KitchenAid Double Oven KEBC167M User Manual

®
36" Built-in Single Oven  
PRODUCT MODEL SERIES  
OVERALL DIMENSIONS  
KEBC167M  
34-3/8" max.  
recessed  
width  
Electrical: A four-wire or three-wire, single  
phase, 240-volt, 60 Hz, AC-only electrical supply is  
required on a separate, 30-ampere circuit, fused  
on both sides of the line.Use minimum 8 gauge  
copper wire only. A time-delay fuse or circuit  
breaker is recommended. A U.L.-listed conduit  
connector must be provided at the junction box.  
29" max.  
overall  
height  
27-1/2"  
recessed  
height  
35-3/4"  
overall width  
23" max.  
recessed  
depth  
CABINET OPENING DIMENSIONS  
36" min.  
cabinet width  
36" min.  
cabinet width  
1" top of cutout  
to bottom of  
upper cabinet  
door  
1-1/2" min.  
top of cutout  
to underside  
of countertop  
Single  
undercounter oven  
(without cooktop  
installed above)  
27-3/4"  
min.  
cutout  
height  
27-3/4"  
34-1/2"  
cutout  
width  
min.  
cutout  
height  
34-1/2"  
cutout width  
5-1/4" bottom of  
cutout to floor  
23-1/4" min.  
cutout depth  
1-1/2" min.  
bottom of  
cutout to  
top of  
32"  
23" recessed  
oven depth  
bottom of  
cutout to  
floor  
cabinet  
door  
Cabinet side  
view  
Electrical supply junction box should be located 3 inches maximum  
below the support surface when oven is installed in a wall cabinet. Drill  
a 1-inch minimum diameter hole in the right rear or left rear corner of  
the support surface to pass the appliance cable through to the junction  
box. For undercounter installation, it is recommended that the junction  
box be located in the adjacent right or left cabinet. If installing the  
junction box on rear wall behind oven, junction box must be recessed  
and located in the upper or lower right or left corner of cabinet.  
oven  
front  
recessed  
oven  
cabinet  
Because Whirlpool Corporation policy includes a continuous commitment to improve  
our products, we reserve the right to change materials and specifications without notice.  
Dimensions are for planning purposes only. For complete details, see Installation  
Instructions packed with product. Specifications subject to change without notice.  
Ref. 8301807  
02-13-04  
 
CUTOUT DIMENSIONS FOR OVENS INSTALLED UNDER COOKTOP  
CANADA ONLY  
IMPORTANT: Observe all governing codes and ordinances. Cooktop must be approved for use over an oven. See Cooktop Installation  
Instructions for cutout dimensions. Center the cooktop cutout over oven cutout. The junction box for the oven can be installed on either  
side of the cutout area. The shaded area not used for the oven junction box is recommended for a junction box for the cooktop.  
Approved Built-In Ovens and Electric Cooktops  
NOTE: The installation of gas cooktops and oven combinations is  
not approved for use in Canada.  
B
C
A
A. 24" (61 cm) cabinet depth  
B. 4" (10.2 cm) to top of countertop  
C. 25" (63.5 cm) countertop depth  
D. 27¾" (70.5 cm) minimum cutout height  
E. Junction box 9" (22.9 cm) to center of cutout  
F. Junction box 9" (22.9 cm) to center of cutout  
G. Allow ⁵⁄₈" (1.6 cm) for oven trim to overlap on each side.  
H. 36" (91.4 cm) from cabinet base to countertop  
I. 4⁵⁄₈" (11.7 cm) from floor  
D
H
G
E
F
J. See Cutout Dimensions chart.  
I
CUTOUT DIMENSIONS  
J
Oven Size  
Oven Cutout Dimension  
25¹⁄₂" (64.8 cm)  
For the approved model number combination refer to the  
undercounter label located on top of the oven chassis and on  
the bottom of the cooktop burner box.  
27" (68.6 cm)  
30" (76.2 cm)  
28½" (72.4 cm)  
FOUR INSTALLÉ SOUS LA TABLE DE CUISSON - DIMENSIONS  
POUR L'OUVERTURE À DÉCOUPER - CANADA SEULEMENT  
IMPORTANT : Observer toutes les dispositions des codes et règlements en vigueur. La table de cuisson doit être homologuée pour  
l'utilisation au-dessus d'un four. Pour les dimensions de l'ouverture à découper, voir les Instructions d'installation de la table de  
cuisson. Centrer l'ouverture à découper pour la table de cuisson par rapport à l'ouverture découpée pour le four. On peut installer le  
boîtier de connexion pour le four d'un côté ou de l'autre de l'ouverture découpée. On recommande d'utiliser pour le boîtier de  
connexion de la table de cuisson la zone grisée qui n'est pas été utilisée pour le boîtier de connexion du four.  
Combinaisons table de cuisson/four encastré(produits homologués)  
REMARQUE : L'installation de combinaisons table de cuisson à  
gaz/four n'est pas approuvée pour utilisation au Canada.  
B
C
A
A. Profondeur de placard 24" (61 cm)  
B. 4" (10,2 cm) jusquau sommet du plan de travail  
C. Profondeur du plan de travail 25" (63,5 cm)  
D. Hauteur minimale de l'ouverture à découper 27¾" (70,5 cm)  
E. Boîtier de connexion 9" (22,9 cm) jusqu'au centre de  
l'ouverture découpée  
F. Boîtier de connexion 9" (22,9 cm) jusqu'au centre de  
l'ouverture découpée  
D
H
G
E
F
G. Prévoir ⁵⁄₈" (1,6 cm) pour le chevauchement de la garniture du  
four, de chaque côté.  
H. 36" (91,4 cm) entre la base du placard et le plan de travail  
I. 4⁵⁄₈" (11,7 cm) depuis le plancher  
I
J. Voir le tableau Dimensions de l'ouverture à découper.  
OUVERTURE À DÉCOUPER - DIMENSIONS  
J
Taille du four  
27" (68,6 cm)  
30" (76,2 cm)  
Ouverture à découper pour le four  
25¹⁄₂" (64,8 cm)  
Pour connaître les combinaisons approuvées par numéro de  
modèle, consulter l'étiquette située sur la partie supérieure  
du châssis du four et au fond de la boîte de brûleur de la  
table de cuisson.  
28½" (72,4 cm)  
8303946  
© 2005.  
7/05  
All rights reserved.  
Tous droits réservés.  
Printed in U.S.A.  
Imprimé aux É.-U.  
 

John Deere Kitchen Utensil FP1204 User Manual
JVC Car Video System KW AVX846 User Manual
JVC CRT Television AV28R250EK User Manual
JVC Digital Camera GC QX3HD User Manual
JVC Projection Television HD 52FA97 User Manual
JVC Stereo System VS DT2000R User Manual
Kambrook Toaster KT60 User Manual
Kenwood Stereo Amplifier KAF 1010 User Manual
Keys Fitness Home Gym CM850U User Manual
KitchenAid Tool Storage KSRS27ILBL02 User Manual