Leica Laser Level 776748 User Manual

D
EN  
F
User Manual  
Safety Instructions  
Symbols used  
English  
The symbols used in the Safety Instructions have the  
following meanings:  
Congratulations on the purchase of your  
Leica DISTO™ D330i .  
I
WARNING:  
Indicates a potentially hazardous situation or  
an unintended use which, if not avoided, will result in  
death or serious injury.  
Carefully read the Safety Instruc-  
E
ƽ
tions and the User Manual before  
P
using this product.  
The person responsible for the instrument must  
ensure that all users understand these directions and  
adhere to them.  
NL  
DK  
S
CAUTION:  
ƽ
Indicates a potentially hazardous situation or  
an unintended use which, if not avoided, may result  
in minor injury and/or in appreciable material, finan-  
cial and environmental damage.  
Contents  
Safety Instructions .............................................1  
Start-up................................................................6  
Menu functions...................................................9  
Operation...........................................................11  
Measuring ..........................................................12  
Functions...........................................................13  
Working with BLUETOOTH® ............................19  
Appendix............................................................20  
N
Important paragraphs which must be adhered  
)
to in practice as they enabled the product to be used  
FIN  
J
in a technically correct and efficient manner.  
Use of the instrument  
CN  
ROK  
PL  
H
Permitted use  
Measuring distances  
Computing functions, e. g. areas and volumes  
Storing measurements (BLUETOOTH®)  
Measuring tilts  
RUS  
CZ  
Leica DISTO™ D330i 776751 en  
1
Safety Instructions  
 
To understand the safety instructions on the  
product and the instructions in the User Manual.  
To be familiar with local safety regulations  
relating to accident prevention.  
failure due to installed safety measures (e.g. safety  
limit switch), it is assured that no damage will occur.  
D
EN  
F
WARNING:  
Flat batteries must not be disposed of with  
household waste. Care for the environment and take  
them to the collection points provided in accordance  
with national or local regulations.  
ƽ
To inform Leica Geosystems immediately if the  
equipment becomes unsafe.  
I
Hazards in use  
E
The product must not be disposed of with  
household waste.  
Dispose of the product appropriately in  
accordance with the national regulations in  
force in your country.  
Always prevent access to the product by  
unauthorized personnel.  
CAUTION:  
P
ƽ
Watch out for erroneous distance measure-  
ments if the instrument is defective or if it has been  
dropped or has been misused or modified.  
NL  
DK  
S
Precautions:  
Carry out periodic test measurements. Particularly  
after the instrument has been subject to abnormal  
use, and before, during and after important measure-  
ments.  
Product specific treatment and waste  
management information can be downloaded from  
the Leica Geosystems home page at  
received from your Leica Geosystems dealer.  
N
FIN  
J
Make sure the Leica DISTO™ optic is kept clean and  
that there is no mechanical damage to the bumpers.  
CAUTION:  
ƽ
CN  
ROK  
PL  
H
Electromagnetic Compatibility  
(EMC)  
The term "electromagnetic compatibility" is taken to  
mean the capability of the product to function  
smoothly in an environment where electromagnetic  
radiation and electrostatic discharges are present,  
and without causing electromagnetic interference to  
other equipment.  
In using the instrument for distance measure-  
ments or for positioning moving objects (e.g. cranes,  
building equipment, platforms, etc.) unforeseen  
events may cause erroneous measurements.  
Precautions:  
Only use this product as a measuring sensor, not as  
a control device. Your system must be configured and  
operated in such a way, that in case of an erroneous  
measurement, malfunction of the device or power  
RUS  
CZ  
Leica DISTO™ D330i 776751 en  
3
Safety Instructions  
 
