April 2000 • J-36
TECHNICAL DATA / CHEMICALS FOR MINILABS
Choosing the Right Chemicals for
Your Minilab
specifically for minilabs. It provides recommended cycles
for processing the following films with KODAK
FLEXICOLOR Chemicals in Processes C-41RA, C-41B,
and C-41*:
This publication describes KODAK Chemicals designed
CHOOSING A FILM PROCESS
To determine which chemicals to use for your film process,
locate the process cycle that best matches the sequence of
processing steps and process times of your minilab.
The following section describes the three basic process
cycles for films, and includes a listing of the appropriate
KODAK FLEXICOLOR Chemicals for each cycle. You can
use any of these cycles with or without a wash step. If you
select a washless cycle, carefully follow the
KODAK ROYAL GOLD Films
KODAK GOLD Films
KODAK MAX Films
KODAK Black & White + 400 Film
KODAK ADVANTIX 100, 200, and 400 Films
KODAK ADVANTIX Black & White + 400 Film
KODAK PROFESSIONAL SUPRA Films
KODAK PROFESSIONAL PORTRA Films
recommendations in the footnotes.
Note: This publication does not discuss KODAK
FLEXICOLOR SM and EKTACOLOR SM Chemicals,
which are designed for use only in specific minilabs. For
detailed information on these chemicals, see KODAK
Publication No. Z-101, Using KODAK SM Chemicals in SM
Minilabs.
It also includes the recommended cycles for processing
KODAK EKTACOLOR Papers with KODAK
EKTACOLOR PRIME SP, EKTACOLOR PRIME, and
EKTACOLOR RA Chemicals for Process RA-4.
For decades, Kodak has been designing and
manufacturing films, papers, and chemicals that reduce the
impact of photoprocessing on the environment. KODAK
EKTACOLOR PRIME SP Developer Replenisher is a new
developer for EKTACOLOR Papers that offers even more
beneficial features. Formulated in a single part, it is
convenient and easy to use. Intended for minilabs with
average to high utilization, it will give consistent print
quality with less effluent discharged and less packaging
waste than KODAK EKTACOLOR PRIME Developer
Replenisher. (See CHOOSING A PAPER PROCESS for
more information on the availability and features of this new
product.)
Use the cycles in this publication as guides. You may
have to modify a cycle slightly to suit the design of your
processor. The replenishment rates for each cycle are
intended for a typical mix of Kodak color negative films.
For more detailed information, see KODAK Publication
No. Z-100, Using KODAK Chemicals in Minilabs, or Z-131,
Using KODAK FLEXICOLOR Chemicals.
Although your choice of chemicals may be limited by
your minilab’s design and its level of utilization, choosing
the chemicals recommended in this publication ensures that
you are using chemicals that provide optimum results with
the smallest possible environmental impact. We continue to
develop new products that will further reduce chemical use
and discharge.
* Do not process films of older design that require a stabilizing agent for
image stability in minilab processes using KODAK FLEXICOLOR Final
Rinse and Replenisher. These films are KODAK VERICOLOR III Film,
VERICOLOR Slide Film / SO-279/5072, and VERICOLOR Print
Film 4111. Process these films only in a processor that uses
FLEXICOLOR Stabilizer III and Replenisher.
©Eastman Kodak Company, 2000
Starting-Point Replenishment Rates—
Process C-41B
Starting-Point Replenishment Rates—
Process C-41
Starting-Point
Replenishment Rate
Starting-Point
Replenishment Rate
Solution
Solution/Step
mL/135-24
Roll
(mL/m)
mL/25-Exp
ADVANTIX Film
(mL/m)*
mL/25-Exp
mL/135-24 Roll
(mL/m)
ADVANTIXFilm
(mL/m)*
FLEXICOLOR Developer
Replenisher LORR
FLEXICOLORDeveloper
Replenisher LORR
19 (17)
5 (4.5)
35 (32)
40 (36)
11.1 (10.2)
3.4 (3.1)
24 (22)
19 (17)
11.1 (10.2)
FLEXICOLOR Bleach III
NR Replenisher
FLEXICOLOR Bleach III
NR Replenisher
5 (4.5)
3.4 (3.1)
850 (734)†
24 (22)
FLEXICOLOR Fixer and
Replenisher
Wash
1250 (1080)†
35 (32)
FLEXICOLOR Fixer and
Replenisher
FLEXICOLOR Final Rinse
and Replenisher
27 (25)
Wash
1250 (1080)†
850 (734)†
* These rates are averages based on an estimated film-speed mix in
25-exposure rolls of KODAK ADVANTIX Films.
