB, 3 m
KVM unit – Server, PS/2, 1.8 m
KVM unit – Server, PS/2, 3 m
KVM unit – Keyboard/Mouse, PS/2, 3 m
104Keyboard
2 button w/ wheel mouse
PS/2
PS/2
N8170-15
1st Edition August ’10
Page 10
System Configuration Guide
NEC Express5800/R320a-E4/M4
17 inch LCD console unit
USB
Interface
Switch Unit Connection Cable Set (1.8m/3m/5m)
[K410-118(1A)] (1.8m)
[K410-118(03)] (3m)
[K410-118(05)] (5m)
D-sub 15pin
Interface
•Up to eight servers can be connected directly to the LCD console unit. Use optional Server
Switch Units to connect more than eight servers.
LCD Console Unit
A 17-inch LCD, keyboard, mouse, and Server Switch Unit (x8)
are integrated into the 1U LCD Console Unit.
- 17-inch LCD Console Unit (1U/8port) [N8143-69F]
Consists of the following components:
17-inch LCD
1280x1024 max. Full color
Keyboard (no ten-key numeric keypad)
Optical Mouse
Server Switch Unit
- Supports up to eight servers.
- Cascade connection of KVM switches is allowed up to two tiers.
Switch Unit Connection Cable Set (1.8m)
[K410-119(1A)]
Server Switch Unit
- Server Switch Unit (8 ports) [N8191-10F]
•The 17-inch LCD Console Unit [N8143-69F] allows the connection of up to 64 servers
by cascading eight Server Switch Units [N8191-10F].
•The 17-inch LCD Console Unit [N8143-69F] does not support other SSUs [N8191-09F/
-09AF].
1st Edition August ’10
Page 11
System Configuration Guide
NEC Express5800/R320a-E4/M4
Tower conversion kit
[Note]
- No tape device can be connected to R320a with Tower conversion kit without rack.
N8843-003
Tower conversion kit
23 inch height pedestal rack with Front bezel for R320a
327(W)x804(D)x592(H)mm, 26.5kg (including stabilizer)
1st Edition August ’10
Page 12
System Configuration Guide
NEC Express5800/R320a-E4/M4
Network (LAN)
[Note]
- Be sure to connect four physical LAN interfaces to the network HUB. Each of two pairs
of 1000BASE-T on the CPU/IO module is redundant configuration.
- Be sure to install the network cards on the same PCI slot# of each CPU/IO module.
Configuration
1000BASE-T :
RJ-45
connector
4 connector
PCI-Ex Slot
1000BASE-T Network
2channel 1000BASE-T
Controller [N8804-007]
1 logical slot
Product List
1000BASE-T :
N8804-007
2-channel 1000BASE-T controller set
a pair of controller
1st Edition August ’10
Page 13
System Configuration Guide
NEC Express5800/R320a-E4/M4
VMware license
[Note]
- The R320a VMware models support VMware vSphere 4 Update 1.
- VMware vSphere 4 license for Small Business
UL1610-003-GL VMware vSphere 4 Essentials Bundle for 3 hosts (Max 2 CPUs per host and 6 cores per CPU) *1
UL1610-004-GL
VMware vSphere 4 Essentials Plus Bundle for 3 hosts (Max 2 CPUs per host and 6 cores per CPU) *2
*1: ESX license for up to 3 Physical servers (Max 2 CPUs each) and VMware vCenter Server license for 3 ESX servers.
*2: ESX license for up to 3 Physical servers (Max 2 CPUs each) and VMware vCenter Server license for 3 ESX servers.
Also, Data Recovery and HA license for 6 CPUs included.
- VMware vSphere 4 license for Medium and Large-sized Business
UL1610-005-GL VMware vSphere 4 Standard for 1 processor (Max 6 cores per CPU) *3
UL1610-006-GL
UL1610-007-GL
UL1610-008-GL
VMware vSphere 4 Advanced for 1 processor (Max 12 cores per CPU) *3
VMware vSphere 4 Enterprise for 1 processor (Max 6 cores per CPU) *3
VMware vSphere 4 Enterprise Plus for 1 processor (Max 12 cores per CPU) *3
*3: VMware vCenter Server license is not included. So, you need to order separately.
- VMware vSphere 4 vCenter Server
UL1610-009-GL VMware vCenter Server 4 Foundation for vSphere up to 3 hosts
UL1610-00A-GL VMware vCenter Server 4 Standard for vSphere (Includes Orchestrator and Linked Mode)
When you order VMware license, please also order below support product.