WARNING:  
Connect the equipment into an outlet on a circuit  
different from that to which the receiver is  
connected.  
Consult the dealer or an experienced radio/TV  
technician for help  
D
EN  
F
ƽ
The Leica DISTO™ conforms to the most strin-  
gent requirements of the relevant standards and  
regulations. Yet, the possibility of it causing interfer-  
ence in other devices cannot be totally excluded.  
WARNING:  
CAUTION:  
I
ƽ
ƽ
Changes or modifications not expressly  
Never attempt to repair the product yourself. In  
approved by Leica Geosystems for compliance could  
void the user’s authority to operate the equipment.  
E
case of damage, contact the local dealership.  
P
FCC statement (applic. in U.S.)  
Use of the product with  
BLUETOOTH®:  
WARNING:  
Electromagnetic radiation can cause distur-  
bances in other equipment, in installations (e.g.  
medical ones such as pacemakers or hearing aids)  
and in aircraft. It can also affect humans and animals.  
This equipment has been tested and found to comply  
with the limits for a Class B digital device, pursuant to  
part 15 of the FCC Rules. These limits are designed to  
provide reasonable protection against harmful inter-  
ference in a residential installation.  
NL  
DK  
S
ƽ
This equipment generates, uses and can radiate radio  
frequency energy and, if not installed and used in  
accordance with the instructions, may cause harmful  
interference to radio communications.  
However, there is no guarantee that interference will  
not occur in a particular installation.  
If this equipment does cause harmful interference to  
radio or television reception, which can be deter-  
mined by turning the equipment off and on, the user  
is encouraged to try to correct the interference by  
one or more of the following measures:  
N
FIN  
J
Precautions:  
Athough this product conforms to the most stringent  
standards and regulations, Leica Geosystem cannot  
totally exclude the possibility of harm to people and  
animals.  
CN  
ROK  
PL  
H
Do not use the product near petrol stations,  
chemical plants, in areas with a potentially explo-  
sive atmosphere and where blasting takes place.  
Do not use the product near medical equipment.  
Do not use the product in airplanes.  
Reorient or relocate the receiving antenna.  
Increase the separation between the equipment  
and receiver.  
RUS  
CZ  
Leica DISTO™ D330i 776751 en  
 
4
Safety Instructions  
Do not use the product near your body for  
extended periods.  
WARNING:  
D
EN  
F
ƽ
Looking directly into the beam with optical aids  
(e.g. binoculars, telescopes) can be hazardous.  
CAUTION:  
ƽ
Never attempt to repair the product yourself. In  
Precautions:  
Do not look directly into the beam with optical aids.  
case of damage, contact the local dealership.  
I
CAUTION:  
ƽ
Laser classification  
Looking into the laser beam may be hazardous  
E
to the eyes.  
Integrated distancemeter  
P
Precautions:  
The Leica DISTO™ produces a visible laser beam  
which emerges from the front of the instrument.  
Do not look into the laser beam. Make sure the laser  
is aimed above or below eye level. (particularly with  
fixed installations, in machines, etc.)  
NL  
DK  
S
N
FIN  
J
CN  
ROK  
PL  
H
It is a Class 2 laser product in accordance with:  
IEC60825-1 : 2007 "Radiation safety of laser  
products"  
Laser Class 2 products:  
Do not stare into the laser beam or direct it towards  
other people unnecessarily. Eye protection is  
normally afforded by aversion responses including  
the blink reflex.  
RUS  
CZ  
Leica DISTO™ D330i 776751 en  
5
Safety Instructions  
 
D
EN  
F
Labelling  
Start-up  
Inserting/replacing batteries  
Laser Radiation  
Do not stare into the beam  
Laser class 2  
acc. IEC 60825-1:2007  
I
Maximum radiant power:  
<1mW  
Emitted wavelength:  
620-690nm  
E
Beam divergence: 0.16 x 0.6 mrad  
-9  
Pulse duration:  
1 x 10  
s
P
NL  
DK  
S
N
FIN  
J
Position of the product label:  
CN  
ROK  
PL  
H
2
1
Remove battery compartment lid and attach  
handstrap.  
Insert batteries, observing correct polarity.  
Close the battery compartment again. Replace  
Complies with 21 CFR 1040.10 and 1040.11  
except for deviations pursuant to Laser Notice  
No. 50, dated June 24, 2007.  
2
3
US 5949531  
WO 0244754  
WO 9818019  
PATENTS: WO 9427164  
WO 0216964  
EP 1195617  
the batteries when the symbol  
nently in the display.  
flashes perma-  
RUS  
CZ  
Only use alkaline or rechargeable batteries.  
Remove the batteries before any long period  
TM  
)
)
Type: Leica DISTO D330i  
Power: 3V  
/
of non-use to avoid the danger of corrosion.  
Leica DISTO™ D330i 776751 en  
 