FLEXICOLOR
Final Rinse and
Replenisher
35 (32)‡
27 (25)‡
Process C-41
* These rates are averages based on an estimated film-speed mix in
25-exposure rolls of KODAK ADVANTIX Films.
† For a two-stage countercurrent-flow wash. Double this rate for a
single-stage wash.
‡ If your minilab uses a final rinse instead of washes, use a
replenishment rate of 40 mL/135-24 roll (36 mL/m) or
27 mL/25-exposure roll (25 mL/m) of ADVANTIX Film.
This process cycle is sometimes used in older minilabs. It most
commonly includes water washes. To use the washless version
of this cycle, follow the recommendations in the second
footnote under the table.
Process C-41 Cycle
Monitoring Your Film Process
Time*
min:sec
Temperature
°C (°F)
Use KODAK Control Strips, Process C-41, to monitor your
film process. Follow the procedures described in KODAK
Publication No. Z-100, Using KODAK Chemicals in
Minilabs, or Z-131, Using KODAK FLEXICOLOR
Chemicals.
Solution/Step
FLEXICOLOR
Developer Replenisher
LORR
37.8 ± 0.15
(100.0 ± 0.25)
3:15
FLEXICOLOR Bleach
III NR Replenisher
38 ± 3
(100 ± 5)
4:20 to 6:30
1:00 to 3:15
4:20 to 6:30
2:10 to 3:15
24 to 41
(75 to 105)
Wash†
FLEXICOLOR Fixer
and Replenisher‡
38 ± 3
(100 ± 5)
24 to 41
(75 to 105)
Wash†
FLEXICOLOR
Final Rinse and
Replenisher
24 to 41
(75 to 105)
1:05
40 to 68
(104 to 155)
Dry
As needed
* Immersion time plus crossover time to the next tank. Bleach, fixer, and
final rinse times are minimums; longer times are acceptable.
† Use a two-stage countercurrent-flow wash. For a single-stage wash,
double the replenishment rate.
If your minilab uses a final rinse step instead of a final wash, eliminate
both washes. Use three countercurrent-flow final rinse tanks with a
minimum final rinse time of 2:20 (0:47 in each tank). Use a final rinse
temperature of 38 ± 3°C (100 ± 5°F) and a replenishment rate of
40 mL/135-24 roll (36 mL/m).
‡ Use two countercurrent-flow fixer tanks with equal times in both tanks
(2:10 to 3:15).
Choosing the Right Chemicals for Your Minilab • J-36
3
Developer Options for Process RA-4 Based on
Processor Utilization
CHOOSING A PAPER PROCESS
KODAK EKTACOLOR PRIME SP Developer Replenisher
is a new paper developer that is replacing the following
products:
4 x 6 - inch
(102 x 152 cm)
prints per day:
500
750
1000
1250
1875
2500
125
250
375
5
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
10
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
KODAK EKTACOLOR PRIME Developer
Replenisher
15
Tank
olume
(Litres)
20
25
30
KODAK EKTACOLOR PRIME Developer
Replenisher LORR
40
50
KODAK EKTACOLOR PRIME Developer
Regenerator
EKTACOLOR RA Developer Replenisher RT
EKTACOLOR PRIME SP Developer Replenisher (New)
Because the new developer will not be available in all
regions at the same time, this publication includes
recommendations for EKTACOLOR PRIME SP Developer
Replenisher and the products it will replace.
