DCS 6000
User Manual
Digital Conference System
PS 6000 Power Supply
Danish Interpretation Systems
DIS
Danish Interpretation Systems
User Manual
List of Contents
System design.....................................................7
List of Contents..................................................... 3
Important .............................................................. 4
Use of PS 6000 ................................................8
System Setup..........................................................9
General guidelines .............................................9
Compliancy........................................................ 4
Safety.................................................................. 4
Installation precautions.................................... 4
Cleaning & Repacking...................................... 4
Warranty ........................................................... 4
Max. number of units to be connected...........10
CM/DM 60x0P Chairman/Delegate Units.....10
CM/DM 60x0P Chairman/Delegate Units & JB
6002 Junction Box .........................................10
Description of the DCS 6000 system ................... 5
Features.............................................................. 5
CM/DM 6060F/6510F Chairman/Delegate
Units...............................................................11
CM/DM 6560F Chairman/Delegate Units.....11
System components........................................... 6
MU 6040 C/D without connected loudspeaker
.......................................................................12
Central equipment etc...................................... 6
Interpreter equipment...................................... 6
Voting equipment............................................ 6
Conference equipment and channel selectors . 6
IS 6132P Interpreter Units .............................12
IS 6132P w/JB 6004 and LS 6032.................13
CS 6032F Channel Selector w/back light on .13
Operating instructions ......................................... 7
Appendix..............................................................14
PS 6000 Power Supply...................................... 7
Technical appendix..........................................14
General description ......................................... 7
Cabling...........................................................14
Features ........................................................... 7
Connectors....................................................... 7
Accessories (not supplied).............................14
Technical specifications.................................14
Copyright © 2007 DIS
PS6000 REV B.DOC
21-05-2007
No part of this publication may be reproduced or utilised in any form or by any means without permission in writing from the
publisher.
Danish Interpretation Systems
User Manual
Important
The equipment must be connected to earth
Compliancy
Installation precautions
The equipment has been tested and found to comply
with the limits of the following standards for digital
devices:
Allow adequate air circulation to prevent internal
heat built-up. Do not place the unit on a surface
(rugs, blankets, etc.) that may block the ventilation
holes.
•
•
•
•
•
EN55103-1 (Emission)
EN55103-2 (Immunity
EN60065 safety
UL6500 safety
FCC rules part 15, class A (Emission)
Do not install the unit in a location near heat
sources such as radiators or air ducts, or in a place
exposed to direct sunlight, excessive dust or
humidity, mechanical vibration or shock.
This device complies with part 15 of the FCC rules.
Operation is subject to the following conditions: (1)
This device may not cause harmful interference,
and (2) this device must accept any interference
received, including interference that may cause
undesired operation.
To avoid moisture condensations do not install the
unit where the temperature may rise rapidly.
When installing the unit inside a 19” rack, observe
that the rack is properly ventilated. The maximum
allowed temperature inside the rack is 40 °C.
These limits are designed to provide reasonable
protection against harmful interference when the
equipment is operated in residential, commercial or
light industrial environments. The equipment
generates, uses, and can radiate radio frequency
energy and if not installed and used in accordance
with the user manual it may cause harmful
interference to radio communications.
Cleaning & Repacking
To keep the cabinet in its original condition,
periodically clean it with a soft cloth. Stubborn
stains may be removed with a cloth lightly
dampened with a mild detergent solution. Never use
organic solvents such as thinners or abrasive
cleaners since these will damage the cabinet.
You are cautioned that any changes or
modifications not expressly approved in this manual
could void your authority to operate this equipment.
Save the original shipping cardboard box and
packing material; they will become handy if you
ever have to ship the unit. For maximum protection,
re-pack the unit as originally packed from the
factory.
Safety
Check that the voltage of your local power supply is
within the operating voltage of the unit (100-240V
AC). If a voltage conversion is required, consult
your DIS dealer or qualified personnel.
Warranty
The unit is minimum covered by 12 months
warranty against defects in materials or work-
manship.
Should any liquid or solid object fall into the
cabinet, unplug the unit and have it checked by
qualified personnel before operating it further.
Set the Power switch to OFF if it is not used for
several days.
