Manitowoc Ice Air Compressor C 0200 User Manual

C, E, & H-0200 COMPRESSOR REPLACEMENT ASSEMBLIES  
Installation Instructions  
Item  
1
Qty.  
1
1
1
2
Description  
P/N  
6635214  
6264614  
5202093  
Compressor Adapter Plate  
Component Mounting Bracket  
#10-24 x 1/2 Thread Cutting Screw  
#8 Flat Head Sheet Metal Screw  
Lead Wires  
2
3
4
5
5025553  
6
2075623, 2075633, 2075643, 2075653, 2075663, 2075673  
6
7
8
9
1
1
2
2
Installation Instructions  
Wire Shield  
#10-24 Hex Nuts  
#10 Lockwashers  
Extruded Tape 7 1/4” Long  
8002233  
6278414  
5429291  
5573163  
9202483  
10  
1
ON C, E, & H-0200 SERIES ICE MACHINES  
To replace a Tecumseh compressor with a B/M number of AK159AT-032-H4, AK159ET-032-H4, or AK163JT-032-C4, items 1  
through 5 are not required. All components are directly replaceable.  
To replace a Tecumseh compressor with a B/M number of AE256AT-681-A4, AE334JT-616-A4, or AE255ET-616-A4, all the items  
are required. Follow the instructions below:  
1. After the old compressor has been removed, fasten down the compressor adapter plate to the ice machine base. Locate by  
using the four weldstuds, lockwashers, and hexnuts from the old compressor mounting.  
2. Mount the new start capacitor and start relay to the component mounting bracket, as shown. Mount this component and  
bracket assembly on the adapter plate. Locate over the two outside weldstuds, with the components facing out, as shown.  
3. Install the new compressor with existing sleeves, grommets, lockwashers, and hexnuts. Note: The compressor should be  
located so that the electrical hookup box is facing the inside of the ice machine.  
4. New compressor refrigeration ports are not located in the same position as the original compressor refrigeration ports.  
Repiping will be required.  
5. Using supplied wires, wire the:  
compressor protector “3” to toggle switch “17”  
start relay “L” to transformer board “19”  
start relay “M” to compressor “R”  
start capacitor to compressor “S”  
start relay “S” to start capacitor  
6. Important: Change the numerical marking for the compressor protector on the existing wiring diagram (on front panel label)  
to correspond with the new compressor (change the 3 to a 1 and the 1 to a 3).  
7. On 50 Hz., 230V machines, remove the crankcase pressure regulator valve (CPR valve).  
8. Apply wire shield (see illustration on bottom of page) to existing protruding screws of the ice machine base. Apply tape, as  
shown on illustration.  
Manitowoc Ice, Inc.  
2110 South 26 Street, P.O. Box 1720, Manitowoc, WI 54221-1720 USA  
Telephone 920-682-0161, Fax - Sales: 920-683-7589, Service/Parts: 920-683-7585, Other: 920-683-7879  
8002233  
Rev. 03/30/99  
 

Kustom Stereo Amplifier WAV 212 User Manual
KWC Indoor Furnishings 12253151006 User Manual
La Crosse Technology Clock WS 8418U IT User Manual
Lennox Hearth Stove CI2000HT User Manual
Lenovo Laptop G460 User Manual
LG Electronics Range LRE3091 User Manual
LST Network Card RL58 1 User Manual
Mackie Musical Instrument Srm150 User Manual
Marantz Stereo System SR 3000 User Manual
Memorex DVD Player MVD2047 User Manual