SP
F002_0994AC
Most minilabs have been able to use EKTACOLOR
PRIME Chemicals and realize cost savings and reductions in
processing-solution waste. EKTACOLOR PRIME SP
Developer Replenisher offers even greater advantages:
easier mixing with a single-part concentrate, further
reductions in replenishment rates and effluents for users of
EKTACOLOR PRIME Developer Replenisher, and less
packaging waste. (For information about converting, see
Converting to KODAK EKTACOLOR PRIME SP Developer
Replenisher.)
If your lab operates at low utilization or if your equipment
has a roller-transport design, KODAK EKTACOLOR RA
Developer Replenisher RT will continue to provide the best
process performance.
Before choosing a Process RA-4 cycle, it is important to
understand processor utilization and the level of operation of
your minilab paper processor.
If EKTACOLOR PRIME SP Developer Replenisher is
not yet available in your country, use the table and products
below:
4 x 6 - inch
(102 x 152 cm)
prints per day:
500
750
1000
1250
1875
2500
125
250
375
5
* * * * * *
* * * * *
* * * *
* * * *
* * *
10
15
Tank
Volume
(Litres)
20
25
30
* *
40
50
* *
*
EKTACOLOR RA Developer Replenisher RT
EKTACOLOR PRIME Developer Replenisher
EKTACOLOR PRIME Developer Replenisher
or
EKTACOLOR PRIME Developer Replenisher LORR
Processor Utilization
*
Utilization is a way of expressing how much of your
processor’s capacity is used. If your processor utilization is
low, oxidation and evaporation will affect the activity of
your processing solutions.
The simplest way to determine your processor utilization
is to measure “tank turnovers” of your developer tank
solution. One tank turnover is the point at which the volume
of replenisher added to the tank equals the volume of the
processor tank.
F002_0938AC
Note: If you use EKTACOLOR PRIME Developer
Replenisher, use EKTACOLOR PRIME Bleach-Fix
Replenisher. If your processor operates at low utilization,
use EKTACOLOR RA Developer Replenisher RT and
EKTACOLOR RA Bleach-Fix and Replenisher.
EKTACOLOR PRIME SP Developer Replenisher is
designed for minilabs that have average to high utilization,
i.e., a developer tank turnover occurs at least once every four
weeks. If your paper processor operates at low utilization—
i.e., it takes longer than four weeks for a developer tank
turnover to occur—you should use KODAK EKTACOLOR
RA Developer Replenisher RT and EKTACOLOR RA
Bleach-Fix and Replenisher. These chemicals contain more
preservative and are replenished at a higher rate to minimize
the effects of low utilization.
To determine the option that is suitable for your minilab,
use the information in the following charts. To use these
charts, you need to know the number of prints you process
each week. Utilization is based on a 10-percent makeover
rate and a six-day work week.
4
Choosing the Right Chemicals for Your Minilab • J-36
Process RA-4 Cycle—Average Utilization
This cycle is appropriate for processors with average
utilization—i.e., a developer tank turnover occurs at least
once every four weeks.
Process RA-4 Cycle—High Utilization
This cycle is appropriate for processors with high
utilization—i.e., a developer tank turnover occurs at least
once every two weeks.