Manual 01 18 04450
4
Danish Interpretation Systems
User Manual
Description of the DCS 6000 system
•
Added functionality and comprehensive
features provided by SW 6000 software
package running on PC
Features
The DCS 6000 system has the following main
features:
RS232/RS422 connection on CU 6005/6010 for
external operation of the system of a PC or
control system such as AMX or Crestron
•
•
•
Fully digital
Excellent sound quality
The SW 6000 is an optional software package,
which expands the functionality of the DCS 6000
system. The software runs on standard computer
technology (Standard PC with Windows 2000 or
XP).
“State of the Art” fully digital integrated
interpretation, discussion and voting system
offering interpretation, language distribution,
conference microphone and voting facilities
with attendance check with Chip Card ™.
Main features of the SW 6000 are:
•
•
New, unique digital DATA and AUDIO bus.
•
•
•
•
•
•
•
•
Microphone management
Mimic panel operation
Interpretation management
Voting management
39 incoming channels (8 floor channels + 31
interpreted channels) and one Line input.
•
•
34 distributed channels (3 x floor + 31
interpreted channels)
Message handling
The Delegate and Interpreter units are powered
and controlled by the CU 6005 Central Unit,
which drives up to app. 50 units on 2 chains or
by the CU 6010 Central Unit, which drives up
to app. 200 units on 4 chains.
Agenda handling
Data stored on SQL data base
Web interface available for easy links to
external databases
•
•
EX 6010 Extension Units or PS 6000 Power
Supplies available if more units are required
•
•
Multi language user interfaces
A total of 4000 units (delegate and/or
interpreter units) can be connected to the
system.
Supports different User types with different
priorities, user interfaces and control
possibilities
•
•
•
Using screened CAT5 or CAT5e cabling (FTP
or STP) ensuring a very cost effective
installation and easy set-up of portable systems
•
Variety of printing facilities such as speaker’s
log, voting results, delegates list etc.
Firmware in Delegate units, Interpreter Units,
Central Units etc. upgradeable through serial
PC-connection (RS232 or RS422)
Can be operated with or without a PC.
Manual 01 18 04450
5
Danish Interpretation Systems
User Manual
Conference equipment and channel
selectors
System components
The CU 6005/6010 Central Unit supports all
available units in the DCS 6000 series:
CS 6032FV/H
DM 6010P
Channel Selector (flush mounted)
Conference Unit (portable)
DM 6060P
Conference Unit (portable) with
one built-in channel selector
Central equipment etc.
EX 6010
PS 6000
AO 6004
AO 6008
RP 6004
JB 6002
JB 6004
Extension Unit
Power Supply
Audio Output box
Audio Output box
Repeater for four chains
Junction Box with 2 outputs
Junction Box with 4 outputs
CM/DM 6070P Conference Unit (portable) with
two built-in channel selectors
CM/DM 6090P Conference Unit (portable) with
two built-in channel selectors and
XLR microphone connector
CM/DM 6060F Conference Unit (flush mounted)
with one built-in channel
selectors
CM/DM 6510F Conference Unit (flush mounted)
with Chip-card and 3 voting
buttons
CM/DM 6560F Conference Unit (flush mounted)
with one built-in channel
selector, Chip-card and 3 voting
buttons
Interpreter equipment
IS 6132P
LS 6132P
Interpreter Set
Interpreter Loudspeaker
Voting equipment
MU 6040C/D
Microphone Unit for use with
customised front plate with
Loudspeaker, Microphone and
Buttons. Available in Delegate
(D) and Chairman (C) version
DV 6501F Voting Unit
MU 6042D
AM 6040
Dual Microphone Unit for use
with FD/FC front plate with
Loudspeaker, Microphone and
two delegate Buttons
Ambient Noise Microphone
Manual 01 18 04450
6
Danish Interpretation Systems
User Manual
Operating instructions
PS 6000 Power Supply
•
•
Delayed switching on of power to minimise the
total ‘switch-on’ current on the Mains supply.
General description
The PS 6000 Power Supply provides additional
Power for the DCS 6000 system.
Designed in a small size easy-to-install cabinet.