6
Start-up  
D
EN  
F
Changing the reference point  
(multifunctional endpiece)  
Keypad  
1
2
I
13  
11  
4
E
3
10  
5
P
The instrument can be adapted for the following  
measuring situations:  
NL  
DK  
S
6
8
9
7
12  
N
FIN  
J
1
2
3
4
5
6
7
8
9
ON / DIST (On/measuring) - button  
Horizontal distance - button  
Plus (+) - button  
CN  
ROK  
PL  
H
For measurements from an edge, fold out the  
positioning bracket until it locks in place at a 90  
degree angle.  
For measurements from a corner, open the posi-  
tioning bracket until it locks in place, then push  
the positioning bracket lightly to the right to fold  
it out fully.  
Minus (-) - button  
Area / volume - button  
Storage - button  
Reference - button  
Functions - button  
Timer - button  
RUS  
CZ  
10 Second function button  
11 Menu/equal - button  
12 Clear/off - button  
A built-in sensor automatically detects the orienta-  
tion of the positioning bracket and adjusts the zero  
point of the instrument accordingly.  
13 Bluetooth button  
Leica DISTO™ D330i 776751 en  
7
Start-up  
 
13 Battery status  
14 Area/volume  
15 Tilt  
D
EN  
F
Display  
19  
13  
14  
6
16 Horizontal distance measurement using tilt  
17 Triangle area  
18 Timer  
7,8,9  
15,16  
33 27 17 18  
12  
I
1
2
4
3
5
20  
29  
21  
30  
19 Menu  
28  
E
20 Circumference  
21 Wall area  
22 Ceiling area  
23 Intermediate line 1  
24 Intermediate line 2  
25 Intermediate line 3  
26 Summary line  
27 Information  
28 Spirit level  
29 Tilt angle  
30 Distance measured  
31 Indirect height  
32 Detail display  
33 Bluetooth Icon  
10,11  
P
23  
24  
25  
NL  
DK  
S
22  
31  
N
26  
FIN  
J
32  
1
2
3
4
5
6
7
8
9
Laser active  
Reference (front)  
CN  
ROK  
PL  
H
Reference (rear)  
Reference (corner stop)  
Measuring with the tripod  
Stake out function  
Single Pythagoras measurement  
Double Pythagoras measurement  
Double (partial height) measurement  
RUS  
CZ  
10 Save constant value, call up constant value  
11 Historical memory, call up values  
12 Spirit level (numeric)  
Leica DISTO™ D330i 776751 en  
 
8
Start-up  
D
EN  
F
Menu functions  
Settings  
The menu allows settings to be changed and perma-  
nently stored. All menu settings will remain active  
when switching off the device or changing the  
batteries. See page 11 for resetting the factory  
defaults  
1
I
7
2
EXIT  
E
P
0.0°  
NL  
DK  
S
Navigation in the menu  
6
3
The menu allows settings to be made at the user  
level. The instrument can be specifically configured to  
your personal requirements.  
4
5
N
General description  
FIN  
J
button (pressed long) - You are in the  
the units set and the first menu item "Unit" are  
displayed.  
,
or  
button (pressed short) brings up the next menu  
item.  
A long press on the  
the new settings made in the submenu items .  
Pressing the button for longer in the menu  
button to make changes in menu items.  
CN  
ROK  
PL  
H
button (pressed short) pages through each  
menu item.  
button in the menu confirms  
allows you to quit the settings function without  
saving.  
RUS  
CZ  
Leica DISTO™ D330i 776751 en  
9
Menu functions  
 
D
EN  
F
Setting the unit for distance  
measurements  
Measuring with the tripod (  
)
The reference must be appropriately adjusted in  
order to be able to take correct measurements with  
The following units can be set:  
a tripod. To do this select  
You can switch the reference on the tripod on or off.  
The setting can be seen on the display  
ON in this menu item.  
Distance  
0.000 m  
0.0000 m  
0.00 m  
Area  
Volume  
0.000 m³  
I
0.000 m²  
0.000 m²  
0.000 m²  
0.00 ft²  
0.00 ft²  
0.00 ft²  
0.00 ft²  
0.00 ft²  
0.00 ft²  
0.00 ft²  
0.00 ft²  
1.  
2.  
.
E
0.000 m³  
0.000 m³  
0.00 ft³  
0.00 ft³  
0.00 ft³  
0.00 ft³  
0.00 ft³  
0.00 ft³  
0.00 ft³  
0.00 ft³  
3.  
4.  
5.  
P
0.00 ft  
Beep (  
)
NL  
DK  
S
0'00'' 1/32  
0'00'' 1/16  
0'00'' 1/8  
0.0 in  
You can switch the beep on or off.  
6.  
7.  
8.  
Level in status field (  
The level (in °) in status field can be switched on or  
off.  
)
N
9.  
10.  
11.  
0 1/32 in  
0 1/16 in  
0 1/8 in  
FIN  
J
Reset - returning the instrument to  
the factory settings (  
)
CN  
ROK  
PL  
H
The instrument has a RESET function. When you  
select the menu function RESET and confirm, the  
instrument defaults to the factory settings.  
Setting the unit for tilt  
measurements  
The following units can be set for tilt measurements:  
A reset returns the following values to their factory  
settings:  
Units for tilt  
+/- 0.0°  
0.00%  
1.  
2.  
RUS  
CZ  
Reference (rear)  
Display illumination (ON)  
Beep (ON)  
Unit (m(mm))  
Leica DISTO™ D330i 776751 en  
 