Starting-Point
Temperature Replenishment
Starting-Point
Solution/
Step
Time*
min:sec
Solution/
Step
Time* Temperature
Replenishment
Rate
°C (°F)
Rate
mL/m (mL/ft )
min:sec
°C (°F)
2
2
2
2
mL/m (mL/ft )
EKTACOLOR
PRIME SP
Developer
Replenisher†
or
EKTACOLOR
PRIME SP
Developer
Replenisher†
or
108 (10)
37.8 ± 0.3
(100.0 ± 0.5)
0:45
37.0 ± 0.3
(100.0 ± 0.5)
0:45
108 (10)
EKTACOLOR
PRIME
EKTACOLOR
PRIME
161 (15)
Developer
Replenisher
Developer
Replenisher
LORR
EKTACOLOR
PRIME
Bleach-Fix
Replenisher
30 to 36
(86 to 97)
EKTACOLOR
RA 100
Bleach-Fix
and
Replenisher‡
0:45
1:30
108 (10)
248 (23)
30 to 36
(86 to 97)
0:45
1:30
54 (5)
EKTACOLOR
PRIME
Stabilizer and
Replenisher‡
30 to 37
(86 to 99)
EKTACOLOR
PRIME
30 to 37
(86 to 99)
248 (23)
Stabilizer and
Replenisher§
As
needed
Not over
96 (205)
Dry
As
needed
Not over
96 (205)
Dry
* Immersion time plus crossover time to the next tank. For best results,
use the recommended times with crossover times of 6 seconds or less.
† This developer may not yet be available in your country. If not, use
EKTACOLOR PRIME Developer Replenisher in a processor with
average utilization.
* Immersion time plus crossover time to the next tank. For best results,
use the recommended times with crossover times of 6 seconds or less.
† This developer may not yet be available in your country. If not, use
EKTACOLOR PRIME Developer Replenisher LORR in a processor
with high utilization.
‡ Use four countercurrent-flow stabilizer tanks with equal times in all
tanks (0:23 in each tank). With three countercurrent-flow tanks, use a
replenishment rate of 495 mL/m2 (46 mL/ft2); with two
‡ This product will be renamed KODAK EKTACOLOR PRIME
Bleach-Fix Replenisher LORR.
2
2
countercurrent-flow tanks, use 970 mL/m (90 mL/ft ).
If your minilab uses a countercurrent-flow wash instead of a
stabilizer, use a wash-water temperature of 30 to 40°C (86 to 104°F).
For wash times of 1:30 or longer, the wash-flow rate should be
between 2160 and 10,800 mL/m2 (200 and 1000 mL/ft2). The actual
rate depends on the number of tanks and the wash time (see KODAK
Publication No. Z-100, Using KODAK Chemicals in Minilabs, or Z-130,
Using KODAK EKTACOLOR RA Chemicals).
§ Use four countercurrent-flow stabilizer tanks with equal times in all
tanks (0:23 in each tank). With three countercurrent-flow tanks, use a
replenishment rate of 495 mL/m2 (46 mL/ft2); with two
countercurrent-flow tanks, use 970 mL/m2 (90 mL/ft2).
If your minilab uses a countercurrent-flow wash instead of a
stabilizer, use a wash-water temperature of 30 to 40°C (86 to 104°F).
For wash times of 1:30 or longer, the wash-flow rate should be between
2160 and 10,800 mL/m2 (200 and 1000 mL/ft2). The actual rate
depends on the number of tanks and the wash time (see KODAK
Publication No. Z-100, Using KODAK Chemicals in Minilabs, or Z-130,
Using KODAK EKTACOLOR RA Chemicals).
Choosing the Right Chemicals for Your Minilab • J-36
5
Process RA-4 Cycle—Low Utilization
This cycle is appropriate for processors with low
utilization—i.e., a developer tank turnover requires longer
than four weeks.
Converting to KODAK EKTACOLOR PRIME SP
Developer Replenisher
Before converting to EKTACOLOR PRIME SP Developer
Replenisher, use all of your current stock of EKTACOLOR
PRIME Developer Replenisher (and EKTACOLOR PRIME
Developer Regenerator) or EKTACOLOR PRIME
Developer Replenisher LORR. You do not need to dump
your current working tank solution.
Starting-Point
Solution/
Step
Time* Temperature
Replenishment
Rate
min:sec
°C (°F)
2
2
mL/m (mL/ft )
When you begin to use EKTACOLOR PRIME SP
Developer Replenisher to replenish your existing developer
tank solution, adjust your replenishment rate to the
appropriate setting in the following table. If you currently
use EKTACOLOR PRIME Developer Replenisher LORR,
you do not need to adjust your replenishment rate.
