NEC Display Solutions of America, Inc.
M300WS Installation Guide
Ceiling Mounted and Desktop
Rev 1.2
Contents
Product Description, Lens Specs, Notes and Formulas
Diagrams & Distance Charts
Cabinet Dimensions
Ceiling Mount Dimensions
Input Panel and Control Codes
Pg 1
Pg 2
Pg 3-4
Pg 5
Pg 6
Product Description
Type:
3 panel LCD projector,
0.59” p-Si TFT w/MLA
Dimensions:
Weight:
15.7” (W) x 5.5” (H) x 12.2” (D)
8.8 lbs
Resolution: 1280 x 800
Brightness: 3000 Lumens
Fan Noise:
36 dB / 30dB @ 1 meter
BTU’s:
1222 BTU/hour
Power Consumption: 358W (max)
Lens Specifications
Throw Ratio:
Offset Angle:
Screen Sizes:
0.48:1 (for 100” diagonal)
Focal Length:
F/#:
Manual Focus
17.5mm – 29.0mm
1.7 - 2.1
37.3° (for 100” diagonal)
56.2” - 104” diagonal (16:10)
Notes
.
For screen sizes not indicated on the projection tables, use the formulas below.
If the figures on the tables do not match the results of formulas, use the figures in the table.
All calculations are based on a 4:3 aspect ratio.
Distances are in inches, for millimeters multiply by 25.4.
Distances may vary 5%.
Formulas
The Projection Formulas use the image width for calculation. For proper projection placement, determine the image width
for the desired screen size. Use the Screen Formulas below to calculate all screen dimensions. Plug in the width for “W” in
the Projection Formulas.
Refer to the diagrams and charts for popular screen sizes on page 2:
Definitions:
W = Image Width
16:10 Screen Formulas:
W = H x 16/10
H = Image Height (size)
H = W x 10/16
B = Vertical distance between lens center and screen center
C = Throw distance
Screen Diagonal = W x 18.868/16
D = Vertical distance between lens center and screen top
(screen bottom for desktop application)
α = Throw Angle
Projection Formulas:
B = 0.375W
C = 0.48W (wide)
D = 0.0625W
α = tan-1(B/C)
M300WS
Page 1 of 6
NEC Display Solutions of America, Inc.
M300WS Installation Guide
Ceiling Mounted and Desktop
Rev 1.2
Cabinet Dimensions
The following drawings show the cabinet dimensions.
Dimensions are in inches. For millimeters multiply by 25.4.
M300WS
Page 3 of 6
NEC Display Solutions of America, Inc.
M300WS Installation Guide
Ceiling Mounted and Desktop
Rev 1.2
Cabinet Dimensions (continued)
The following drawings show the cabinet dimensions.
Dimensions are in inches. For millimeters multiply by 25.4.
M300WS
Page 4 of 6
NEC Display Solutions of America, Inc.
M300WS Installation Guide
Ceiling Mounted and Desktop
Rev 1.2
Optional Ceiling Mount Dimensions (Model #: MP300CM)
The following drawings show the ceiling mount dimensions.
Dimensions are in inches. For millimeters multiply by 25.4.
M300WS with Optional Ceiling Mount (Model #: MP300CM)
M300WS with Optional Long Throw Mount (Model #: NPLTWM)
3.00
No Offset from Center
M300WS
Page 5 of 6
NEC Display Solutions of America, Inc.
M300WS Installation Guide
Ceiling Mounted and Desktop
Rev 1.2
Input / Output Panel
PC Control Codes
Function
Code Data
POWER ON
02H
02H
02H
02H
02H
02H
02H
02H
02H
02H
02H
02H
02H
02H
00H
00H
03H
00H
01H
03H
03H
03H
03H
03H
03H
03H
03H
10H
11H
12H
13H
00H
00H
00H
00H
00H
00H
00H
00H
00H
00H
00H
00H
00H
00H
00H
00H
00H
00H
00H
00H
00H
00H
00H
00H
00H
00H
00H
00H
00H
00H
00H
00H
00H
02H
02H
02H
02H
02H
02H
02H
02H
00H
00H
00H
00H
01H
00H
00H
02H
03H
01H
01H
01H
01H
01H
01H
01H
01H
12H
13H
14H
15H
02H
88H
8DH
POWER OFF
INPUT SELECT COMPUTER1
INPUT SELECT COMPUTER2
INPUT SELECT HDMI
01H
02H
09H
0AH
1AH 22H
06H 0EH
INPUT SELECT VIDEO
INPUT SELECT S-VIDEO
INPUT SELECT VIEWER
INPUT SELECT NETWORK
INPUT SELECT USB DISPLAY
PICTURE MUTE ON
0BH 13H
1FH 27H
20H
22H
28H
2AH
PICTURE MUTE OFF
SOUND MUTE ON
SOUND MUTE OFF
PROJECTOR INFORMATION REQUEST
ERROR STATUS REQUEST
INFORMATION REQUEST
Note: Contact your NEC rep for codes not listed.
BFH 00H
88H 00H
8AH 00H
C2H
Cable Connection
To TxD of PC
To RxD of PC
To GND of PC
Communication Protocol:
Baud Rate:
Data Length:
Parity:
Stop Bit:
X on/off:
38400 bps
8 bits
No Parity
One Bit
None
1
2
3
4
5
6
7
8
9
Communications: Full duplex
To RTS of PC
To CTS of PC
PC Control Connector (D-Sub 9P)
NOTE 1 : Pins 1, 4, 6, and 9 are used inside the projector.
NOTE 2: For long cable runs it is recommended to set communication speed within the projector to 9600 bps.
NOTE 3: Jumper “Request to Send” and “Clear to Send” together on both ends of the cable to simplify cable connection.
M300WS