10  
Menu functions  
Stack and memory are erased  
D
EN  
F
Reference setting  
All customised settings and stored values are  
The default reference setting is from the rear of the  
instrument.  
)
also lost.  
Press this button to take the next measurement  
I
from the front edge  
ever the reference setting is changed.  
. A special beep sounds when-  
Operation  
E
After a measurement the reference returns automat-  
ically to the default setting (rear reference).  
Switching on and off  
P
Switches on the instrument and laser. The  
display shows the battery symbol until the  
next button is pressed.  
NL  
DK  
S
Pressing this button for longer switches  
the instrument off.  
The instrument switches off automatically  
after six minutes of inactivity.  
N
FIN  
J
CLEAR button  
The last action is cancelled. While making  
area or volume measurements, each single measure-  
ment can be deleted and remeasured in series.  
CN  
ROK  
PL  
H
Press this button for longer and the front refer-  
ence is set as default until unit is powered off.  
Press this button, the rear reference is set again.  
RUS  
CZ  
Leica DISTO™ D330i 776751 en  
 
11  
Operation  
D
EN  
F
Minimum/maximum measurement  
Measuring  
This function allows the user to measure the  
minimum or maximum distance from a fixed  
measuring point. It can also be used as to determine  
spacings.  
Single distance measurement  
Press to activate the laser. Press again to trigger  
the distance measurement.  
I
The result is displayed immediately.  
E
min.  
max.  
P
Tilt measurement  
NL  
DK  
S
The tilt sensor measures angles between 45°.  
)
During the measurement of angle, the instru-  
)
ment should be held without transverse tilt, as far as  
possible, ( 10°).  
N
It is commonly used to measure room diagonals  
(maximum values) or horizontal distances (minimum  
values).  
Horizontal measurement  
FIN  
J
Press button to activate horizontal measure-  
ment in the instrument. The following symbol  
appears in the display  
. If the button is active,  
Press and hold down this button until you hear  
a beep. Then slowly sweep the laser back and forth  
and up and down over the desired target point - (e.g.  
into the corner of a room).  
CN  
ROK  
PL  
H
the horizontal distance is displayed in the summary  
line for each distance measurement (up to max. +/-  
45° and up to max. a transverse tilt of +/-10°).  
Press the  
information on the measurement, for example the tilt  
angle , the distance measured and the indi-  
rect height  
Press button again to switch off horizontal  
measurement.  
button for longer to display additional  
Press to stop continuous measurement. The  
values for maximum and minimum distances are  
shown in the display as well as the last measured  
value in the summary line.  
RUS  
CZ  
.
Leica DISTO™ D330i 776751 en  
 
12  
Measuring  
D
EN  
F
Laser continuous  
Functions  
Press and hold down the key when switching  
Addition / subtraction  
Distance measuring.  
on the device until the character  
nently in the display and a beep sounds. Every further  
appears perma-  
I
press of the  
ment.  
key releases a distance measure-  
The next measurement is added to the previous  
one.  
E
Press and hold the key to switch the device  
and Laser continuous operation off.  
If the laser is in continuous operation mode,  
The next measurement is subtracted from the  
previous one.  
P
NL  
DK  
S
This process can be repeated as required.  
)
the device switches off automatically after 15  
minutes.  
Press this button and the result is then always  
shown in the summary line.  
The last step is cancelled.  
N
FIN  
J
Area  
Press once. The  
symbol appears in the  
display.  
CN  
ROK  
PL  
H
Press this button to take the first length  
measurement (e.g. length).  
Press it again to take the second length  
measurement (e.g. width).  
The result is displayed in the summary line.  
RUS  
CZ  
Press the  
circumference  
button for longer to calculate the  
.
Leica DISTO™ D330i 776751 en  
13  
Functions  
 