EKTACOLOR
RA Developer
Replenisher
RT
35 ± 0.3
0:45
215 (20)
(95 ± 0.5)
EKTACOLOR
RA
Bleach-Fix
and
30 to 36
(86 to 97)
0:45
1:30
215 (20)
248 (23)
Replenishment Rate
Replenisher
Current
Replenishment Rate
with PRIME SP
Developer
Replenisher
EKTACOLOR
PRIME
Stabilizer and
Replenisher†
Current
Developer
Solution
30 to 37
(86 to 99)
mL/ mL/ mL/ mL/ mL/ mL/ mL/ mL/
m2 ft2 m* ft† m2 ft2 m* ft†
As
needed
Not over
96 (205)
Dry
PRIME
Developer
Replenisher
and
Developer
Regenerator
* Immersion time plus crossover time to the next tank. For best results,
use the recommended times with crossover times of 6 seconds or less.
† Use four countercurrent-flow stabilizer tanks with equal times in all
tanks (0:23 in each tank). With three countercurrent-flow tanks, use a
161 15 20.5 6.3
108 10 13.7 4.17
108 10 13.7 4.17
2
2
replenishment rate of 495 mL/m (46 mL/ft ); with two
2
2
countercurrent-flow tanks, use 970 mL/m (90 mL/ft ).
PRIME
If your minilab uses a countercurrent-flow wash instead of a
stabilizer, use a wash-water temperature of 30 to 40°C (86 to 104°F).
For wash times of 1:30 or longer, the wash-flow rate should be between
2160 and 10,800 mL/m2 (200 and 1000 mL/ft2). The actual rate
depends on the number of tanks and the wash time (see KODAK
Publication No. Z-100, Using KODAK Chemicals in Minilabs, or Z-130,
Using KODAK EKTACOLOR RA Chemicals).
Developer
Replenisher
LORR
* Normally, mL per linear metre of paper 127 mm (5 in.) wide.
† Normally, mL per linear foot of paper 127 mm (5 in.) wide.
Note: If your process is in control with EKTACOLOR
PRIME Developer Replenisher, you can also calculate the
replenishment rate for EKTCOLOR PRIME SP Developer
Replenisher by multiplying your current rate by 0.67. Then,
reset the rate (or pump setting) to the new rate. If you need
help adjusting the replenishment rate, contact your minilab
manufacturer.
Monitoring Your Paper Process
Use KODAK Control Strips, Process RA-4, to monitor your
paper process. Follow the procedures described in KODAK
Publication No. Z-100, Using KODAK Chemicals
in Minilabs, or Z-130, Using KODAK EKTACOLOR RA
Chemicals.
6
Choosing the Right Chemicals for Your Minilab • J-36
KODAK FLEXICOLOR Final Rinse and Replenisher
This final rinse is designed with state-of-the-art surfactants
to reduce deposits and drying marks on processed color
negative films. It also reduces the potential for biological
growth in the mixed solution. This means less maintenance
and less frequent dumping of working tanks. Because the
new final rinse contains no stabilizing agent, labs will not
need to provide formaldehyde training or do the associated
record keeping required by OSHA guidelines. You can use
the final rinse in minilabs that operate with a wash or a
washless cycle.
KODAK CHEMICALS FOR YOUR FILM
PROCESSOR
KODAK FLEXICOLOR Chemicals are supplied as
all-liquid concentrates for easy mixing. They are available in
sizes that are economical and convenient for minilabs. For
more information on processing with these chemicals, visit
KODAK FLEXICOLOR Developer Replenisher LORR
This developer has low replenishment rates that help reduce
developer effluent discharge by as much as 50 percent.
Lower replenishment rates mean less chemical mixing and
lower cost per roll of film processed. Use only
FLEXICOLOR Developer Starter LORR to prepare a fresh
tank solution with FLEXICOLOR Developer Replenisher
LORR.