UL1610-003-GL(S) 1 year support of VMware vSphere 4 Essentials Bundle for 3 hosts
UL1610-004-GL(S) 1 year support of VMware vSphere 4 Essentials Plus Bundle for 3 hosts
UL1610-005-GL(S) 1 year support of VMware vSphere 4 Standard for 1 processor (Max 6 cores per CPU)
UL1610-006-GL(S) 1 year support of VMware vSphere 4 Advanced for 1 processor (Max 12 cores per CPU)
UL1610-007-GL(S) 1 year support of VMware vSphere 4 Enterprise for 1 processor (Max 6 cores per CPU)
UL1610-008-GL(S) 1 year support of VMware vSphere 4 Enterprise Plus for 1 processor (Max 12 cores per CPU)
UL1610-009-GL(S) 1 year support of VMware vCenter Server 4 Foundation for vSphere up to 3 hosts
UL1610-00A-GL(S) 1 year support of VMware vCenter Server 4 Standard for vSphere
(Includes Orchestrator and Linked Mode)
1st Edition August ’10
Page 14
System Configuration Guide
NEC Express5800/R320a-E4/M4
Storage
Configuration
Direct connection :
Fibre Channel Controller kit
[N8803-035]
Fibre Channel Cable set
[NF9320-SJxx]
NEC Storage:
-D3-10/D4-30/D8-10/
D8-20/D8-30/E1-10
PCI-Ex Slot
1 logical slot
Connection via Fiber Channel switch:
Fibre Channel Controller kit
(4Gb/Optical) [N8803-035]
Fibre Channel Cable set
[NF9320-SJxx]
PCI-Ex Slot
1 logical slot
SFP module
[NF9330-SF02]
WB210E/WB230E FC switch
[NF9330-SSxx]
SFP module
[NF9330-SF02]
SFP module
[NF9330-SF02]
WB210E/WB230E FC switch
[NF9330-SSxx]
SFP module
[NF9330-SF02]
Fibre Channel Cable set
[NF9320-SJxx]
NEC Storage:
-D3-10/D4-30/D8-10/
D8-20/D8-30/E1-10
Product List
Fibre Channel controller:
N8803-035
Fibre Channel controller kit (4Gb/Optical)
A pair of controller, PCI Express x8
Fibre Channel swith/SFP module:
NF9330-SS07E
NF9330-SS08E
NF9330-SF02
Cables:
WB210E Fibre Channel switch
8 ports
16 ports
WB230E Fibre Channel switch
SFP module
NF9320-SJ01E
NF9320-SJ02
NF9320-SJ03
NF9320-SJ04
Fibre Channel Cable set
Fibre Channel Cable set
Fibre Channel Cable set
Fibre Channel Cable set
A pair of cable, 5 m
A pair of cable, 10 m
A pair of cable, 20 m
A pair of cable, 50 m
1st Edition August ’10
Page 15
System Configuration Guide
NEC Express5800/R320a-E4/M4
Supported PCI cards and installable slots
R320a-E4
CPU/IO module
Low-Profile Full-Height
Slot#1 Slot #2 Slot #3 Slot #4
Product
Code
Notes
1000BASE-T 2ch board kit
Fibre Channel controller
*1
*1
N8804-007
N8803-035
X
X
X
X
-
-
-
-
*1: Be sure to install a pair of controller on the same slot# of both of CPU/IO modules
R320a-M4
CPU/IO module
Low-Profile Full-Height
Slot#1 Slot #2 Slot #3 Slot #4
Product
Code
Notes
1000BASE-T 2ch board kit
Fibre Channel controller
*1
*1
N8804-007
N8803-035
X
X
X
X
X
X
X
X
*1: Be sure to install a pair of controller on the same slot# of both of CPU/IO modules
1st Edition August ’10
Page 16
System Configuration Guide
NEC Express5800/R320a-E4/M4
UPS
[Note]
- Be sure to manage the UPS via network with Network shutdown software. The UPS can
not be managed via serial port and USB port with Power Chute Plus software.