D
EN  
F
Volume  
Tilt measurement  
Press this button once to activate the tilt  
Press this button twice. The  
appears in the display.  
symbol  
sensor. The  
symbol appears in the display. The  
tilt is continuously shown as ° or % depending on the  
setting.  
Press this button to take the first length  
measurement (e.g. length).  
I
Press to measure the inclination and the  
distance.  
Press this button to take the second length  
measurement (e.g. width).  
E
P
Press this button to take the third length measure-  
ment (e.g. height).  
NL  
DK  
S
The volume then appears in the summary line.  
Press the  
room information such as ceiling/floor area  
surface area of the walls , circumference  
The or button can be used to add or  
subtract multiple area and volume calcuations  
button for longer to display additional  
,
N
.
FIN  
J
)
followed by the  
button to total the values.  
CN  
ROK  
PL  
H
RUS  
CZ  
Leica DISTO™ D330i 776751 en  
 
14  
Functions  
D
EN  
F
Triangular area  
Stake out function  
The area of a triangle can be calculated by the  
measurement of three sides.  
Two different distances (a and b) can be entered into  
the instrument and can then be used to mark off  
defined measured lengths, e.g. in the construction of  
wooden frames.  
I
E
P
1
2
NL  
DK  
S
16 in  
24 in  
3
16 in  
16 in  
16 in  
16 in  
Press the key two times - the triangle symbol  
appears in the display.  
N
Entering stake out distances:  
Press this button three times and the stake out  
FIN  
J
Press the key and measure the first side of the  
triangle.  
a
function symbol appears in the display  
.
b
b
Press the key and measure the second side of  
the triangle.  
The value (a) and the corresponding intermediate line  
flash.  
CN  
ROK  
PL  
H
By using  
and  
, you can adjust the values  
Press the key and measure the third side of the  
triangle.  
(first a and then b) to suit the desired stake out  
distances. Holding the buttons down increases the  
rate of change of the values.  
The resulting area  
is shown in the summary row.  
Press and hold the key to display additional infor-  
mation about the measurement, such as the angle  
RUS  
CZ  
Once the desired value (a) has been reached it can be  
confirmed with the  
button.  
included by the first two measurements  
perimeter of the triangle  
and the  
The value (b) and the intermediate line flashes (the  
.
Leica DISTO™ D330i 776751 en  
 
15  
Functions  
defined value (a) is automatically adopted). Value (b)  
can be entered using and  
The defined value (b) is confirmed with the  
button.  
D
EN  
F
Indirect measurement  
The instrument can calculate distances using  
Pythagoras’ theorem.  
.
Make sure you adhere to the prescribed  
sequence of measurement:  
Pressing the  
button starts the laser measure-  
)
I
ment. The display shows required stake out distance  
in the summary line between the stake out point  
(first a and then b) and the instrument (rear refer-  
ence).  
All target points must be in a horizontal or vertical  
plane.  
E
P
The best results are achieved when the instru-  
ment is rotated about a fixed point (e.g. with the  
positioning bracket fully folded out and the  
instrument placed on a wall).  
NL  
DK  
S
If the DISTO™ is then moved slowly along the stake  
out line the displayed distance decreases. The instru-  
ment starts to beep at a distance of 4 in from the  
The minimum/maximum function can be used -  
see explanation in "Measuring -> Minimum/  
maximum measurement". The minimum value  
must be used for measurements at right angles to  
the target; the maximum distance for all other  
measurements.  
next stake out point.  
a
b
b
N
The arrows in the display  
indicate in which direc-  
tion the DISTO™ needs to be moved in order to  
achieve the defined distance (either a or b). As soon  
as the stake out point is reached the beep changes.  
FIN  
J
Make sure that the first measurement and the  
distance to be measured are at right angles. Use the  
Minimum/maximum function, as explained in  
)
CN  
ROK  
PL  
H
The function can be stopped at any time by pressing  
the  
button.  
"Measuring -> Minimum/maximum measurement".  
RUS  
CZ  
Leica DISTO™ D330i 776751 en  
 