Note: Do not process films of older design that require a
stabilizing agent for image stability. These films are
KODAK VERICOLOR III Film, VERICOLOR Slide
Film / SO-279/5072, and VERICOLOR Print Film 4111.
Process these films only in a processor that uses
FLEXICOLOR Stabilizer III and Replenisher. Films of more
recent design, such as KODAK GOLD, MAX, ROYAL
GOLD, PROFESSIONAL PORTRA, PROFESSIONAL
EKTAPRESS, and PROFESSIONAL SUPRA Films require
no stabilization for image stability. They will have optimum
image-stability performance when processed with
Available in sizes to make 5 and 10 litres and 25 U.S. gallons
(two 12.5-gallon sizes).
KODAK FLEXICOLOR Developer Starter LORR
Use this starter to prepare a fresh tank solution from
FLEXICOLOR Developer Replenisher LORR.
Available in a size to prepare 8.3 U.S. gallons of developer
tank solution from developer replenisher.
FLEXICOLOR Final Rinse and Replenisher.
Available in sizes to make 5 and 10 litres and 12.5 and
75 U.S. gallons.
KODAK FLEXICOLOR Bleach III NR Replenisher
For use in minilabs using Process C-41B or C-41, this bleach
offers reduced cost per roll of film and reduced
replenishment rates and volume of effluent discharged. It
requires no mixing; it is packaged ready to use. Use
FLEXICOLOR Bleach Starter to prepare a fresh tank
solution.
KODAK CHEMICALS FOR YOUR PAPER
PROCESSOR
These chemicals are supplied as all-liquid concentrates for
easy mixing and handling. They are available in sizes that are
convenient and economical for minilabs.
Available in a 5-litre size.
KODAK EKTACOLOR PRIME SP Developer
Replenisher
KODAK FLEXICOLOR RA Bleach Replenisher NR
This bleach is designed for use in minilabs that use Process
C-41RA. It requires no mixing; it is packaged ready to use.
This bleach is also odorless. Use FLEXICOLOR Bleach
Starter to prepare a fresh tank solution.
This new developer replenisher is designed for minilabs with
average to high utilization. Supplied as a single-part
concentrate, it offers easy and convenient mixing.
Replenishment rates are significantly lower than those of
EKTACOLOR PRIME Developer Replenisher.
Available in sizes to prepare 10 litres and 20 gallons (two
10-gallon mixes) of replenisher solution.
Available in a 5-litre size.
KODAK FLEXICOLOR Bleach Starter
Use this starter to prepare a bleach tank solution with
FLEXICOLOR Bleach III NR Replenisher or
FLEXICOLOR RA Bleach Replenisher NR. This product is
odorless, non-corrosive, and non-foaming for easy use.
Available as a 1-gallon concentrate to make 20 U.S. gallons
of Bleach III NR tank solution or 8.3 U.S. gallons of RA
Bleach NR tank solution.
Note: EKTACOLOR PRIME SP Developer Replenisher
will replace EKTACOLOR PRIME Developer Replenisher,
EKTACOLOR PRIME Developer Replenisher LORR, and
EKTACOLOR PRIME Developer Regenerator. The
discontinuance of these three products will occur at different
times in different regions.
KODAK EKTACOLOR PRIME Developer Replenisher
If new EKTACOLOR PRIME SP Developer Replenisher is
not yet available in your region, use this developer if your
minilab processor has a developer tank turnover every
four weeks (or more frequently).
KODAK FLEXICOLOR Fixer and Replenisher
Use this fixer for Process C-41 or C-41B.
Available in sizes to make 5 litres and 5 and 25 U.S. gallons.
KODAK FLEXICOLOR RA Fixer and Replenisher
This fixer is designed for use in minilabs that use Process
C-41RA.
Available in sizes to prepare 10 litres and 25 gallons (two
12.5-gallon mixes) of solution.
Available in sizes to make 5 and 10 litres.