One CU 6005/6010 Central Unit is needed in each
DCS 6000 system; however for expansion of the
system the PS 6000 Power Supply is suitable. The
PS 6000 consists of:
Connectors
The PS 6000 Power Supply features the following
connectors:
•
•
One Power Supply
ꢀ
Power connector
Connection for main power.
Control electronic for detecting system power
ꢀ
Loop through connectors
Features
RJ45 connector, 2 pieces
The main features of the PS 6000 Power Supply
are:
DCS-LAN connectors used for connection to the
CU 6005/6010 and for connection to other units
with DCS-LAN connectors such as more PS 6000.
•
•
•
Built in Power Supply for app 60 units
(Delegates) or app. 150 Channel Selectors
ꢀ
Power LED
One connector for connection to Delegate
Units, Interpreter Units etc.
Those green LED light up when Power is available
on the connector next to the LED.
One connector for connection previous unit (i.e.
CU 6005/6010.
System design
There are no settings to be done on the PS 6000
Power Supply.
And the PS 6000 is NOT a repeater, which means
that the maximum cable length in a chain (which
without repeater is 200 m) has to be calculated from
the last unit with repeater functionality (typically a
CU 6005/6010, EX 6010 or RP 6004) to the last
unit connected to the PS 6000.
However it is important to observe, that the unit is
only adding power to one of the chains on the CU
6005/6010 Central Unit.
And as so, the specification, which applies the two
chain outputs on the CU 6005 Central Unit and to
each of the chain outputs on the CU 6010 Central
Unit, does also apply to the output on the PS 6000.
This includes interconnection cables between the
units.
Manual 01 18 04450
7
Danish Interpretation Systems
User Manual
Use of PS 6000
The PS 6000 can be inserted at any point in a DCS
6000 chain, where extra power is needed. The PS
6000 is used, when extra power is needed typically,
where long feeding cables are needed.
A typical application is to place a PS 6000 in the
first Interpreter Booth to compensate for a long
feeding cable.
The following schematic shows various ways in
how to use the PS 6000 Power Supply:
Manual 01 18 04450
8
Danish Interpretation Systems
User Manual
System Setup
General guidelines
Connect the PS 6000 to the various DCS 6000 units
using Cat5 or Cat5e FTP or STP screened cables.
Please observe the following guidelines:
between the units are short, more units can
be connected than if the feeding cable is
long and/or the cables are long between the
units. Please consult the next section (Max.
Number of units to be connected)
•
Maximum cable length in one chain is 200
without repeater. This includes
m
interconnection cables between the units.
The max. usable cable length depends on
the units connected and length of feeding
cables etc.
•
If the last unit in one chain is a CS 6032
Channel Selector, this unit has to be
terminated with an external termination, as
the CS 6032 does not have an internal
termination.
•
•
Maximum cable length in one chain when
using repeaters is 650 m.
It is desirable that the square of the feeding cables
especially, but also the interconnection cables are as
big as possible to minimize the voltage drop in the
cables. Cat 5/Cat5E cables are delivered in various
gauges:
Although the output on the PS 6000 have a
125W supply, this 125W power is not all
usable with long cables, as there will be a
voltage drop in the feeding cable from the
PS 6000 to the units connected. If the
feeding cables are short and the cables
The following table is showing the Diameter/square
for various AWG types
Type
Diameter
Square
AWG22
0.64 mm
0.57 mm
0.53 mm
0.42 mm
0.32 mm2
AWG23/1
AWG24
AWG26
0.25 mm2
0.22 mm2
0.14 mm2
Manual 01 18 04450
9
Danish Interpretation Systems
User Manual
Max. number of units to be connected
The following tables show the maximum number of
units, which can be connected to the two outputs
(A1 or A2) on a CU 6005 Central Unit in total or to
each of the four outputs (A1, A2, B1 or B2) on a
CU 6010 Central Unit or to each output on an EX
6010 Extension Unit or to the output of a PS 6000
Power Supply.