16  
Functions  
Press to stop continuous measurement (2). The  
result is displayed in the summary line, the partial  
results in the secondary line.  
Indirect measurement - determining a dis-  
tance using 2 auxilliary measurements  
D
EN  
F
Indirect Measurement - determining a dis-  
tance using 3 measurements  
I
E
P
NL  
DK  
S
1
2
3
N
e.g. for measuring building heights or widths. It is helpful  
to use a tripod when measuring heights that require the  
measurement of two or three measurements.  
FIN  
J
CN  
ROK  
PL  
H
Press this button four times, the display shows  
Press this button five times; the display shows  
the following symbol  
. The laser is switched on.  
the following symbol  
. The laser is switched on.  
Aim at the upper point (1) and trigger the  
measurement. After the first measurement the value  
is adopted. Keep the instrument as horizontal as  
possible.  
Aim at the upper point (1) and trigger the  
measurement. After the first measurement the value  
is adopted. Keep the instrument as horizontal as  
possible  
RUS  
CZ  
Press and hold down this button to trigger  
continuous measurement, sweep the laser back and  
forth and up and down over the ideal target point.  
Press and hold down this button to trigger  
continuous measurement, sweep the laser up and  
Leica DISTO™ D330i 776751 en  
17  
Functions  
 
down over the ideal target point.  
After the first measurement is recorded and shown  
onscreen, the display flashes (2).  
D
EN  
F
Press to stop continuous measurement (2). The  
value is adopted. Aim at the lower point and  
Triggers the measurement. After the second  
measurement is recorded and shown onscreen, the  
display flashes (3).  
press this button to trigger the measurement  
(3). The result is displayed in the summary line, the  
partial results in the secondary lines.  
I
Press and hold down this button to trigger  
continuous measurement. Sweep the laser up and  
down over the ideal target point.  
E
Indirect measurement - determining a chain  
value using 3 measurements  
P
Press this button to end continuous measure-  
ment. The result is displayed in the summary line, the  
partial results in the secondary lines.  
NL  
DK  
S
Storage of constants/historical  
storage  
N
FIN  
J
1
2
Storage of a constant  
3
You can store and recall a frequently used value e.g.  
height of a room. Measure the desired distance,  
CN  
ROK  
PL  
H
press and hold the  
to confirm storage.  
button until the device beeps  
e.g. determining the height between point 1 and  
point 2 using three target points.  
Recalling the constant  
Press this button once to recall the constant  
and make it available for further calculations by  
Press this button six times; the display shows  
RUS  
CZ  
the following symbol  
. The laser is switched on.  
pressing button  
.
Aim at the upper point (1).  
Press this button and trigger the measurement.  
Leica DISTO™ D330i 776751 en  
 
18  
Functions  
Adjusting the constant  
D
EN  
F
Working with BLUETOOTH®  
Press the  
button for longer to change the constant  
- the constant flashes, you can now change the  
constant to the required value using the  
Switching on BLUETOOTH® /  
sending measurements  
or  
button. Press the  
button to save the constant.  
I
A quick press on the  
- key starts DISTO™ BLUE-  
Historical storage  
TOOTH®. The data connection must then be estab-  
lished out from a Pocket PC / PC by the application  
software. A BLUETOOTH® - icon will appear in the  
display until this has been successfully completed.  
BLUETOOTH® automatically switches off if the  
connection to the Pocket PC / PC is not established  
within 240 sec from when the BLUETOOTH® was  
switched on.  
E
Press this button twice and the previous 20  
results (measurements or calculated results) are  
shown in reverse order.  
P
NL  
DK  
S
The  
and  
Press this button to use a result from the  
summary line for further calculations.  
Pressing the and buttons at the same  
buttons can be used for navigation.  
N
Whilst the first connection between the  
Pocket PC/PC and the DISTO™ is being established, a  
prompt for the Pin-code of the DISTO™ may be  
displayed. In this case, enter the code 0000 into your  
Pocket PC/PC.  
time erases all the values in historical storage.  
)
FIN  
J
Timer (self-triggering)  
Press this button to set a 5-second time delay.  
or  
Press and hold down this button until the  
desired time delay is reached (max. 60 seconds).  
Once the key is released the remaining seconds until  
measurement (e.g. 59, 58, 57...) are displayed in a  
countdown. The last 5 seconds are counted down  
with a beep. After the last beep the measurement is  
taken and the value is displayed.  
CN  
ROK  
PL  
H
Switching off BLUETOOTH®  
BLUETOOTH® switches off as soon as the DISTO™ is  
switched off.  
RUS  
CZ  
The timer can be used for all measurements.  
)
Leica DISTO™ D330i 776751 en  
19  
Working with BLUETOOTH®  
 