Choosing the Right Chemicals for Your Minilab • J-36
7
Choosing the Right Chemicals for Your Minilab
KODAK EKTACOLOR PRIME Developer Replenisher
LORR
KODAK EKTACOLOR RA 100 Bleach-Fix and
Replenisher
If new EKTACOLOR PRIME SP Developer Replenisher is
You can use this bleach-fix if your processor has a tank
turnover at least every four weeks. The replenishment rate is
75 percent lower than that of EKTACOLOR RA Bleach-Fix.
This product will be renamed KODAK EKTACOLOR
PRIME Bleach-Fix Replenisher LORR.
not yet available in your region, use this developer if your
minilab consistently operates at high utilization, i.e., a
developer tank turnover occurs at least once every two
weeks.
Available in sizes to prepare 10 litres and 25 gallons (two
12.5-gallon mixes) of replenisher solution.
Available in sizes to prepare 5 litres and 5 gallons of solution.
KODAK EKTACOLOR RA Bleach-Fix and Replenisher
If it takes more than four weeks to turn over the bleach-fix tank
solution, use this replenisher. Dilute this concentrate to
prepare a tank or replenisher solution.
Available in sizes to prepare 5 and 10 litres and 25 gallons of
solution.
KODAK EKTACOLOR PRIME Developer Regenerator
If new EKTACOLOR PRIME SP Developer Replenisher is
not yet available in your region, your can use this regenerator
to regenerate and reuse EKTACOLOR PRIME
Developer overflow.
Available in sizes to prepare 10 litres and 25 gallons of
replenisher solution from developer overflow.
KODAK EKTACOLOR PRIME Stabilizer and
Replenisher
KODAK EKTACOLOR RA Developer Replenisher RT
If your minilab takes longer than four weeks for a tank
turnover, use this developer.
Use this stabilizer in place of a final wash in washless
minilabs.
Available in sizes to prepare 5 and 10 litres and
12.5 gallons of solution.
Available in sizes to prepare 5 and 10 litres and 25 gallons.
KODAK EKTACOLOR RA Developer Starter
To make developer tank solutions, mix this starter with
KODAK EKTACOLOR PRIME SP Developer Replenisher,
EKTACOLOR PRIME Developer Replenisher,
EKTACOLOR PRIME Developer Replenisher LORR, or
EKTACOLOR RA Developer Replenisher RT according to
the directions on the starter label.
MORE INFORMATION
For the latest version of technical support publications for
KODAK Products, visit Kodak on-line at:
The Material Safety Data Sheets for these products are
available on the Kodak web site:
KODAK EKTACOLOR PRIME Bleach-Fix Replenisher
Use this bleach-fix if you use EKTACOLOR PRIME SP or
PRIME Developer Replenisher. The replenishment rate with
this bleach-fix is 50 percent lower than the rate for
EKTACOLOR RA Bleach-Fix and Replenisher.
Available in sizes to prepare 10 litres and 12.5 gallons of
solution.
www.kodak.com/go/MSDS
Many technical support publications for
KODAK Products can be sent to your fax machine
from the Kodak Information Center. Call:
U.S. 1-800-242-2424, Ext. 33 / Canada 1-800-295-5531
—Available 24 hours a day, 7 days a week—
If you have questions about KODAK Products, call Kodak.
In the U.S.A.:
1-800-242-2424, Monday–Friday
9 a.m.–7 p.m. (Eastern time)
In Canada:
1-800-465-6325, Monday–Friday
8 a.m.–5 p.m. (Eastern time)
Consumer Imaging
EASTMAN KODAK COMPANY • ROCHESTER, NY 14650
Choosing the Right Chemicals for
Your Minilab
Kodak, Advantix, Ektacolor, Ektacolor SM, Flexicolor,
Flexicolor SM, Gold, Max, Prime, and Royal are trademarks.
Major Revision 4-00
Printed in U.S.A.
KODAK Publication No. J-36
CAT 849 8800
|