CM/DM 60x0P Chairman/Delegate Units
Length of Feeding Cable
Type CAT5 AWG24
Length of inter connecting
Cable, Type CAT5 AWG24
Total cable length
Max. number of CM/DM
60x0 pr output
10 m
30 m
50 m
100 m
150 m
10 m
30 m
50 m
100 m
150 m
1 m
1 m
1 m
1 m
1 m
2 m
2 m
2 m
2 m
2 m
51 m
67 m
83 m
123 m
165 m
88 m
42
38
34
24
16
40
35
30
22
16
98 m
108 m
142 m
180 m
CM/DM 60x0P Chairman/Delegate Units & JB 6002 Junction Box
This configuration shows two CM/DM 60x0
Delegate/Chairman Units connected to one JB 6002
Junction Box with 3m cables between each JB
6002. Maximum 5 m cable from JB 6002 to
CM/DM 60x0 and max. one CM/DM 60x0 on each
output of JB 6002.
Length of Feeding Cable, Length of Cable between each Total cable
Number of
JB 6002
Max. number of
DM 60x0
Type CAT5 AWG24
JB 6002, Type CAT5 AWG24
length
10 m
30 m
50 m
100 m
150 m
3 m
3 m
3 m
3 m
3 m
61 m
75 m
89 m
127 m
168 m
18
16
14
10
7
36
32
28
20
14
Manual 01 18 04450
10
Danish Interpretation Systems
User Manual
CM/DM 6060F/6510F Chairman/Delegate Units
The following tables show the maximum number of
units, which can be connected to the two outputs
(A1 or A2) on a CU 6005 Central Unit in total or to
each of the four outputs (A1, A2, B1 or B2) on a
CU 6010 Central Unit or to each output on an EX
6010 Extension Unit or to the output of a PS 6000
Power Supply.
Length of Feeding Cable
Type CAT5 AWG24
Length of inter connecting
Cable, Type CAT5 AWG24
Total cable length
Max. number of
CM/DM 60x0 pr output
10 m
30 m
50 m
100 m
150 m
10 m
30 m
50 m
100 m
150 m
1 m
1 m
1 m
1 m
1 m
2 m
2 m
2 m
2 m
2 m
39 m
56 m
73 m
115 m
160 m
64 m
78 m
94 m
130 m
170 m
30
27
24
16
11
28
25
23
16
11
CM/DM 6560F Chairman/Delegate Units
Length of Feeding Cable
Type CAT5 AWG24
Length of inter-connecting
Cable, Type CAT5 AWG24
Total cable length
Max. number of CM/DM
60x0 pr output
10 m
30 m
50 m
100 m
150 m
10 m
30 m
50 m
100 m
150 m
1 m
1 m
1 m
1 m
1 m
2 m
2 m
2 m
2 m
2 m
35 m
53 m
70 m
113 m
159 m
58 m
72 m
88 m
126 m
166 m
27
24
21
14
10
25
22
20
14
9
Manual 01 18 04450
11
Danish Interpretation Systems
User Manual
MU 6040 C/D without connected loudspeaker
This table shows the maximum number of MU
6040 Microphone Units, which can be connected.
The numbers are with no audio in loudspeaker (no
loudspeaker connected to each unit). If
loudspeakers are used, then use the figures for
CM/DM 60x0 above.
Length of Feeding Cable, Cable length between
Total cable length
Max. number of
MU 6040
Type CAT5 AWG24
each MU 6040
10 m
30 m
50 m
100 m
150 m
100 m
150 m
2 m
2 m
2 m
2 m
2 m
1 m
1 m
168 m
178 m
188 m
80
75
70
200 m (202 m)
200 m (232 m)
151 m
51 (52*)
26 (42*)
52
191 m
42
Numbers in (‘) are the number of units, which could
have been connected CU/EX, but where the total
number of units has been lowered due to the
restriction of the maximum length of cable (200 m).
IS 6132P Interpreter Units
This table shows the maximum number of IS 6132P
Interpreter Sets, which can be connected. The
numbers are with no audio in loudspeaker (no
loudspeaker connected to each unit).
Note: The number of units is dependant of how
many interpreter sets there are per booth (or
language), as there only can be one set switched ON
per language (channel).
If loudspeakers are used, then use the figures for
CM/DM 60x0 above.