The free software supplied is designed to  
D
EN  
F
)
The direction keys  
provide the user with basic functionality. Leica  
Geosystems provides no warranty for this free soft-  
ware and offers no support for it. Leica Geosystems  
accepts no liability whatsoever arising from the use  
of the free software and is not obliged to provide  
corrections nor to develop updates or upgrades.  
You can find numerous commercial vendors of soft-  
ware for a wide range of applications on our  
homepage.  
Eight direction keys (identified by a small arrow near  
the key) on the operator's keypad are used to  
manoeuvre the cursor. The direction keys become  
active when you switch to the second level (by  
I
pressing the  
key). The distance measuring key is  
E
active in both levels. The functionality of the direction  
keys depends on the software used.  
P
NL  
DK  
S
Transmitting the measurement  
If your software supports the direction keys use them  
to select the appropriate position for the cursor.  
Appendix  
Message codes  
All message codes are displayed with either  
"Error". The following errors can be corrected:  
Press the  
button briefly to transfer the value  
N
from the summary row to the pocket PC / PC.  
or  
FIN  
J
Press the  
botton long to transfer all values from  
the display.  
Cause  
Remedy  
For further details please consult your manual for the  
software used.  
156  
160  
CN  
ROK  
PL  
H
Transverse tilt  
Hold the instrument  
without any transverse  
tilt  
greater than 10°  
Main tilt direction,  
angle too high  
(> 45°)  
Measure angle up to  
During data transmission  
max. 45°  
If the data is not confirmed as being successfully  
received by the Pocket PC/ PC then no new measure-  
ment can be processed. The Info code "240" appears  
in the display if no data transmission has taken place  
204  
240  
245  
Calculation error  
Repeat procedure  
Data transfer error Repeat procedure  
2nd button pressed Establish Bluetooth  
RUS  
CZ  
although no Blue-  
tooth connection  
exists.  
connection  
after 2 seconds. Press the  
- key and repeat  
the measurement and then transmit it.  
Leica DISTO™ D330i 776751 en  
 
20  
Appendix  
Power Range  
D
EN  
F
Cause  
Temperature too  
Remedy  
Cool down instrument  
Technology™:  
0.05 m to 100 m  
2 in. to 325 ft  
252  
253  
255  
Range (use target plate  
high  
from about 80m/260ft)  
Temperature too  
low  
Warm up instrument  
Smallest unit displayed  
Distance measurement  
Minimum/maximum  
measurement, Continuous  
measurement  
0.1 mm/ 1  
/32nd  
9
Receiver signal too Use target plate  
I
weak, measurement  
time too long,  
9
E
distance > 100 m  
256  
257  
Received signal too Target too reflective  
P
Area/volume calculation of  
9
9
9
strong  
(use target plate)  
room data  
NL  
DK  
S
Wrong measure-  
Darkentarget(measure  
Addition / subtraction  
ment, background  
in different lighting  
Indirect measurement  
brightness too high conditions)  
using Pythagoras  
260  
Laser beam inter-  
Repeat measurement  
rupted  
Tilt measurements:  
Tilt sensor:  
Error  
Cause  
Error Hardware error  
Remedy  
N
Accuracy  
Switch on/off the  
device several times. If  
the symbol still  
(2 σ, standard deviation)  
FIN  
J
- to laser beam  
- to the housing  
0.3°  
0.3°  
9
appears, then your  
instrument is defective.  
Please call your dealer  
for assistance.  
Horizontal measurement  
CN  
ROK  
PL  
H
Indirect measurement  
using tilt sensor (direct  
horizontal distance)  
9
Angle measurement using  
9
tilt sensor( 45°)  
Technical data  
General:  
Distance  
Laser class  
II  
measurements:  
Measuring accuracy*  
up to 10 m  
typically: 1/16 in*  
RUS  
CZ  
Laser type  
635 nm, < 1 mW  
(
1.0mm)  
Ø laser point  
6 / 30 / 60 mm  
(2 σ, standard deviation)  
(at distances)  
(10 / 50 / 100 m)  
Autom. laser switch-off  
after 3 min  
Leica DISTO™ D330i 776751 en  
 