Configuration
Non-Redundant configuration :
Power cord
Power
socket
APC UPS (3000 or 5000VA)
2 connectors
Network HUB
Network management Card
RJ-45
connector
APC UPS (1500VA)
Redundant configuration :
Network management Card
Power cord
Power
socket
APC UPS (1500VA)
2 connectors
Network HUB
Network management Card
RJ-45
connector
Product List
UPS :
APC Smart-UPS 1500VA RM 2U
APC Smart-UPS 3000VA RM 3U
APC Smart-UPS RT 5000VA 208V
w/ 208V to 120V 2U Step-Down Transformer
Option :
980 Watts / 1500 VA
2700 Watts / 3000 VA
3500 Watts / 5000 VA, 5U
Network management Card
Software :
PowerChute Network Shutdown
The card managing the UPS via network, 1X 100BASE-T
Management software managing the UPS via network
1st Edition August ’10
Page 17
System Configuration Guide
NEC Express5800/R320a-E4/M4
UPS (When using Tower conversion kit)
[Note]
- Be sure to manage the UPS via network with Network shutdown software. The UPS can
not be managed via serial port and USB port with Power Chute Plus software.
Configuration
Non-Redundant configuration :
Power cord
Power
socket
APC UPS (3000VA)
2 connectors
Network HUB
Network management Card
RJ-45
connector
APC UPS (1500VA)
Redundant configuration :
Network management Card
Power cord
Power
socket
APC UPS (1500VA)
2 connectors
Network HUB
Network management Card
RJ-45
connector
Product List
UPS :
APC Smart-UPS 3000VA
APC Smart-UPS 1500VA
Option :
2700 Watts / 3000 VA
980 Watts / 1500 VA
Network management Card
Software :
PowerChute Network Shutdown
The card managing the UPS via network, 1X 100BASE-T
Management software managing the UPS via network
1st Edition August ’10
Page 18
System Configuration Guide
NEC Express5800/R320a-E4/M4
Guest OS license
[Note]
- Guest Operating Systems supported on NEC Express5800/ft series are the same as other
general purpose servers.
VMware vSphere Client
[Note]
- For maintenance of VMware ESX on the FT server, a dedicated terminal which satisfies
the following requirements is needed.
266MHz or faster x86 processor (Intel, AMD)
(500MHz recommended)
CPU
Memory
Minimum 200MB
1GB free disk space for a complete installation, which includes the following
components:
- Microsoft .NET 2.0
- Microsoft .NET 3.0 SP1
- Microsoft Visual J#
Disk
- vSphere Client 4.0
- vSphere Host Update Utility 4.0
You must also have 400MB free on the drive that has your %temp% directory.
If all of the prerequisites are already installed, 300MB of free space is required
on the drive that has your %temp% directory, and 450MB is required for the
vSphere Client 4.0.
Windows Server 2003 SP1 32bit
Windows Server 2003 SP2 32bit
Windows Server 2003 R2 32bit
Windows Server 2003 64bit
Windows Server 2008 Standard
Windows Server 2008 Enterprise
Windows Server 2008 Datacenter
Windows Server 2008 Standard 64bit
Windows Server 2008 Enterprise 64bit
Windows Server 2008 Datacenter 64bit
Windows XP Professional SP2
Windows XP Professional SP3
Windows XP Professional SP2 64bit
Windows Vista Business
OS
Windows Vista Enterprise
Windows Vista Business 64bit
Windows Vista Enterprise 64bit
NIC
1Gbps recommended
1st Edition August ’10
Page 19
System Configuration Guide
NEC Express5800/R320a-E4/M4
NEC Storage management server
[Note]
- Required for NEC Storage Manager for NEC storage management.
Backup server
[Note]
- Dedicated server for data backup is recommended
NEC ESMPRO Agent
[Note]
- R320a VMware model does not include the NEC ESMPRO Agent for VMware.
Download from ITPF portal site.
1st Edition August ’10
Page 20
2. Local Procurement
2.1 Hardware/software components
The following table shows the status whether the local procurements are allowed according to
each component. You need to purchase the components provided by NEC, if the status
indicates ‘NO’.
Components
Status
CPU
No
No
Memory
Hard disk drive
LAN controller
No
No
KVM switch(USB,PS/2 port)
Keyboard (USB)
Mouse (USB)
No
No
Yes
Yes
Yes
Yes
Server Rack
UPS
UPS management software
2.2 Power cord
No power cord is attached to the products listed below. You must obtain the cables from local
suppliers. Note that the cords to be purchased should meet the specifications below.
And to use the server switch unit, you may have to purchase a local AC adapter or power cord,
depending on the country you live in. The connector type required for the AC adapter is
IEC320.
Product code
Product name
Standard Input
100-120VAC
220-240VAC
N8800-149F
N8800-150F
N8191-10F
Express5800/R320a-E4
12.0A
12.0A
0.12A
6.0A
6.0A
0.08A
Express5800/ R320a-M4
Server Switch Unit(8Server/USB)
2-1
|