Length of Feeding Cable,
Type CAT5 AWG24
Length of inter-connecting Cables,
Type CAT5 AWG24
Max. number of units pr output
All ON ½ ON 1/3 ON
10m
30m
50m
100m
150m
2 m
2 m
2 m
2 m
2 m
54
49
44
35
25
x
x
60
x
x
x
57
51
40
30
Manual 01 18 04450
12
Danish Interpretation Systems
User Manual
IS 6132P w/JB 6004 and LS 6032
Length of Feeding Cable,
Type CAT5 AWG24
Length of cable
between booths
Number of
booths
Number of
IS 6132/ booths
Number of
LS 6032/ booths
10 m
10 m
30 m
30 m
50 m
5 m
5 m
5 m
5 m
5 m
5 m
5 m
5 m
5 m
5 m
19
12
17
10
15
9
11
7
8
4
4
4
4
4
4
4
4
4
4
0
4
0
4
0
4
0
4
0
4
50 m
100 m
100 m
150 m
150 m
5
CS 6032F Channel Selector w/back light on
Length of Feeding Cable
Type CAT5 AWG24
Length of Inter-connecting Total cable length Max. number of CS 6032 pr
cable, Type CAT5 AWG24
output
30 m
50 m
100 m
150 m
10 m
30 m
50 m
100 m
150 m
1 m
1 m
1 m
1 m
2 m
2 m
2 m
2 m
2 m
139 m
144 m
184 m
200 m
200 m
200 m
200 m
200 m
200 m
110
95
85
51 (67’)
96
86 (90’)
76 (85’)
51 (70’)
26 (60’)
Numbers in (‘) are the number of units, which could
have been connected to the CU/EX, but where the
total number of units has been lowered due to the
restriction of the maximum length of cable (200 m).
Manual 01 18 04450
13
Danish Interpretation Systems
User Manual
Appendix
Technical appendix
Pair 1: Pin 1 & 2
Pair 2: Pin 3 & 6
Pair 3: Pin 4 & 5
Pair 4: Pin 7 & 8
Cabling
CAT5
The DCS 6000 system uses CAT5, CAT5e or
CAT6 FTP or STP cables with screened RJ45
connectors.
The phase of the pairs must be correct and the
wiring spec. as stated in CAT5 (EIA 568-B) have to
be followed.
EIA 568-B wiring shall be used.
It is important to use only FTP or STP
(screened) cables and screened RJ45 connectors
and not UTP cable, which is unscreened.
Note: CAT6 cables can normally only be
terminated in sockets (female) and not in cable
plugs.
How to wire a CAT5 (EIA 568-B) Cable:
CAT6 can thus only be used for longer cable draws
terminating in wall outlets or patch panels.
Pin Function
Connector #1 Connector #2
1
2
3
4
5
6
7
8
In-going + ORG/WHT
ORG/WHT
ORG
GRN/WHT
BLU
BLU/WHT
GRN
Accessories (not supplied)
In-going -
+48V
0V
ORG
GRN/WHT
BLU
Cat 5e Connection Cables (AWG24)
EC 6000-..5 Connection Cable 0.5 m......................10 03 12500
EC 6000-01 Connection Cable 1 m.........................10 03 13101
EC 6000-02 Connection Cable 2 m.........................10 03 13201
EC 6000-05 Connection Cable 5 m.........................10 03 13501
EC 6000-10 Connection Cable 10 m.......................10 03 14102
EC 6000-20 Connection Cable 20 m.......................10 03 14202
EC 6000-50 Connection Cable 50 m.......................10 03 14502
0V
+48V
BLU/WHT
GRN
Outgoing - BRN/WHT
Outgoing + BRN
BRN/WHT
BRN
Note. If other colour codes are used then the four
pairs are connected as follows:
Technical specifications
Weight..................................................................................1 kg
Dimensions (W x H x D).................... 100 (125) x 50 x 205 mm
Dimensions in bracket are including the fixing bracket
Accessories supplied.................................................Main cable
Connectors
General
Power consumption .................................................max. 150W
Mains voltage: ........................................100 - 240V, 50...60Hz
Supply voltage for units............................................ 48V/125W
Temperature to guarantee specified performance
DCS-LAN loop through....................................... 2 pieces RJ45
Specifications are subject to change without notice.
..............................5 Deg C. to 40 Deg C. (35 to 80% humidity)
Storage temperature
.......................... -20 Deg C. to 60 Deg C. (10 to 80% humidity)
Manual 01 18 04450