21  
Appendix  
Autom. instrument  
switch-off  
Display illumination  
Multifunctional endpiece  
Timer (self-triggering)  
Save constant value  
D
EN  
F
after 6 min  
Measuring conditions  
9
9
9
9
Measuring range  
The range is limited to 325 feet.  
At night or dusk and if the target is in shadow the  
measuring range without target plate is increased.  
Use a target plate to increase the measurement  
range during daylight or if the target has poor reflec-  
tion properties.  
I
Historical storage  
E
9
9
(20 values)  
P
BLUETOOTH® 2.0  
Range of BLUETOOTH®  
NL  
DK  
S
10 m  
9
Cl. 2  
Target surfaces  
Tripod thread  
Battery life,  
up to  
Measuring errors can occur when measuring toward  
colourless liquids (e.g. water) or dust free glass,  
Styrofoam or similar semi-permeable surfaces.  
Type AAA, 2 x 1.5V  
5 000 measurements  
Protection against  
IP 54, dust-proof,  
N
splashes and dust  
splash-proof  
Aiming at high gloss surfaces may deflect the laser  
beam and lead to measurement errors.  
FIN  
J
Dimensions  
127 x 49 x 27.3 mm  
5 x 1.93 x 1.06 in  
150 g / 5.25oz  
Weight (with batteries)  
Temperature range:  
Against non-reflective and dark surfaces the  
measuring time may increase.  
CN  
ROK  
PL  
H
Storage  
-13°F up to +158°F  
14°F up to +122°F  
Operation  
* maximum deviation occurs under unfavourable conditions such  
as bright sunlight or when measuring to poorly reflecting or very  
rough surfaces. Measuring accuracy between 10 m and 30 m may  
deteriorate to approx. 0.025 mm/m, for distances above 30 m  
to 0.1 mm/m.  
RUS  
CZ  
Leica DISTO™ D330i 776751 en  
 
22  
Appendix  
D
EN  
F
Care  
Do not immerse the instrument in water. Wipe off dirt  
with a damp, soft cloth. Do not use aggressive  
cleaning agents or solutions. Handle the instrument  
as you would a telescope or camera.  
I
E
Warranty  
P
The Leica DISTO™ D330i comes with a three* year  
warranty from Leica Geosystems AG.  
NL  
DK  
S
More detailed information can be found at:  
N
All illustrations, descriptions and technical specifica-  
tions may be subject to change without prior notice.  
FIN  
J
* To receive the three year warranty, the product must be regis-  
tered on our website www.disto.com within eight weeks of the  
purchase date. If the product is not registered, a two year  
warranty applies.  
CN  
ROK  
PL  
H
RUS  
CZ  
Leica DISTO™ D330i 776751 en  
23  
Appendix  
 
D
EN  
F
I
E
P
NL  
DK  
S
N
FIN  
J
CN  
ROK  
PL  
H
RUS  
CZ  
Leica DISTO™ D330i 776751 en  
 
24  
Appendix  
Leica Geosystems AG, Heerbrugg, Switzerland has been certified as being equipped with a  
quality system which meets the International Standards of Quality Management and Quality  
Systems (ISO standard 9001) and Environmental Management Systems (ISO standard 14001).  
Total Quality Management - Our commitment to total customer satisfaction. Ask your local  
Leica Geosystems agent for more information about our TQM program.  
Copyright Leica Geosystems AG, Heerbrugg,  
Switzerland 2010  
Translation of original text (776751)  
Pat. No.: WO 9427164, WO 9818019, WO 0244754, WO 0216964,  
US 5949531, EP 1195617, US 7030969, WO 03104748  
Leica Geosystems AG  
CH-9435 Heerbrugg  
(Switzerland)  
 

Lasko Fan 2264QM User Manual
Lennox Hearth Indoor Fireplace MPE 36R User Manual
LG Electronics DVD Player GSA 5120D User Manual
LG Electronics Universal Remote 8575 User Manual
Liebert Power Supply Series 610 User Manual
Lightolier Indoor Furnishings 1104F18ESR User Manual
Mackie Speaker HRS120 User Manual
Marley Engineered Products Electric Heater 1800 User Manual
Marshall Amplification Stereo Amplifier Hand Crafted Amplifiers User Manual
Metra Electronics eBook Reader 95 8152 User Manual